| 1 |
// SPDX-License-Identifier: GPL-2.0 |
| 2 |
/* |
| 3 |
* nvec_power: power supply driver for a NVIDIA compliant embedded controller |
| 4 |
* |
| 5 |
* Copyright (C) 2011 The AC100 Kernel Team <[email protected]> |
| 6 |
* |
| 7 |
* Authors: Ilya Petrov <[email protected]> |
| 8 |
* Marc Dietrich <[email protected]> |
| 9 |
*/ |
| 10 |
|
| 11 |
#include <linux/module.h> |
| 12 |
#include <linux/platform_device.h> |
| 13 |
#include <linux/err.h> |
| 14 |
#include <linux/power_supply.h> |
| 15 |
#include <linux/slab.h> |
| 16 |
#include <linux/workqueue.h> |
| 17 |
#include <linux/delay.h> |
| 18 |
|
| 19 |
#include "nvec.h" |
| 20 |
|
| 21 |
#define GET_SYSTEM_STATUS 0x00 |
| 22 |
|
| 23 |
struct nvec_power { |
| 24 |
struct notifier_block notifier; |
| 25 |
struct delayed_work poller; |
| 26 |
struct nvec_chip *nvec; |
| 27 |
int on; |
| 28 |
int bat_present; |
| 29 |
int bat_status; |
| 30 |
int bat_voltage_now; |
| 31 |
int bat_current_now; |
| 32 |
int bat_current_avg; |
| 33 |
int time_remain; |
| 34 |
int charge_full_design; |
| 35 |
int charge_last_full; |
| 36 |
int critical_capacity; |
| 37 |
int capacity_remain; |
| 38 |
int bat_temperature; |
| 39 |
int bat_cap; |
| 40 |
int bat_type_enum; |
| 41 |
char bat_manu[30]; |
| 42 |
char bat_model[30]; |
| 43 |
char bat_type[30]; |
| 44 |
}; |
| 45 |
|
| 46 |
enum { |
| 47 |
SLOT_STATUS, |
| 48 |
VOLTAGE, |
| 49 |
TIME_REMAINING, |
| 50 |
CURRENT, |
| 51 |
AVERAGE_CURRENT, |
| 52 |
AVERAGING_TIME_INTERVAL, |
| 53 |
CAPACITY_REMAINING, |
| 54 |
LAST_FULL_CHARGE_CAPACITY, |
| 55 |
DESIGN_CAPACITY, |
| 56 |
CRITICAL_CAPACITY, |
| 57 |
TEMPERATURE, |
| 58 |
MANUFACTURER, |
| 59 |
MODEL, |
| 60 |
TYPE, |
| 61 |
}; |
| 62 |
|
| 63 |
enum { |
| 64 |
AC, |
| 65 |
BAT, |
| 66 |
}; |
| 67 |
|
| 68 |
struct bat_response { |
| 69 |
u8 event_type; |
| 70 |
u8 length; |
| 71 |
u8 sub_type; |
| 72 |
u8 status; |
| 73 |
/* payload */ |
| 74 |
union { |
| 75 |
char plc[30]; |
| 76 |
u16 plu; |
| 77 |
s16 pls; |
| 78 |
}; |
| 79 |
}; |
| 80 |
|
| 81 |
static struct power_supply *nvec_bat_psy; |
| 82 |
static struct power_supply *nvec_psy; |
| 83 |
|
| 84 |
static int nvec_power_notifier(struct notifier_block *nb, |
| 85 |
unsigned long event_type, void *data) |
| 86 |
{ |
| 87 |
struct nvec_power *power = |
| 88 |
container_of(nb, struct nvec_power, notifier); |
| 89 |
struct bat_response *res = data; |
| 90 |
|
| 91 |
if (event_type != NVEC_SYS) |
| 92 |
return NOTIFY_DONE; |
| 93 |
|
| 94 |
if (res->sub_type == 0) { |
| 95 |
if (power->on != res->plu) { |
| 96 |
power->on = res->plu; |
| 97 |
power_supply_changed(nvec_psy); |
| 98 |
} |
| 99 |
return NOTIFY_STOP; |
| 100 |
} |
| 101 |
return NOTIFY_OK; |
| 102 |
} |
| 103 |
|
| 104 |
static const int bat_init[] = { |
| 105 |
LAST_FULL_CHARGE_CAPACITY, DESIGN_CAPACITY, CRITICAL_CAPACITY, |
| 106 |
MANUFACTURER, MODEL, TYPE, |
