| 1 |
# SPDX-License-Identifier: GPL-2.0-only |
| 2 |
menuconfig SND_SOC_SOF_TOPLEVEL |
| 3 |
bool "Sound Open Firmware (SOF) platforms" |
| 4 |
help |
| 5 |
This adds support for Sound Open Firmware (SOF). SOF is free and |
| 6 |
generic open source audio DSP firmware for multiple devices. |
| 7 |
Say Y if you have such a device that is supported by SOF. |
| 8 |
If unsure select "N". |
| 9 |
|
| 10 |
if SND_SOC_SOF_TOPLEVEL |
| 11 |
|
| 12 |
config SND_SOC_SOF_PCI_DEV |
| 13 |
tristate |
| 14 |
|
| 15 |
config SND_SOC_SOF_PCI |
| 16 |
tristate "SOF PCI enumeration support" |
| 17 |
depends on PCI |
| 18 |
help |
| 19 |
This adds support for PCI enumeration. This option is |
| 20 |
required to enable Intel Skylake+ devices. |
| 21 |
For backwards-compatibility with previous configurations the selection will |
| 22 |
be used as default for platform-specific drivers. |
| 23 |
Say Y if you need this option. |
| 24 |
If unsure select "N". |
| 25 |
|
| 26 |
config SND_SOC_SOF_ACPI |
| 27 |
tristate "SOF ACPI enumeration support" |
| 28 |
depends on ACPI || COMPILE_TEST |
| 29 |
help |
| 30 |
This adds support for ACPI enumeration. This option is required |
| 31 |
to enable Intel Broadwell/Baytrail/Cherrytrail devices. |
| 32 |
For backwards-compatibility with previous configurations the selection will |
| 33 |
be used as default for platform-specific drivers. |
| 34 |
Say Y if you need this option. |
| 35 |
If unsure select "N". |
| 36 |
|
| 37 |
config SND_SOC_SOF_ACPI_DEV |
| 38 |
tristate |
| 39 |
|
| 40 |
config SND_SOC_SOF_OF |
| 41 |
tristate "SOF OF enumeration support" |
| 42 |
depends on OF |
| 43 |
help |
| 44 |
This adds support for Device Tree enumeration. This option is |
| 45 |
required to enable i.MX8 or Mediatek devices. |
| 46 |
Say Y if you need this option. If unsure select "N". |
| 47 |
|
| 48 |
config SND_SOC_SOF_OF_DEV |
| 49 |
tristate |
| 50 |
|
| 51 |
config SND_SOC_SOF_COMPRESS |
| 52 |
bool |
| 53 |
select SND_SOC_COMPRESS |
| 54 |
|
| 55 |
config SND_SOC_SOF_DEBUG_PROBES |
| 56 |
tristate |
| 57 |
select SND_SOC_SOF_CLIENT |
| 58 |
select SND_SOC_COMPRESS |
| 59 |
help |
| 60 |
This option enables the data probing feature that can be used to |
| 61 |
gather data directly from specific points of the audio pipeline. |
| 62 |
This option is not user-selectable but automagically handled by |
| 63 |
'select' statements at a higher level. |
| 64 |
|
| 65 |
config SND_SOC_SOF_CLIENT |
| 66 |
tristate |
| 67 |
select AUXILIARY_BUS |
| 68 |
help |
| 69 |
This option is not user-selectable but automagically handled by |
| 70 |
'select' statements at a higher level. |
| 71 |
|
| 72 |
config SND_SOC_SOF_DEVELOPER_SUPPORT |
| 73 |
bool "SOF developer options support" |
| 74 |
depends on EXPERT && SND_SOC_SOF |
| 75 |
help |
| 76 |
This option unlocks SOF developer options for debug/performance/ |
| 77 |
code hardening. |
| 78 |
Distributions should not select this option, only SOF development |
| 79 |
teams should select it. |
| 80 |
Say Y if you are involved in SOF development and need this option. |
| 81 |
If not, select N. |
| 82 |
|
| 83 |
if SND_SOC_SOF_DEVELOPER_SUPPORT |
| 84 |
|
| 85 |
config SND_SOC_SOF_FORCE_PROBE_WORKQUEUE |
| 86 |
bool "SOF force probe workqueue" |
| 87 |
