| 1 |
.. SPDX-License-Identifier: GPL-2.0 |
| 2 |
|
| 3 |
PSE Power Interface (PSE PI) Documentation |
| 4 |
========================================== |
| 5 |
|
| 6 |
The Power Sourcing Equipment Power Interface (PSE PI) plays a pivotal role in |
| 7 |
the architecture of Power over Ethernet (PoE) systems. It is essentially a |
| 8 |
blueprint that outlines how one or multiple power sources are connected to the |
| 9 |
eight-pin modular jack, commonly known as the Ethernet RJ45 port. This |
| 10 |
connection scheme is crucial for enabling the delivery of power alongside data |
| 11 |
over Ethernet cables. |
| 12 |
|
| 13 |
Documentation and Standards |
| 14 |
--------------------------- |
| 15 |
|
| 16 |
The IEEE 802.3 standard provides detailed documentation on the PSE PI. |
| 17 |
Specifically: |
| 18 |
|
| 19 |
- Section "33.2.3 PI pin assignments" covers the pin assignments for PoE |
| 20 |
systems that utilize two pairs for power delivery. |
| 21 |
- Section "145.2.4 PSE PI" addresses the configuration for PoE systems that |
| 22 |
deliver power over all four pairs of an Ethernet cable. |
| 23 |
|
| 24 |
PSE PI and Single Pair Ethernet |
| 25 |
------------------------------- |
| 26 |
|
| 27 |
Single Pair Ethernet (SPE) represents a different approach to Ethernet |
| 28 |
connectivity, utilizing just one pair of conductors for both data and power |
| 29 |
transmission. Unlike the configurations detailed in the PSE PI for standard |
| 30 |
Ethernet, which can involve multiple power sourcing arrangements across four or |
| 31 |
two pairs of wires, SPE operates on a simpler model due to its single-pair |
| 32 |
design. As a result, the complexities of choosing between alternative pin |
| 33 |
assignments for power delivery, as described in the PSE PI for multi-pair |
| 34 |
Ethernet, are not applicable to SPE. |
| 35 |
|
| 36 |
Understanding PSE PI |
| 37 |
-------------------- |
| 38 |
|
| 39 |
The Power Sourcing Equipment Power Interface (PSE PI) is a framework defining |
| 40 |
how Power Sourcing Equipment (PSE) delivers power to Powered Devices (PDs) over |
| 41 |
Ethernet cables. It details two main configurations for power delivery, known |
| 42 |
as Alternative A and Alternative B, which are distinguished not only by their |
| 43 |
method of power transmission but also by the implications for polarity and data |
| 44 |
transmission direction. |
| 45 |
|
| 46 |
Alternative A and B Overview |
| 47 |
---------------------------- |
| 48 |
|
| 49 |
- **Alternative A:** Utilizes RJ45 conductors 1, 2, 3 and 6. In either case of |
| 50 |
networks 10/100BaseT or 1G/2G/5G/10GBaseT, the pairs used are carrying data. |
| 51 |
The power delivery's polarity in this alternative can vary based on the MDI |
| 52 |
(Medium Dependent Interface) or MDI-X (Medium Dependent Interface Crossover) |
| 53 |
configuration. |
| 54 |
|
| 55 |
- **Alternative B:** Utilizes RJ45 conductors 4, 5, 7 and 8. In case of |
| 56 |
10/100BaseT network the pairs used are spare pairs without data and are less |
| 57 |
influenced by data transmission direction. This is not the case for |
| 58 |
1G/2G/5G/10GBaseT network. Alternative B includes two configurations with |
| 59 |
different polarities, known as variant X and variant S, to accommodate |
| 60 |
different network requirements and device specifications. |
| 61 |
|
| 62 |
Table 145-3 PSE Pinout Alternatives |
| 63 |
----------------------------------- |
| 64 |
|
| 65 |
The following table outlines the pin configurations for both Alternative A and |
| 66 |
Alternative B. |
| 67 |
|
| 68 |
+------------+-------------------+-----------------+-----------------+-----------------+ |
| 69 |
| Conductor | Alternative A | Alternative A | Alternative B | Alternative B | |
| 70 |
| | (MDI-X) | (MDI) | (X) | (S) | |
| 71 |
+============+===================+=================+=================+=================+ |
| 72 |
| 1 | Negative V | Positive V | - | - | |
| 73 |
+------------+-------------------+-----------------+-----------------+-----------------+ |