| 107 |
}; |
| 108 |
|
| 109 |
static void get_bat_mfg_data(struct nvec_power *power) |
| 110 |
{ |
| 111 |
int i; |
| 112 |
char buf[] = { NVEC_BAT, SLOT_STATUS }; |
| 113 |
|
| 114 |
for (i = 0; i < ARRAY_SIZE(bat_init); i++) { |
| 115 |
buf[1] = bat_init[i]; |
| 116 |
nvec_write_async(power->nvec, buf, 2); |
| 117 |
} |
| 118 |
} |
| 119 |
|
| 120 |
static int nvec_power_bat_notifier(struct notifier_block *nb, |
| 121 |
unsigned long event_type, void *data) |
| 122 |
{ |
| 123 |
struct nvec_power *power = |
| 124 |
container_of(nb, struct nvec_power, notifier); |
| 125 |
struct bat_response *res = data; |
| 126 |
int status_changed = 0; |
| 127 |
|
| 128 |
if (event_type != NVEC_BAT) |
| 129 |
return NOTIFY_DONE; |
| 130 |
|
| 131 |
switch (res->sub_type) { |
| 132 |
case SLOT_STATUS: |
| 133 |
if (res->plc[0] & 1) { |
| 134 |
if (power->bat_present == 0) { |
| 135 |
status_changed = 1; |
| 136 |
get_bat_mfg_data(power); |
| 137 |
} |
| 138 |
|
| 139 |
power->bat_present = 1; |
| 140 |
|
| 141 |
switch ((res->plc[0] >> 1) & 3) { |
| 142 |
case 0: |
| 143 |
power->bat_status = |
| 144 |
POWER_SUPPLY_STATUS_NOT_CHARGING; |
| 145 |
break; |
| 146 |
case 1: |
| 147 |
power->bat_status = |
| 148 |
POWER_SUPPLY_STATUS_CHARGING; |
| 149 |
break; |
| 150 |
case 2: |
| 151 |
power->bat_status = |
| 152 |
POWER_SUPPLY_STATUS_DISCHARGING; |
| 153 |
break; |
| 154 |
default: |
| 155 |
power->bat_status = POWER_SUPPLY_STATUS_UNKNOWN; |
| 156 |
} |
| 157 |
} else { |
| 158 |
if (power->bat_present == 1) |
| 159 |
status_changed = 1; |
| 160 |
|
| 161 |
power->bat_present = 0; |
| 162 |
power->bat_status = POWER_SUPPLY_STATUS_UNKNOWN; |
| 163 |
} |
| 164 |
power->bat_cap = res->plc[1]; |
| 165 |
if (status_changed) |
| 166 |
power_supply_changed(nvec_bat_psy); |
| 167 |
break; |
| 168 |
case VOLTAGE: |
| 169 |
power->bat_voltage_now = res->plu * 1000; |
| 170 |
break; |
| 171 |
case TIME_REMAINING: |
| 172 |
power->time_remain = res->plu * 3600; |
| 173 |
break; |
| 174 |
case CURRENT: |
| 175 |
power->bat_current_now = res->pls * 1000; |
| 176 |
break; |
| 177 |
case AVERAGE_CURRENT: |
| 178 |
power->bat_current_avg = res->pls * 1000; |
| 179 |
break; |
| 180 |
case CAPACITY_REMAINING: |
| 181 |
power->capacity_remain = res->plu * 1000; |
| 182 |
break; |
| 183 |
case LAST_FULL_CHARGE_CAPACITY: |
| 184 |
power->charge_last_full = res->plu * 1000; |
| 185 |
break; |
| 186 |
case DESIGN_CAPACITY: |
| 187 |
power->charge_full_design = res->plu * 1000; |
| 188 |
break; |
| 189 |
case CRITICAL_CAPACITY: |
| 190 |
power->critical_capacity = res->plu * 1000; |
| 191 |
break; |
| 192 |
case TEMPERATURE: |
| 193 |
power->bat_temperature = res->plu - 2732; |
| 194 |
break; |
| 195 |
case MANUFACTURER: |
| 196 |
memcpy(power->bat_manu, &res->plc, res->length - 2); |
| 197 |
power->bat_manu[res->length - 2] = '\0'; |
