Debian Codegraph @

examples/all_atom/force_field_OPLSAA/waterTIP5P+ethanol/run.in.npt

raw
1 # PREREQUISITES:
2 #
3 # 1) You must use moltemplate.sh to create 4 files:
4 # system.data system.in.init system.in.settings system.in.charges
5 # (See README_setup.sh for details.)
6 #
7 # 2) You must then run the minimization simulation beforehand using:
8 # lmp_mpi -i run.in.min (assuming "lmp_mpi" is your lammps binary's name)
9
10 # ------------------------------- Initialization Section --------------------
11
12 include system.in.init
13
14 # ------------------------------- Atom Definition Section -------------------
15
16 #read_data system.data <-commenting out. use minimized conformation instead
17
18 read_data system_after_min.data
19
20 # ------------------------------- Settings Section --------------------------
21
22 include system.in.settings #(define force fields and constraints)
23
24 # ------------------------------- Run Section -------------------------------
25
26 # -- files containing trajectory data and other information --
27
28 thermo_style custom step temp pe ke etotal press vol epair ebond eangle edihed
29 thermo_modify norm yes
30 thermo 100
31 dump 1 all custom 500 traj_npt.lammpstrj id mol type x y z ix iy iz
32
33
34 # -- simulation protocol --
35
36 velocity all create 298.0 12345 # choose the starting velocities randomly
37
38
39 timestep 1.0
40
41
42 group gRigid union gH2O gH2O
43 group gFlexible subtract all gRigid
44
45 # Give each atom a random initial velocity consistent with a system at 298K.
46 velocity all create 298.0 12345
47
48 fix fxRigid gH2O rigid/nph/small molecule iso 1 1 1000
49 fix fxFlexible gFlexible nve
50 fix fxLanvegin all langevin 298 298 10000.0 48279
51
52 run 100000
53
54 write_data system_after_npt.data
55
56
57
58
59
60 # NOTE:
61 # The following alternate protocol seems to agree with the protocol used above:
62 # (but this observation was based on an extremely short simulation)
63 #
64 # fix fxRigid gH2O rigid/npt/small molecule temp 298 298 100 iso 1 1 1000
65 # fix fxFlexible gFlexible nvt temp 298 298 100.0
66 #
67 # <temp>~=297, <ke>~=0.45, <press>~=0, <volume>~=21900 (based on 10000 steps)
68 #
69 #
70 #
71 #
72 # AVOID THESE PROTOCOLS FOR SIMULATIONS CONTAINING RIGID & FLEXIBLE MOLECULES:
73 # 1)
74 # fix fxRigid gH2O rigid/nvt/small molecule temp 298 298 100
75 # fix fxFlexible gFlexible npt temp 298 298 100.0 iso 1 1 1000
76 # (System behaves as if being compressed)
77 # <temp>~=295, <ke>~=0.46, <press>~=10000, <volume>~=16500 (based on 10000steps)# 2)
78 # fix fxRigid gH2O rigid/nve/small molecule
79 # fix fxFlexible gFlexible nph iso 1 1 1000
80 # fix fxLanvegin all langevin 298 298 5000.0 48279
81 # (System behaves as if compressed. Temperature is elevated)
82 # <temp>~=315, <ke>~=0.48, <press>~=11000, <volume>~=17000 (based on 10000steps)
83 # 3)
84 # fix fxRigid gH2O rigid/npt/small molecule temp 298 298 100 iso 1 1 1000
85 # fix fxFlexible gFlexible nve
86 # (System behaves as it would at a lower temperature)
87 # <temp>~=241, <ke>~=0.36, <press>~=0, <volume>~=20800 (based on 10000steps)
88 # 4)
89 # fix fxRigid gH2O rigid/nve/small molecule langevin 298 298 5000.0 48279
90 # fix fxFlexible gFlexible nph iso 1 1 1000
91 # fix fxLanvegin gFlexible langevin 298 298 5000.0 48279
92 # (System behaves as if compressed. Temperature is elevated)
93 # <temp>~=315, <ke>~=0.48, <press>~=10000, <volume>~=17000 (based on 10000steps)
94 # 5)
95 # fix fxRigid gH2O rigid/nph/small molecule iso 1 1 1000
96 # fix fxFlexible gFlexible nvt temp 298 298 100.0
97 # (system behaves as it would at a higher temperature)
98 # <temp>~=355, <ke>~=55, <press>~=0, <volume>~=30000 (based on 10000 steps)
99 #
100 #
101 #
102 #
103 # EXCERPT from "https://lammps.sandia.gov/doc/fix_rigid.html"
104 # "If you with to perform NPT or NPH dynamics (barostatting), you cannot
105 # use both fix npt and the NPT or NPH rigid styles. This is because there
106 # can be one fix which monitors the global pressure and changes the
107 # simulation box dimensions. So you have 3 choices:
108 #
109 # Use one of the 4 NPT or NPH styles for the rigid bodies. Use the dilate all
110 # option so that it will dilate the positions of the non-rigid particles as well
111 #
112 # Use fix nvt (or any other thermostat) for the non-rigid particles.
113 # Use fix npt for the group of non-rigid particles. Use the dilate all option
114 # so that it will dilate the center-of-mass positions of the rigid bodies as
115 # well. Use one of the 4 NVE or 2 NVT rigid styles for the rigid bodies.
116 #
117 # Use fix press/berendsen to compute the pressure and change the box dimensions.
118 # Use one of the 4 NVE or 2 NVT rigid styles for the rigid bodies. Use fix nvt
119 # (or any other thermostat) for the non-rigid particles.
120 #
121 # In all case, the rigid bodies and non-rigid particles both contribute to
122 # the global pressure and the box is scaled the same by any of the
123 # barostatting fixes."