| 1 |
Binding for Texas Instruments FAPLL clock. |
| 2 |
|
| 3 |
This binding uses the common clock binding[1]. It assumes a |
| 4 |
register-mapped FAPLL with usually two selectable input clocks |
| 5 |
(reference clock and bypass clock), and one or more child |
| 6 |
syntesizers. |
| 7 |
|
| 8 |
[1] Documentation/devicetree/bindings/clock/clock-bindings.txt |
| 9 |
|
| 10 |
Required properties: |
| 11 |
- compatible : shall be "ti,dm816-fapll-clock" |
| 12 |
- #clock-cells : from common clock binding; shall be set to 0. |
| 13 |
- clocks : link phandles of parent clocks (clk-ref and clk-bypass) |
| 14 |
- reg : address and length of the register set for controlling the FAPLL. |
| 15 |
|
| 16 |
Examples: |
| 17 |
main_fapll: main_fapll { |
| 18 |
#clock-cells = <1>; |
| 19 |
compatible = "ti,dm816-fapll-clock"; |
| 20 |
reg = <0x400 0x40>; |
| 21 |
clocks = <&sys_clkin_ck &sys_clkin_ck>; |
| 22 |
clock-indices = <1>, <2>, <3>, <4>, <5>, |
| 23 |
<6>, <7>; |
| 24 |
clock-output-names = "main_pll_clk1", |
| 25 |
"main_pll_clk2", |
| 26 |
"main_pll_clk3", |
| 27 |
"main_pll_clk4", |
| 28 |
"main_pll_clk5", |
| 29 |
"main_pll_clk6", |
| 30 |
"main_pll_clk7"; |
| 31 |
}; |