| 198 |
break; |
| 199 |
case MODEL: |
| 200 |
memcpy(power->bat_model, &res->plc, res->length - 2); |
| 201 |
power->bat_model[res->length - 2] = '\0'; |
| 202 |
break; |
| 203 |
case TYPE: |
| 204 |
memcpy(power->bat_type, &res->plc, res->length - 2); |
| 205 |
power->bat_type[res->length - 2] = '\0'; |
| 206 |
/* |
| 207 |
* This differs a little from the spec fill in more if you find |
| 208 |
* some. |
| 209 |
*/ |
| 210 |
if (!strncmp(power->bat_type, "Li", 30)) |
| 211 |
power->bat_type_enum = POWER_SUPPLY_TECHNOLOGY_LION; |
| 212 |
else |
| 213 |
power->bat_type_enum = POWER_SUPPLY_TECHNOLOGY_UNKNOWN; |
| 214 |
break; |
| 215 |
default: |
| 216 |
return NOTIFY_STOP; |
| 217 |
} |
| 218 |
|
| 219 |
return NOTIFY_STOP; |
| 220 |
} |
| 221 |
|
| 222 |
static int nvec_power_get_property(struct power_supply *psy, |
| 223 |
enum power_supply_property psp, |
| 224 |
union power_supply_propval *val) |
| 225 |
{ |
| 226 |
struct nvec_power *power = dev_get_drvdata(psy->dev.parent); |
| 227 |
|
| 228 |
switch (psp) { |
| 229 |
case POWER_SUPPLY_PROP_ONLINE: |
| 230 |
val->intval = power->on; |
| 231 |
break; |
| 232 |
default: |
| 233 |
return -EINVAL; |
| 234 |
} |
| 235 |
return 0; |
| 236 |
} |
| 237 |
|
| 238 |
static int nvec_battery_get_property(struct power_supply *psy, |
| 239 |
enum power_supply_property psp, |
| 240 |
union power_supply_propval *val) |
| 241 |
{ |
| 242 |
struct nvec_power *power = dev_get_drvdata(psy->dev.parent); |
| 243 |
|
| 244 |
switch (psp) { |
| 245 |
case POWER_SUPPLY_PROP_STATUS: |
| 246 |
val->intval = power->bat_status; |
| 247 |
break; |
| 248 |
case POWER_SUPPLY_PROP_CAPACITY: |
| 249 |
val->intval = power->bat_cap; |
| 250 |
break; |
| 251 |
case POWER_SUPPLY_PROP_PRESENT: |
| 252 |
val->intval = power->bat_present; |
| 253 |
break; |
| 254 |
case POWER_SUPPLY_PROP_VOLTAGE_NOW: |
| 255 |
val->intval = power->bat_voltage_now; |
| 256 |
break; |
| 257 |
case POWER_SUPPLY_PROP_CURRENT_NOW: |
| 258 |
val->intval = power->bat_current_now; |
| 259 |
break; |
| 260 |
case POWER_SUPPLY_PROP_CURRENT_AVG: |
| 261 |
val->intval = power->bat_current_avg; |
| 262 |
break; |
| 263 |
case POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW: |
| 264 |
val->intval = power->time_remain; |
| 265 |
break; |
| 266 |
case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN: |
| 267 |
val->intval = power->charge_full_design; |
| 268 |
break; |
| 269 |
case POWER_SUPPLY_PROP_CHARGE_FULL: |
| 270 |
val->intval = power->charge_last_full; |
| 271 |
break; |
| 272 |
case POWER_SUPPLY_PROP_CHARGE_EMPTY: |
| 273 |
val->intval = power->critical_capacity; |
| 274 |
break; |
| 275 |
case POWER_SUPPLY_PROP_CHARGE_NOW: |
| 276 |
val->intval = power->capacity_remain; |
| 277 |
break; |
| 278 |
case POWER_SUPPLY_PROP_TEMP: |
| 279 |
val->intval = power->bat_temperature; |
| 280 |
break; |