| 74 |
| 2 | Negative V | Positive V | - | - | |
| 75 |
+------------+-------------------+-----------------+-----------------+-----------------+ |
| 76 |
| 3 | Positive V | Negative V | - | - | |
| 77 |
+------------+-------------------+-----------------+-----------------+-----------------+ |
| 78 |
| 4 | - | - | Negative V | Positive V | |
| 79 |
+------------+-------------------+-----------------+-----------------+-----------------+ |
| 80 |
| 5 | - | - | Negative V | Positive V | |
| 81 |
+------------+-------------------+-----------------+-----------------+-----------------+ |
| 82 |
| 6 | Positive V | Negative V | - | - | |
| 83 |
+------------+-------------------+-----------------+-----------------+-----------------+ |
| 84 |
| 7 | - | - | Positive V | Negative V | |
| 85 |
+------------+-------------------+-----------------+-----------------+-----------------+ |
| 86 |
| 8 | - | - | Positive V | Negative V | |
| 87 |
+------------+-------------------+-----------------+-----------------+-----------------+ |
| 88 |
|
| 89 |
.. note:: |
| 90 |
- "Positive V" and "Negative V" indicate the voltage polarity for each pin. |
| 91 |
- "-" indicates that the pin is not used for power delivery in that |
| 92 |
specific configuration. |
| 93 |
|
| 94 |
PSE PI compatibilities |
| 95 |
---------------------- |
| 96 |
|
| 97 |
The following table outlines the compatibility between the pinout alternative |
| 98 |
and the 1000/2.5G/5G/10GBaseT in the PSE 2 pairs connection. |
| 99 |
|
| 100 |
+---------+---------------+---------------------+-----------------------+ |
| 101 |
| Variant | Alternative | Power Feeding Type | Compatibility with | |
| 102 |
| | (A/B) | (Direct/Phantom) | 1000/2.5G/5G/10GBaseT | |
| 103 |
+=========+===============+=====================+=======================+ |
| 104 |
| 1 | A | Phantom | Yes | |
| 105 |
+---------+---------------+---------------------+-----------------------+ |
| 106 |
| 2 | B | Phantom | Yes | |
| 107 |
+---------+---------------+---------------------+-----------------------+ |
| 108 |
| 3 | B | Direct | No | |
| 109 |
+---------+---------------+---------------------+-----------------------+ |
| 110 |
|
| 111 |
.. note:: |
| 112 |
- "Direct" indicate a variant where the power is injected directly to pairs |
| 113 |
without using magnetics in case of spare pairs. |
| 114 |
- "Phantom" indicate power path over coils/magnetics as it is done for |
| 115 |
Alternative A variant. |
| 116 |
|
| 117 |
In case of PSE 4 pairs, a PSE supporting only 10/100BaseT (which mean Direct |
| 118 |
Power on pinout Alternative B) is not compatible with a 4 pairs |
| 119 |
1000/2.5G/5G/10GBaseT. |
| 120 |
|
| 121 |
PSE Power Interface (PSE PI) Connection Diagram |
| 122 |
----------------------------------------------- |
| 123 |
|
| 124 |
The diagram below illustrates the connection architecture between the RJ45 |
| 125 |
port, the Ethernet PHY (Physical Layer), and the PSE PI (Power Sourcing |
| 126 |
Equipment Power Interface), demonstrating how power and data are delivered |
| 127 |
simultaneously through an Ethernet cable. The RJ45 port serves as the physical |
| 128 |
interface for these connections, with each of its eight pins connected to both |
| 129 |
the Ethernet PHY for data transmission and the PSE PI for power delivery. |
| 130 |
|
| 131 |
.. code-block:: |
| 132 |
|
| 133 |
+--------------------------+ |
| 134 |
| | |
| 135 |
| RJ45 Port | |
| 136 |
| | |
| 137 |
+--+--+--+--+--+--+--+--+--+ +-------------+ |
| 138 |
1| 2| 3| 4| 5| 6| 7| 8| | | |
| 139 |
| | | | | | | o-------------------+ | |
| 140 |
| | | | | | o--|-------------------+ +<--- PSE 1 |
| 141 |
| | | | | o--|--|-------------------+ | |
| 142 |
| | | | o--|--|--|-------------------+ | |
| 143 |
| | | o--|--|--|--|-------------------+ PSE PI | |
| 144 |
| | o--|--|--|--|--|-------------------+ | |
| 145 |
| o--|--|--|--|--|--|-------------------+ +<--- PSE 2 (optional) |
| 146 |
