| 1 |
.TH THERMOMETER 8 |
| 2 |
# SPDX-License-Identifier: GPL-2.0 |
| 3 |
.SH NAME |
| 4 |
\fBthermometer\fP - A thermal profiling tool |
| 5 |
|
| 6 |
.SH SYNOPSIS |
| 7 |
.ft B |
| 8 |
.B thermometer |
| 9 |
.RB [ options ] |
| 10 |
.RB [ command ] |
| 11 |
.br |
| 12 |
.SH DESCRIPTION |
| 13 |
\fBthermometer \fP captures the thermal zones temperature at a |
| 14 |
specified sampling period. It is optimized to reduce as much as |
| 15 |
possible the overhead while doing the temperature acquisition in order |
| 16 |
to prevent disrupting the running application we may want to profile. |
| 17 |
|
| 18 |
This low overhead also allows a high rate sampling for the temperature |
| 19 |
which could be necessary to spot overshots and undershots. |
| 20 |
|
| 21 |
If no configuration file is specified, then all the thermal zones will |
| 22 |
be monitored at 4Hz, so every 250ms. A configuration file specifies |
| 23 |
the thermal zone names and the desired sampling period. A thermal zone |
| 24 |
name can be a regular expression to specify a group of thermal zone. |
| 25 |
|
| 26 |
The sampling of the different thermal zones will be written into |
| 27 |
separate files with the thermal zone name. It is possible to specify a |
| 28 |
postfix to identify them for example for a specific scenario. The |
| 29 |
output directory can be specified in addition. |
| 30 |
|
| 31 |
Without any parameters, \fBthermometer \fP captures all the thermal |
| 32 |
zone temperatures every 250ms and write to the current directory the |
| 33 |
captured files postfixed with the current date. |
| 34 |
|
| 35 |
If a running \fBduration\fP is specified or a \fBcommand\fP, the |
| 36 |
capture ends at the end of the duration if the command did not |
| 37 |
finished before. The \fBduration\fP can be specified alone as well as |
| 38 |
the \fBcommand\fP. If none is specified, the capture will continue |
| 39 |
indefinitively until interrupted by \fBSIGINT\fP or \fBSIGQUIT\fP. |
| 40 |
.PP |
| 41 |
|
| 42 |
.SS Options |
| 43 |
.PP |
| 44 |
The \fB-h, --help\fP option shows a short usage help |
| 45 |
.PP |
| 46 |
The \fB-o <dir>, --output <dir>\fP option defines the output directory to put the |
| 47 |
sampling files |
| 48 |
.PP |
| 49 |
The \fB-c <config>, --config <config>\fP option specifies the configuration file to use |
| 50 |
.PP |
| 51 |
The \fB-d <seconds>, --duration <seconds>\fP option specifies the duration of the capture |
| 52 |
.PP |
| 53 |
The \fB-l <loglevel>, --loglevel <loglevel>\fP option sets the loglevel [DEBUG,INFO,NOTICE,WARN,ERROR] |
| 54 |
.PP |
| 55 |
The \fB-p <string>, --postfix <string>\fP option appends \fBstring\fP at the end of the capture filenames |
| 56 |
.PP |
| 57 |
The \fB-s, --syslog\fP option sets the output to syslog, default is \fBstdout\fP |
| 58 |
.PP |
| 59 |
The \fB-w, --overwrite\fP overwrites the output files if they exist |
| 60 |
.PP |
| 61 |
|
| 62 |
.PP |
| 63 |
|
| 64 |
.SS "Exit status:" |
| 65 |
.TP |
| 66 |
0 |
| 67 |
if OK, |
| 68 |
.TP |
| 69 |
1 |
| 70 |
Error with the options specified as parameters |
| 71 |
.TP |
| 72 |
2 |
| 73 |
Error when configuring the logging facility |
| 74 |
.TP |
| 75 |
3 |
| 76 |
Error when configuring the time |
| 77 |
.TP |
| 78 |
4 |
| 79 |
Error in the initialization routine |
| 80 |
.TP |
| 81 |
5 |
| 82 |
Error during the runtime |
| 83 |
|
| 84 |
.SH Capture file format |
| 85 |
|
| 86 |
Every file contains two columns. The first one is the uptime timestamp |
| 87 |
in order to find a point in time since the system started up if there |
| 88 |
is any thermal event. The second one is the temperature in milli |
| 89 |
degree. The first line contains the label of each column. |
| 90 |
|
| 91 |
.SH AUTHOR |
| 92 |
Daniel Lezcano <[email protected]> |