Debian Codegraph @

Documentation/nvme/nvme-pci-endpoint-target.rst

raw
1 .. SPDX-License-Identifier: GPL-2.0
2
3 =================================
4 NVMe PCI Endpoint Function Target
5 =================================
6
7 :Author: Damien Le Moal <[email protected]>
8
9 The NVMe PCI endpoint function target driver implements an NVMe PCIe controller
10 using an NVMe fabrics target controller configured with the PCI transport type.
11
12 Overview
13 ========
14
15 The NVMe PCI endpoint function target driver allows exposing an NVMe target
16 controller over a PCIe link, thus implementing an NVMe PCIe device similar to a
17 regular M.2 SSD. The target controller is created in the same manner as when
18 using NVMe over fabrics: the controller represents the interface to an NVMe
19 subsystem using a port. The port transfer type must be configured to be
20 "pci". The subsystem can be configured to have namespaces backed by regular
21 files or block devices, or can use NVMe passthrough to expose to the PCI host an
22 existing physical NVMe device or an NVMe fabrics host controller (e.g. a NVMe
23 TCP host controller).
24
25 The NVMe PCI endpoint function target driver relies as much as possible on the
26 NVMe target core code to parse and execute NVMe commands submitted by the PCIe
27 host. However, using the PCI endpoint framework API and DMA API, the driver is
28 also responsible for managing all data transfers over the PCIe link. This
29 implies that the NVMe PCI endpoint function target driver implements several
30 NVMe data structure management and some NVMe command parsing.
31
32 1) The driver manages retrieval of NVMe commands in submission queues using DMA
33 if supported, or MMIO otherwise. Each command retrieved is then executed
34 using a work item to maximize performance with the parallel execution of
35 multiple commands on different CPUs. The driver uses a work item to
36 constantly poll the doorbell of all submission queues to detect command
37 submissions from the PCIe host.
38
39 2) The driver transfers completion queues entries of completed commands to the
40 PCIe host using MMIO copy of the entries in the host completion queue.
41 After posting completion entries in a completion queue, the driver uses the
42 PCI endpoint framework API to raise an interrupt to the host to signal the
43 commands completion.
44
45 3) For any command that has a data buffer, the NVMe PCI endpoint target driver
46 parses the command PRPs or SGLs lists to create a list of PCI address
47 segments representing the mapping of the command data buffer on the host.
48 The command data buffer is transferred over the PCIe link using this list of
49 PCI address segments using DMA, if supported. If DMA is not supported, MMIO
50 is used, which results in poor performance. For write commands, the command
51 data buffer is transferred from the host into a local memory buffer before
52 executing the command using the target core code. For read commands, a local
53 memory buffer is allocated to execute the command and the content of that
54 buffer is transferred to the host once the command completes.
55
56 Controller Capabilities
57 -----------------------
58
59 The NVMe capabilities exposed to the PCIe host through the BAR 0 registers
60 are almost identical to the capabilities of the NVMe target controller
61 implemented by the target core code. There are some exceptions.
62
63 1) The NVMe PCI endpoint target driver always sets the controller capability
64 CQR bit to request "Contiguous Queues Required". This is to facilitate the
65 mapping of a queue PCI address range to the local CPU address space.
66
67 2) The doorbell stride (DSTRB) is always set to be 4B
68
69 3) Since the PCI endpoint framework does not provide a way to handle PCI level
70 resets, the controller capability NSSR bit (NVM Subsystem Reset Supported)
71 is always cleared.
72
73 4) The boot partition support (BPS), Persistent Memory Region Supported (PMRS)
74 and Controller Memory Buffer Supported (CMBS) capabilities are never
75 reported.
76
77 Supported Features
78 ------------------
79
80 The NVMe PCI endpoint target driver implements support for both PRPs and SGLs.
81 The driver also implements IRQ vector coalescing and submission queue
82 arbitration burst.
