Diagnostic Concept for Investigating Twisted Pair Ethernet Variants at OSI Layer 1 |
| 4 |
================================================================================== |
| 5 |
|
| 6 |
Introduction |
| 7 |
------------ |
| 8 |
|
| 9 |
This documentation is designed for two primary audiences: |
| 10 |
|
| 11 |
1. **Users and System Administrators**: For those dealing with real-world |
| 12 |
Ethernet issues, this guide provides a practical, step-by-step |
| 13 |
troubleshooting flow to help identify and resolve common problems in Twisted |
| 14 |
Pair Ethernet at OSI Layer 1. If you're facing unstable links, speed drops, |
| 15 |
or mysterious network issues, jump right into the step-by-step guide and |
| 16 |
follow it through to find your solution. |
| 17 |
|
| 18 |
2. **Kernel Developers**: For developers working with network drivers and PHY |
| 19 |
support, this documentation outlines the diagnostic process and highlights |
| 20 |
areas where the Linux kernel’s diagnostic interfaces could be extended or |
| 21 |
improved. By understanding the diagnostic flow, developers can better |
| 22 |
prioritize future enhancements. |
| 23 |
|
| 24 |
Step-by-Step Diagnostic Guide from Linux (General Ethernet) |
| 25 |
----------------------------------------------------------- |
| 26 |
|
| 27 |
This diagnostic guide covers common Ethernet troubleshooting scenarios, |
| 28 |
focusing on **link stability and detection** across different Ethernet |
| 29 |
environments, including **Single-Pair Ethernet (SPE)** and **Multi-Pair |
| 30 |
Ethernet (MPE)**, as well as power delivery technologies like **PoDL** (Power |
| 31 |
over Data Line) and **PoE** (Clause 33 PSE). |
| 32 |
|
| 33 |
The guide is designed to help users diagnose physical layer (Layer 1) issues on |
| 34 |
systems running **Linux kernel version 6.11 or newer**, utilizing **ethtool |
| 35 |
version 6.10 or later** and **iproute2 version 6.4.0 or later**. |
| 36 |
|
| 37 |
In this guide, we assume that users may have **limited or no access to the link |
| 38 |
partner** and will focus on diagnosing issues locally. |
| 39 |
|
| 40 |
Diagnostic Scenarios |
| 41 |
~~~~~~~~~~~~~~~~~~~~ |
| 42 |
|
| 43 |
- **Link is up and stable, but no data transfer**: If the link is stable but |
| 44 |
there are issues with data transmission, refer to the **OSI Layer 2 |
| 45 |
Troubleshooting Guide**. |
| 46 |
|
| 47 |
- **Link is unstable**: Link resets, speed drops, or other fluctuations |
| 48 |
indicate potential issues at the hardware or physical layer. |
| 49 |
|
| 50 |
- **No link detected**: The interface is up, but no link is established. |
| 51 |
|
| 52 |
Verify Interface Status |
| 53 |
~~~~~~~~~~~~~~~~~~~~~~~ |
| 54 |
|
| 55 |
Begin by verifying the status of the Ethernet interface to check if it is |
| 56 |
administratively up. Unlike `ethtool`, which provides information on the link |
| 57 |
and PHY status, it does not show the **administrative state** of the interface. |
| 58 |
To check this, you should use the `ip` command, which describes the interface |
| 59 |
state within the angle brackets `"<>"` in its output. |
| 60 |
|
| 61 |
For example, in the output `<NO-CARRIER,BROADCAST,MULTICAST,UP>`, the important |
| 62 |
keywords are: |
| 63 |
|
| 64 |
- **UP**: The interface is in the administrative "UP" state. |
| 65 |
- **NO-CARRIER**: The interface is administratively up, but no physical link is |
| 66 |
detected. |
| 67 |
|
| 68 |
If the output shows `<BROADCAST,MULTICAST>`, this indicates the interface is in |
| 69 |
the administrative "DOWN" state. |
| 70 |
|
| 71 |
- **Command:** `ip link show dev <interface>` |
| 72 |
|
| 73 |
- **Expected Output:** |
| 74 |
|
| 75 |
.. code-block:: bash |
| 76 |
|
| 77 |
4: eth0: <NO-CARRIER,BROADCAST,MULTICAST,UP> mtu 1500 ... |
| 78 |
link/ether 88:14:2b:00:96:f2 brd ff:ff:ff:ff:ff:ff |
| 79 |
|
| 80 |
- **Interpreting the Output:** |
| 81 |
|
| 82 |
- **Administrative UP State**: |
| 83 |
|
| 84 |
- If the output contains **"UP"**, the interface is administratively up, |
| 85 |
and the system is trying to establish a physical link. |
| 86 |
|
| 87 |
- If you also see **"NO-CARRIER"**, it means the physical link has not been |
| 88 |
detected, indicating potential Layer 1 issues like a cable fault, |
| 89 |
misconfiguration, or no connection at the link partner. In this case, |
| 90 |
proceed to the **Inspect Link Status and PHY Configuration** section. |
| 91 |
|
| 92 |
- **Administrative DOWN State**: |
