| 1 |
# SPDX-License-Identifier: GPL-2.0 |
| 2 |
%YAML 1.2 |
| 3 |
--- |
| 4 |
$id: http://devicetree.org/schemas/regulator/regulator.yaml# |
| 5 |
$schema: http://devicetree.org/meta-schemas/core.yaml# |
| 6 |
|
| 7 |
title: Voltage/Current Regulators |
| 8 |
|
| 9 |
maintainers: |
| 10 |
- Liam Girdwood <[email protected]> |
| 11 |
- Mark Brown <[email protected]> |
| 12 |
|
| 13 |
properties: |
| 14 |
regulator-name: |
| 15 |
description: A string used as a descriptive name for regulator outputs |
| 16 |
$ref: /schemas/types.yaml#/definitions/string |
| 17 |
|
| 18 |
regulator-min-microvolt: |
| 19 |
description: smallest voltage consumers may set |
| 20 |
|
| 21 |
regulator-max-microvolt: |
| 22 |
description: largest voltage consumers may set |
| 23 |
|
| 24 |
regulator-microvolt-offset: |
| 25 |
description: Offset applied to voltages to compensate for voltage drops |
| 26 |
$ref: /schemas/types.yaml#/definitions/uint32 |
| 27 |
|
| 28 |
regulator-min-microamp: |
| 29 |
description: smallest current consumers may set |
| 30 |
|
| 31 |
regulator-max-microamp: |
| 32 |
description: largest current consumers may set |
| 33 |
|
| 34 |
regulator-input-current-limit-microamp: |
| 35 |
description: maximum input current regulator allows |
| 36 |
|
| 37 |
regulator-power-budget-milliwatt: |
| 38 |
description: power budget of the regulator |
| 39 |
|
| 40 |
regulator-always-on: |
| 41 |
description: boolean, regulator should never be disabled |
| 42 |
type: boolean |
| 43 |
|
| 44 |
regulator-boot-on: |
| 45 |
description: bootloader/firmware enabled regulator. |
| 46 |
It's expected that this regulator was left on by the bootloader. |
| 47 |
If the bootloader didn't leave it on then OS should turn it on |
| 48 |
at boot but shouldn't prevent it from being turned off later. |
| 49 |
This property is intended to only be used for regulators where |
| 50 |
software cannot read the state of the regulator. |
| 51 |
type: boolean |
| 52 |
|
| 53 |
regulator-allow-bypass: |
| 54 |
description: allow the regulator to go into bypass mode |
| 55 |
type: boolean |
| 56 |
|
| 57 |
regulator-allow-set-load: |
| 58 |
description: allow the regulator performance level to be configured |
| 59 |
type: boolean |
| 60 |
|
| 61 |
regulator-ramp-delay: |
| 62 |
description: ramp delay for regulator(in uV/us) For hardware which supports |
| 63 |
disabling ramp rate, it should be explicitly initialised to zero (regulator-ramp-delay |
| 64 |
= <0>) for disabling ramp delay. |
| 65 |
$ref: /schemas/types.yaml#/definitions/uint32 |
| 66 |
|
| 67 |
regulator-enable-ramp-delay: |
| 68 |
description: The time taken, in microseconds, for the supply rail to |
| 69 |
reach the target voltage, plus/minus whatever tolerance the board |
| 70 |
design requires. This property describes the total system ramp time |
| 71 |
required due to the combination of internal ramping of the regulator |
| 72 |
itself, and board design issues such as trace capacitance and load |
| 73 |
on the supply. |
| 74 |
$ref: /schemas/types.yaml#/definitions/uint32 |
| 75 |
|
| 76 |
regulator-settling-time-us: |
| 77 |
description: Settling time, in microseconds, for voltage change if regulator |
| 78 |
have the constant time for any level voltage change. This is useful |
| 79 |
when regulator have exponential voltage change. |
| 80 |
|
| 81 |
regulator-settling-time-up-us: |
| 82 |
description: Settling time, in microseconds, for voltage increase if |
| 83 |
the regulator needs a constant time to settle after voltage increases |
| 84 |
of any level. This is useful for regulators with exponential voltage |
| 85 |
changes. |
| 86 |
|
| 87 |
