Debian Codegraph @

examples/all_atom/force_field_explicit_parameters/nanotube+water/run.in.npt

raw
1 # PREREQUISITES:
2 #
3 # You must use moltemplate.sh to create 3 files:
4 # system.data system.in.init system.in.settings
5 # (You do not need to run LAMMPS to equilibrate the system before
6 # using this file.)
7 #
8 # Requirements:
9 # To run this system at constant pressure, it might help to compile LAMMPS with
10 # the optional RIGID package, and use "fix rigid" on the carbon. (Optional.)
11 # The use of fix rigid is controversial. This method is demonstrated below.
12 # THIS EXAMPLE HAS NOT BEEN RIGOROUSLY TESTED. This simulation may fail.
13 # (However the "run.in.nvt" example in this directory should work.)
14 # ------------------------------- Initialization Section --------------------
15
16 include "system.in.init" # specify the style of force field used
17
18 # ------------------------------- Atom Definition Section -------------------
19
20 read_data "system.data" # load atom coordinates and topology
21
22 # ------------------------------- Settings Section --------------------------
23
24 include "system.in.settings" # load the force field parameters
25
26 # Use "neigh_modify" to turn off calculation of interactions between immobilized
27 # atoms. (Note: group "cGraphene" was defined in the file "system.in.settings")
28
29 neigh_modify exclude group Cgraphene Cgraphene
30
31 # ------------------------------- Run Section -------------------------------
32
33
34 # Only the Cgraphene atoms are immobile.
35 group mobile subtract all Cgraphene
36
37 # (Note: The "Cgraphene" group was defined in "system.in.settings".)
38
39 # Unfortunately you can not use the LAMMPS "minimize" command on this system
40 # because there is no way to immobilize the carbon graphene & nanotube atoms
41 # during minimization. Instead, we can use langevin dynamics with a fast
42 # damping parameter and a small timestep.
43
44 print "---- beginning minimization (using fix langevin, not minimize) ----"
45
46 timestep 0.1
47
48 # Give each atom a random initial velocity consistent with a system at 1.0K.
49 velocity mobile create 1.0 12345
50
51 fix fxlan mobile langevin 1.0 1.0 100.0 48279
52 fix fxnve mobile nve # <-- needed by fix langevin (see lammps documentation)
53
54 thermo 100
55 run 2500
56
57 unfix fxlan
58 unfix fxnve
59
60 # -- simulation protocol --
61
62 print "--------- beginning simulation (using fix nvt) ---------"
63
64 dump 1 all custom 1000 traj_npt.lammpstrj id mol type x y z ix iy iz
65
66 unfix fShakeSPCE # Disable SHAKE during minimization and pressure equilibr
67
68 thermo_style custom step temp pe etotal press vol epair ebond eangle edihed
69 thermo 200 # time interval for printing out "thermo" data
70
71
72
73
74
75 # ------------------------- NPT ---------------------------
76
77
78 # ------ QUESTIONABLE (see below): ------
79
80 fix Ffreezestuff Cgraphene rigid single force * off off off torque * off off off
81
82 # Comment:
83 # The use of "fix rigid" to immobilize an object is somewhat controversial.
84 # Feel free to omit it.
85 # (Neither Trung or Steve Plimpton use fix rigid for immobilizing
86 # molecules, but I noticed that at NPT, it does a better job of maintaining
87 # the correct volume. However "fix rigid" has changed since then (2011),
88 # so this may no longer be true. Please use this example with caution.)
89
90
91 # Thermostat+Barostat
92 # Set temp=300K, pressure=200bar, and equilibrate volume only in the z direction
93
94 fix fxMoveStuff mobile npt temp 300 300 100 z 200 200 1000.0 dilate mobile drag 2.0
95
96 # ----------------------------------------
97
98 # The next two lines recalculate the temperature using
99 # only the mobile degrees of freedom (ie. water atom velocities):
100
101 compute tempMobile mobile temp
102 compute pressMobile all pressure tempMobile
103
104 thermo_style custom step c_tempMobile c_pressMobile temp press vol
105
106 fix_modify fxMoveStuff temp tempMobile
107
108 reset_timestep 0
109
110 timestep 0.25
111
112 run 20000
113
114 timestep 0.5
115
116 run 50000
117
118
119 # Hopefully the barostat is no longer oscillating. Then we can try using fix
120 # npt again and omit the "drag 2.0" argument. (A non-zero drag parameter will
121 # result in unrealistic fluctuations of volume under NPT conditions.)
122 # First, undo the previous "fix npt"
123
124 unfix fxMoveStuff
125
126 # Then re-apply "fix npt"
127 # Set temp=300K, pressure=0bar, and equilibrate volume only in the z direction
128 fix fxMoveStuff mobile npt temp 300 300 100 z 0 0 1000.0 dilate mobile
129 fix_modify fxMoveStuff temp tempMobile
130
131 timestep 0.5 # (Perhaps we can increase this timestep to 1.0? I'm not sure.)
132
133 run 5000000
134
135 write_data system_after_npt.data
136
137 # (The "write_restart" and "read_restart" commands were buggy in 2012,
138 # but they should work also.)
139
140
141
142
143
144
145
146 # ----- Comment: Avoid using fix rigid/npt on large single rigid objects -----
147 #
148 # Use of the following is not recommended:
149 #
150 # fix Ffreezestuff Cgraphene rigid/npt single temp 300 300 100 z 200 200 1000.0 force * off off off torque * off off off dilate mobile
151 # (temp=300K, pressure=200bar, and equilibrate volume only in the z direction)
152 #
153 # In my experience, the system becomes unstable when applying "fix rigid/npt"
154 # to the immobile atoms, while also applying "fix npt" on the solvent atoms.
155 # (It is probably a bad idea to use two barostats simultaneously.)
156 # ----------------------------------------------------------------------------