o--|--|--|--|--|--|--|-------------------+ | |
| 147 |
| | | | | | | | | | |
| 148 |
+--+--+--+--+--+--+--+--+--+ +-------------+ |
| 149 |
| | |
| 150 |
| Ethernet PHY | |
| 151 |
| | |
| 152 |
+--------------------------+ |
| 153 |
|
| 154 |
Simple PSE PI Configuration for Alternative A |
| 155 |
--------------------------------------------- |
| 156 |
|
| 157 |
The diagram below illustrates a straightforward PSE PI (Power Sourcing |
| 158 |
Equipment Power Interface) configuration designed to support the Alternative A |
| 159 |
setup for Power over Ethernet (PoE). This implementation is tailored to provide |
| 160 |
power delivery through the data-carrying pairs of an Ethernet cable, suitable |
| 161 |
for either MDI or MDI-X configurations, albeit supporting one variation at a |
| 162 |
time. |
| 163 |
|
| 164 |
.. code-block:: |
| 165 |
|
| 166 |
+-------------+ |
| 167 |
| PSE PI | |
| 168 |
8 -----+ +-------------+ |
| 169 |
7 -----+ Rail 1 | |
| 170 |
6 -----+------+----------------------+ |
| 171 |
5 -----+ | | |
| 172 |
4 -----+ | Rail 2 | PSE 1 |
| 173 |
3 -----+------/ +------------+ |
| 174 |
2 -----+--+-------------/ | |
| 175 |
1 -----+--/ +-------------+ |
| 176 |
| |
| 177 |
+-------------+ |
| 178 |
|
| 179 |
In this configuration: |
| 180 |
|
| 181 |
- Pins 1 and 2, as well as pins 3 and 6, are utilized for power delivery in |
| 182 |
addition to data transmission. This aligns with the standard wiring for |
| 183 |
10/100BaseT Ethernet networks where these pairs are used for data. |
| 184 |
- Rail 1 and Rail 2 represent the positive and negative voltage rails, with |
| 185 |
Rail 1 connected to pins 1 and 2, and Rail 2 connected to pins 3 and 6. |
| 186 |
More advanced PSE PI configurations may include integrated or external |
| 187 |
switches to change the polarity of the voltage rails, allowing for |
| 188 |
compatibility with both MDI and MDI-X configurations. |
| 189 |
|
| 190 |
More complex PSE PI configurations may include additional components, to support |
| 191 |
Alternative B, or to provide additional features such as power management, or |
| 192 |
additional power delivery capabilities such as 2-pair or 4-pair power delivery. |
| 193 |
|
| 194 |
.. code-block:: |
| 195 |
|
| 196 |
+-------------+ |
| 197 |
| PSE PI | |
| 198 |
| +---+ |
| 199 |
8 -----+--------+ | +-------------+ |
| 200 |
7 -----+--------+ | Rail 1 | |
| 201 |
6 -----+--------+ +-----------------+ |
| 202 |
5 -----+--------+ | | |
| 203 |
4 -----+--------+ | Rail 2 | PSE 1 |
| 204 |
3 -----+--------+ +----------------+ |
| 205 |
2 -----+--------+ | | |
| 206 |
1 -----+--------+ | +-------------+ |
| 207 |
| +---+ |
| 208 |
+-------------+ |
| 209 |
|
| 210 |
Device Tree Configuration: Describing PSE PI Configurations |
| 211 |
----------------------------------------------------------- |
| 212 |
|
| 213 |
The necessity for a separate PSE PI node in the device tree is influenced by |
| 214 |
the intricacy of the Power over Ethernet (PoE) system's setup. Here are |
| 215 |
descriptions of both simple and complex PSE PI configurations to illustrate |
| 216 |
this decision-making process: |
| 217 |
|
| 218 |
**Simple PSE PI Configuration:** |
| 219 |
In a straightforward scenario, the PSE PI setup involves a direct, one-to-one |
| 220 |
connection between a single PSE controller and an Ethernet port. This setup |
| 221 |
typically supports basic PoE functionality without the need for dynamic |
| 222 |
configuration or management of multiple power delivery modes. For such simple |
| 223 |
configurations, detailing the PSE PI within the existing PSE controller's node |
| 224 |
may suffice, as the system does not encompass additional complexity that |
| 225 |
warrants a separate node. The primary focus here is on the clear and direct |
| 226 |
association of power delivery to a specific Ethernet port. |
| 227 |
|
| 228 |
**Complex PSE PI Configuration:** |
| 229 |
Contrastingly, a complex PSE PI setup may encompass multiple PSE controllers or |
| 230 |