select SND_SOC_SOF_PROBE_WORK_QUEUE |
| 88 |
help |
| 89 |
This option forces the use of a probe workqueue, which is only used |
| 90 |
when HDaudio is enabled due to module dependencies. Forcing this |
| 91 |
option is intended for debug only, but this should not add any |
| 92 |
functional issues in nominal cases. |
| 93 |
Say Y if you are involved in SOF development and need this option. |
| 94 |
If not, select N. |
| 95 |
|
| 96 |
config SND_SOC_SOF_NOCODEC |
| 97 |
tristate |
| 98 |
|
| 99 |
config SND_SOC_SOF_NOCODEC_SUPPORT |
| 100 |
bool "SOF nocodec static mode support" |
| 101 |
help |
| 102 |
This adds support for a dummy/nocodec machine driver fallback |
| 103 |
option if no known codec is detected. This is typically only |
| 104 |
enabled for developers or devices where the sound card is |
| 105 |
controlled externally. |
| 106 |
This option is mutually exclusive at build time with the Intel HDAudio support. |
| 107 |
Selecting it may have negative impacts and prevent e.g. microphone |
| 108 |
functionality from being enabled on Intel CoffeeLake and later |
| 109 |
platforms. |
| 110 |
Distributions should not select this option! |
| 111 |
Say Y if you need this nocodec fallback option. |
| 112 |
If unsure select "N". |
| 113 |
|
| 114 |
config SND_SOC_SOF_STRICT_ABI_CHECKS |
| 115 |
bool "SOF strict ABI checks" |
| 116 |
help |
| 117 |
This option enables strict ABI checks for firmware and topology |
| 118 |
files. |
| 119 |
When these files are more recent than the kernel, the kernel |
| 120 |
will handle the functionality it supports and may report errors |
| 121 |
during topology creation or run-time usage if new functionality |
| 122 |
is invoked. |
| 123 |
This option will stop topology creation and firmware load upfront. |
| 124 |
It is intended for SOF CI/releases and not for users or distros. |
| 125 |
Say Y if you want strict ABI checks for an SOF release. |
| 126 |
If you are not involved in SOF releases and CI development, |
| 127 |
select "N". |
| 128 |
|
| 129 |
config SND_SOC_SOF_ALLOW_FALLBACK_TO_NEWER_IPC_VERSION |
| 130 |
bool "SOF allow fallback to newer IPC version" |
| 131 |
help |
| 132 |
This option will allow the kernel to try to 'fallback' to a newer IPC |
| 133 |
version if there are missing firmware files to satisfy the default IPC |
| 134 |
version. |
| 135 |
IPC version fallback to older versions is not affected by this option, |
| 136 |
it is always available. |
| 137 |
Say Y if you are involved in SOF development and need this option. |
| 138 |
If not, select N. |
| 139 |
|
| 140 |
config SND_SOC_SOF_DEBUG |
| 141 |
bool "SOF debugging features" |
| 142 |
help |
| 143 |
This option can be used to enable or disable individual SOF firmware |
| 144 |
and driver debugging options. |
| 145 |
Say Y if you are debugging SOF FW or drivers. |
| 146 |
If unsure select "N". |
| 147 |
|
| 148 |
if SND_SOC_SOF_DEBUG |
| 149 |
|
| 150 |
config SND_SOC_SOF_NOCODEC_DEBUG_SUPPORT |
| 151 |
bool "SOF nocodec debug mode support" |
| 152 |
depends on !SND_SOC_SOF_NOCODEC_SUPPORT |
| 153 |
help |
| 154 |
This adds support for a dummy/nocodec machine driver fallback |
| 155 |
option. |
| 156 |
Unlike the SND_SOC_SOF_NOCODEC_SUPPORT, this option is NOT |
| 157 |
mutually exclusive at build with the Intel HDAudio support. The |
