| 1 |
# SPDX-License-Identifier: (GPL-2.0) |
| 2 |
# Copyright 2020 Linaro Ltd. |
| 3 |
%YAML 1.2 |
| 4 |
--- |
| 5 |
$id: http://devicetree.org/schemas/thermal/thermal-cooling-devices.yaml# |
| 6 |
$schema: http://devicetree.org/meta-schemas/core.yaml# |
| 7 |
|
| 8 |
title: Thermal cooling device |
| 9 |
|
| 10 |
maintainers: |
| 11 |
- Amit Kucheria <[email protected]> |
| 12 |
|
| 13 |
description: | |
| 14 |
Thermal management is achieved in devicetree by describing the sensor hardware |
| 15 |
and the software abstraction of cooling devices and thermal zones required to |
| 16 |
take appropriate action to mitigate thermal overload. |
| 17 |
|
| 18 |
The following node types are used to completely describe a thermal management |
| 19 |
system in devicetree: |
| 20 |
- thermal-sensor: device that measures temperature, has SoC-specific bindings |
| 21 |
- cooling-device: device used to dissipate heat either passively or actively |
| 22 |
- thermal-zones: a container of the following node types used to describe all |
| 23 |
thermal data for the platform |
| 24 |
|
| 25 |
This binding describes the cooling devices. |
| 26 |
|
| 27 |
There are essentially two ways to provide control on power dissipation: |
| 28 |
- Passive cooling: by means of regulating device performance. A typical |
| 29 |
passive cooling mechanism is a CPU that has dynamic voltage and frequency |
| 30 |
scaling (DVFS), and uses lower frequencies as cooling states. |
| 31 |
- Active cooling: by means of activating devices in order to remove the |
| 32 |
dissipated heat, e.g. regulating fan speeds. |
| 33 |
|
| 34 |
Any cooling device has a range of cooling states (i.e. different levels of |
| 35 |
heat dissipation). They also have a way to determine the state of cooling in |
| 36 |
which the device is. For example, a fan's cooling states correspond to the |
| 37 |
different fan speeds possible. Cooling states are referred to by single |
| 38 |
unsigned integers, where larger numbers mean greater heat dissipation. The |
| 39 |
precise set of cooling states associated with a device should be defined in |
| 40 |
a particular device's binding. |
| 41 |
|
| 42 |
select: true |
| 43 |
|
| 44 |
properties: |
| 45 |
"#cooling-cells": |
| 46 |
description: |
| 47 |
Must be 2, in order to specify minimum and maximum cooling state used in |
| 48 |
the cooling-maps reference. The first cell is the minimum cooling state |
| 49 |
and the second cell is the maximum cooling state requested. |
| 50 |
const: 2 |
| 51 |
|
| 52 |
additionalProperties: true |
| 53 |
|
| 54 |
examples: |
| 55 |
- | |
| 56 |
#include <dt-bindings/interrupt-controller/arm-gic.h> |
| 57 |
#include <dt-bindings/thermal/thermal.h> |
| 58 |
|
| 59 |
// Example 1: Cpufreq cooling device on CPU0 |
| 60 |
cpus { |
| 61 |
#address-cells = <2>; |
| 62 |
#size-cells = <0>; |
| 63 |
|
| 64 |
CPU0: cpu@0 { |
| 65 |
device_type = "cpu"; |
| 66 |
compatible = "qcom,kryo385"; |
| 67 |
reg = <0x0 0x0>; |
| 68 |
enable-method = "psci"; |
| 69 |
cpu-idle-states = <&LITTLE_CPU_SLEEP_0>, |
| 70 |
<&LITTLE_CPU_SLEEP_1>, |
| 71 |
<&CLUSTER_SLEEP_0>; |
| 72 |
capacity-dmips-mhz = <607>; |
| 73 |
dynamic-power-coefficient = <100>; |
| 74 |
qcom,freq-domain = <&cpufreq_hw 0>; |
| 75 |
#cooling-cells = <2>; |
| 76 |
next-level-cache = <&L2_0>; |
| 77 |
L2_0: l2-cache { |
| 78 |
compatible = "cache"; |
| 79 |
cache-unified; |
| 80 |
cache-level = <2>; |
| 81 |
next-level-cache = <&L3_0>; |
| 82 |
L3_0: l3-cache { |
| 83 |
compatible = "cache"; |
| 84 |
cache-unified; |
| 85 |
cache-level = <3>; |
| 86 |
}; |
| 87 |
}; |
| 88 |
}; |
| 89 |
|
| 90 |
/* ... */ |
| 91 |
|
| 92 |
}; |
| 93 |
|
| 94 |
/* ... */ |
| 95 |
|
| 96 |
thermal-zones { |
| 97 |
cpu0-thermal { |
| 98 |
polling-delay-passive = <250>; |
| 99 |
polling-delay = <1000>; |
| 100 |
|
| 101 |
thermal-sensors = <&tsens0 1>; |
| 102 |
|
| 103 |
trips { |
| 104 |
cpu0_alert0: trip-point0 { |
| 105 |
temperature = <90000>; |
| 106 |
hysteresis = <2000>; |
| 107 |
type = "passive"; |
| 108 |
}; |
| 109 |
}; |
| 110 |
|
| 111 |
cooling-maps { |
| 112 |
map0 { |
| 113 |
trip = <&cpu0_alert0>; |
| 114 |
/* Corresponds to 1000MHz in OPP table */ |
| 115 |
cooling-device = <&CPU0 5 5>; |
| 116 |
}; |
| 117 |
}; |
| 118 |
}; |
| 119 |
|
| 120 |
/* ... */ |
| 121 |
}; |
| 122 |
... |