| 93 |
|
| 94 |
- If the output lacks **"UP"** and shows only states like |
| 95 |
**"<BROADCAST,MULTICAST>"**, it means the interface is administratively |
| 96 |
down. In this case, bring the interface up using the following command: |
| 97 |
|
| 98 |
.. code-block:: bash |
| 99 |
|
| 100 |
ip link set dev <interface> up |
| 101 |
|
| 102 |
- **Next Steps**: |
| 103 |
|
| 104 |
- If the interface is **administratively up** but shows **NO-CARRIER**, |
| 105 |
proceed to the **Inspect Link Status and PHY Configuration** section to |
| 106 |
troubleshoot potential physical layer issues. |
| 107 |
|
| 108 |
- If the interface was **administratively down** and you have brought it up, |
| 109 |
ensure to **repeat this verification step** to confirm the new state of the |
| 110 |
interface before proceeding |
| 111 |
|
| 112 |
- **If the interface is up and the link is detected**: |
| 113 |
|
| 114 |
- If the output shows **"UP"** and there is **no `NO-CARRIER`**, the |
| 115 |
interface is administratively up, and the physical link has been |
| 116 |
successfully established. If everything is working as expected, the Layer |
| 117 |
1 diagnostics are complete, and no further action is needed. |
| 118 |
|
| 119 |
- If the interface is up and the link is detected but **no data is being |
| 120 |
transferred**, the issue is likely beyond Layer 1, and you should proceed |
| 121 |
with diagnosing the higher layers of the OSI model. This may involve |
| 122 |
checking Layer 2 configurations (such as VLANs or MAC address issues), |
| 123 |
Layer 3 settings (like IP addresses, routing, or ARP), or Layer 4 and |
| 124 |
above (firewalls, services, etc.). |
| 125 |
|
| 126 |
- If the **link is unstable** or **frequently resetting or dropping**, this |
| 127 |
may indicate a physical layer issue such as a faulty cable, interference, |
| 128 |
or power delivery problems. In this case, proceed with the next step in |
| 129 |
this guide. |
| 130 |
|
| 131 |
Inspect Link Status and PHY Configuration |
| 132 |
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| 133 |
|
| 134 |
Use `ethtool -I` to check the link status, PHY configuration, supported link |
| 135 |
modes, and additional statistics such as the **Link Down Events** counter. This |
| 136 |
step is essential for diagnosing Layer 1 problems such as speed mismatches, |
| 137 |
duplex issues, and link instability. |
| 138 |
|
| 139 |
For both **Single-Pair Ethernet (SPE)** and **Multi-Pair Ethernet (MPE)** |
| 140 |
devices, you will use this step to gather key details about the link. **SPE** |
| 141 |
links generally support a single speed and mode without autonegotiation (with |
| 142 |
the exception of **10BaseT1L**), while **MPE** devices typically support |
| 143 |
multiple link modes and autonegotiation. |
| 144 |
|
| 145 |
- **Command:** `ethtool -I <interface>` |
| 146 |
|
| 147 |
- **Example Output for SPE Interface (Non-autonegotiation)**: |
| 148 |
|
| 149 |
.. code-block:: bash |
| 150 |
|
| 151 |
Settings for spe4: |
| 152 |
Supported ports: [ TP ] |
| 153 |
Supported link modes: 100baseT1/Full |
| 154 |
Supported pause frame use: No |
| 155 |
Supports auto-negotiation: No |
| 156 |
Supported FEC modes: Not reported |
| 157 |
Advertised link modes: Not applicable |
| 158 |
Advertised pause frame use: No |
| 159 |
Advertised auto-negotiation: No |
| 160 |
Advertised FEC modes: Not reported |
| 161 |
Speed: 100Mb/s |
| 162 |
Duplex: Full |
| 163 |
Auto-negotiation: off |
| 164 |
master-slave cfg: forced slave |
| 165 |
master-slave status: slave |
| 166 |
Port: Twisted Pair |
| 167 |
PHYAD: 6 |
| 168 |
Transceiver: external |
| 169 |
MDI-X: Unknown |
| 170 |
Supports Wake-on: d |
| 171 |
Wake-on: d |
| 172 |
Link detected: yes |
| 173 |
SQI: 7/7 |
| 174 |
Link Down Events: 2 |
| 175 |
|
| 176 |
- **Example Output for MPE Interface (Autonegotiation)**: |
| 177 |
|
| 178 |
.. code-block:: bash |
| 179 |
|
| 180 |
Settings for eth1: |
| 181 |
Supported ports: [ TP MII ] |
| 182 |
Supported link modes: 10baseT/Half 10baseT/Full |
| 183 |
100baseT/Half 100baseT/Full |
| 184 |
Supported pause frame use: Symmetric Receive-only |
| 185 |
Supports auto-negotiation: Yes |
| 186 |
Supported FEC modes: Not reported |
| 187 |
Advertised link modes: 10baseT/Half 10baseT/Full |
| 188 |
100baseT/Half 100baseT/Full |
| 189 |
Advertised pause frame use: Symmetric Receive-only |
| 190 |
Advertised auto-negotiation: Yes |
| 191 |
Advertised FEC modes: Not reported |