| 281 |
case POWER_SUPPLY_PROP_MANUFACTURER: |
| 282 |
val->strval = power->bat_manu; |
| 283 |
break; |
| 284 |
case POWER_SUPPLY_PROP_MODEL_NAME: |
| 285 |
val->strval = power->bat_model; |
| 286 |
break; |
| 287 |
case POWER_SUPPLY_PROP_TECHNOLOGY: |
| 288 |
val->intval = power->bat_type_enum; |
| 289 |
break; |
| 290 |
default: |
| 291 |
return -EINVAL; |
| 292 |
} |
| 293 |
return 0; |
| 294 |
} |
| 295 |
|
| 296 |
static enum power_supply_property nvec_power_props[] = { |
| 297 |
POWER_SUPPLY_PROP_ONLINE, |
| 298 |
}; |
| 299 |
|
| 300 |
static enum power_supply_property nvec_battery_props[] = { |
| 301 |
POWER_SUPPLY_PROP_STATUS, |
| 302 |
POWER_SUPPLY_PROP_PRESENT, |
| 303 |
POWER_SUPPLY_PROP_CAPACITY, |
| 304 |
POWER_SUPPLY_PROP_VOLTAGE_NOW, |
| 305 |
POWER_SUPPLY_PROP_CURRENT_NOW, |
| 306 |
#ifdef EC_FULL_DIAG |
| 307 |
POWER_SUPPLY_PROP_CURRENT_AVG, |
| 308 |
POWER_SUPPLY_PROP_TEMP, |
| 309 |
POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW, |
| 310 |
#endif |
| 311 |
POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN, |
| 312 |
POWER_SUPPLY_PROP_CHARGE_FULL, |
| 313 |
POWER_SUPPLY_PROP_CHARGE_EMPTY, |
| 314 |
POWER_SUPPLY_PROP_CHARGE_NOW, |
| 315 |
POWER_SUPPLY_PROP_MANUFACTURER, |
| 316 |
POWER_SUPPLY_PROP_MODEL_NAME, |
| 317 |
POWER_SUPPLY_PROP_TECHNOLOGY, |
| 318 |
}; |
| 319 |
|
| 320 |
static char *nvec_power_supplied_to[] = { |
| 321 |
"battery", |
| 322 |
}; |
| 323 |
|
| 324 |
static const struct power_supply_desc nvec_bat_psy_desc = { |
| 325 |
.name = "battery", |
| 326 |
.type = POWER_SUPPLY_TYPE_BATTERY, |
| 327 |
.properties = nvec_battery_props, |
| 328 |
.num_properties = ARRAY_SIZE(nvec_battery_props), |
| 329 |
.get_property = nvec_battery_get_property, |
| 330 |
}; |
| 331 |
|
| 332 |
static const struct power_supply_desc nvec_psy_desc = { |
| 333 |
.name = "ac", |
| 334 |
.type = POWER_SUPPLY_TYPE_MAINS, |
| 335 |
.properties = nvec_power_props, |
| 336 |
.num_properties = ARRAY_SIZE(nvec_power_props), |
| 337 |
.get_property = nvec_power_get_property, |
| 338 |
}; |
| 339 |
|
| 340 |
static int counter; |
| 341 |
static const int bat_iter[] = { |
| 342 |
SLOT_STATUS, VOLTAGE, CURRENT, CAPACITY_REMAINING, |
| 343 |
#ifdef EC_FULL_DIAG |
| 344 |
AVERAGE_CURRENT, TEMPERATURE, TIME_REMAINING, |
| 345 |
#endif |
| 346 |
}; |
| 347 |
|
| 348 |
static void nvec_power_poll(struct work_struct *work) |
| 349 |
{ |
| 350 |
char buf[] = { NVEC_SYS, GET_SYSTEM_STATUS }; |
| 351 |
struct nvec_power *power = container_of(work, struct nvec_power, |
| 352 |
poller.work); |
| 353 |
|
| 354 |
if (counter >= ARRAY_SIZE(bat_iter)) |
| 355 |
counter = 0; |
| 356 |
|
| 357 |
/* AC status via sys req */ |
| 358 |
nvec_write_async(power->nvec, buf, 2); |
| 359 |
msleep(100); |
| 360 |
|
| 361 |
/* |
| 362 |
* Select a battery request function via round robin doing it all at |
| 363 |
