| 1 |
<?php |
| 2 |
plugin_header(); |
| 3 |
|
| 4 |
$x1 = strpos($PAGE, '_x1') > 0; |
| 5 |
$x2 = strpos($PAGE, '_x2') > 0; |
| 6 |
$x4 = strpos($PAGE, '_x4') > 0; |
| 7 |
?> |
| 8 |
|
| 9 |
<p> |
| 10 |
This plugin implements a simple, but flexible, oscilloscope. |
| 11 |
</p> |
| 12 |
|
| 13 |
<p> |
| 14 |
<? if ($x1) { ?> |
| 15 |
The oscilloscope channel has the following features: |
| 16 |
<? } else { ?> |
| 17 |
Each oscilloscope channel has the following features: |
| 18 |
<? } ?> |
| 19 |
</p> |
| 20 |
<ul> |
| 21 |
<li><b>X</b> input channel.</li> |
| 22 |
<li><b>X</b> output channel.</li> |
| 23 |
<li><b>Y</b> input channel.</li> |
| 24 |
<li><b>Y</b> output channel.</li> |
| 25 |
<li><b>EXT</b> input channel.</li> |
| 26 |
<li><b>Triggered</b> operation.</li> |
| 27 |
<li><b>XY</b> operation.</li> |
| 28 |
<li><b>Goniometer</b> operation.</li> |
| 29 |
</ul> |
| 30 |
<p> |
| 31 |
The <b>X</b> channel is used to drive the horizontal coordinate of the trace plotted on the oscilloscope graph in |
| 32 |
<b>XY</b> and <b>Goniometer</b> operation. In <b>Triggered</b> mode the horizontal coordinate is driven by an |
| 33 |
internal sweep generator. |
| 34 |
</p> |
| 35 |
<p> |
| 36 |
The <b>Y</b> channel is used to drive the vertical coordinate of the trace plotted on the oscilloscope graph. |
| 37 |
</p> |
| 38 |
<p> |
| 39 |
The <b>EXT</b> (external) channel is an alternative channel that can be used to drive the trigger. |
| 40 |
</p> |
| 41 |
<p> |
| 42 |
All channels can be freely oversampled and passed through a DC blocking filter. |
| 43 |
</p> |
| 44 |
<p> |
| 45 |
In a more general fashion with respect most scopes, each channel has a full set of channels and can have a different |
| 46 |
timebase. Multichannel scopes also have general controls that can be used to override multiple channels. |
| 47 |
</p> |
| 48 |
|
| 49 |
<p><b>Controls:</b></p> |
| 50 |
|
| 51 |
<p><b>'OSCILLOSCOPE GRAPH' section:</b></p> |
| 52 |
<p> |
| 53 |
The Oscilloscope Graph and the controls above and below it are documented below. |
| 54 |
</p> |
| 55 |
<ul> |
| 56 |
<li> |
| 57 |
<b>OSCILLOSCOPE GRAPH</b> - This graph will show the various traces the oscilloscope is able to produce. |
| 58 |
The graticule shows bright lines and faint lines. The <b>Divisions</b>, both vertical and horizontal, are shown as bright lines. |
| 59 |
</li> |
| 60 |
<li> |
| 61 |
<b>Freeze Controls</b> - These controls are available on the top left of the oscilloscope graph. Use these |
| 62 |
controls to freeze the entire scope graph (<b>Freeze</b> button) or single channels with the dedicated buttons |
| 63 |
(for multichannel versions). |
| 64 |
</li> |
| 65 |
<li> |
| 66 |
<b>Mute/Solo Controls</b> - These controls are available for multichannel scopes on the top right of the oscilloscope |
| 67 |
graph. They allow to set each individual channel to solo or mute. |
| 68 |
</li> |
| 69 |
<li> |
| 70 |
<b>History</b> - This control, located at the bottom of the oscilloscope graph, allows the user to set the amount of |
| 71 |
previous traces that are allowed to persist on the oscilloscope graph together with the current trace. Older traces |
| 72 |
are plotted with progressive transparency. For stable signals, the resulting effect is akin to that of the persistency |
| 73 |
of analog scopes. |
| 74 |
</li> |
| 75 |
<li> |
| 76 |
<b>XY Sweep</b> - This control, located at the bottom of the oscilloscope graph, is enabled only for <b>XY</b> and |
| 77 |
<b>Goniometer</b> modes. In these modes, it controls the amount of memory the oscilloscope uses to draw the traces. |
| 78 |
</li> |
| 79 |
<li> |
| 80 |
<b>Max Dots</b> - This control, located at the bottom of the oscilloscope graph, allows the user to tune the amount of |
| 81 |
dots that are used to draw the traces on the oscilloscope graph. The higher number of dots can produce smoother traces, but |
| 82 |
at the expenses of UI load. |
| 83 |
</li> |
| 84 |
<li> |
| 85 |
<b>H|V|T Labels</b> - These labels mirror the values of division chosen by the user on the main scopes settings - |
| 86 |
<b>horizontal</b>, <b>vertical</b> and <b>time</b>. They are located at the bottom of the oscilloscope graph for quick |
| 87 |
reference. |
| 88 |