| 192 |
Link partner advertised link modes: 10baseT/Half 10baseT/Full |
| 193 |
100baseT/Half 100baseT/Full |
| 194 |
Link partner advertised pause frame use: Symmetric Receive-only |
| 195 |
Link partner advertised auto-negotiation: Yes |
| 196 |
Link partner advertised FEC modes: Not reported |
| 197 |
Speed: 100Mb/s |
| 198 |
Duplex: Full |
| 199 |
Auto-negotiation: on |
| 200 |
Port: Twisted Pair |
| 201 |
PHYAD: 10 |
| 202 |
Transceiver: internal |
| 203 |
MDI-X: Unknown |
| 204 |
Supports Wake-on: pg |
| 205 |
Wake-on: p |
| 206 |
Link detected: yes |
| 207 |
Link Down Events: 1 |
| 208 |
|
| 209 |
- **Next Steps**: |
| 210 |
|
| 211 |
- Record the output provided by `ethtool`, particularly noting the |
| 212 |
**master-slave status**, **speed**, **duplex**, and other relevant fields. |
| 213 |
This information will be useful for further analysis or troubleshooting. |
| 214 |
Once the **ethtool** output has been collected and stored, move on to the |
| 215 |
next diagnostic step. |
| 216 |
|
| 217 |
Check Power Delivery (PoDL or PoE) |
| 218 |
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| 219 |
|
| 220 |
If it is known that **PoDL** or **PoE** is **not implemented** on the system, |
| 221 |
or the **PSE** (Power Sourcing Equipment) is managed by proprietary user-space |
| 222 |
software or external tools, you can skip this step. In such cases, verify power |
| 223 |
delivery through alternative methods, such as checking hardware indicators |
| 224 |
(LEDs), using multimeters, or consulting vendor-specific software for |
| 225 |
monitoring power status. |
| 226 |
|
| 227 |
If **PoDL** or **PoE** is implemented and managed directly by Linux, follow |
| 228 |
these steps to ensure power is being delivered correctly: |
| 229 |
|
| 230 |
- **Command:** `ethtool --show-pse <interface>` |
| 231 |
|
| 232 |
- **Expected Output Examples**: |
| 233 |
|
| 234 |
1. **PSE Not Supported**: |
| 235 |
|
| 236 |
If no PSE is attached or the interface does not support PSE, the following |
| 237 |
output is expected: |
| 238 |
|
| 239 |
.. code-block:: bash |
| 240 |
|
| 241 |
netlink error: No PSE is attached |
| 242 |
netlink error: Operation not supported |
| 243 |
|
| 244 |
2. **PoDL (Single-Pair Ethernet)**: |
| 245 |
|
| 246 |
When PoDL is implemented, you might see the following attributes: |
| 247 |
|
| 248 |
.. code-block:: bash |
| 249 |
|
| 250 |
PSE attributes for eth1: |
| 251 |
PoDL PSE Admin State: enabled |
| 252 |
PoDL PSE Power Detection Status: delivering power |
| 253 |
|
| 254 |
3. **PoE (Clause 33 PSE)**: |
| 255 |
|
| 256 |
For standard PoE, the output may look like this: |
| 257 |
|
| 258 |
.. code-block:: bash |
| 259 |
|
| 260 |
PSE attributes for eth1: |
| 261 |
Clause 33 PSE Admin State: enabled |
| 262 |
Clause 33 PSE Power Detection Status: delivering power |
| 263 |
Clause 33 PSE Available Power Limit: 18000 |
| 264 |
|
| 265 |
- **Adjust Power Limit (if needed)**: |
| 266 |
|
| 267 |
- Sometimes, the available power limit may not be sufficient for the link |
| 268 |
partner. You can increase the power limit as needed. |
| 269 |
|
| 270 |
- **Command:** `ethtool --set-pse <interface> c33-pse-avail-pw-limit <limit>` |
| 271 |
|
| 272 |
Example: |
| 273 |
|
| 274 |
.. code-block:: bash |
| 275 |
|
| 276 |
ethtool --set-pse eth1 c33-pse-avail-pw-limit 18000 |
| 277 |
ethtool --show-pse eth1 |
| 278 |
|
| 279 |
**Expected Output** after adjusting the power limit: |
| 280 |
|
| 281 |
.. code-block:: bash |
| 282 |
|
| 283 |
Clause 33 PSE Available Power Limit: 18000 |
| 284 |
|
| 285 |
|
| 286 |
- **Next Steps**: |
| 287 |
|
| 288 |
- **PoE or PoDL Not Used**: If **PoE** or **PoDL** is not implemented or used |
| 289 |
on the system, proceed to the next diagnostic step, as power delivery is |
| 290 |
not relevant for this setup. |
| 291 |
|
| 292 |
- **PoE or PoDL Controlled Externally**: If **PoE** or **PoDL** is used but |
| 293 |
is not managed by the Linux kernel's **PSE-PD** framework (i.e., it is |
| 294 |
controlled by proprietary user-space software or external tools), this part |
| 295 |
is out of scope for this documentation. Please consult vendor-specific |
| 296 |
documentation or external tools for monitoring and managing power delivery. |
| 297 |
|
| 298 |
- **PSE Admin State Disabled**: |
| 299 |
|
| 300 |
- If the `PSE Admin State:` is **disabled**, enable it by running one of |
| 301 |
the following commands: |
| 302 |
|
| 303 |
.. code-block:: bash |
