| 1 |
# SPDX-License-Identifier: GPL-2.0 |
| 2 |
config PPC_PSERIES |
| 3 |
depends on PPC64 && PPC_BOOK3S |
| 4 |
bool "IBM pSeries & new (POWER5-based) iSeries" |
| 5 |
select HAVE_PCSPKR_PLATFORM |
| 6 |
select MPIC |
| 7 |
select OF_DYNAMIC |
| 8 |
select FORCE_PCI |
| 9 |
select PCI_MSI |
| 10 |
select IRQ_MSI_LIB |
| 11 |
select GENERIC_ALLOCATOR |
| 12 |
select PPC_XICS |
| 13 |
select PPC_XIVE_SPAPR |
| 14 |
select PPC_ICP_NATIVE |
| 15 |
select PPC_ICP_HV |
| 16 |
select PPC_ICS_RTAS |
| 17 |
select PPC_I8259 |
| 18 |
select PPC_RTAS |
| 19 |
select PPC_RTAS_DAEMON |
| 20 |
select RTAS_ERROR_LOGGING |
| 21 |
select PPC_UDBG_16550 |
| 22 |
select PPC_DOORBELL |
| 23 |
select HOTPLUG_CPU |
| 24 |
select FORCE_SMP |
| 25 |
select SWIOTLB |
| 26 |
select ARCH_SUPPORTS_PER_VMA_LOCK |
| 27 |
select PPC_RADIX_BROADCAST_TLBIE if PPC_RADIX_MMU |
| 28 |
default y |
| 29 |
|
| 30 |
config PARAVIRT |
| 31 |
bool |
| 32 |
|
| 33 |
config PARAVIRT_SPINLOCKS |
| 34 |
bool |
| 35 |
|
| 36 |
config PARAVIRT_TIME_ACCOUNTING |
| 37 |
select PARAVIRT |
| 38 |
bool |
| 39 |
|
| 40 |
config PPC_SPLPAR |
| 41 |
bool "Support for shared-processor logical partitions" |
| 42 |
depends on PPC_PSERIES |
| 43 |
select PARAVIRT_SPINLOCKS if PPC_QUEUED_SPINLOCKS |
| 44 |
select PARAVIRT_TIME_ACCOUNTING if VIRT_CPU_ACCOUNTING_GEN |
| 45 |
default y |
| 46 |
help |
| 47 |
Enabling this option will make the kernel run more efficiently |
| 48 |
on logically-partitioned pSeries systems which use shared |
| 49 |
processors, that is, which share physical processors between |
| 50 |
two or more partitions. |
| 51 |
|
| 52 |
Say Y if you are unsure. |
| 53 |
|
| 54 |
config DTL |
| 55 |
bool "Dispatch Trace Log" |
| 56 |
depends on PPC_SPLPAR && DEBUG_FS |
| 57 |
help |
| 58 |
SPLPAR machines can log hypervisor preempt & dispatch events to a |
| 59 |
kernel buffer. Saying Y here will enable logging these events, |
| 60 |
which are accessible through a debugfs file. |
| 61 |
|
| 62 |
Say N if you are unsure. |
| 63 |
|
| 64 |
config PSERIES_ENERGY |
| 65 |
tristate "pSeries energy management capabilities driver" |
| 66 |
depends on PPC_PSERIES |
| 67 |
default y |
| 68 |
help |
| 69 |
Provides interface to platform energy management capabilities |
| 70 |
on supported PSERIES platforms. |
| 71 |
Provides: /sys/devices/system/cpu/pseries_(de)activation_hint_list |
| 72 |
and /sys/devices/system/cpu/cpuN/pseries_(de)activation_hint |
| 73 |
|
| 74 |
config IO_EVENT_IRQ |
| 75 |
bool "IO Event Interrupt support" |
| 76 |
depends on PPC_PSERIES |
| 77 |
default y |
| 78 |
help |
| 79 |
Select this option, if you want to enable support for IO Event |
| 80 |
interrupts. IO event interrupt is a mechanism provided by RTAS |
| 81 |
to return information about hardware error and non-error events |
| 82 |
which may need OS attention. RTAS returns events for multiple |
| 83 |
event types and scopes. Device drivers can register their handlers |
| 84 |
to receive events. |
| 85 |
|
| 86 |
This option will only enable the IO event platform code. You |
| 87 |
will still need to enable or compile the actual drivers |
| 88 |
that use this infrastructure to handle IO event interrupts. |
| 89 |
|
| 90 |
Say Y if you are unsure. |
| 91 |
|
| 92 |
config LPARCFG |
| 93 |
bool "LPAR Configuration Data" |
| 94 |
depends on PPC_PSERIES |
| 95 |
help |
| 96 |
Provide system capacity information via human readable |
| 97 |
<key word>=<value> pairs through a /proc/ppc64/lparcfg interface. |
| 98 |
|
| 99 |
config PPC_PSERIES_DEBUG |
| 100 |
depends on PPC_PSERIES && PPC_EARLY_DEBUG |
| 101 |
bool "Enable extra debug logging in platforms/pseries" |
| 102 |
default y |
| 103 |
help |
| 104 |
Say Y here if you want the pseries core to produce a bunch of |
| 105 |
debug messages to the system log. Select this if you are having a |
| 106 |
problem with the pseries core and want to see more of what is |
| 107 |
going on. This does not enable debugging in lpar.c, which must |
| 108 |
be manually done due to its verbosity. |
| 109 |
|
| 110 |
config PPC_SMLPAR |
| 111 |
bool "Support for shared-memory logical partitions" |
| 112 |
depends on PPC_PSERIES |
| 113 |
select LPARCFG |
| 114 |
help |
| 115 |
Select this option to enable shared memory partition support. |
