| 1 |
What: /sys/bus/iio/devices/deviceX/inY-inZ_balance_switch_en |
| 2 |
KernelVersion: 3.0.0 |
| 3 |
Contact: [email protected] |
| 4 |
Description: |
| 5 |
Writing 1 enables the cell balance output switch corresponding |
| 6 |
to input Y. Writing 0 disables it. If the inY-inZ_balance_timer |
| 7 |
is set to a none zero value, the corresponding switch will |
| 8 |
enable for the programmed amount of time, before it |
| 9 |
automatically disables. |
| 10 |
|
| 11 |
What: /sys/bus/iio/devices/deviceX/inY-inZ_balance_timer |
| 12 |
KernelVersion: 3.0.0 |
| 13 |
Contact: [email protected] |
| 14 |
Description: |
| 15 |
The inY-inZ_balance_timer file allows the user to program |
| 16 |
individual times for each cell balance output. The AD7280A |
| 17 |
allows the user to set the timer to a value from 0 minutes to |
| 18 |
36.9 minutes. The resolution of the timer is 71.5 sec. |
| 19 |
The value written is the on-time in milliseconds. When the |
| 20 |
timer value is set 0, the timer is disabled. The cell balance |
| 21 |
outputs are controlled only by inY-inZ_balance_switch_en. |