| 1 |
# Example configuration for the SuperMicro PDSMi+. |
| 2 |
# Contributed by Romain Dolbeau & Jean Delvare |
| 3 |
|
| 4 |
|
| 5 |
# settings for the supermicro PDSMi+ |
| 6 |
# |
| 7 |
# Notes: |
| 8 |
# 1) You need lm-sensors >= 2.10.2, otherwise you get an error about |
| 9 |
# missing temp6. |
| 10 |
# |
| 11 |
# Originally written by Romain Dolbeau <[email protected]> |
| 12 |
# Uses at your own risk ! |
| 13 |
chip "w83793-i2c-*-2f" |
| 14 |
|
| 15 |
# 0x10, CPU Core |
| 16 |
label in0 "CPU Core" |
| 17 |
# 0x11, unconnected according to support, 1.5V in BIOS ? |
| 18 |
label in1 "+1.5V" |
| 19 |
set in1_min 1.5*0.95 |
| 20 |
set in1_max 1.5*1.05 |
| 21 |
# 0x12, unconnected according to support, VTT=1.2V in BIOS ? |
| 22 |
label in2 "VTT" |
| 23 |
set in2_min 1.2*0.95 |
| 24 |
set in2_max 1.2*1.05 |
| 25 |
# 0x14, -12V |
| 26 |
label in3 "-12V" |
| 27 |
# From Supermicro support information... |
| 28 |
# compute in3 (((@/8)*18500)/256)-16, (((@+16)*256)/18500)*8 |
| 29 |
# ... but this from Jean Delvare works better in pratice |
| 30 |
compute in3 (@ * 5.14) - 14.91, (@ + 14.91) / 5.14 |
| 31 |
set in3_min -12*1.05 |
| 32 |
set in3_max -12*0.95 |
| 33 |
# 0x15, DIMM |
| 34 |
label in4 "DIMM" |
| 35 |
# 0x16, +3.3V |
| 36 |
label in5 "+3.3V" |
| 37 |
set in5_min 3.3*0.95 |
| 38 |
set in5_max 3.3*1.05 |
| 39 |
# 0x17, +12V |
| 40 |
label in6 "+12V" |
| 41 |
compute in6 @*12,@/12 |
| 42 |
set in6_min 12*0.95 |
| 43 |
set in6_max 12*1.05 |
| 44 |
# Ox18, +5V |
| 45 |
label in7 "+5V" |
| 46 |
compute in7 @-0.15,@+0.15 |
| 47 |
set in7_min 5*0.95 |
| 48 |
set in7_max 5*1.05 |
| 49 |
# 0x19, 5VSB |
| 50 |
label in8 "5VSB" |
| 51 |
compute in8 @-0.15,@+0.15 |
| 52 |
set in8_min 5*0.95 |
| 53 |
set in8_max 5*1.05 |
| 54 |
# 0x1a, Battery Voltage |
| 55 |
label in9 "VBAT" |
| 56 |
|
| 57 |
label temp1 "CPU Temp" |
| 58 |
ignore temp2 |
| 59 |
ignore temp3 |
| 60 |
ignore temp4 |
| 61 |
# System Temp used to live at temp5, but was moved to temp6 for some reason |
| 62 |
ignore temp5 |
| 63 |
# label temp5 "System Temp" |
| 64 |
# ignore temp6 |
| 65 |
label temp6 "System Temp" |
| 66 |
|
| 67 |
# 6 connected |
| 68 |
label fan1 "fan1" |
| 69 |
label fan2 "fan2" |
| 70 |
label fan3 "fan3" |
| 71 |
label fan4 "fan4" |
| 72 |
label fan5 "fan5" |
| 73 |
# apparently, fan6 is skipped and fan7 is used instead for CPU fan, |
| 74 |
# at least that's how I understand Supermicro data. |
| 75 |
ignore fan6 |
| 76 |
label fan7 "CPU fan" |
| 77 |
ignore fan8 |
| 78 |
ignore fan9 |
| 79 |
ignore fan10 |
| 80 |
ignore fan12 |
| 81 |
ignore fan12 |
| 82 |
# you should ignore the last 3 or 4, in 1U rackmount system |