| 158 |
selection will be done depending on command line or modprobe.d settings |
| 159 |
Distributions should not select this option! |
| 160 |
Say Y if you need this nocodec debug fallback option. |
| 161 |
If unsure select "N". |
| 162 |
|
| 163 |
config SND_SOC_SOF_FORCE_NOCODEC_MODE |
| 164 |
bool "SOF force nocodec Mode" |
| 165 |
depends on SND_SOC_SOF_NOCODEC_SUPPORT |
| 166 |
help |
| 167 |
This forces SOF to use dummy/nocodec as machine driver, even |
| 168 |
though there is a codec detected on the real platform. This is |
| 169 |
typically only enabled for developers for debug purposes, before |
| 170 |
codec/machine driver is ready, or to exclude the impact of those |
| 171 |
drivers. |
| 172 |
Say Y if you need this force nocodec mode option. |
| 173 |
If unsure select "N". |
| 174 |
|
| 175 |
config SND_SOC_SOF_DEBUG_XRUN_STOP |
| 176 |
bool "SOF stop on XRUN" |
| 177 |
help |
| 178 |
This option forces PCMs to stop on any XRUN event. This is useful to |
| 179 |
preserve any trace data and pipeline status prior to the XRUN. |
| 180 |
Say Y if you are debugging SOF FW pipeline XRUNs. |
| 181 |
If unsure select "N". |
| 182 |
|
| 183 |
config SND_SOC_SOF_DEBUG_VERBOSE_IPC |
| 184 |
bool "SOF verbose IPC logs" |
| 185 |
help |
| 186 |
This option enables more verbose IPC logs, with command types in |
| 187 |
human-readable form instead of just 32-bit hex dumps. This is useful |
| 188 |
if you are trying to debug IPC with the DSP firmware. |
| 189 |
If unsure select "N". |
| 190 |
|
| 191 |
config SND_SOC_SOF_DEBUG_FORCE_IPC_POSITION |
| 192 |
bool "SOF force to use IPC for position update on SKL+" |
| 193 |
help |
| 194 |
This option forces to handle stream position update IPCs and run PCM |
| 195 |
elapse to inform ALSA about that, on platforms (e.g. Intel SKL+) that |
| 196 |
with other approach (e.g. HDAC DPIB/posbuf) to elapse PCM. |
| 197 |
On platforms (e.g. Intel SKL-) where position update IPC is the only |
| 198 |
one choice, this setting won't impact anything. |
| 199 |
If you are trying to debug pointer update with position IPCs or where |
| 200 |
DPIB/posbuf is not ready, select "Y". |
| 201 |
If unsure select "N". |
| 202 |
|
| 203 |
config SND_SOC_SOF_DEBUG_ENABLE_DEBUGFS_CACHE |
| 204 |
bool "SOF enable debugfs caching" |
| 205 |
help |
| 206 |
This option enables caching of debugfs |
| 207 |
memory -> DSP resource (memory, register, etc) |
| 208 |
before the audio DSP is suspended. This will increase the suspend |
| 209 |
latency and therefore should be used for debug purposes only. |
| 210 |
Say Y if you want to enable caching the memory windows. |
| 211 |
If unsure, select "N". |
| 212 |
|
| 213 |
config SND_SOC_SOF_DEBUG_ENABLE_FIRMWARE_TRACE |
| 214 |
bool "SOF enable firmware trace" |
| 215 |
help |
| 216 |
The firmware trace can be enabled either at build-time with |
| 217 |
this option, or dynamically by setting flags in the SOF core |
| 218 |
module parameter (similar to dynamic debug). |
| 219 |
If unsure, select "N". |
| 220 |
|
| 221 |
config SND_SOC_SOF_DEBUG_IPC_FLOOD_TEST |
| 222 |
tristate "SOF enable IPC flood test" |
| 223 |
depends on SND_SOC_SOF |
| 224 |
select SND_SOC_SOF_CLIENT |
| 225 |
help |
| 226 |
This option enables a separate client device for IPC flood test |