| 304 |
|
| 305 |
ethtool --set-pse <devname> podl-pse-admin-control enable |
| 306 |
|
| 307 |
or, for Clause 33 PSE (PoE): |
| 308 |
|
| 309 |
ethtool --set-pse <devname> c33-pse-admin-control enable |
| 310 |
|
| 311 |
- After enabling the PSE Admin State, return to the start of the **Check |
| 312 |
Power Delivery (PoDL or PoE)** step to recheck the power delivery status. |
| 313 |
|
| 314 |
- **Power Not Delivered**: If the `Power Detection Status` shows something |
| 315 |
other than "delivering power" (e.g., `over current`), troubleshoot the |
| 316 |
**PSE**. Check for potential issues such as a short circuit in the cable, |
| 317 |
insufficient power delivery, or a fault in the PSE itself. |
| 318 |
|
| 319 |
- **Power Delivered but No Link**: If power is being delivered but no link is |
| 320 |
established, proceed with further diagnostics by performing **Cable |
| 321 |
Diagnostics** or reviewing the **Inspect Link Status and PHY |
| 322 |
Configuration** steps to identify any underlying issues with the physical |
| 323 |
link or settings. |
| 324 |
|
| 325 |
Cable Diagnostics |
| 326 |
~~~~~~~~~~~~~~~~~ |
| 327 |
|
| 328 |
Use `ethtool` to test for physical layer issues such as cable faults. The test |
| 329 |
results can vary depending on the cable's condition, the technology in use, and |
| 330 |
the state of the link partner. The results from the cable test will help in |
| 331 |
diagnosing issues like open circuits, shorts, impedance mismatches, and |
| 332 |
noise-related problems. |
| 333 |
|
| 334 |
- **Command:** `ethtool --cable-test <interface>` |
| 335 |
|
| 336 |
The following are the typical outputs for **Single-Pair Ethernet (SPE)** and |
| 337 |
**Multi-Pair Ethernet (MPE)**: |
| 338 |
|
| 339 |
- **For Single-Pair Ethernet (SPE)**: |
| 340 |
- **Expected Output (SPE)**: |
| 341 |
|
| 342 |
.. code-block:: bash |
| 343 |
|
| 344 |
Cable test completed for device eth1. |
| 345 |
Pair A, fault length: 25.00m |
| 346 |
Pair A code Open Circuit |
| 347 |
|
| 348 |
This indicates an open circuit or cable fault at the reported distance, but |
| 349 |
results can be influenced by the link partner's state. Refer to the |
| 350 |
**"Troubleshooting Based on Cable Test Results"** section for further |
| 351 |
interpretation of these results. |
| 352 |
|
| 353 |
- **For Multi-Pair Ethernet (MPE)**: |
| 354 |
- **Expected Output (MPE)**: |
| 355 |
|
| 356 |
.. code-block:: bash |
| 357 |
|
| 358 |
Cable test completed for device eth0. |
| 359 |
Pair A code OK |
| 360 |
Pair B code OK |
| 361 |
Pair C code Open Circuit |
| 362 |
|
| 363 |
Here, Pair C is reported as having an open circuit, while Pairs A and B are |
| 364 |
functioning correctly. However, if autonegotiation is in use on Pairs A and |
| 365 |
B, the cable test may be disrupted. Refer to the **"Troubleshooting Based on |
| 366 |
Cable Test Results"** section for a detailed explanation of these issues and |
| 367 |
how to resolve them. |
| 368 |
|
| 369 |
For detailed descriptions of the different possible cable test results, please |
| 370 |
refer to the **"Troubleshooting Based on Cable Test Results"** section. |
| 371 |
|
| 372 |
Troubleshooting Based on Cable Test Results |
| 373 |
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ |
| 374 |
|
| 375 |
After running the cable test, the results can help identify specific issues in |
| 376 |
the physical connection. However, it is important to note that **cable testing |
| 377 |
results heavily depend on the capabilities and characteristics of both the |
| 378 |
local hardware and the link partner**. The accuracy and reliability of the |
| 379 |
results can vary significantly between different hardware implementations. |
| 380 |
|
| 381 |
In some cases, this can introduce **blind spots** in the current cable testing |
| 382 |
implementation, where certain results may not accurately reflect the actual |
| 383 |
physical state of the cable. For example: |
| 384 |
|
| 385 |
- An **Open Circuit** result might not only indicate a damaged or disconnected |
| 386 |
cable but also occur if the cable is properly attached to a powered-down link |
| 387 |
partner. |
| 388 |
|
| 389 |
- Some PHYs may report a **Short within Pair** if the link partner is in |
| 390 |
**forced slave mode**, even though there is no actual short in the cable. |
| 391 |
|
| 392 |
To help users interpret the results more effectively, it could be beneficial to |
| 393 |
