| 1 |
.. SPDX-License-Identifier: GPL-2.0 |
| 2 |
.. _imc: |
| 3 |
|
| 4 |
=================================== |
| 5 |
IMC (In-Memory Collection Counters) |
| 6 |
=================================== |
| 7 |
|
| 8 |
Anju T Sudhakar, 10 May 2019 |
| 9 |
|
| 10 |
.. contents:: |
| 11 |
:depth: 3 |
| 12 |
|
| 13 |
|
| 14 |
Basic overview |
| 15 |
============== |
| 16 |
|
| 17 |
IMC (In-Memory collection counters) is a hardware monitoring facility that |
| 18 |
collects large numbers of hardware performance events at Nest level (these are |
| 19 |
on-chip but off-core), Core level and Thread level. |
| 20 |
|
| 21 |
The Nest PMU counters are handled by a Nest IMC microcode which runs in the OCC |
| 22 |
(On-Chip Controller) complex. The microcode collects the counter data and moves |
| 23 |
the nest IMC counter data to memory. |
| 24 |
|
| 25 |
The Core and Thread IMC PMU counters are handled in the core. Core level PMU |
| 26 |
counters give us the IMC counters' data per core and thread level PMU counters |
| 27 |
give us the IMC counters' data per CPU thread. |
| 28 |
|
| 29 |
OPAL obtains the IMC PMU and supported events information from the IMC Catalog |
| 30 |
and passes on to the kernel via the device tree. The event's information |
| 31 |
contains: |
| 32 |
|
| 33 |
- Event name |
| 34 |
- Event Offset |
| 35 |
- Event description |
| 36 |
|
| 37 |
and possibly also: |
| 38 |
|
| 39 |
- Event scale |
| 40 |
- Event unit |
| 41 |
|
| 42 |
Some PMUs may have a common scale and unit values for all their supported |
| 43 |
events. For those cases, the scale and unit properties for those events must be |
| 44 |
inherited from the PMU. |
| 45 |
|
| 46 |
The event offset in the memory is where the counter data gets accumulated. |
| 47 |
|
| 48 |
IMC catalog is available at: |
| 49 |
https://github.com/open-power/ima-catalog |
| 50 |
|
| 51 |
The kernel discovers the IMC counters information in the device tree at the |
| 52 |
`imc-counters` device node which has a compatible field |
| 53 |
`ibm,opal-in-memory-counters`. From the device tree, the kernel parses the PMUs |
| 54 |
and their event's information and register the PMU and its attributes in the |
| 55 |
kernel. |
| 56 |
|
| 57 |
IMC example usage |
| 58 |
================= |
| 59 |
|
| 60 |
.. code-block:: sh |
| 61 |
|
| 62 |
# perf list |
| 63 |
[...] |
| 64 |
nest_mcs01/PM_MCS01_64B_RD_DISP_PORT01/ [Kernel PMU event] |
| 65 |
nest_mcs01/PM_MCS01_64B_RD_DISP_PORT23/ [Kernel PMU event] |
| 66 |
[...] |
| 67 |
core_imc/CPM_0THRD_NON_IDLE_PCYC/ [Kernel PMU event] |
| 68 |
core_imc/CPM_1THRD_NON_IDLE_INST/ [Kernel PMU event] |
| 69 |
[...] |
| 70 |
thread_imc/CPM_0THRD_NON_IDLE_PCYC/ [Kernel PMU event] |
| 71 |
thread_imc/CPM_1THRD_NON_IDLE_INST/ [Kernel PMU event] |
| 72 |
|
| 73 |
To see per chip data for nest_mcs0/PM_MCS_DOWN_128B_DATA_XFER_MC0/: |
| 74 |
|
| 75 |
.. code-block:: sh |
| 76 |
|
| 77 |
# ./perf stat -e "nest_mcs01/PM_MCS01_64B_WR_DISP_PORT01/" -a --per-socket |
| 78 |
|
| 79 |
To see non-idle instructions for core 0: |
| 80 |
|
| 81 |
.. code-block:: sh |
| 82 |
|
| 83 |
# ./perf stat -e "core_imc/CPM_NON_IDLE_INST/" -C 0 -I 1000 |
| 84 |
|
| 85 |
To see non-idle instructions for a "make": |
| 86 |
|
| 87 |
.. code-block:: sh |
| 88 |
|
| 89 |
# ./perf stat -e "thread_imc/CPM_NON_IDLE_PCYC/" make |
| 90 |
|
| 91 |
|
| 92 |
IMC Trace-mode |
| 93 |
=============== |
| 94 |
|
| 95 |
POWER9 supports two modes for IMC which are the Accumulation mode and Trace |
| 96 |
mode. In Accumulation mode, event counts are accumulated in system Memory. |
| 97 |
Hypervisor then reads the posted counts periodically or when requested. In IMC |
| 98 |
Trace mode, the 64 bit trace SCOM value is initialized with the event |
| 99 |
information. The CPMCxSEL and CPMC_LOAD in the trace SCOM, specifies the event |
| 100 |
to be monitored and the sampling duration. On each overflow in the CPMCxSEL, |
