Debian Codegraph @

docs/IBMPC-charsets.announce

raw
1
2 Summary
3 =======
4 This document is primarily for people who will be using Lynx
5 on a remote UNIX or VMS system via an MS-DOS based terminal program.
6
7
8 General Information
9 ===================
10 Lynx comes with built-in translation tables to map the 8-bit character codes or
11 character entities coming in from an HTML document to their equivalent codes,
12 where possible, for various character sets.
13
14 IMPORTANT: you should choose display character set in Lynx Options Menu
15 according to your font installed locally. Probably it would be cpXXX. Please
16 contact lynx-dev mailing list if you want any new codepage not listed there.
17
18 Note that all points of the connection between the display at your end and Lynx
19 at the remote end must be 8-bit clean. If the high bit is being stripped at
20 any point in between, the only character set you can use (effectively) in Lynx
21 will be "7 bit approximations". More on that later.
22
23
24 MS-DOS character set weirdness
25 ==============================
26 MS-DOS uses a bass-ackwards character set in which half the normal characters
27 have been replaced by pseudo-graphic line and box-drawing characters, and in
28 which almost all of the international characters are mapped to nonstandard
29 numbers. It also contains Greek letters.
30
31 Further confusing matters, there is more than one MS-DOS character set. The
32 character sets are referred to as "codepages," each of which has a unique
33 number. IBM PCs and compatibles come with one hardware-based default codepage
34 and a keyboard to match. In the US market the hardware codepage is 437. PCs
35 destined for other regions of the world often have a different default codepage
36 which contains characters for other languages and keyboards. Under MS-DOS, one
37 can load different codepages into memory and use one of them instead of the
38 hardware default.
39
40 If you are using Lynx through an MS-DOS based terminal program or telnet
41 client, you should use an appropriate DOS codepage in Lynx and you need not any
42 translation within terminal program (this is different from old-style behavior
43 and works better because of superior Lynx translation support).
44
45 Check your display by accessing Martin Ramsch's ISO-8859-1 table
46 (iso8859-1.html in the Lynx distribution's test subdirectory).
47
48 Ramsch's table describes each entity and shows examples of each. It should be
49 immediately obvious that you are either seeing what you are supposed to, or
50 you're not. If you see box and line-drawing characters and mismatched letters
51 and so on, you are likely displaying 7 bit data, not 8. Ensure that all points
52 of your connection are 8-bit clean:
53
54 On any remote UNIX systems you must pass through, do
55 'stty cs8 -istrip' or 'stty pass8'. 'stty -a' should list
56 your settings.
57 On any remote VMS systems, do 'set terminal /eightbit'.
58 Make sure your terminal program or telnet client is not filtering
59 8-bit data. You may found the choice between "VT-100 strict"
60 and "VT-100 relaxed" emulation mode - use relaxed.
61 Note: Procomm for DOS has a confusing "Use 7 bit or 8 bit
62 ANSI" setting -- this has to do with ANSI sequences. If set to
63 8 bit, some 8-bit character sequences, including those passed
64 by Lynx as well as those which are for your terminal type
65 (vt100, etc.) will be processed by Procomm as ANSI screen
66 control codes and will most likely result in a garbled display.
67 Set it to 7 bit.
68 If going through a dialup terminal server, you may have to set the
69 terminal server itself to pass 8 bit data. How to do this
70 varies with the make of the server, and in some cases only a
71 system admin in charge of the box will have the authorization
72 to do that.
73 SLIP or PPP connections should already be 8-bit clean.
74