| 1 |
.. SPDX-License-Identifier: GPL-2.0+ |
| 2 |
|
| 3 |
====================================================== |
| 4 |
IBM Virtual Management Channel Kernel Driver (IBMVMC) |
| 5 |
====================================================== |
| 6 |
|
| 7 |
:Authors: |
| 8 |
Dave Engebretsen <[email protected]>, |
| 9 |
Adam Reznechek <[email protected]>, |
| 10 |
Steven Royer <[email protected]>, |
| 11 |
Bryant G. Ly <[email protected]>, |
| 12 |
|
| 13 |
Introduction |
| 14 |
============ |
| 15 |
|
| 16 |
Note: Knowledge of virtualization technology is required to understand |
| 17 |
this document. |
| 18 |
|
| 19 |
A good reference document would be: |
| 20 |
|
| 21 |
https://openpowerfoundation.org/wp-content/uploads/2016/05/LoPAPR_DRAFT_v11_24March2016_cmt1.pdf |
| 22 |
|
| 23 |
The Virtual Management Channel (VMC) is a logical device which provides an |
| 24 |
interface between the hypervisor and a management partition. This interface |
| 25 |
is like a message passing interface. This management partition is intended |
| 26 |
to provide an alternative to systems that use a Hardware Management |
| 27 |
Console (HMC) - based system management. |
| 28 |
|
| 29 |
The primary hardware management solution that is developed by IBM relies |
| 30 |
on an appliance server named the Hardware Management Console (HMC), |
| 31 |
packaged as an external tower or rack-mounted personal computer. In a |
| 32 |
Power Systems environment, a single HMC can manage multiple POWER |
| 33 |
processor-based systems. |
| 34 |
|
| 35 |
Management Application |
| 36 |
---------------------- |
| 37 |
|
| 38 |
In the management partition, a management application exists which enables |
| 39 |
a system administrator to configure the system’s partitioning |
| 40 |
characteristics via a command line interface (CLI) or Representational |
| 41 |
State Transfer Application (REST API's). |
| 42 |
|
| 43 |
The management application runs on a Linux logical partition on a |
| 44 |
POWER8 or newer processor-based server that is virtualized by PowerVM. |
| 45 |
System configuration, maintenance, and control functions which |
| 46 |
traditionally require an HMC can be implemented in the management |
| 47 |
application using a combination of HMC to hypervisor interfaces and |
| 48 |
existing operating system methods. This tool provides a subset of the |
| 49 |
functions implemented by the HMC and enables basic partition configuration. |
| 50 |
The set of HMC to hypervisor messages supported by the management |
| 51 |
application component are passed to the hypervisor over a VMC interface, |
| 52 |
which is defined below. |
| 53 |
|
| 54 |
The VMC enables the management partition to provide basic partitioning |
| 55 |
functions: |
| 56 |
|
| 57 |
- Logical Partitioning Configuration |
| 58 |
- Start, and stop actions for individual partitions |
| 59 |
- Display of partition status |
| 60 |
- Management of virtual Ethernet |
| 61 |
- Management of virtual Storage |
| 62 |
- Basic system management |
| 63 |
|
| 64 |
Virtual Management Channel (VMC) |
| 65 |
-------------------------------- |
| 66 |
|
| 67 |
A logical device, called the Virtual Management Channel (VMC), is defined |
| 68 |
for communicating between the management application and the hypervisor. It |
| 69 |
basically creates the pipes that enable virtualization management |
| 70 |
software. This device is presented to a designated management partition as |
| 71 |
a virtual device. |
| 72 |
|
| 73 |
This communication device uses Command/Response Queue (CRQ) and the |
| 74 |
Remote Direct Memory Access (RDMA) interfaces. A three-way handshake is |
| 75 |
defined that must take place to establish that both the hypervisor and |
| 76 |
management partition sides of the channel are running prior to |
| 77 |
sending/receiving any of the protocol messages. |
| 78 |
|
| 79 |