</li> |
| 89 |
</ul> |
| 90 |
|
| 91 |
<p><b>'Controls' section:</b></p> |
| 92 |
<p> |
| 93 |
This section, located at the rigtmost side of the UI, contains the main oscilloscope controls. |
| 94 |
</p> |
| 95 |
<ul> |
| 96 |
<li> |
| 97 |
<b>Channel Selector</b> - For multichannel scopes, this control is located at the top right of the UI and is used |
| 98 |
to select the channel on which the controls below will operate. |
| 99 |
</li> |
| 100 |
<li> |
| 101 |
<b>Freeze/Solo/Mute</b> - These buttons are used to set the selected channel to <b>Freeze</b>, <b>Solo</b> end |
| 102 |
<b>Mute</b> respectively. |
| 103 |
</li> |
| 104 |
<li> |
| 105 |
<b>Oversampler</b> - This control is used to select the oversampler mode. High oversampling produces smoother traces. |
| 106 |
Available modes are below. |
| 107 |
</li> |
| 108 |
<ul> |
| 109 |
<li><b>None</b> - oversampling is not used.</li> |
| 110 |
<li><b>x2</b> - 2x downsampling.</li> |
| 111 |
<li><b>x3</b> - 3x downsampling.</li> |
| 112 |
<li><b>x4</b> - 4x downsampling.</li> |
| 113 |
<li><b>x6</b> - 6x downsampling.</li> |
| 114 |
<li><b>x8</b> - 8x downsampling.</li> |
| 115 |
</ul> |
| 116 |
<li> |
| 117 |
<b>Mode</b> - This control sets the main oscilloscope mode. The following modes are available: |
| 118 |
</li> |
| 119 |
</li> |
| 120 |
<ul> |
| 121 |
<li> |
| 122 |
<b>XY</b> - In this mode the the trace horizontal coordinate is driven by the channel <b>X</b> input, while the vertical |
| 123 |
trace coordinate is driven by the channel <b>Y</b> input. |
| 124 |
</li> |
| 125 |
<li> |
| 126 |
<b>Triggered</b> - In this mode the trace horizontal coordinate is driven by the internal sweep generator, which is in |
| 127 |
turn controlled by the channel trigger, while the trace vertical coordinate is driven by the channel <b>Y</b> input. |
| 128 |
</li> |
| 129 |
<li> |
| 130 |
<b>Goniometer</b> - In this mode the trace horizontal coordinate is driven by half of the sum of the <b>X</b> and <b>Y</b> |
| 131 |
inputs, the vertical trace coordinate is driven by half their difference. |
| 132 |
</li> |
| 133 |
</ul> |
| 134 |
<li> |
| 135 |
<b>Sweep Type</b> - This control is active in <b>Triggered</b> mode and sets the type of sweep signals which drives the trace |
| 136 |
X value. The sweeps are initiated when the trigger fires and, after completion, remain dormant until the next trigger fire is |
| 137 |
allowed. The following types are available. |
| 138 |
</li> |
| 139 |
<ul> |
| 140 |
<li><b>Sawtooth</b> - The sweep is a sawtooth wave.</li> |
| 141 |
<li><b>Triangular</b> - The sweep is a triangular wave.</li> |
| 142 |
<li><b>Sine</b> - The sweep is a sine wave.</li> |
| 143 |
</ul> |
| 144 |
<li> |
| 145 |
<b>Horizontal</b> - These controls allow tuning of the horizontal trace properties. The available controls are listed below. |
| 146 |
</li> |
| 147 |
<ul> |
| 148 |
<li> |
| 149 |
<b>Division</b> - In <b>Triggered</b> mode, this control sets the size, in milliseconds, of the horizontal division value |
| 150 |
in the oscilloscope graph. In <b>XY</b> and <b>Goniometer</b> instead it controls, in units of amplitude, the horizontal |
| 151 |
division value in the oscilloscope graph. |
| 152 |
</li> |
| 153 |
<li> |
| 154 |
<b>Position</b> - This trigger allows to introduce an horizontal shift in the trace. The shift is specified as a percentage |
| 155 |
of the half horizontal span of the oscilloscope graph. |
| 156 |
</li> |
| 157 |
</ul> |
| 158 |
<li> |
| 159 |
<b>Vertical</b> - These controls allow tuning of the vertical trace properties. The available controls are listed below. |
| 160 |
</li> |
| 161 |
<ul> |
| 162 |
<li><b>Division</b> - This control sets, in units of amplitude, the vertical division value in the oscilloscope graph.</li> |
| 163 |
<li> |
| 164 |
<b>Position</b> - This trigger allows to introduce a vertical shift in the trace. The shift is specified as a percentage of |
| 165 |
the half vertical span of the oscilloscope graph. |
| 166 |
</li> |
| 167 |
</ul> |
| 168 |
<li> |
| 169 |
<b>Trigger</b> - These controls tune the channel trigger. They are active only in <b>Triggered</b> mode. |
| 170 |
</li> |
| 171 |
<ul> |
| 172 |
<li> |
| 173 |