83
84 The maximum number of queues and the maximum data transfer size (MDTS) are
85 configurable through configfs before starting the controller. To avoid issues
86 with excessive local memory usage for executing commands, MDTS defaults to 512
87 KB and is limited to a maximum of 2 MB (arbitrary limit).
88
89 Minimum number of PCI Address Mapping Windows Required
90 ------------------------------------------------------
91
92 Most PCI endpoint controllers provide a limited number of mapping windows for
93 mapping a PCI address range to local CPU memory addresses. The NVMe PCI
94 endpoint target controllers uses mapping windows for the following.
95
96 1) One memory window for raising MSI or MSI-X interrupts
97 2) One memory window for MMIO transfers
98 3) One memory window for each completion queue
99
100 Given the highly asynchronous nature of the NVMe PCI endpoint target driver
101 operation, the memory windows as described above will generally not be used
102 simultaneously, but that may happen. So a safe maximum number of completion
103 queues that can be supported is equal to the total number of memory mapping
104 windows of the PCI endpoint controller minus two. E.g. for an endpoint PCI
105 controller with 32 outbound memory windows available, up to 30 completion
106 queues can be safely operated without any risk of getting PCI address mapping
107 errors due to the lack of memory windows.
108
109 Maximum Number of Queue Pairs
110 -----------------------------
111
112 Upon binding of the NVMe PCI endpoint target driver to the PCI endpoint
113 controller, BAR 0 is allocated with enough space to accommodate the admin queue
114 and multiple I/O queues. The maximum of number of I/O queues pairs that can be
115 supported is limited by several factors.
116
117 1) The NVMe target core code limits the maximum number of I/O queues to the
118 number of online CPUs.
119 2) The total number of queue pairs, including the admin queue, cannot exceed
120 the number of MSI-X or MSI vectors available.
121 3) The total number of completion queues must not exceed the total number of
122 PCI mapping windows minus 2 (see above).
123
124 The NVMe endpoint function driver allows configuring the maximum number of
125 queue pairs through configfs.
126
127 Limitations and NVMe Specification Non-Compliance
128 -------------------------------------------------
129
130 Similar to the NVMe target core code, the NVMe PCI endpoint target driver does
131 not support multiple submission queues using the same completion queue. All
132 submission queues must specify a unique completion queue.
133
134
135 User Guide
136 ==========
137
138 This section describes the hardware requirements and how to setup an NVMe PCI
139 endpoint target device.
140
141 Kernel Requirements
142 -------------------
143
144 The kernel must be compiled with the configuration options CONFIG_PCI_ENDPOINT,
145 CONFIG_PCI_ENDPOINT_CONFIGFS, and CONFIG_NVME_TARGET_PCI_EPF enabled.
146 CONFIG_PCI, CONFIG_BLK_DEV_NVME and CONFIG_NVME_TARGET must also be enabled
147 (obviously).
148
149 In addition to this, at least one PCI endpoint controller driver should be
150 available for the endpoint hardware used.
151
152 To facilitate testing, enabling the null-blk driver (CONFIG_BLK_DEV_NULL_BLK)
153 is also recommended. With this, a simple setup using a null_blk block device
154 as a subsystem namespace can be used.
155
156 Hardware Requirements
157 ---------------------
158
159 To use the NVMe PCI endpoint target driver, at least one endpoint controller
160 device is required.
161
162 To find the list of endpoint controller devices in the system::
163
164 # ls /sys/class/pci_epc/
165 a40000000.pcie-ep
166
167 If PCI_ENDPOINT_CONFIGFS is enabled::
168
169 # ls /sys/kernel/config/pci_ep/controllers
170 a40000000.pcie-ep
171
172 The endpoint board must of course also be connected to a host with a PCI cable
173 with RX-TX signal swapped. If the host PCI slot used does not have
174 plug-and-play capabilities, the host should be powered off when the NVMe PCI
175 endpoint device is configured.
176
177 NVMe Endpoint Device
178 --------------------
179
180 Creating an NVMe endpoint device is a two step process. First, an NVMe target
181 subsystem and port must be defined. Second, the NVMe PCI endpoint device must
182 be setup and bound to the subsystem and port created.