regulator-settling-time-down-us: |
| 88 |
description: Settling time, in microseconds, for voltage decrease if |
| 89 |
the regulator needs a constant time to settle after voltage decreases |
| 90 |
of any level. This is useful for regulators with exponential voltage |
| 91 |
changes. |
| 92 |
|
| 93 |
regulator-soft-start: |
| 94 |
description: Enable soft start so that voltage ramps slowly |
| 95 |
type: boolean |
| 96 |
|
| 97 |
regulator-initial-mode: |
| 98 |
description: initial operating mode. The set of possible operating modes |
| 99 |
depends on the capabilities of every hardware so each device binding |
| 100 |
documentation explains which values the regulator supports. |
| 101 |
$ref: /schemas/types.yaml#/definitions/uint32 |
| 102 |
|
| 103 |
regulator-allowed-modes: |
| 104 |
description: list of operating modes that software is allowed to configure |
| 105 |
for the regulator at run-time. Elements may be specified in any order. |
| 106 |
The set of possible operating modes depends on the capabilities of |
| 107 |
every hardware so each device binding document explains which values |
| 108 |
the regulator supports. |
| 109 |
$ref: /schemas/types.yaml#/definitions/uint32-array |
| 110 |
|
| 111 |
regulator-system-load: |
| 112 |
description: Load in uA present on regulator that is not captured by |
| 113 |
any consumer request. |
| 114 |
$ref: /schemas/types.yaml#/definitions/uint32 |
| 115 |
|
| 116 |
regulator-pull-down: |
| 117 |
description: Enable pull down resistor when the regulator is disabled. |
| 118 |
type: boolean |
| 119 |
|
| 120 |
system-critical-regulator: |
| 121 |
description: Set if the regulator is critical to system stability or |
| 122 |
functionality. |
| 123 |
type: boolean |
| 124 |
|
| 125 |
regulator-over-current-protection: |
| 126 |
description: Enable over current protection. |
| 127 |
type: boolean |
| 128 |
|
| 129 |
regulator-oc-protection-microamp: |
| 130 |
description: Set over current protection limit. This is a limit where |
| 131 |
hardware performs emergency shutdown. Zero can be passed to disable |
| 132 |
protection and value '1' indicates that protection should be enabled but |
| 133 |
limit setting can be omitted. |
| 134 |
|
| 135 |
regulator-oc-error-microamp: |
| 136 |
description: Set over current error limit. This is a limit where part of |
| 137 |
the hardware probably is malfunctional and damage prevention is requested. |
| 138 |
Zero can be passed to disable error detection and value '1' indicates |
| 139 |
that detection should be enabled but limit setting can be omitted. |
| 140 |
|
| 141 |
regulator-oc-warn-microamp: |
| 142 |
description: Set over current warning limit. This is a limit where hardware |
| 143 |
is assumed still to be functional but approaching limit where it gets |
| 144 |
damaged. Recovery actions should be initiated. Zero can be passed to |
| 145 |
disable detection and value '1' indicates that detection should |
| 146 |
be enabled but limit setting can be omitted. |
| 147 |
|
| 148 |
regulator-ov-protection-microvolt: |
| 149 |
description: Set over voltage protection limit. This is a limit where |
| 150 |
hardware performs emergency shutdown. Zero can be passed to disable |
| 151 |
protection and value '1' indicates that protection should be enabled but |
| 152 |
limit setting can be omitted. Limit is given as microvolt offset from |
| 153 |
voltage set to regulator. |
| 154 |
|
| 155 |
regulator-ov-error-microvolt: |
| 156 |
description: Set over voltage error limit. This is a limit where part of |
| 157 |
the hardware probably is malfunctional and damage prevention is requested |
| 158 |