* once seems to overload the power supply. |
| 364 |
*/ |
| 365 |
buf[0] = NVEC_BAT; |
| 366 |
buf[1] = bat_iter[counter++]; |
| 367 |
nvec_write_async(power->nvec, buf, 2); |
| 368 |
|
| 369 |
schedule_delayed_work(to_delayed_work(work), msecs_to_jiffies(5000)); |
| 370 |
}; |
| 371 |
|
| 372 |
static int nvec_power_probe(struct platform_device *pdev) |
| 373 |
{ |
| 374 |
struct power_supply **psy; |
| 375 |
const struct power_supply_desc *psy_desc; |
| 376 |
struct nvec_power *power; |
| 377 |
struct nvec_chip *nvec = dev_get_drvdata(pdev->dev.parent); |
| 378 |
struct power_supply_config psy_cfg = {}; |
| 379 |
|
| 380 |
power = devm_kzalloc(&pdev->dev, sizeof(struct nvec_power), GFP_NOWAIT); |
| 381 |
if (!power) |
| 382 |
return -ENOMEM; |
| 383 |
|
| 384 |
dev_set_drvdata(&pdev->dev, power); |
| 385 |
power->nvec = nvec; |
| 386 |
|
| 387 |
switch (pdev->id) { |
| 388 |
case AC: |
| 389 |
psy = &nvec_psy; |
| 390 |
psy_desc = &nvec_psy_desc; |
| 391 |
psy_cfg.supplied_to = nvec_power_supplied_to; |
| 392 |
psy_cfg.num_supplicants = ARRAY_SIZE(nvec_power_supplied_to); |
| 393 |
|
| 394 |
power->notifier.notifier_call = nvec_power_notifier; |
| 395 |
|
| 396 |
INIT_DELAYED_WORK(&power->poller, nvec_power_poll); |
| 397 |
schedule_delayed_work(&power->poller, msecs_to_jiffies(5000)); |
| 398 |
break; |
| 399 |
case BAT: |
| 400 |
psy = &nvec_bat_psy; |
| 401 |
psy_desc = &nvec_bat_psy_desc; |
| 402 |
|
| 403 |
power->notifier.notifier_call = nvec_power_bat_notifier; |
| 404 |
break; |
| 405 |
default: |
| 406 |
return -ENODEV; |
| 407 |
} |
| 408 |
|
| 409 |
nvec_register_notifier(nvec, &power->notifier, NVEC_SYS); |
| 410 |
|
| 411 |
if (pdev->id == BAT) |
| 412 |
get_bat_mfg_data(power); |
| 413 |
|
| 414 |
*psy = power_supply_register(&pdev->dev, psy_desc, &psy_cfg); |
| 415 |
|
| 416 |
return PTR_ERR_OR_ZERO(*psy); |
| 417 |
} |
| 418 |
|
| 419 |
static void nvec_power_remove(struct platform_device *pdev) |
| 420 |
{ |
| 421 |
struct nvec_power *power = platform_get_drvdata(pdev); |
| 422 |
|
| 423 |
cancel_delayed_work_sync(&power->poller); |
| 424 |
nvec_unregister_notifier(power->nvec, &power->notifier); |
| 425 |
switch (pdev->id) { |
| 426 |
case AC: |
| 427 |
power_supply_unregister(nvec_psy); |
| 428 |
break; |
| 429 |
case BAT: |
| 430 |
power_supply_unregister(nvec_bat_psy); |
| 431 |
} |
| 432 |
} |
| 433 |
|
| 434 |
static struct platform_driver nvec_power_driver = { |
| 435 |
.probe = nvec_power_probe, |
| 436 |
.remove = nvec_power_remove, |
| 437 |
.driver = { |
| 438 |
.name = "nvec-power", |
| 439 |
} |
| 440 |
}; |
| 441 |
|
| 442 |
module_platform_driver(nvec_power_driver); |
| 443 |
|
| 444 |
MODULE_AUTHOR("Ilya Petrov <[email protected]>"); |
| 445 |
MODULE_LICENSE("GPL"); |
| 446 |
MODULE_DESCRIPTION("NVEC battery and AC driver"); |
| 447 |
MODULE_ALIAS("platform:nvec-power"); |