| 1 |
.. SPDX-License-Identifier: GPL-2.0 |
| 2 |
|
| 3 |
============================================================ |
| 4 |
Hardware-Feedback Interface for scheduling on Intel Hardware |
| 5 |
============================================================ |
| 6 |
|
| 7 |
Overview |
| 8 |
-------- |
| 9 |
|
| 10 |
Intel has described the Hardware Feedback Interface (HFI) in the Intel 64 and |
| 11 |
IA-32 Architectures Software Developer's Manual (Intel SDM) Volume 3 Section |
| 12 |
14.6 [1]_. |
| 13 |
|
| 14 |
The HFI gives the operating system a performance and energy efficiency |
| 15 |
capability data for each CPU in the system. Linux can use the information from |
| 16 |
the HFI to influence task placement decisions. |
| 17 |
|
| 18 |
The Hardware Feedback Interface |
| 19 |
------------------------------- |
| 20 |
|
| 21 |
The Hardware Feedback Interface provides to the operating system information |
| 22 |
about the performance and energy efficiency of each CPU in the system. Each |
| 23 |
capability is given as a unit-less quantity in the range [0-255]. Higher values |
| 24 |
indicate higher capability. Energy efficiency and performance are reported in |
| 25 |
separate capabilities. Even though on some systems these two metrics may be |
| 26 |
related, they are specified as independent capabilities in the Intel SDM. |
| 27 |
|
| 28 |
These capabilities may change at runtime as a result of changes in the |
| 29 |
operating conditions of the system or the action of external factors. The rate |
| 30 |
at which these capabilities are updated is specific to each processor model. On |
| 31 |
some models, capabilities are set at boot time and never change. On others, |
| 32 |
capabilities may change every tens of milliseconds. For instance, a remote |
| 33 |
mechanism may be used to lower Thermal Design Power. Such change can be |
| 34 |
reflected in the HFI. Likewise, if the system needs to be throttled due to |
| 35 |
excessive heat, the HFI may reflect reduced performance on specific CPUs. |
| 36 |
|
| 37 |
The kernel or a userspace policy daemon can use these capabilities to modify |
| 38 |
task placement decisions. For instance, if either the performance or energy |
| 39 |
capabilities of a given logical processor becomes zero, it is an indication that |
| 40 |
the hardware recommends to the operating system to not schedule any tasks on |
| 41 |
that processor for performance or energy efficiency reasons, respectively. |
| 42 |
|
| 43 |
Implementation details for Linux |
| 44 |
-------------------------------- |
| 45 |
|
| 46 |
The infrastructure to handle thermal event interrupts has two parts. In the |
| 47 |
Local Vector Table of a CPU's local APIC, there exists a register for the |
| 48 |
Thermal Monitor Register. This register controls how interrupts are delivered |
| 49 |
to a CPU when the thermal monitor generates and interrupt. Further details |
| 50 |
can be found in the Intel SDM Vol. 3 Section 10.5 [1]_. |
| 51 |
|
| 52 |
The thermal monitor may generate interrupts per CPU or per package. The HFI |
| 53 |
generates package-level interrupts. This monitor is configured and initialized |
| 54 |
via a set of machine-specific registers. Specifically, the HFI interrupt and |
| 55 |
status are controlled via designated bits in the IA32_PACKAGE_THERM_INTERRUPT |
| 56 |
and IA32_PACKAGE_THERM_STATUS registers, respectively. There exists one HFI |
| 57 |
table per package. Further details can be found in the Intel SDM Vol. 3 |
| 58 |
Section 14.9 [1]_. |
| 59 |
|
| 60 |
The hardware issues an HFI interrupt after updating the HFI table and is ready |
| 61 |
for the operating system to consume it. CPUs receive such interrupt via the |
| 62 |
thermal entry in the Local APIC's Local Vector Table. |
| 63 |
|
| 64 |
When servicing such interrupt, the HFI driver parses the updated table and |
| 65 |
relays the update to userspace using the thermal notification framework. Given |
| 66 |
that there may be many HFI updates every second, the updates relayed to |
| 67 |
userspace are throttled at a rate of CONFIG_HZ jiffies. |
| 68 |
|
| 69 |
References |
| 70 |
---------- |
| 71 |
|
| 72 |
.. [1] https://www.intel.com/sdm |