183
184 Creating an NVMe Subsystem and Port
185 -----------------------------------
186
187 Details about how to configure an NVMe target subsystem and port are outside the
188 scope of this document. The following only provides a simple example of a port
189 and subsystem with a single namespace backed by a null_blk device.
190
191 First, make sure that configfs is enabled::
192
193 # mount -t configfs none /sys/kernel/config
194
195 Next, create a null_blk device (default settings give a 250 GB device without
196 memory backing). The block device created will be /dev/nullb0 by default::
197
198 # modprobe null_blk
199 # ls /dev/nullb0
200 /dev/nullb0
201
202 The NVMe PCI endpoint function target driver must be loaded::
203
204 # modprobe nvmet_pci_epf
205 # lsmod | grep nvmet
206 nvmet_pci_epf 32768 0
207 nvmet 118784 1 nvmet_pci_epf
208 nvme_core 131072 2 nvmet_pci_epf,nvmet
209
210 Now, create a subsystem and a port that we will use to create a PCI target
211 controller when setting up the NVMe PCI endpoint target device. In this
212 example, the port is created with a maximum of 4 I/O queue pairs::
213
214 # cd /sys/kernel/config/nvmet/subsystems
215 # mkdir nvmepf.0.nqn
216 # echo -n "Linux-pci-epf" > nvmepf.0.nqn/attr_model
217 # echo "0x1b96" > nvmepf.0.nqn/attr_vendor_id
218 # echo "0x1b96" > nvmepf.0.nqn/attr_subsys_vendor_id
219 # echo 1 > nvmepf.0.nqn/attr_allow_any_host
220 # echo 4 > nvmepf.0.nqn/attr_qid_max
221
222 Next, create and enable the subsystem namespace using the null_blk block
223 device::
224
225 # mkdir nvmepf.0.nqn/namespaces/1
226 # echo -n "/dev/nullb0" > nvmepf.0.nqn/namespaces/1/device_path
227 # echo 1 > "nvmepf.0.nqn/namespaces/1/enable"
228
229 Finally, create the target port and link it to the subsystem::
230
231 # cd /sys/kernel/config/nvmet/ports
232 # mkdir 1
233 # echo -n "pci" > 1/addr_trtype
234 # ln -s /sys/kernel/config/nvmet/subsystems/nvmepf.0.nqn \
235 /sys/kernel/config/nvmet/ports/1/subsystems/nvmepf.0.nqn
236
237 Creating an NVMe PCI Endpoint Device
238 ------------------------------------
239
240 With the NVMe target subsystem and port ready for use, the NVMe PCI endpoint
241 device can now be created and enabled. The NVMe PCI endpoint target driver
242 should already be loaded (that is done automatically when the port is created)::
243
244 # ls /sys/kernel/config/pci_ep/functions
245 nvmet_pci_epf
246
247 Next, create function 0::
248
249 # cd /sys/kernel/config/pci_ep/functions/nvmet_pci_epf
250 # mkdir nvmepf.0
251 # ls nvmepf.0/
252 baseclass_code msix_interrupts secondary
253 cache_line_size nvme subclass_code
254 deviceid primary subsys_id
255 interrupt_pin progif_code subsys_vendor_id
256 msi_interrupts revid vendorid
257
258 Configure the function using any device ID (the vendor ID for the device will
259 be automatically set to the same value as the NVMe target subsystem vendor
260 ID)::
261
262 # cd /sys/kernel/config/pci_ep/functions/nvmet_pci_epf
263 # echo 0xBEEF > nvmepf.0/deviceid
264 # echo 32 > nvmepf.0/msix_interrupts
265
266 If the PCI endpoint controller used does not support MSI-X, MSI can be
267 configured instead::
268
269 # echo 32 > nvmepf.0/msi_interrupts
270
271 Next, let's bind our endpoint device with the target subsystem and port that we
272 created::
273
274 # echo 1 > nvmepf.0/nvme/portid
275 # echo "nvmepf.0.nqn" > nvmepf.0/nvme/subsysnqn
276
277 The endpoint function can then be bound to the endpoint controller and the
278 controller started::
279
280 # cd /sys/kernel/config/pci_ep
281 # ln -s functions/nvmet_pci_epf/nvmepf.0 controllers/a40000000.pcie-ep/
282 # echo 1 > controllers/a40000000.pcie-ep/start
283
284 On the endpoint machine, kernel messages will show information as the NVMe
285 target device and endpoint device are created and connected.
