Debian Codegraph @

Documentation/devicetree/bindings/power/supply/battery.yaml

raw
1 # SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
2 %YAML 1.2
3 ---
4 $id: http://devicetree.org/schemas/power/supply/battery.yaml#
5 $schema: http://devicetree.org/meta-schemas/core.yaml#
6
7 title: Battery Characteristics
8
9 maintainers:
10 - Sebastian Reichel <[email protected]>
11
12 description: |
13 The devicetree battery node provides static battery characteristics.
14 In smart batteries, these are typically stored in non-volatile memory
15 on a fuel gauge chip. The battery node should be used where there is
16 no appropriate non-volatile memory, or it is unprogrammed/incorrect.
17
18 Upstream dts files should not include battery nodes, unless the battery
19 represented cannot easily be replaced in the system by one of a
20 different type. This prevents unpredictable, potentially harmful,
21 behavior should a replacement that changes the battery type occur
22 without a corresponding update to the dtb.
23
24 Battery properties are named, where possible, for the corresponding elements
25 in enum power_supply_property, defined in include/linux/power_supply.h
26
27 Batteries must be referenced by chargers and/or fuel-gauges using a phandle.
28 The phandle's property should be named "monitored-battery".
29
30 properties:
31 compatible:
32 const: simple-battery
33
34 device-chemistry:
35 description: This describes the chemical technology of the battery.
36 oneOf:
37 - const: nickel-cadmium
38 - const: nickel-metal-hydride
39 - const: lithium-ion
40 description: This is a blanket type for all lithium-ion batteries,
41 including those below. If possible, a precise compatible string
42 from below should be used, but sometimes it is unknown which specific
43 lithium ion battery is employed and this wide compatible can be used.
44 - const: lithium-ion-polymer
45 - const: lithium-ion-iron-phosphate
46 - const: lithium-ion-manganese-oxide
47
48 over-voltage-threshold-microvolt:
49 description: battery over-voltage limit
50
51 re-charge-voltage-microvolt:
52 description: limit to automatically start charging again
53
54 voltage-min-design-microvolt:
55 description: drained battery voltage
56
57 voltage-max-design-microvolt:
58 description: fully charged battery voltage
59
60 energy-full-design-microwatt-hours:
61 description: battery design energy
62
63 charge-full-design-microamp-hours:
64 description: battery design capacity
65
66 trickle-charge-current-microamp:
67 description: current for trickle-charge phase.
68 Please note that the trickle-charging here, refers "wake-up" or
69 "pre-pre" -charging, for very empty batteries. Similar term is also
70 used for "maintenance" or "top-off" -charging of batteries (like
71 NiMh bq24400) - that is different and not controlled by this
72 property.
73
74 tricklecharge-upper-limit-microvolt:
75 description: limit when to change to precharge from trickle charge
76 Trickle-charging here refers "wake-up" or "pre-pre" -charging.
77
78 precharge-current-microamp:
79 description: current for pre-charge phase
80
81 precharge-upper-limit-microvolt:
82 description: limit when to change to constant charging
83
84 charge-term-current-microamp:
85 description: current for charge termination phase
86
87 constant-charge-current-max-microamp:
88 description: maximum constant input current
89
90 constant-charge-voltage-max-microvolt:
91 description: maximum constant input voltage
92
93 factory-internal-resistance-micro-ohms:
94 description: battery factory internal resistance
95
96 resistance-temp-table:
97 $ref: /schemas/types.yaml#/definitions/uint32-matrix
98 items:
99 items:
100 - description: the temperature in degree Celsius
101 - description: battery internal resistance percent
102 description: |
103 A table providing the temperature in degree Celsius
104 and corresponding battery internal resistance percent, which is used to
105 look up the resistance percent according to current temperature to get an
106 accurate batterty internal resistance in different temperatures.
107
108 ocv-capacity-celsius:
109 description: |
110 An array containing the temperature in degree Celsius,
111 for each of the battery capacity lookup table.
112
113 operating-range-celsius:
114 description: operating temperature range of a battery
115 items:
116 - description: minimum temperature at which battery can operate
117 - description: maximum temperature at which battery can operate
118
119 ambient-celsius:
120 description: safe range of ambient temperature
121 items:
122 - description: alert when ambient temperature is lower than this value
123 - description: alert when ambient temperature is higher than this value
124
125 alert-celsius:
126 description: safe range of battery temperature
127 items:
128 - description: alert when battery temperature is lower than this value
129 - description: alert when battery temperature is higher than this value
130
131 # The volt-drop* -properties describe voltage-drop for a battery, described
132 # as VDROP in:
133 # https://patentimages.storage.googleapis.com/6c/f5/17/c1d901c220f6a9/US20150032394A1.pdf
134 volt-drop-thresh-microvolt:
135 description: Threshold for starting the VDR correction
136 maximum: 48000000
137
138 volt-drop-soc-bp:
139 description: Table of capacity values matching the values in VDR tables.
140 The value should be given as basis points, 1/100 of a percent.
141
142 volt-drop-temperatures-millicelsius:
143 description: An array containing the temperature in milli celsius, for each
144 of the VDR lookup table.
145
146 required:
147 - compatible
148
149 patternProperties:
150 '^ocv-capacity-table-[0-9]+$':
151 $ref: /schemas/types.yaml#/definitions/uint32-matrix
152 description: |
153 An array providing the open circuit voltage (OCV)
154 of the battery and corresponding battery capacity percent, which is used
155 to look up battery capacity according to current OCV value. And the open
156 circuit voltage unit is microvolt.
157 maxItems: 100
158 items:
159 items:
160 - description: open circuit voltage (OCV) in microvolts
161 - description: battery capacity percent
162 maximum: 100
163
164 '^volt-drop-[0-9]-microvolt':
165 description: Table of the voltage drop rate (VDR) values. Each entry in the
166 table should match a capacity value in the volt-drop-soc table.
167 Furthermore, the values should be obtained for the temperature given in
168 volt-drop-temperatures-millicelsius table at index matching the
169 number in this table's name.
170
171 additionalProperties: false
172
173 examples:
174 - |
175 power {
176 #address-cells = <1>;
177 #size-cells = <0>;
178
179 battery: battery {
180 compatible = "simple-battery";
181 over-voltage-threshold-microvolt = <4500000>;
182 re-charge-voltage-microvolt = <250000>;
183 voltage-min-design-microvolt = <3200000>;
184 voltage-max-design-microvolt = <4200000>;
185 energy-full-design-microwatt-hours = <5290000>;
186 charge-full-design-microamp-hours = <1430000>;
187 precharge-current-microamp = <256000>;
188 precharge-upper-limit-microvolt = <2500000>;
189 charge-term-current-microamp = <128000>;
190 constant-charge-current-max-microamp = <900000>;
191 constant-charge-voltage-max-microvolt = <4200000>;
192 factory-internal-resistance-micro-ohms = <250000>;
193 ocv-capacity-celsius = <(-10) 0 10>;
194 /* table for -10 degree Celsius */
195 ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>;
196 /* table for 0 degree Celsius */
197 ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>;
198 /* table for 10 degree Celsius */
199 ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>;
200 resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>;
201 operating-range-celsius = <(-30) 50>;
202 ambient-celsius = <(-5) 50>;
203 alert-celsius = <0 40>;
204 };
205
206 charger@11 {
207 reg = <0x11>;
208 monitored-battery = <&battery>;
209 };
210
211 fuel-gauge@22 {
212 reg = <0x22>;
213 monitored-battery = <&battery>;
214 };
215 };