| 1 |
=================================== |
| 2 |
Serial UART 16450/16550 MIDI driver |
| 3 |
=================================== |
| 4 |
|
| 5 |
The adaptor module parameter allows you to select either: |
| 6 |
|
| 7 |
* 0 - Roland Soundcanvas support (default) |
| 8 |
* 1 - Midiator MS-124T support (1) |
| 9 |
* 2 - Midiator MS-124W S/A mode (2) |
| 10 |
* 3 - MS-124W M/B mode support (3) |
| 11 |
* 4 - Generic device with multiple input support (4) |
| 12 |
|
| 13 |
For the Midiator MS-124W, you must set the physical M-S and A-B |
| 14 |
switches on the Midiator to match the driver mode you select. |
| 15 |
|
| 16 |
In Roland Soundcanvas mode, multiple ALSA raw MIDI substreams are supported |
| 17 |
(midiCnD0-midiCnD15). Whenever you write to a different substream, the driver |
| 18 |
sends the nonstandard MIDI command sequence F5 NN, where NN is the substream |
| 19 |
number plus 1. Roland modules use this command to switch between different |
| 20 |
"parts", so this feature lets you treat each part as a distinct raw MIDI |
| 21 |
substream. The driver provides no way to send F5 00 (no selection) or to not |
| 22 |
send the F5 NN command sequence at all; perhaps it ought to. |
| 23 |
|
| 24 |
Usage example for simple serial converter: |
| 25 |
:: |
| 26 |
|
| 27 |
/sbin/setserial /dev/ttyS0 uart none |
| 28 |
/sbin/modprobe snd-serial-u16550 port=0x3f8 irq=4 speed=115200 |
| 29 |
|
| 30 |
Usage example for Roland SoundCanvas with 4 MIDI ports: |
| 31 |
:: |
| 32 |
|
| 33 |
/sbin/setserial /dev/ttyS0 uart none |
| 34 |
/sbin/modprobe snd-serial-u16550 port=0x3f8 irq=4 outs=4 |
| 35 |
|
| 36 |
In MS-124T mode, one raw MIDI substream is supported (midiCnD0); the outs |
| 37 |
module parameter is automatically set to 1. The driver sends the same data to |
| 38 |
all four MIDI Out connectors. Set the A-B switch and the speed module |
| 39 |
parameter to match (A=19200, B=9600). |
| 40 |
|
| 41 |
Usage example for MS-124T, with A-B switch in A position: |
| 42 |
:: |
| 43 |
|
| 44 |
/sbin/setserial /dev/ttyS0 uart none |
| 45 |
/sbin/modprobe snd-serial-u16550 port=0x3f8 irq=4 adaptor=1 \ |
| 46 |
speed=19200 |
| 47 |
|
| 48 |
In MS-124W S/A mode, one raw MIDI substream is supported (midiCnD0); |
| 49 |
the outs module parameter is automatically set to 1. The driver sends |
| 50 |
the same data to all four MIDI Out connectors at full MIDI speed. |
| 51 |
|
| 52 |
Usage example for S/A mode: |
| 53 |
:: |
| 54 |
|
| 55 |
/sbin/setserial /dev/ttyS0 uart none |
| 56 |
/sbin/modprobe snd-serial-u16550 port=0x3f8 irq=4 adaptor=2 |
| 57 |
|
| 58 |
In MS-124W M/B mode, the driver supports 16 ALSA raw MIDI substreams; |
| 59 |
the outs module parameter is automatically set to 16. The substream |
| 60 |
number gives a bitmask of which MIDI Out connectors the data should be |
| 61 |
sent to, with midiCnD1 sending to Out 1, midiCnD2 to Out 2, midiCnD4 to |
| 62 |
Out 3, and midiCnD8 to Out 4. Thus midiCnD15 sends the data to all 4 ports. |
| 63 |
As a special case, midiCnD0 also sends to all ports, since it is not useful |
| 64 |
to send the data to no ports. M/B mode has extra overhead to select the MIDI |
| 65 |
Out for each byte, so the aggregate data rate across all four MIDI Outs is |
| 66 |
at most one byte every 520 us, as compared with the full MIDI data rate of |
| 67 |
one byte every 320 us per port. |
| 68 |
|
| 69 |
Usage example for M/B mode: |
| 70 |
:: |
| 71 |
|
| 72 |
/sbin/setserial /dev/ttyS0 uart none |
| 73 |
/sbin/modprobe snd-serial-u16550 port=0x3f8 irq=4 adaptor=3 |
| 74 |
|
| 75 |
The MS-124W hardware's M/A mode is currently not supported. This mode allows |
| 76 |
the MIDI Outs to act independently at double the aggregate throughput of M/B, |
| 77 |
but does not allow sending the same byte simultaneously to multiple MIDI Outs. |
| 78 |
The M/A protocol requires the driver to twiddle the modem control lines under |
| 79 |
timing constraints, so it would be a bit more complicated to implement than |
| 80 |
the other modes. |
| 81 |
|
| 82 |
Midiator models other than MS-124W and MS-124T are currently not supported. |
| 83 |
Note that the suffix letter is significant; the MS-124 and MS-124B are not |
| 84 |
compatible, nor are the other known models MS-101, MS-101B, MS-103, and MS-114. |
| 85 |
I do have documentation ([email protected]) that partially covers these models, |
| 86 |
but no units to experiment with. The MS-124W support is tested with a real unit. |
| 87 |
The MS-124T support is untested, but should work. |
| 88 |
|
| 89 |
The Generic driver supports multiple input and output substreams over a single |
| 90 |
serial port. Similar to Roland Soundcanvas mode, F5 NN is used to select the |
| 91 |
appropriate input or output stream (depending on the data direction). |
| 92 |
Additionally, the CTS signal is used to regulate the data flow. The number of |
| 93 |
inputs is specified by the ins parameter. |