This driver also utilizes Transport Event CRQs. CRQ messages are sent |
| 80 |
when the hypervisor detects one of the peer partitions has abnormally |
| 81 |
terminated, or one side has called H_FREE_CRQ to close their CRQ. |
| 82 |
Two new classes of CRQ messages are introduced for the VMC device. VMC |
| 83 |
Administrative messages are used for each partition using the VMC to |
| 84 |
communicate capabilities to their partner. HMC Interface messages are used |
| 85 |
for the actual flow of HMC messages between the management partition and |
| 86 |
the hypervisor. As most HMC messages far exceed the size of a CRQ buffer, |
| 87 |
a virtual DMA (RMDA) of the HMC message data is done prior to each HMC |
| 88 |
Interface CRQ message. Only the management partition drives RDMA |
| 89 |
operations; hypervisors never directly cause the movement of message data. |
| 90 |
|
| 91 |
|
| 92 |
Terminology |
| 93 |
----------- |
| 94 |
RDMA |
| 95 |
Remote Direct Memory Access is DMA transfer from the server to its |
| 96 |
client or from the server to its partner partition. DMA refers |
| 97 |
to both physical I/O to and from memory operations and to memory |
| 98 |
to memory move operations. |
| 99 |
CRQ |
| 100 |
Command/Response Queue a facility which is used to communicate |
| 101 |
between partner partitions. Transport events which are signaled |
| 102 |
from the hypervisor to partition are also reported in this queue. |
| 103 |
|
| 104 |
Example Management Partition VMC Driver Interface |
| 105 |
================================================= |
| 106 |
|
| 107 |
This section provides an example for the management application |
| 108 |
implementation where a device driver is used to interface to the VMC |
| 109 |
device. This driver consists of a new device, for example /dev/ibmvmc, |
| 110 |
which provides interfaces to open, close, read, write, and perform |
| 111 |
ioctl’s against the VMC device. |
| 112 |
|
| 113 |
VMC Interface Initialization |
| 114 |
---------------------------- |
| 115 |
|
| 116 |
The device driver is responsible for initializing the VMC when the driver |
| 117 |
is loaded. It first creates and initializes the CRQ. Next, an exchange of |
| 118 |
VMC capabilities is performed to indicate the code version and number of |
| 119 |
resources available in both the management partition and the hypervisor. |
| 120 |
Finally, the hypervisor requests that the management partition create an |
| 121 |
initial pool of VMC buffers, one buffer for each possible HMC connection, |
| 122 |
which will be used for management application session initialization. |
| 123 |
Prior to completion of this initialization sequence, the device returns |
| 124 |
EBUSY to open() calls. EIO is returned for all open() failures. |
| 125 |
|
| 126 |
:: |
| 127 |
|
| 128 |
Management Partition Hypervisor |
| 129 |
CRQ INIT |
| 130 |
----------------------------------------> |
| 131 |
CRQ INIT COMPLETE |
| 132 |
<---------------------------------------- |
| 133 |
CAPABILITIES |
| 134 |
----------------------------------------> |
| 135 |
CAPABILITIES RESPONSE |
| 136 |
<---------------------------------------- |
| 137 |
ADD BUFFER (HMC IDX=0,1,..) _ |
| 138 |
<---------------------------------------- | |
| 139 |
ADD BUFFER RESPONSE | - Perform # HMCs Iterations |
| 140 |
----------------------------------------> - |
| 141 |
|
| 142 |
VMC Interface Open |
| 143 |
------------------ |
| 144 |
|
| 145 |
After the basic VMC channel has been initialized, an HMC session level |
| 146 |
connection can be established. The application layer performs an open() to |
| 147 |
the VMC device and executes an ioctl() against it, indicating the HMC ID |
| 148 |
(32 bytes of data) for this session. If the VMC device is in an invalid |
| 149 |
state, EIO will be returned for the ioctl(). The device driver creates a |
| 150 |
