BNO055 driver |
| 5 |
============================== |
| 6 |
|
| 7 |
1. Overview |
| 8 |
=========== |
| 9 |
|
| 10 |
This driver supports Bosch BNO055 IMUs (on both serial and I2C busses). |
| 11 |
|
| 12 |
Accelerometer, magnetometer and gyroscope measurements are always available. |
| 13 |
When "fusion_enable" sysfs attribute is set to 1, orientation (both Euler |
| 14 |
angles and quaternion), linear velocity and gravity vector are also |
| 15 |
provided, but some sensor settings (e.g. low pass filtering and range) |
| 16 |
become locked (the IMU firmware controls them). |
| 17 |
|
| 18 |
This driver supports also IIO buffers. |
| 19 |
|
| 20 |
2. Calibration |
| 21 |
============== |
| 22 |
|
| 23 |
The IMU continuously performs an autocalibration procedure if (and only if) |
| 24 |
operating in fusion mode. The magnetometer autocalibration can however be |
| 25 |
disabled by writing 0 in the sysfs in_magn_calibration_fast_enable attribute. |
| 26 |
|
| 27 |
The driver provides access to autocalibration flags (i.e. you can determine |
| 28 |
if the IMU has successfully autocalibrated) and to the calibration data blob. |
| 29 |
|
| 30 |
The user can save this blob in a firmware file (i.e. in /lib/firmware) that |
| 31 |
the driver looks for at probe time. If found, then the IMU is initialized |
| 32 |
with this calibration data. This saves the user from performing the |
| 33 |
calibration procedure every time (which consists of moving the IMU in |
| 34 |
various ways). |
| 35 |
|
| 36 |
The driver looks for calibration data file using two different names: first |
| 37 |
a file whose name is suffixed with the IMU unique ID (exposed in sysfs as |
| 38 |
serial_number) is searched for; this is useful when there is more than one |
| 39 |
IMU instance. If this file is not found, then a "generic" calibration file |
| 40 |
is searched for (which can be used when only one IMU is present, without |
| 41 |
struggling with fancy names, that change on each device). |
| 42 |
|
| 43 |
Valid calibration file names would be e.g. |
| 44 |
bno055-caldata-0e7c26a33541515120204a35342b04ff.dat |
| 45 |
bno055-caldata.dat |
| 46 |
|
| 47 |
In non-fusion mode the IIO 'offset' attributes provide access to the |
| 48 |
offsets from calibration data (if any), so that the user can apply them to |
| 49 |
the accel, angvel and magn IIO attributes. In fusion mode they are not |
| 50 |
needed (the IMU firmware internally applies those corrections) and they |
| 51 |
read as zero. |