auxiliary circuits that collectively manage power delivery to one Ethernet |
| 231 |
port. Such configurations might support a range of PoE standards and require |
| 232 |
the capability to dynamically configure power delivery based on the operational |
| 233 |
mode (e.g., PoE2 versus PoE4) or specific requirements of connected devices. In |
| 234 |
these instances, a dedicated PSE PI node becomes essential for accurately |
| 235 |
documenting the system architecture. This node would serve to detail the |
| 236 |
interactions between different PSE controllers, the support for various PoE |
| 237 |
modes, and any additional logic required to coordinate power delivery across |
| 238 |
the network infrastructure. |
| 239 |
|
| 240 |
**Guidance:** |
| 241 |
|
| 242 |
For simple PSE setups, including PSE PI information in the PSE controller node |
| 243 |
might suffice due to the straightforward nature of these systems. However, |
| 244 |
complex configurations, involving multiple components or advanced PoE features, |
| 245 |
benefit from a dedicated PSE PI node. This method adheres to IEEE 802.3 |
| 246 |
specifications, improving documentation clarity and ensuring accurate |
| 247 |
representation of the PoE system's complexity. |
| 248 |
|
| 249 |
PSE PI Node: Essential Information |
| 250 |
---------------------------------- |
| 251 |
|
| 252 |
The PSE PI (Power Sourcing Equipment Power Interface) node in a device tree can |
| 253 |
include several key pieces of information critical for defining the power |
| 254 |
delivery capabilities and configurations of a PoE (Power over Ethernet) system. |
| 255 |
Below is a list of such information, along with explanations for their |
| 256 |
necessity and reasons why they might not be found within a PSE controller node: |
| 257 |
|
| 258 |
1. **Powered Pairs Configuration** |
| 259 |
|
| 260 |
- *Description:* Identifies the pairs used for power delivery in the |
| 261 |
Ethernet cable. |
| 262 |
- *Necessity:* Essential to ensure the correct pairs are powered according |
| 263 |
to the board's design. |
| 264 |
- *PSE Controller Node:* Typically lacks details on physical pair usage, |
| 265 |
focusing on power regulation. |
| 266 |
|
| 267 |
2. **Polarity of Powered Pairs** |
| 268 |
|
| 269 |
- *Description:* Specifies the polarity (positive or negative) for each |
| 270 |
powered pair. |
| 271 |
- *Necessity:* Critical for safe and effective power transmission to PDs. |
| 272 |
- *PSE Controller Node:* Polarity management may exceed the standard |
| 273 |
functionalities of PSE controllers. |
| 274 |
|
| 275 |
3. **PSE Cells Association** |
| 276 |
|
| 277 |
- *Description:* Details the association of PSE cells with Ethernet ports or |
| 278 |
pairs in multi-cell configurations. |
| 279 |
- *Necessity:* Allows for optimized power resource allocation in complex |
| 280 |
systems. |
| 281 |
- *PSE Controller Node:* Controllers may not manage cell associations |
| 282 |
directly, focusing instead on power flow regulation. |
| 283 |
|
| 284 |
4. **Support for PoE Standards** |
| 285 |
|
| 286 |
- *Description:* Lists the PoE standards and configurations supported by the |
| 287 |
system. |
| 288 |
- *Necessity:* Ensures system compatibility with various PDs and adherence |
| 289 |
to industry standards. |
| 290 |
- *PSE Controller Node:* Specific capabilities may depend on the overall PSE |
| 291 |
PI design rather than the controller alone. Multiple PSE cells per PI |
| 292 |
do not necessarily imply support for multiple PoE standards. |
| 293 |
|
| 294 |
5. **Protection Mechanisms** |
| 295 |
|
| 296 |
- *Description:* Outlines additional protection mechanisms, such as |
| 297 |
overcurrent protection and thermal management. |
| 298 |
- *Necessity:* Provides extra safety and stability, complementing PSE |
| 299 |
controller protections. |
| 300 |
- *PSE Controller Node:* Some protections may be implemented via |
| 301 |
board-specific hardware or algorithms external to the controller. |