new HMC session value (ranging from 1 to 255) and HMC index value (starting |
| 151 |
at index 0 and ranging to 254) for this HMC ID. The driver then does an |
| 152 |
RDMA of the HMC ID to the hypervisor, and then sends an Interface Open |
| 153 |
message to the hypervisor to establish the session over the VMC. After the |
| 154 |
hypervisor receives this information, it sends Add Buffer messages to the |
| 155 |
management partition to seed an initial pool of buffers for the new HMC |
| 156 |
connection. Finally, the hypervisor sends an Interface Open Response |
| 157 |
message, to indicate that it is ready for normal runtime messaging. The |
| 158 |
following illustrates this VMC flow: |
| 159 |
|
| 160 |
:: |
| 161 |
|
| 162 |
Management Partition Hypervisor |
| 163 |
RDMA HMC ID |
| 164 |
----------------------------------------> |
| 165 |
Interface Open |
| 166 |
----------------------------------------> |
| 167 |
Add Buffer _ |
| 168 |
<---------------------------------------- | |
| 169 |
Add Buffer Response | - Perform N Iterations |
| 170 |
----------------------------------------> - |
| 171 |
Interface Open Response |
| 172 |
<---------------------------------------- |
| 173 |
|
| 174 |
VMC Interface Runtime |
| 175 |
--------------------- |
| 176 |
|
| 177 |
During normal runtime, the management application and the hypervisor |
| 178 |
exchange HMC messages via the Signal VMC message and RDMA operations. When |
| 179 |
sending data to the hypervisor, the management application performs a |
| 180 |
write() to the VMC device, and the driver RDMA’s the data to the hypervisor |
| 181 |
and then sends a Signal Message. If a write() is attempted before VMC |
| 182 |
device buffers have been made available by the hypervisor, or no buffers |
| 183 |
are currently available, EBUSY is returned in response to the write(). A |
| 184 |
write() will return EIO for all other errors, such as an invalid device |
| 185 |
state. When the hypervisor sends a message to the management, the data is |
| 186 |
put into a VMC buffer and an Signal Message is sent to the VMC driver in |
| 187 |
the management partition. The driver RDMA’s the buffer into the partition |
| 188 |
and passes the data up to the appropriate management application via a |
| 189 |
read() to the VMC device. The read() request blocks if there is no buffer |
| 190 |
available to read. The management application may use select() to wait for |
| 191 |
the VMC device to become ready with data to read. |
| 192 |
|
| 193 |
:: |
| 194 |
|
| 195 |
Management Partition Hypervisor |
| 196 |
MSG RDMA |
| 197 |
----------------------------------------> |
| 198 |
SIGNAL MSG |
| 199 |
----------------------------------------> |
| 200 |
SIGNAL MSG |
| 201 |
<---------------------------------------- |
| 202 |
MSG RDMA |
| 203 |
<---------------------------------------- |
| 204 |
|
| 205 |
VMC Interface Close |
| 206 |
------------------- |
| 207 |
|
| 208 |
HMC session level connections are closed by the management partition when |
| 209 |
the application layer performs a close() against the device. This action |
| 210 |
results in an Interface Close message flowing to the hypervisor, which |
| 211 |
causes the session to be terminated. The device driver must free any |
| 212 |
storage allocated for buffers for this HMC connection. |
| 213 |
|
| 214 |
:: |
| 215 |
|
| 216 |
Management Partition Hypervisor |
| 217 |
INTERFACE CLOSE |
| 218 |
----------------------------------------> |
| 219 |
INTERFACE CLOSE RESPONSE |
| 220 |
<---------------------------------------- |
| 221 |
|
| 222 |
Additional Information |
| 223 |
====================== |
| 224 |
|
| 225 |
For more information on the documentation for CRQ Messages, VMC Messages, |
| 226 |
HMC interface Buffers, and signal messages please refer to the Linux on |
| 227 |
Power Architecture Platform Reference. Section F. |