<b>Level</b> - This control sets the level of the trigger. The level is specified as a percentage of the half vertical |
| 174 |
span of oscilloscope graph. When the <b>Edge Type</b> is Simple, this level is shown in the oscillator graph as an |
| 175 |
horizontal line. |
| 176 |
</li> |
| 177 |
<li> |
| 178 |
<b>Hysteresis</b> - This control is active only for the <b>Advanced</b> Edge types. This control allows to split the |
| 179 |
trigger level in two levels, separated by the hysteresis value, that need to be crossed in the right order to cause the |
| 180 |
trigger to fire. The hysteresis value is specified as a percentage of the full vertical span of the oscilloscope graph. |
| 181 |
When the <b>Edge Type</b> is Advanced the values of level +/- hysteresis are shown on the oscilloscope graph as horizontal |
| 182 |
lines. |
| 183 |
</li> |
| 184 |
<li> |
| 185 |
<b>Hold Time</b> - This control sets, in seconds, the amount of time that needs to elapse between consecutive trigger firings. |
| 186 |
This time has a lower bound calculated internally from the sweep properties. |
| 187 |
</li> |
| 188 |
<li> |
| 189 |
<b>Input</b> - This control is used to select the input channel for the trigger. Available channels are <b>Y</b> and <b>EXT</b>. |
| 190 |
</li> |
| 191 |
<li> |
| 192 |
<b>Run/Stop</b> - This button is only active for <b>Single</b> and <b>Manual</b> modes and allows to start a trigger and |
| 193 |
sweep cycle. |
| 194 |
</li> |
| 195 |
<li><b>Mode</b> - This control sets the trigger mode. The modes below are available.</li> |
| 196 |
<ul> |
| 197 |
<li> |
| 198 |
<b>Single</b> - In this mode, the scope is allowed to complete a single trigger and sweep cycle after which it freezes. |
| 199 |
To restart the cycle, use the <b>Run/Stop</b> button. |
| 200 |
</li> |
| 201 |
<li> |
| 202 |
<b>Manual</b> - In this mode the scope is allowed, after pressing the <b>Run/Stop</b> button, to complete a single trigger |
| 203 |
and sweep cycle after which it freezes. |
| 204 |
</li> |
| 205 |
</ul> |
| 206 |
<li><b>Edge Type</b> - This controls set the trigger edge type. The following edge types are available</li> |
| 207 |
<ul> |
| 208 |
<li><b>None</b> - In this edge type the trigger is firing with sweep period.</li> |
| 209 |
<li> |
| 210 |
<b>Simple Rising</b> - This edge type causes the trigger to fire when the signal passes through the threshold in the |
| 211 |
ascending direction. The threshold is set by the trigger <b>Level</b> control. |
| 212 |
</li> |
| 213 |
<li> |
| 214 |
<b>Simple Falling</b> - This edge type causes the trigger to fire when the signal passes through the threshold in the |
| 215 |
falling direction. The threshold is set by the trigger <b>Level</b> control. |
| 216 |
</li> |
| 217 |
<li> |
| 218 |
<b>Advanced Rising</b> - This edge type causes the trigger to fire when the signal passes through two thresholds in |
| 219 |
the ascending direction. The thresholds are set by the trigger <b>Level</b> and <b>Hysteresis</b> controls. |
| 220 |
</li> |
| 221 |
<li> |
| 222 |
<b>Advanced Falling</b> - This edge type causes the trigger to fire when the signal passes through two thresholds in |
| 223 |
the falling direction. The thresholds are set by the trigger <b>Level</b> and <b>Hysteresis</b> controls. |
| 224 |
</li> |
| 225 |
</ul> |
| 226 |
<li> |
| 227 |
<b>Coupling X|Y|EXT</b> - For each of the <b>X</b>, <b>Y</b> and <b>EXT</b> channels, these controls allow to set |
| 228 |
the coupling. The following couplings are available. |
| 229 |
</li> |
| 230 |
<ul> |
| 231 |
<li><b>AC</b> - In this coupling type, the signal is passed through a DC block filter.</li> |
| 232 |
<li><b>DC</b> - In this coupling type, the signal is unfiltered.</li> |
| 233 |
</ul> |
| 234 |
</ul> |
| 235 |
</ul> |
| 236 |
|
| 237 |
<p><b>'Global Settings' section:</b></p> |
| 238 |
<p> |
| 239 |
These controls are available only for multichannel scopes, and are located on the right of the oscilloscope graph. |
| 240 |
They are exactly the same of the <b>'Controls' section:</b> and are used to override the single channels settings. |
| 241 |
</p> |
| 242 |
<p> |
| 243 |
In order to override one channel control with the global, select the channel with the <b>Channel Selector</b> and activate the |