Zero can be passed to disable error detection and value '1' indicates |
| 159 |
that detection should be enabled but limit setting can be omitted. Limit |
| 160 |
is given as microvolt offset from voltage set to regulator. |
| 161 |
|
| 162 |
regulator-ov-warn-microvolt: |
| 163 |
description: Set over voltage warning limit. This is a limit where hardware |
| 164 |
is assumed still to be functional but approaching limit where it gets |
| 165 |
damaged. Recovery actions should be initiated. Zero can be passed to |
| 166 |
disable detection and value '1' indicates that detection should |
| 167 |
be enabled but limit setting can be omitted. Limit is given as microvolt |
| 168 |
offset from voltage set to regulator. |
| 169 |
|
| 170 |
regulator-uv-protection-microvolt: |
| 171 |
description: Set under voltage protection limit. This is a limit where |
| 172 |
hardware performs emergency shutdown. Zero can be passed to disable |
| 173 |
protection and value '1' indicates that protection should be enabled but |
| 174 |
limit setting can be omitted. Limit is given as microvolt offset from |
| 175 |
voltage set to regulator. |
| 176 |
|
| 177 |
regulator-uv-error-microvolt: |
| 178 |
description: Set under voltage error limit. This is a limit where part of |
| 179 |
the hardware probably is malfunctional and damage prevention is requested |
| 180 |
Zero can be passed to disable error detection and value '1' indicates |
| 181 |
that detection should be enabled but limit setting can be omitted. Limit |
| 182 |
is given as microvolt offset from voltage set to regulator. |
| 183 |
|
| 184 |
regulator-uv-warn-microvolt: |
| 185 |
description: Set under voltage warning limit. This is a limit where |
| 186 |
hardware is assumed still to be functional but approaching limit where |
| 187 |
it gets damaged. Recovery actions should be initiated. Zero can be passed |
| 188 |
to disable detection and value '1' indicates that detection should |
| 189 |
be enabled but limit setting can be omitted. Limit is given as microvolt |
| 190 |
offset from voltage set to regulator. |
| 191 |
|
| 192 |
regulator-uv-less-critical-window-ms: |
| 193 |
description: Specifies the time window (in milliseconds) following a |
| 194 |
critical under-voltage event during which the system can continue to |
| 195 |
operate safely while performing less critical operations. This property |
| 196 |
provides a defined duration before a more severe reaction to the |
| 197 |
under-voltage event is needed, allowing for certain non-urgent actions to |
| 198 |
be carried out in preparation for potential power loss. |
| 199 |
|
| 200 |
regulator-temp-protection-kelvin: |
| 201 |
description: Set over temperature protection limit. This is a limit where |
| 202 |
hardware performs emergency shutdown. Zero can be passed to disable |
| 203 |
protection and value '1' indicates that protection should be enabled but |
| 204 |
limit setting can be omitted. |
| 205 |
|
| 206 |
regulator-temp-error-kelvin: |
| 207 |
description: Set over temperature error limit. This is a limit where part of |
| 208 |
the hardware probably is malfunctional and damage prevention is requested |
| 209 |
Zero can be passed to disable error detection and value '1' indicates |
| 210 |
that detection should be enabled but limit setting can be omitted. |
| 211 |
|
| 212 |
regulator-temp-warn-kelvin: |
| 213 |
description: Set over temperature warning limit. This is a limit where |
| 214 |
hardware is assumed still to be functional but approaching limit where it |
| 215 |
gets damaged. Recovery actions should be initiated. Zero can be passed to |
| 216 |