286
287 .. code-block:: text
288
289 null_blk: disk nullb0 created
290 null_blk: module loaded
291 nvmet: adding nsid 1 to subsystem nvmepf.0.nqn
292 nvmet_pci_epf nvmet_pci_epf.0: PCI endpoint controller supports MSI-X, 32 vectors
293 nvmet: Created nvm controller 1 for subsystem nvmepf.0.nqn for NQN nqn.2014-08.org.nvmexpress:uuid:2ab90791-2246-4fbb-961d-4c3d5a5a0176.
294 nvmet_pci_epf nvmet_pci_epf.0: New PCI ctrl "nvmepf.0.nqn", 4 I/O queues, mdts 524288 B
295
296 PCI Root-Complex Host
297 ---------------------
298
299 Booting the PCI host will result in the initialization of the PCIe link (this
300 may be signaled by the PCI endpoint driver with a kernel message). A kernel
301 message on the endpoint will also signal when the host NVMe driver enables the
302 device controller::
303
304 nvmet_pci_epf nvmet_pci_epf.0: Enabling controller
305
306 On the host side, the NVMe PCI endpoint function target device is
307 discoverable as a PCI device, with the vendor ID and device ID as configured::
308
309 # lspci -n
310 0000:01:00.0 0108: 1b96:beef
311
312 An this device will be recognized as an NVMe device with a single namespace::
313
314 # lsblk
315 NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINTS
316 nvme0n1 259:0 0 250G 0 disk
317
318 The NVMe endpoint block device can then be used as any other regular NVMe
319 namespace block device. The *nvme* command line utility can be used to get more
320 detailed information about the endpoint device::
321
322 # nvme id-ctrl /dev/nvme0
323 NVME Identify Controller:
324 vid : 0x1b96
325 ssvid : 0x1b96
326 sn : 94993c85650ef7bcd625
327 mn : Linux-pci-epf
328 fr : 6.13.0-r
329 rab : 6
330 ieee : 000000
331 cmic : 0xb
332 mdts : 7
333 cntlid : 0x1
334 ver : 0x20100
335 ...
336
337
338 Endpoint Bindings
339 =================
340
341 The NVMe PCI endpoint target driver uses the PCI endpoint configfs device
342 attributes as follows.
343
344 ================ ===========================================================
345 vendorid Ignored (the vendor id of the NVMe target subsystem is used)
346 deviceid Anything is OK (e.g. PCI_ANY_ID)
347 revid Do not care
348 progif_code Must be 0x02 (NVM Express)
349 baseclass_code Must be 0x01 (PCI_BASE_CLASS_STORAGE)
350 subclass_code Must be 0x08 (Non-Volatile Memory controller)
351 cache_line_size Do not care
352 subsys_vendor_id Ignored (the subsystem vendor id of the NVMe target subsystem
353 is used)
354 subsys_id Anything is OK (e.g. PCI_ANY_ID)
355 msi_interrupts At least equal to the number of queue pairs desired
356 msix_interrupts At least equal to the number of queue pairs desired
357 interrupt_pin Interrupt PIN to use if MSI and MSI-X are not supported
358 ================ ===========================================================
359
360 The NVMe PCI endpoint target function also has some specific configurable
361 fields defined in the *nvme* subdirectory of the function directory. These
362 fields are as follows.
363
364 ================ ===========================================================
365 mdts_kb Maximum data transfer size in KiB (default: 512)
366 portid The ID of the target port to use
367 subsysnqn The NQN of the target subsystem to use
368 ================ ===========================================================