Debian Codegraph @

examples/all_atom/force_field_OPLSAA/hexadecane/run.in.npt

raw
1 # PREREQUISITES:
2 #
3 # You must use moltemplate.sh to create 4 files:
4 # system.data system.in.init system.in.settings system.in.charges
5 # (Follow the instructions in README_setup.sh,
6 # or run the file as a script using ./README_setup.sh)
7
8 # ------------------------------- Initialization Section --------------------
9
10 include system.in.init
11
12 # ------------------------------- Atom Definition Section -------------------
13
14 read_data system.data
15
16 # ------------------------------- Settings Section --------------------------
17
18 include system.in.settings
19 include system.in.charges
20
21 # ------------------------------- Run Section -------------------------------
22
23 # Explanation.
24 # Unless you use packmol (or some other geometry generation program),
25 # the initial geometry created by moltemplate using a lattice is
26 # extremely unrealistic for a liquid, and likely to put the system
27 # a kinetic trap (local minimum). So this example uses high temperatures
28 # to completely obliterate any memory of that initial lattice shape.
29 # Then it uses a combination of high pressures and cooling to bring
30 # the system back down to a temperature and density of a liquid at 1atm, 300K.
31
32 # I am using a 4-step equilibraion process (expand, minimize,
33 # reorient, compress). The system (as defined in the "system.data" file)
34 # is already expanded. That means there are 3 steps left:
35
36 dump dumpeq1 all custom 50 traj_eq1_min.lammpstrj id mol type x y z ix iy iz
37 thermo_style custom step temp ke pe etotal epair ebond eangle edihed press vol
38 thermo 50
39
40 # -- Equilibration: part 1: initial minimization --
41
42 # Note: In general, it's always a good idea to minimize the system at first.
43
44 minimize 1.0e-5 1.0e-7 100000 400000
45 undump dumpeq1
46
47 write_data system_after_eq1_min.data
48
49 # -- Equilibration part 2: reorienting the molecules (NVT) --
50
51 timestep 1.0
52 dump dumpeq2 all custom 200 traj_eq2_reorient.lammpstrj id mol type x y z ix iy iz
53
54 # Run the system at high temperature (at constant volume) to reorient the
55 # the molecules (which would otherwise be pointing in the same direction).
56
57 # To speed it up, I randomize the atomic positions for a few thousand steps
58 # using fix langevin (and fix nve). Then I switch to fix nvt (Nose-Hoover).
59 # (If I start with fix nvt (Nose-Hoover), it seems to get "stuck" for a while.)
60
61 # Give each atom a random initial velocity consistent with a system at 900K.
62 velocity all create 900.0 12345
63
64 # Run a short simulation using a Langevin thermostat.
65
66 fix fxlan all langevin 900.0 900.0 120 48279
67 fix fxnve all nve
68
69 run 4000
70
71 unfix fxlan
72 unfix fxnve
73 # Now continue the simulation at high temperature using fix nvt (Nose-Hoover).
74 fix fxnvt all nvt temp 900.0 900.0 100.0
75
76 run 50000
77 undump dumpeq2
78
79
80 write_data system_after_eq2_reorient.data
81
82 unfix fxnvt
83
84 # -- equilibration part 3: Equilibrating the density (NPT) --
85
86 # Originally, the simulation box (in "system.data" and "system.lt") was
87 # unrealistically large. The spacing between the molecules was large also.
88 # I did this to enable the molecules to move freely and reorient themselves.
89 # After doing that, we should run the simulation under NPT conditions to
90 # allow the simulation box to contract to it's natural size. We do that here:
91 # To help it collapse, we begin the simulation at a relatively high pressure
92 # Later on, we will slowly decrease it to 1 bar.
93
94 # First cool the system. (Do this at high pressure to avoid bubble formation.)
95
96 dump dumpeq3 all custom 200 traj_eq3_npt.lammpstrj id mol type x y z ix iy iz
97 fix fxnpt all npt temp 900.0 260.0 100.0 iso 500.0 500.0 1000.0 drag 2.0
98
99 timestep 1.0
100 run 20000
101
102 # At the very end of the previous simulation, the temperature dropped below
103 # the boiling point. Run the simulation for longer at these conditions to
104 # give it a chance for the vapor -> liquid transition to complete.
105 # We will also slowly decrease the pressure to 1 bar.
106
107 unfix fxnpt
108 fix fxnpt all npt temp 260.0 260.0 100.0 iso 500.0 1.0 1000.0 drag 2.0
109
110 timestep 1.0
111 run 100000
112
113 write_data system_after_eq3_npt.data
114