extend the **kernel UAPI** (User API) to provide additional context or |
| 394 |
**possible variants** of issues based on the hardware’s characteristics. Since |
| 395 |
these quirks are often hardware-specific, the **kernel driver** would be an |
| 396 |
ideal source of such information. By providing flags or hints related to |
| 397 |
potential false positives for each test result, users would have a better |
| 398 |
understanding of what to verify and where to investigate further. |
| 399 |
|
| 400 |
Until such improvements are made, users should be aware of these limitations |
| 401 |
and manually verify cable issues as needed. Physical inspections may help |
| 402 |
resolve uncertainties related to false positive results. |
| 403 |
|
| 404 |
The results can be one of the following: |
| 405 |
|
| 406 |
- **OK**: |
| 407 |
|
| 408 |
- The cable is functioning correctly, and no issues were detected. |
| 409 |
|
| 410 |
- **Next Steps**: If you are still experiencing issues, it might be related |
| 411 |
to higher-layer problems, such as duplex mismatches or speed negotiation, |
| 412 |
which are not physical-layer issues. |
| 413 |
|
| 414 |
- **Special Case for `BaseT1` (1000/100/10BaseT1)**: In `BaseT1` systems, an |
| 415 |
"OK" result typically also means that the link is up and likely in **slave |
| 416 |
mode**, since cable tests usually only pass in this mode. For some |
| 417 |
**10BaseT1L** PHYs, an "OK" result may occur even if the cable is too long |
| 418 |
for the PHY's configured range (for example, when the range is configured |
| 419 |
for short-distance mode). |
| 420 |
|
| 421 |
- **Open Circuit**: |
| 422 |
|
| 423 |
- An **Open Circuit** result typically indicates that the cable is damaged or |
| 424 |
disconnected at the reported fault length. Consider these possibilities: |
| 425 |
|
| 426 |
- If the link partner is in **admin down** state or powered off, you might |
| 427 |
still get an "Open Circuit" result even if the cable is functional. |
| 428 |
|
| 429 |
- **Next Steps**: Inspect the cable at the fault length for visible damage |
| 430 |
or loose connections. Verify the link partner is powered on and in the |
| 431 |
correct mode. |
| 432 |
|
| 433 |
- **Short within Pair**: |
| 434 |
|
| 435 |
- A **Short within Pair** indicates an unintended connection within the same |
| 436 |
pair of wires, typically caused by physical damage to the cable. |
| 437 |
|
| 438 |
- **Next Steps**: Replace or repair the cable and check for any physical |
| 439 |
damage or improperly crimped connectors. |
| 440 |
|
| 441 |
- **Short to Another Pair**: |
| 442 |
|
| 443 |
- A **Short to Another Pair** means the wires from different pairs are |
| 444 |
shorted, which could occur due to physical damage or incorrect wiring. |
| 445 |
|
| 446 |
- **Next Steps**: Replace or repair the damaged cable. Inspect the cable for |
| 447 |
incorrect terminations or pinched wiring. |
| 448 |
|
| 449 |
- **Impedance Mismatch**: |
| 450 |
|
| 451 |
- **Impedance Mismatch** indicates a reflection caused by an impedance |
| 452 |
discontinuity in the cable. This can happen when a part of the cable has |
| 453 |
abnormal impedance (e.g., when different cable types are spliced together |
| 454 |
or when there is a defect in the cable). |
| 455 |
|
| 456 |
- **Next Steps**: Check the cable quality and ensure consistent impedance |
| 457 |
throughout its length. Replace any sections of the cable that do not meet |
| 458 |
specifications. |
| 459 |
|
| 460 |
- **Noise**: |
| 461 |
|
| 462 |
- **Noise** means that the Time Domain Reflectometry (TDR) test could not |
| 463 |
complete due to excessive noise on the cable, which can be caused by |
| 464 |
interference from electromagnetic sources. |
| 465 |
|
| 466 |
- **Next Steps**: Identify and eliminate sources of electromagnetic |
| 467 |
interference (EMI) near the cable. Consider using shielded cables or |
| 468 |
rerouting the cable away from noise sources. |
| 469 |
|
| 470 |
- **Resolution Not Possible**: |
| 471 |
|
| 472 |
- **Resolution Not Possible** means that the TDR test could not detect the |
| 473 |
issue due to the resolution limitations of the test or because the fault is |
| 474 |
beyond the distance that the test can measure. |
| 475 |
|
| 476 |
- **Next Steps**: Inspect the cable manually if possible, or use alternative |
| 477 |
diagnostic tools that can handle greater distances or higher resolution. |
| 478 |
|
| 479 |
- **Unknown**: |
| 480 |
|
| 481 |