disable detection and value '1' indicates that detection should |
| 217 |
be enabled but limit setting can be omitted. |
| 218 |
|
| 219 |
regulator-active-discharge: |
| 220 |
description: | |
| 221 |
tristate, enable/disable active discharge of regulators. The values are: |
| 222 |
0: Disable active discharge. |
| 223 |
1: Enable active discharge. |
| 224 |
Absence of this property will leave configuration to default. |
| 225 |
$ref: /schemas/types.yaml#/definitions/uint32 |
| 226 |
enum: [0, 1] |
| 227 |
|
| 228 |
regulator-coupled-with: |
| 229 |
description: Regulators with which the regulator is coupled. The linkage |
| 230 |
is 2-way - all coupled regulators should be linked with each other. |
| 231 |
A regulator should not be coupled with its supplier. |
| 232 |
$ref: /schemas/types.yaml#/definitions/phandle-array |
| 233 |
items: |
| 234 |
maxItems: 1 |
| 235 |
|
| 236 |
regulator-coupled-max-spread: |
| 237 |
description: Array of maximum spread between voltages of coupled regulators |
| 238 |
in microvolts, each value in the array relates to the corresponding |
| 239 |
couple specified by the regulator-coupled-with property. |
| 240 |
$ref: /schemas/types.yaml#/definitions/uint32-array |
| 241 |
|
| 242 |
regulator-max-step-microvolt: |
| 243 |
description: Maximum difference between current and target voltages |
| 244 |
that can be changed safely in a single step. |
| 245 |
|
| 246 |
patternProperties: |
| 247 |
".*-supply$": |
| 248 |
description: Input supply phandle(s) for this node |
| 249 |
|
| 250 |
"^regulator-state-(standby|mem|disk)$": |
| 251 |
type: object |
| 252 |
description: |
| 253 |
sub-nodes for regulator state in Standby, Suspend-to-RAM, and |
| 254 |
Suspend-to-DISK modes. Equivalent with standby, mem, and disk Linux |
| 255 |
sleep states. |
| 256 |
|
| 257 |
properties: |
| 258 |
regulator-on-in-suspend: |
| 259 |
description: regulator should be on in suspend state. |
| 260 |
type: boolean |
| 261 |
|
| 262 |
regulator-off-in-suspend: |
| 263 |
description: regulator should be off in suspend state. |
| 264 |
type: boolean |
| 265 |
|
| 266 |
regulator-suspend-min-microvolt: |
| 267 |
description: minimum voltage may be set in suspend state. |
| 268 |
|
| 269 |
regulator-suspend-max-microvolt: |
| 270 |
description: maximum voltage may be set in suspend state. |
| 271 |
|
| 272 |
regulator-suspend-microvolt: |
| 273 |
description: the default voltage which regulator would be set in |
| 274 |
suspend. This property is now deprecated, instead setting voltage |
| 275 |
for suspend mode via the API which regulator driver provides is |
| 276 |
recommended. |
| 277 |
deprecated: true |
| 278 |
|
| 279 |
regulator-changeable-in-suspend: |
| 280 |
description: whether the default voltage and the regulator on/off |
| 281 |
in suspend can be changed in runtime. |
| 282 |
type: boolean |
| 283 |
|
| 284 |
regulator-mode: |
| 285 |
description: operating mode in the given suspend state. The set |
| 286 |
of possible operating modes depends on the capabilities of every |
| 287 |
hardware so the valid modes are documented on each regulator device |
| 288 |
tree binding document. |
| 289 |
$ref: /schemas/types.yaml#/definitions/uint32 |
| 290 |
|
| 291 |
additionalProperties: false |
| 292 |
|
| 293 |
additionalProperties: true |
| 294 |
|
| 295 |
examples: |
| 296 |
- | |
| 297 |
xyzreg: regulator { |
| 298 |
regulator-min-microvolt = <1000000>; |
| 299 |
regulator-max-microvolt = <2500000>; |
| 300 |
regulator-always-on; |
| 301 |
vin-supply = <&vin>; |
| 302 |
|
| 303 |
regulator-state-mem { |
| 304 |
regulator-on-in-suspend; |
| 305 |
}; |
| 306 |
}; |
| 307 |
|
| 308 |
... |