| 1 |
Cadence Real Time Clock |
| 2 |
|
| 3 |
The Cadence RTC controller with date, time and alarm capabilities. |
| 4 |
The alarm may wake the system from low-power state. |
| 5 |
|
| 6 |
Required properties: |
| 7 |
- compatible: Should be "cdns,rtc-r109v3" |
| 8 |
- reg: Specifies base physical address and size of the register area. |
| 9 |
- interrupts: A single interrupt specifier. |
| 10 |
- clocks: Must contain two entries: |
| 11 |
- pclk: APB registers clock |
| 12 |
- ref_clk: reference 1Hz or 100Hz clock, depending on IP configuration |
| 13 |
See ../clocks/clock-bindings.txt for details. |
| 14 |
|
| 15 |
Example: |
| 16 |
rtc0: rtc@fd080000 { |
| 17 |
compatible = "cdns,rtc-r109v3"; |
| 18 |
reg = <0xfd080000 0x1000>; |
| 19 |
|
| 20 |
clock-names = "pclk", "ref_clk"; |
| 21 |
clocks = <&sysclock>, <&refclock>; |
| 22 |
|
| 23 |
interrupt-parent = <&gic>; |
| 24 |
interrupts = <0 6 IRQ_TYPE_LEVEL_HIGH>; |
| 25 |
}; |