- An **Unknown** result may occur when the test cannot classify the fault or |
| 482 |
when a specific issue is outside the scope of the tool's detection |
| 483 |
capabilities. |
| 484 |
|
| 485 |
- **Next Steps**: Re-run the test, verify the link partner's state, and inspect |
| 486 |
the cable manually if necessary. |
| 487 |
|
| 488 |
Verify Link Partner PHY Configuration |
| 489 |
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| 490 |
|
| 491 |
If the cable test passes but the link is still not functioning correctly, it’s |
| 492 |
essential to verify the configuration of the link partner’s PHY. Mismatches in |
| 493 |
speed, duplex settings, or master-slave roles can cause connection issues. |
| 494 |
|
| 495 |
Autonegotiation Mismatch |
| 496 |
^^^^^^^^^^^^^^^^^^^^^^^^ |
| 497 |
|
| 498 |
- If both link partners support autonegotiation, ensure that autonegotiation is |
| 499 |
enabled on both sides and that all supported link modes are advertised. A |
| 500 |
mismatch can lead to connectivity problems or sub optimal performance. |
| 501 |
|
| 502 |
- **Quick Fix:** Reset autonegotiation to the default settings, which will |
| 503 |
advertise all default link modes: |
| 504 |
|
| 505 |
.. code-block:: bash |
| 506 |
|
| 507 |
ethtool -s <interface> autoneg on |
| 508 |
|
| 509 |
- **Command to check configuration:** `ethtool <interface>` |
| 510 |
|
| 511 |
- **Expected Output:** Ensure that both sides advertise compatible link modes. |
| 512 |
If autonegotiation is off, verify that both link partners are configured for |
| 513 |
the same speed and duplex. |
| 514 |
|
| 515 |
The following example shows a case where the local PHY advertises fewer link |
| 516 |
modes than it supports. This will reduce the number of overlapping link modes |
| 517 |
with the link partner. In the worst case, there will be no common link modes, |
| 518 |
and the link will not be created: |
| 519 |
|
| 520 |
.. code-block:: bash |
| 521 |
|
| 522 |
Settings for eth0: |
| 523 |
Supported link modes: 1000baseT/Full, 100baseT/Full |
| 524 |
Advertised link modes: 1000baseT/Full |
| 525 |
Speed: 1000Mb/s |
| 526 |
Duplex: Full |
| 527 |
Auto-negotiation: on |
| 528 |
|
| 529 |
Combined Mode Mismatch (Autonegotiation on One Side, Forced on the Other) |
| 530 |
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ |
| 531 |
|
| 532 |
- One possible issue occurs when one side is using **autonegotiation** (as in |
| 533 |
most modern systems), and the other side is set to a **forced link mode** |
| 534 |
(e.g., older hardware with single-speed hubs). In such cases, modern PHYs |
| 535 |
will attempt to detect the forced mode on the other side. If the link is |
| 536 |
established, you may notice: |
| 537 |
|
| 538 |
- **No or empty "Link partner advertised link modes"**. |
| 539 |
|
| 540 |
- **"Link partner advertised auto-negotiation:"** will be **"no"** or not |
| 541 |
present. |
| 542 |
|
| 543 |
- This type of detection does not always work reliably: |
| 544 |
|
| 545 |
- Typically, the modern PHY will default to **Half Duplex**, even if the link |
| 546 |
partner is actually configured for **Full Duplex**. |
| 547 |
|
| 548 |
- Some PHYs may not work reliably if the link partner switches from one |
| 549 |
forced mode to another. In this case, only a down/up cycle may help. |
| 550 |
|
| 551 |
- **Next Steps**: Set both sides to the same fixed speed and duplex mode to |
| 552 |
avoid potential detection issues. |
| 553 |
|
| 554 |
.. code-block:: bash |
| 555 |
|
| 556 |
ethtool -s <interface> speed 1000 duplex full autoneg off |
| 557 |
|
| 558 |
Master/Slave Role Mismatch (BaseT1 and 1000BaseT PHYs) |
| 559 |
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ |
| 560 |
|
| 561 |
- In **BaseT1** systems (e.g., 1000BaseT1, 100BaseT1), link establishment |
| 562 |
requires that one device is configured as **master** and the other as |
| 563 |
**slave**. A mismatch in this master-slave configuration can prevent the link |
| 564 |
from being established. However, **1000BaseT** also supports configurable |
| 565 |
master/slave roles and can face similar issues. |
| 566 |
|
| 567 |
- **Role Preference in 1000BaseT**: The **1000BaseT** specification allows link |
| 568 |
partners to negotiate master-slave roles or role preferences during |
| 569 |
autonegotiation. Some PHYs have hardware limitations or bugs that prevent |
| 570 |
them from functioning properly in certain roles. In such cases, drivers may |
| 571 |