| 116 |
With this option a system running in an LPAR can be given more |
| 117 |
memory than physically available and will allow firmware to |
| 118 |
balance memory across many LPARs. |
| 119 |
|
| 120 |
config CMM |
| 121 |
tristate "Collaborative memory management" |
| 122 |
depends on PPC_SMLPAR |
| 123 |
select BALLOON |
| 124 |
default y |
| 125 |
help |
| 126 |
Select this option, if you want to enable the kernel interface |
| 127 |
to reduce the memory size of the system. This is accomplished |
| 128 |
by allocating pages of memory and put them "on hold". This only |
| 129 |
makes sense for a system running in an LPAR where the unused pages |
| 130 |
will be reused for other LPARs. The interface allows firmware to |
| 131 |
balance memory across many LPARs. |
| 132 |
|
| 133 |
config HTMDUMP |
| 134 |
tristate "PowerVM data dumper" |
| 135 |
depends on PPC_PSERIES && DEBUG_FS |
| 136 |
default m |
| 137 |
help |
| 138 |
Select this option, if you want to enable the kernel debugfs |
| 139 |
interface to dump the Hardware Trace Macro (HTM) function data |
| 140 |
in the LPAR. |
| 141 |
|
| 142 |
config HV_PERF_CTRS |
| 143 |
bool "Hypervisor supplied PMU events (24x7 & GPCI)" |
| 144 |
default y |
| 145 |
depends on PERF_EVENTS && PPC_PSERIES |
| 146 |
help |
| 147 |
Enable access to hypervisor supplied counters in perf. Currently, |
| 148 |
this enables code that uses the hcall GetPerfCounterInfo and 24x7 |
| 149 |
interfaces to retrieve counters. GPCI exists on Power 6 and later |
| 150 |
systems. 24x7 is available on Power 8 and later systems. |
| 151 |
|
| 152 |
If unsure, select Y. |
| 153 |
|
| 154 |
config VPA_PMU |
| 155 |
tristate "VPA PMU events" |
| 156 |
depends on KVM_BOOK3S_64_HV && HV_PERF_CTRS |
| 157 |
default m |
| 158 |
help |
| 159 |
Enable access to the VPA PMU counters via perf. This enables |
| 160 |
code that support measurement for KVM on PowerVM(KoP) feature. |
| 161 |
PAPR hypervisor has introduced three new counters in the VPA area |
| 162 |
of LPAR CPUs for KVM L2 guest observability. Two for context switches |
| 163 |
from host to guest and vice versa, and one counter for getting |
| 164 |
the total time spent inside the KVM guest. This config enables code |
| 165 |
that access these software counters via perf. |
| 166 |
|
| 167 |
If unsure, Select N. |
| 168 |
|
| 169 |
config IBMVIO |
| 170 |
depends on PPC_PSERIES |
| 171 |
bool |
| 172 |
default y |
| 173 |
|
| 174 |
config IBMEBUS |
| 175 |
depends on PPC_PSERIES && !CPU_LITTLE_ENDIAN |
| 176 |
bool "Support for GX bus based adapters" |
| 177 |
help |
| 178 |
Bus device driver for GX bus based adapters. |
| 179 |
|
| 180 |
config PSERIES_PLPKS |
| 181 |
depends on PPC_PSERIES |
| 182 |
select NLS |
| 183 |
bool |
| 184 |
# PowerVM provides an isolated Platform Keystore (PKS) storage |
| 185 |
# allocation for each LPAR with individually managed access |
| 186 |
# controls to store sensitive information securely. It can be |
| 187 |
# used to store asymmetric public keys or secrets as required |
| 188 |
# by different usecases. |
| 189 |
# |
| 190 |
# This option is selected by in-kernel consumers that require |
| 191 |
# access to the PKS. |
| 192 |
|
| 193 |
config PSERIES_PLPKS_SED |
| 194 |
depends on PPC_PSERIES |
| 195 |
bool |
| 196 |
# This option is selected by in-kernel consumers that require |
| 197 |
# access to the SED PKS keystore. |
| 198 |
|
| 199 |
config PAPR_SCM |
| 200 |
depends on PPC_PSERIES && MEMORY_HOTPLUG && LIBNVDIMM |
| 201 |
tristate "Support for the PAPR Storage Class Memory interface" |
| 202 |
help |
| 203 |
Enable access to hypervisor provided storage class memory. |
| 204 |
|
| 205 |
config PPC_SVM |
| 206 |
bool "Secure virtual machine (SVM) support for POWER" |
| 207 |
depends on PPC_PSERIES |
| 208 |
select SWIOTLB |
| 209 |
select ARCH_HAS_MEM_ENCRYPT |
| 210 |
select ARCH_HAS_FORCE_DMA_UNENCRYPTED |
| 211 |
select ARCH_HAS_CC_PLATFORM |
| 212 |
help |
| 213 |
There are certain POWER platforms which support secure guests using |
| 214 |
the Protected Execution Facility, with the help of an Ultravisor |
| 215 |
executing below the hypervisor layer. This enables support for |
| 216 |
those guests. |
| 217 |
|
| 218 |
If unsure, say "N". |