Debian Codegraph @

configs/SuperMicro/PDSMi+.conf

raw
1 # Example configuration for the SuperMicro PDSMi+.
2 # Contributed by Romain Dolbeau & Jean Delvare
3
4
5 # settings for the supermicro PDSMi+
6 #
7 # Notes:
8 # 1) You need lm-sensors >= 2.10.2, otherwise you get an error about
9 # missing temp6.
10 #
11 # Originally written by Romain Dolbeau <[email protected]>
12 # Uses at your own risk !
13 chip "w83793-i2c-*-2f"
14
15 # 0x10, CPU Core
16 label in0 "CPU Core"
17 # 0x11, unconnected according to support, 1.5V in BIOS ?
18 label in1 "+1.5V"
19 set in1_min 1.5*0.95
20 set in1_max 1.5*1.05
21 # 0x12, unconnected according to support, VTT=1.2V in BIOS ?
22 label in2 "VTT"
23 set in2_min 1.2*0.95
24 set in2_max 1.2*1.05
25 # 0x14, -12V
26 label in3 "-12V"
27 # From Supermicro support information...
28 # compute in3 (((@/8)*18500)/256)-16, (((@+16)*256)/18500)*8
29 # ... but this from Jean Delvare works better in pratice
30 compute in3 (@ * 5.14) - 14.91, (@ + 14.91) / 5.14
31 set in3_min -12*1.05
32 set in3_max -12*0.95
33 # 0x15, DIMM
34 label in4 "DIMM"
35 # 0x16, +3.3V
36 label in5 "+3.3V"
37 set in5_min 3.3*0.95
38 set in5_max 3.3*1.05
39 # 0x17, +12V
40 label in6 "+12V"
41 compute in6 @*12,@/12
42 set in6_min 12*0.95
43 set in6_max 12*1.05
44 # Ox18, +5V
45 label in7 "+5V"
46 compute in7 @-0.15,@+0.15
47 set in7_min 5*0.95
48 set in7_max 5*1.05
49 # 0x19, 5VSB
50 label in8 "5VSB"
51 compute in8 @-0.15,@+0.15
52 set in8_min 5*0.95
53 set in8_max 5*1.05
54 # 0x1a, Battery Voltage
55 label in9 "VBAT"
56
57 label temp1 "CPU Temp"
58 ignore temp2
59 ignore temp3
60 ignore temp4
61 # System Temp used to live at temp5, but was moved to temp6 for some reason
62 ignore temp5
63 # label temp5 "System Temp"
64 # ignore temp6
65 label temp6 "System Temp"
66
67 # 6 connected
68 label fan1 "fan1"
69 label fan2 "fan2"
70 label fan3 "fan3"
71 label fan4 "fan4"
72 label fan5 "fan5"
73 # apparently, fan6 is skipped and fan7 is used instead for CPU fan,
74 # at least that's how I understand Supermicro data.
75 ignore fan6
76 label fan7 "CPU fan"
77 ignore fan8
78 ignore fan9
79 ignore fan10
80 ignore fan12
81 ignore fan12
82 # you should ignore the last 3 or 4, in 1U rackmount system