force these PHYs into a specific role (e.g., **forced master** or **forced |
| 572 |
slave**) or try a weaker option by setting preferences. If both link partners |
| 573 |
have the same issue and are forced into the same mode (e.g., both forced into |
| 574 |
master mode), they will not be able to establish a link. |
| 575 |
|
| 576 |
- **Next Steps**: Ensure that one side is configured as **master** and the |
| 577 |
other as **slave** to avoid this issue, particularly when hardware |
| 578 |
limitations are involved, or try the weaker **preferred** option instead of |
| 579 |
**forced**. Check for any driver-related restrictions or forced modes. |
| 580 |
|
| 581 |
- **Command to force master/slave mode**: |
| 582 |
|
| 583 |
.. code-block:: bash |
| 584 |
|
| 585 |
ethtool -s <interface> master-slave forced-master |
| 586 |
|
| 587 |
or: |
| 588 |
|
| 589 |
.. code-block:: bash |
| 590 |
|
| 591 |
ethtool -s <interface> master-slave forced-master speed 1000 duplex full autoneg off |
| 592 |
|
| 593 |
|
| 594 |
- **Check the current master/slave status**: |
| 595 |
|
| 596 |
.. code-block:: bash |
| 597 |
|
| 598 |
ethtool <interface> |
| 599 |
|
| 600 |
Example Output: |
| 601 |
|
| 602 |
.. code-block:: bash |
| 603 |
|
| 604 |
master-slave cfg: forced-master |
| 605 |
master-slave status: master |
| 606 |
|
| 607 |
- **Hardware Bugs and Driver Forcing**: If a known hardware issue forces the |
| 608 |
PHY into a specific mode, it’s essential to check the driver source code or |
| 609 |
hardware documentation for details. Ensure that the roles are compatible |
| 610 |
across both link partners, and if both PHYs are forced into the same mode, |
| 611 |
adjust one side accordingly to resolve the mismatch. |
| 612 |
|
| 613 |
Monitor Link Resets and Speed Drops |
| 614 |
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| 615 |
|
| 616 |
If the link is unstable, showing frequent resets or speed drops, this may |
| 617 |
indicate issues with the cable, PHY configuration, or environmental factors. |
| 618 |
While there is still no completely unified way in Linux to directly monitor |
| 619 |
downshift events or link speed changes via user space tools, both the Linux |
| 620 |
kernel logs and `ethtool` can provide valuable insights, especially if the |
| 621 |
driver supports reporting such events. |
| 622 |
|
| 623 |
- **Monitor Kernel Logs for Link Resets and Speed Drops**: |
| 624 |
|
| 625 |
- The Linux kernel will print link status changes, including downshift |
| 626 |
events, in the system logs. These messages typically include speed changes, |
| 627 |
duplex mode, and downshifted link speed (if the driver supports it). |
| 628 |
|
| 629 |
- **Command to monitor kernel logs in real-time:** |
| 630 |
|
| 631 |
.. code-block:: bash |
| 632 |
|
| 633 |
dmesg -w | grep "Link is Up\|Link is Down" |
| 634 |
|
| 635 |
- Example Output (if a downshift occurs): |
| 636 |
|
| 637 |
.. code-block:: bash |
| 638 |
|
| 639 |
eth0: Link is Up - 100Mbps/Full (downshifted) - flow control rx/tx |
| 640 |
eth0: Link is Down |
| 641 |
|
| 642 |
This indicates that the link has been established but has downshifted from |
| 643 |
a higher speed. |
| 644 |
|
| 645 |
- **Note**: Not all drivers or PHYs support downshift reporting, so you may |
| 646 |
not see this information for all devices. |
| 647 |
|
| 648 |
- **Monitor Link Down Events Using `ethtool`**: |
| 649 |
|
| 650 |
- Starting with the latest kernel and `ethtool` versions, you can track |
| 651 |
**Link Down Events** using the `ethtool -I` command. This will provide |
| 652 |
counters for link drops, helping to diagnose link instability issues if |
| 653 |
supported by the driver. |
| 654 |
|
| 655 |
- **Command to monitor link down events:** |
| 656 |
|
| 657 |
.. code-block:: bash |
| 658 |
|
| 659 |
ethtool -I <interface> |
| 660 |
|
| 661 |
- Example Output (if supported): |
| 662 |
|
| 663 |
.. code-block:: bash |
| 664 |
|
| 665 |
PSE attributes for eth1: |
| 666 |
Link Down Events: 5 |
| 667 |
|
| 668 |
This indicates that the link has dropped 5 times. Frequent link down events |
| 669 |
may indicate cable or environmental issues that require further |
| 670 |
investigation. |
| 671 |
|
| 672 |
- **Check Link Status and Speed**: |
| 673 |
|
| 674 |
- Even though downshift counts or events are not easily tracked, you can |
| 675 |
still use `ethtool` to manually check the current link speed and status. |
| 676 |
|
| 677 |
- **Command:** `ethtool <interface>` |
