Debian Codegraph @

tools/perf/pmu-events/arch/arm64/fujitsu/monaka/gcycle.json

raw
1 [
2 {
3 "EventCode": "0x0880",
4 "EventName": "GCYCLES",
5 "BriefDescription": "This event counts the number of cycles at 100MHz."
6 },
7 {
8 "EventCode": "0x0890",
9 "EventName": "FL0_GCYCLES",
10 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 0."
11 },
12 {
13 "EventCode": "0x0891",
14 "EventName": "FL1_GCYCLES",
15 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 1."
16 },
17 {
18 "EventCode": "0x0892",
19 "EventName": "FL2_GCYCLES",
20 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 2."
21 },
22 {
23 "EventCode": "0x0893",
24 "EventName": "FL3_GCYCLES",
25 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 3."
26 },
27 {
28 "EventCode": "0x0894",
29 "EventName": "FL4_GCYCLES",
30 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 4."
31 },
32 {
33 "EventCode": "0x0895",
34 "EventName": "FL5_GCYCLES",
35 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 5."
36 },
37 {
38 "EventCode": "0x0896",
39 "EventName": "FL6_GCYCLES",
40 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 6."
41 },
42 {
43 "EventCode": "0x0897",
44 "EventName": "FL7_GCYCLES",
45 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 7."
46 },
47 {
48 "EventCode": "0x0898",
49 "EventName": "FL8_GCYCLES",
50 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 8."
51 },
52 {
53 "EventCode": "0x0899",
54 "EventName": "FL9_GCYCLES",
55 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 9."
56 },
57 {
58 "EventCode": "0x089A",
59 "EventName": "FL10_GCYCLES",
60 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 10."
61 },
62 {
63 "EventCode": "0x089B",
64 "EventName": "FL11_GCYCLES",
65 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 11."
66 },
67 {
68 "EventCode": "0x089C",
69 "EventName": "FL12_GCYCLES",
70 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 12."
71 },
72 {
73 "EventCode": "0x089D",
74 "EventName": "FL13_GCYCLES",
75 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 13."
76 },
77 {
78 "EventCode": "0x089E",
79 "EventName": "FL14_GCYCLES",
80 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 14."
81 },
82 {
83 "EventCode": "0x089F",
84 "EventName": "FL15_GCYCLES",
85 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 15."
86 },
87 {
88 "EventCode": "0x08A0",
89 "EventName": "RETENTION_GCYCLES",
90 "BriefDescription": "This event counts the number of cycles where the measured core is staying in the RETENTION state."
91 },
92 {
93 "EventCode": "0x08A1",
94 "EventName": "RETENTION_COUNT",
95 "BriefDescription": "This event counts the number of changes from the normal state to the RETENTION state."
96 }
97 ]