| 1 |
# ASRock AB350 Pro4 |
| 2 |
# 2018, contributed by Leigh Brown |
| 3 |
# |
| 4 |
# dmi: board_name: AB350 Pro4 |
| 5 |
# dmi: board_vendor: ASRock |
| 6 |
# dmi: bios_version: P4.60 |
| 7 |
# cpu: AMD Ryzen 5 1600 Six-Core Processor |
| 8 |
# driver: nct6775 |
| 9 |
|
| 10 |
chip "k10temp-pci-00c3" |
| 11 |
label temp1 "CPU Core Temp" |
| 12 |
|
| 13 |
chip "nct6779-isa-0290" |
| 14 |
label in0 "Vcore" |
| 15 |
compute in0 @*2, @/2 |
| 16 |
set in0_min 0.30 |
| 17 |
set in0_max 1.45 |
| 18 |
|
| 19 |
label in1 "+5.0V" |
| 20 |
compute in1 @*4, @/4 |
| 21 |
set in1_min 5.00 * 0.90 |
| 22 |
set in1_max 5.00 * 1.10 |
| 23 |
|
| 24 |
label in2 "AVCC" |
| 25 |
set in2_min 3.30 * 0.90 |
| 26 |
set in2_max 3.30 * 1.10 |
| 27 |
|
| 28 |
label in3 "+3.3V" |
| 29 |
set in3_min 3.30 * 0.90 |
| 30 |
set in3_max 3.30 * 1.10 |
| 31 |
|
| 32 |
label in4 "+12.0V" |
| 33 |
compute in4 @*(66/10), @/(66/10) |
| 34 |
set in4_min 12.0 * 0.95 |
| 35 |
set in4_max 12.0 * 1.05 |
| 36 |
|
| 37 |
label in5 "VDDCR_SOC" |
| 38 |
set in5_min 0.80 |
| 39 |
set in5_max 1.20 |
| 40 |
|
| 41 |
label in6 "DRAMV" |
| 42 |
set in6_min 1.10 # DDR4 Underclocking |
| 43 |
set in6_max 1.50 # DDR4 Intel XMP2.0 recommended max safe voltage |
| 44 |
|
| 45 |
label in7 "3VSB" |
| 46 |
set in7_min 3.30 * 0.90 |
| 47 |
set in7_max 3.30 * 1.10 |
| 48 |
|
| 49 |
label in8 "VBAT" |
| 50 |
set in8_min 3.00 * 0.90 |
| 51 |
set in8_max 3.30 * 1.10 |
| 52 |
|
| 53 |
ignore in9 |
| 54 |
|
| 55 |
label in10 "VDDP" |
| 56 |
set in10_min 0.90 |
| 57 |
set in10_max 1.20 |
| 58 |
|
| 59 |
label in11 "+1.05V" |
| 60 |
set in11_min 1.05 * 0.9 |
| 61 |
set in11_max 1.05 * 1.1 |
| 62 |
|
| 63 |
ignore in12 |
| 64 |
ignore in13 |
| 65 |
|
| 66 |
label in14 "+1.8V" |
| 67 |
set in14_min 1.8 * 0.9 |
| 68 |
set in14_max 1.8 * 1.1 |
| 69 |
|
| 70 |
label fan1 "Chassis Fan 3" |
| 71 |
label fan2 "CPU Fan 1" |
| 72 |
set fan2_min 400 |
| 73 |
ignore fan3 |
| 74 |
label fan4 "Chassis Fan 1" |
| 75 |
label fan5 "Chassis Fan 2" |
| 76 |
|
| 77 |
label temp1 "Motherboard Temp" |
| 78 |
set temp1_max 55.0 |
| 79 |
set temp1_max_hyst 50.0 |
| 80 |
|
| 81 |
label temp2 "CPU Temp" |
| 82 |
|
| 83 |
ignore temp3 |
| 84 |
ignore temp4 |
| 85 |
ignore temp5 |
| 86 |
ignore temp6 |
| 87 |
ignore temp7 |
| 88 |
ignore temp8 |
| 89 |
ignore temp9 |
| 90 |
ignore temp10 |
| 91 |
|
| 92 |
ignore intrusion0 |
| 93 |
ignore intrusion1 |