| 678 |
|
| 679 |
- **Expected Output:** |
| 680 |
|
| 681 |
.. code-block:: bash |
| 682 |
|
| 683 |
Speed: 1000Mb/s |
| 684 |
Duplex: Full |
| 685 |
Auto-negotiation: on |
| 686 |
Link detected: yes |
| 687 |
|
| 688 |
Any inconsistencies in the expected speed or duplex setting could indicate |
| 689 |
an issue. |
| 690 |
|
| 691 |
- **Disable Energy-Efficient Ethernet (EEE) for Diagnostics**: |
| 692 |
|
| 693 |
- **EEE** (Energy-Efficient Ethernet) can be a source of link instability due |
| 694 |
to transitions in and out of low-power states. For diagnostic purposes, it |
| 695 |
may be useful to **temporarily** disable EEE to determine if it is |
| 696 |
contributing to link instability. This is **not a generic recommendation** |
| 697 |
for disabling power management. |
| 698 |
|
| 699 |
- **Next Steps**: Disable EEE and monitor if the link becomes stable. If |
| 700 |
disabling EEE resolves the issue, report the bug so that the driver can be |
| 701 |
fixed. |
| 702 |
|
| 703 |
- **Command:** |
| 704 |
|
| 705 |
.. code-block:: bash |
| 706 |
|
| 707 |
ethtool --set-eee <interface> eee off |
| 708 |
|
| 709 |
- **Important**: If disabling EEE resolves the instability, the issue should |
| 710 |
be reported to the maintainers as a bug, and the driver should be corrected |
| 711 |
to handle EEE properly without causing instability. Disabling EEE |
| 712 |
permanently should not be seen as a solution. |
| 713 |
|
| 714 |
- **Monitor Error Counters**: |
| 715 |
|
| 716 |
- Use `ethtool -S <interface> --all-groups` to retrieve standardized interface |
| 717 |
statistics if the driver supports the unified interface: |
| 718 |
|
| 719 |
- **Command:** `ethtool -S <interface> --all-groups` |
| 720 |
|
| 721 |
- **Example Output (if supported)**: |
| 722 |
|
| 723 |
.. code-block:: bash |
| 724 |
|
| 725 |
phydev-RxFrames: 100391 |
| 726 |
phydev-RxErrors: 0 |
| 727 |
phydev-TxFrames: 9 |
| 728 |
phydev-TxErrors: 0 |
| 729 |
|
| 730 |
- If the unified interface is not supported, use `ethtool -S <interface>` to |
| 731 |
retrieve MAC and PHY counters. Note that non-standardized PHY counter names |
| 732 |
vary by driver and must be interpreted accordingly: |
| 733 |
|
| 734 |
- **Command:** `ethtool -S <interface>` |
| 735 |
|
| 736 |
- **Example Output (if supported)**: |
| 737 |
|
| 738 |
.. code-block:: bash |
| 739 |
|
| 740 |
rx_crc_errors: 123 |
| 741 |
tx_errors: 45 |
| 742 |
rx_frame_errors: 78 |
| 743 |
|
| 744 |
- **Note**: If no meaningful error counters are available or if counters are |
| 745 |
not supported, you may need to rely on physical inspections (e.g., cable |
| 746 |
condition) or kernel log messages (e.g., link up/down events) to further |
| 747 |
diagnose the issue. |
| 748 |
|
| 749 |
- **Compare Counters**: |
| 750 |
|
| 751 |
- Compare the egress and ingress frame counts reported by the PHY and MAC. |
| 752 |
|
| 753 |
- A small difference may occur due to sampling rate differences between the |
| 754 |
MAC and PHY drivers, or if the PHY and MAC are not always fully |
| 755 |
synchronized in their UP or DOWN states. |
| 756 |
|
| 757 |
- Significant discrepancies indicate potential issues in the data path |
| 758 |
between the MAC and PHY. |
| 759 |
|
| 760 |
When All Else Fails... |
| 761 |
~~~~~~~~~~~~~~~~~~~~~~ |
| 762 |
|
| 763 |
So you've checked the cables, monitored the logs, disabled EEE, and still... |
| 764 |
nothing? Don’t worry, you’re not alone. Sometimes, Ethernet gremlins just don’t |
| 765 |
want to cooperate. |
| 766 |
|
| 767 |
But before you throw in the towel (or the Ethernet cable), take a deep breath. |
| 768 |
It’s always possible that: |
| 769 |
|
| 770 |
1. Your PHY has a unique, undocumented personality. |
| 771 |
|
| 772 |
2. The problem is lying dormant, waiting for just the right moment to magically |
| 773 |
resolve itself (hey, it happens!). |
| 774 |
|
| 775 |
3. Or, it could be that the ultimate solution simply hasn’t been invented yet. |
| 776 |
|
| 777 |
If none of the above bring you comfort, there’s one final step: contribute! If |
| 778 |
you've uncovered new or unusual issues, or have creative diagnostic methods, |
| 779 |
feel free to share your findings and extend this documentation. Together, we |
| 780 |
can hunt down every elusive network issue - one twisted pair at a time. |
| 781 |
|
| 782 |
Remember: sometimes the solution is just a reboot away, but if not, it’s time to |
| 783 |
dig deeper - or report that bug! |