| 1 |
.. SPDX-License-Identifier: GPL-2.0 |
| 2 |
|
| 3 |
========================================= |
| 4 |
The device for Mediatek MT6370 RGB LED |
| 5 |
========================================= |
| 6 |
|
| 7 |
Description |
| 8 |
----------- |
| 9 |
|
| 10 |
The MT6370 integrates a four-channel RGB LED driver, designed to provide a |
| 11 |
variety of lighting effect for mobile device applications. The RGB LED devices |
| 12 |
includes a smart LED string controller and it can drive 3 channels of LEDs with |
| 13 |
a sink current up to 24mA and a CHG_VIN power good indicator LED with sink |
| 14 |
current up to 6mA. It provides three operation modes for RGB LEDs: |
| 15 |
PWM Dimming mode, breath pattern mode, and constant current mode. The device |
| 16 |
can increase or decrease the brightness of the RGB LED via an I2C interface. |
| 17 |
|
| 18 |
The breath pattern for a channel can be programmed using the "pattern" trigger, |
| 19 |
using the hw_pattern attribute. |
| 20 |
|
| 21 |
/sys/class/leds/<led>/hw_pattern |
| 22 |
-------------------------------- |
| 23 |
|
| 24 |
Specify a hardware breath pattern for a MT6370 RGB LED. |
| 25 |
|
| 26 |
The breath pattern is a series of timing pairs, with the hold-time expressed in |
| 27 |
milliseconds. And the brightness is controlled by |
| 28 |
'/sys/class/leds/<led>/brightness'. The pattern doesn't include the brightness |
| 29 |
setting. Hardware pattern only controls the timing for each pattern stage |
| 30 |
depending on the current brightness setting. |
| 31 |
|
| 32 |
Pattern diagram:: |
| 33 |
|
| 34 |
"0 Tr1 0 Tr2 0 Tf1 0 Tf2 0 Ton 0 Toff" --> '0' for dummy brightness code |
| 35 |
|
| 36 |
^ |
| 37 |
| ============ |
| 38 |
| / \ / |
| 39 |
Icurr | / \ / |
| 40 |
| / \ / |
| 41 |
| / \ / .....repeat |
| 42 |
| / \ / |
| 43 |
| --- --- --- |
| 44 |
|--- --- --- |
| 45 |
+----------------------------------============------------> Time |
| 46 |
< Tr1><Tr2>< Ton ><Tf1><Tf2 >< Toff >< Tr1><Tr2> |
| 47 |
|
| 48 |
Timing description: |
| 49 |
|
| 50 |
* Tr1: First rising time for 0% - 30% load. |
| 51 |
* Tr2: Second rising time for 31% - 100% load. |
| 52 |
* Ton: On time for 100% load. |
| 53 |
* Tf1: First falling time for 100% - 31% load. |
| 54 |
* Tf2: Second falling time for 30% to 0% load. |
| 55 |
* Toff: Off time for 0% load. |
| 56 |
|
| 57 |
* Tr1/Tr2/Tf1/Tf2/Ton: 125ms to 3125ms, 200ms per step. |
| 58 |
* Toff: 250ms to 6250ms, 400ms per step. |
| 59 |
|
| 60 |
Pattern example:: |
| 61 |
|
| 62 |
"0 125 0 125 0 125 0 125 0 625 0 1050" |
| 63 |
|
| 64 |
This Will configure Tr1/Tr2/Tf1/Tf2 to 125m, Ton to 625ms, and Toff to 1050ms. |