| 227 |
which can be used to flood the DSP with test IPCs and gather stats |
| 228 |
about response times. |
| 229 |
Say Y if you want to enable IPC flood test. |
| 230 |
If unsure, select "N". |
| 231 |
|
| 232 |
config SND_SOC_SOF_DEBUG_IPC_FLOOD_TEST_NUM |
| 233 |
int "Number of IPC flood test clients" |
| 234 |
range 1 32 |
| 235 |
default 2 |
| 236 |
depends on SND_SOC_SOF_DEBUG_IPC_FLOOD_TEST |
| 237 |
help |
| 238 |
Select the number of IPC flood test clients to be created. |
| 239 |
|
| 240 |
config SND_SOC_SOF_DEBUG_IPC_MSG_INJECTOR |
| 241 |
tristate "SOF enable IPC message injector" |
| 242 |
depends on SND_SOC_SOF |
| 243 |
select SND_SOC_SOF_CLIENT |
| 244 |
help |
| 245 |
This option enables the IPC message injector which can be used to send |
| 246 |
crafted IPC messages to the DSP to test its robustness. |
| 247 |
Say Y if you want to enable the IPC message injector. |
| 248 |
If unsure, select "N". |
| 249 |
|
| 250 |
config SND_SOC_SOF_DEBUG_IPC_KERNEL_INJECTOR |
| 251 |
tristate "SOF enable IPC kernel injector" |
| 252 |
depends on SND_SOC_SOF |
| 253 |
select SND_SOC_SOF_CLIENT |
| 254 |
help |
| 255 |
This option enables the IPC kernel injector which can be used to send |
| 256 |
crafted IPC messages to the kernel to test its robustness against |
| 257 |
DSP messages. |
| 258 |
Say Y if you want to enable the IPC kernel injector. |
| 259 |
If unsure, select "N". |
| 260 |
|
| 261 |
config SND_SOC_SOF_DEBUG_RETAIN_DSP_CONTEXT |
| 262 |
bool "SOF retain DSP context on any FW exceptions" |
| 263 |
help |
| 264 |
This option keeps the DSP in D0 state so that firmware debug |
| 265 |
information can be retained and dumped to userspace. |
| 266 |
Say Y if you want to retain DSP context for FW exceptions. |
| 267 |
If unsure, select "N". |
| 268 |
|
| 269 |
endif ## SND_SOC_SOF_DEBUG |
| 270 |
|
| 271 |
endif ## SND_SOC_SOF_DEVELOPER_SUPPORT |
| 272 |
|
| 273 |
config SND_SOC_SOF |
| 274 |
tristate |
| 275 |
select SND_SOC_TOPOLOGY |
| 276 |
select SND_SOC_SOF_NOCODEC if SND_SOC_SOF_NOCODEC_SUPPORT |
| 277 |
select SND_SOC_SOF_NOCODEC if SND_SOC_SOF_NOCODEC_DEBUG_SUPPORT |
| 278 |
help |
| 279 |
This option is not user-selectable but automagically handled by |
| 280 |
'select' statements at a higher level. |
| 281 |
The selection is made at the top level and does not exactly follow |
| 282 |
module dependencies but since the module or built-in type is decided |
| 283 |
at the top level it doesn't matter. |
| 284 |
|
| 285 |
config SND_SOC_SOF_PROBE_WORK_QUEUE |
| 286 |
bool |
| 287 |
help |
| 288 |
This option is not user-selectable but automagically handled by |
| 289 |
'select' statements at a higher level. |
| 290 |
When selected, the probe is handled in two steps, for example to |
| 291 |
avoid lockdeps if request_module is used in the probe. |
| 292 |
|
| 293 |
# Supported IPC versions |
| 294 |
config SND_SOC_SOF_IPC3 |
| 295 |
bool |
| 296 |
|
| 297 |
config SND_SOC_SOF_IPC4 |
| 298 |
bool |
| 299 |
|
| 300 |
source "sound/soc/sof/amd/Kconfig" |
| 301 |
source "sound/soc/sof/imx/Kconfig" |
| 302 |
source "sound/soc/sof/intel/Kconfig" |
| 303 |
source "sound/soc/sof/mediatek/Kconfig" |
| 304 |
source "sound/soc/sof/xtensa/Kconfig" |
| 305 |
|
| 306 |
endif |