| 101 |
hardware snapshots the program counter along with event counts and writes into |
| 102 |
memory pointed by LDBAR. |
| 103 |
|
| 104 |
LDBAR is a 64 bit special purpose per thread register, it has bits to indicate |
| 105 |
whether hardware is configured for accumulation or trace mode. |
| 106 |
|
| 107 |
LDBAR Register Layout |
| 108 |
--------------------- |
| 109 |
|
| 110 |
+-------+----------------------+ |
| 111 |
| 0 | Enable/Disable | |
| 112 |
+-------+----------------------+ |
| 113 |
| 1 | 0: Accumulation Mode | |
| 114 |
| +----------------------+ |
| 115 |
| | 1: Trace Mode | |
| 116 |
+-------+----------------------+ |
| 117 |
| 2:3 | Reserved | |
| 118 |
+-------+----------------------+ |
| 119 |
| 4-6 | PB scope | |
| 120 |
+-------+----------------------+ |
| 121 |
| 7 | Reserved | |
| 122 |
+-------+----------------------+ |
| 123 |
| 8:50 | Counter Address | |
| 124 |
+-------+----------------------+ |
| 125 |
| 51:63 | Reserved | |
| 126 |
+-------+----------------------+ |
| 127 |
|
| 128 |
TRACE_IMC_SCOM bit representation |
| 129 |
--------------------------------- |
| 130 |
|
| 131 |
+-------+------------+ |
| 132 |
| 0:1 | SAMPSEL | |
| 133 |
+-------+------------+ |
| 134 |
| 2:33 | CPMC_LOAD | |
| 135 |
+-------+------------+ |
| 136 |
| 34:40 | CPMC1SEL | |
| 137 |
+-------+------------+ |
| 138 |
| 41:47 | CPMC2SEL | |
| 139 |
+-------+------------+ |
| 140 |
| 48:50 | BUFFERSIZE | |
| 141 |
+-------+------------+ |
| 142 |
| 51:63 | RESERVED | |
| 143 |
+-------+------------+ |
| 144 |
|
| 145 |
CPMC_LOAD contains the sampling duration. SAMPSEL and CPMCxSEL determines the |
| 146 |
event to count. BUFFERSIZE indicates the memory range. On each overflow, |
| 147 |
hardware snapshots the program counter along with event counts and updates the |
| 148 |
memory and reloads the CMPC_LOAD value for the next sampling duration. IMC |
| 149 |
hardware does not support exceptions, so it quietly wraps around if memory |
| 150 |
buffer reaches the end. |
| 151 |
|
| 152 |
*Currently the event monitored for trace-mode is fixed as cycle.* |
| 153 |
|
| 154 |
Trace IMC example usage |
| 155 |
======================= |
| 156 |
|
| 157 |
.. code-block:: sh |
| 158 |
|
| 159 |
# perf list |
| 160 |
[....] |
| 161 |
trace_imc/trace_cycles/ [Kernel PMU event] |
| 162 |
|
| 163 |
To record an application/process with trace-imc event: |
| 164 |
|
| 165 |
.. code-block:: sh |
| 166 |
|
| 167 |
# perf record -e trace_imc/trace_cycles/ yes > /dev/null |
| 168 |
[ perf record: Woken up 1 times to write data ] |
| 169 |
[ perf record: Captured and wrote 0.012 MB perf.data (21 samples) ] |
| 170 |
|
| 171 |
The `perf.data` generated, can be read using perf report. |
| 172 |
|
| 173 |
Benefits of using IMC trace-mode |
| 174 |
================================ |
| 175 |
|
| 176 |
PMI (Performance Monitoring Interrupts) interrupt handling is avoided, since IMC |
| 177 |
trace mode snapshots the program counter and updates to the memory. And this |
| 178 |
also provide a way for the operating system to do instruction sampling in real |
| 179 |
time without PMI processing overhead. |
| 180 |
|
| 181 |
Performance data using `perf top` with and without trace-imc event. |
| 182 |
|
| 183 |
PMI interrupts count when `perf top` command is executed without trace-imc event. |
| 184 |
|
| 185 |
.. code-block:: sh |
| 186 |
|
| 187 |
# grep PMI /proc/interrupts |
| 188 |
PMI: 0 0 0 0 Performance monitoring interrupts |
| 189 |
# ./perf top |
| 190 |
... |
| 191 |
# grep PMI /proc/interrupts |
| 192 |
PMI: 39735 8710 17338 17801 Performance monitoring interrupts |
| 193 |
# ./perf top -e trace_imc/trace_cycles/ |
| 194 |
... |
| 195 |
# grep PMI /proc/interrupts |
| 196 |
PMI: 39735 8710 17338 17801 Performance monitoring interrupts |
| 197 |
|
| 198 |
|
| 199 |
That is, the PMI interrupt counts do not increment when using the `trace_imc` event. |