Debian Codegraph @

test/mibs/LIBSMI-TEST-014-MIB

raw
1 LIBSMI-TEST-014-MIB DEFINITIONS ::= BEGIN
2
3 IMPORTS
4 MODULE-IDENTITY, OBJECT-TYPE, Integer32
5 FROM SNMPv2-SMI
6 MacAddress
7 FROM SNMPv2-TC
8 OBJECT-GROUP
9 FROM SNMPv2-CONF
10 testMib
11 FROM LIBSMI-TEST-MIB;
12
13 libsmiTest014Mib MODULE-IDENTITY
14 LAST-UPDATED "200109270000Z"
15 ORGANIZATION
16 "TU Braunschweig"
17 CONTACT-INFO
18 " Frank Strauss
19
20 Postal: TU Braunschweig
21 Muehlenpfordtstrasse 23
22 38106 Braunschweig
23 Germany
24
25 Phone: +49 531 391-3283
26 EMail: [email protected]
27 http://www.ibr.cs.tu-bs.de/~strauss/"
28 DESCRIPTION
29 "This MIB module contains one or more intentional errors,
30 and/or unusual contents. Its only purpose is to check
31 the abilities of MIB parsers to detect these circumstances.
32
33 This MIB module is orginally written in SMIv2 format.
34
35 This module checks for range normalization, thus there are
36 no errors expected for this module. However the parser might
37 complain about ranges not being in ascending order.
38
39 The libsmi parser is expected to report:
40 LIBSMI-TEST-014-MIB:102: warning: index of row `barEntry' can exceed OID size limit by 1 subidentifier(s)
41 LIBSMI-TEST-014-MIB:186: warning: index of row `barImpliedEntry' can exceed OID size limit by 1 subidentifier(s)
42 LIBSMI-TEST-014-MIB:251: index element `fooStringName' of row `fooStringEntry' must have a size restriction
43 LIBSMI-TEST-014-MIB:230: warning: index of row `fooStringEntry' can exceed OID size limit by 65427 subidentifier(s)
44 LIBSMI-TEST-014-MIB:294: index element `fooOidName' of row `fooOidEntry' should but cannot have a size restriction
45 LIBSMI-TEST-014-MIB:273: warning: index of row `fooOidEntry' can exceed OID size limit by 20 subidentifier(s)
46 LIBSMI-TEST-014-MIB:309: warning: current group `fooOidBarGroup' is not referenced in this module
47 "
48 REVISION "200109270000Z"
49 DESCRIPTION
50 "Initial Revision."
51 ::= { testMib 14 }
52
53 fooTable OBJECT-TYPE
54 SYNTAX SEQUENCE OF FooEntry
55 MAX-ACCESS not-accessible
56 STATUS current
57 DESCRIPTION "..."
58 ::= { libsmiTest014Mib 1 }
59
60 fooEntry OBJECT-TYPE
61 SYNTAX FooEntry
62 MAX-ACCESS not-accessible
63 STATUS current
64 DESCRIPTION "..."
65 INDEX { fooAddr, fooName }
66 ::= { fooTable 1 }
67
68 FooEntry ::= SEQUENCE {
69 fooAddr MacAddress,
70 fooName OCTET STRING,
71 fooData Integer32
72 }
73
74 fooAddr OBJECT-TYPE
75 SYNTAX MacAddress
76 MAX-ACCESS not-accessible
77 STATUS current
78 DESCRIPTION "..."
79 ::= { fooEntry 1 }
80
81 fooName OBJECT-TYPE
82 SYNTAX OCTET STRING (SIZE(0..108))
83 MAX-ACCESS not-accessible
84 STATUS current
85 DESCRIPTION "..."
86 ::= { fooEntry 2 }
87
88 fooData OBJECT-TYPE
89 SYNTAX Integer32
90 MAX-ACCESS read-only
91 STATUS current
92 DESCRIPTION "..."
93 ::= { fooEntry 3 }
94
95 barTable OBJECT-TYPE
96 SYNTAX SEQUENCE OF BarEntry
97 MAX-ACCESS not-accessible
98 STATUS current
99 DESCRIPTION "..."
100 ::= { libsmiTest014Mib 2 }
101
102 barEntry OBJECT-TYPE
103 SYNTAX BarEntry
104 MAX-ACCESS not-accessible
105 STATUS current
106 DESCRIPTION "..."
107 INDEX { barAddr, barName }
108 ::= { barTable 1 }
109
110 BarEntry ::= SEQUENCE {
111 barAddr MacAddress,
112 barName OCTET STRING,
113 barData Integer32
114 }
115
116 barAddr OBJECT-TYPE
117 SYNTAX MacAddress
118 MAX-ACCESS not-accessible
119 STATUS current
120 DESCRIPTION "..."
121 ::= { barEntry 1 }
122
123 barName OBJECT-TYPE
124 SYNTAX OCTET STRING (SIZE(0..109))
125 MAX-ACCESS not-accessible
126 STATUS current
127 DESCRIPTION "..."
128 ::= { barEntry 2 }
129
130 barData OBJECT-TYPE
131 SYNTAX Integer32
132 MAX-ACCESS read-only
133 STATUS current
134 DESCRIPTION "..."
135 ::= { barEntry 3 }
136
137 fooImpliedTable OBJECT-TYPE
138 SYNTAX SEQUENCE OF FooImpliedEntry
139 MAX-ACCESS not-accessible
140 STATUS current
141 DESCRIPTION "..."
142 ::= { libsmiTest014Mib 3 }
143
144 fooImpliedEntry OBJECT-TYPE
145 SYNTAX FooImpliedEntry
146 MAX-ACCESS not-accessible
147 STATUS current
148 DESCRIPTION "..."
149 INDEX { fooImpliedAddr, IMPLIED fooImpliedName }
150 ::= { fooImpliedTable 1 }
151
152 FooImpliedEntry ::= SEQUENCE {
153 fooImpliedAddr MacAddress,
154 fooImpliedName OCTET STRING,
155 fooImpliedData Integer32
156 }
157
158 fooImpliedAddr OBJECT-TYPE
159 SYNTAX MacAddress
160 MAX-ACCESS not-accessible
161 STATUS current
162 DESCRIPTION "..."
163 ::= { fooImpliedEntry 1 }
164
165 fooImpliedName OBJECT-TYPE
166 SYNTAX OCTET STRING (SIZE(0..109))
167 MAX-ACCESS not-accessible
168 STATUS current
169 DESCRIPTION "..."
170 ::= { fooImpliedEntry 2 }
171
172 fooImpliedData OBJECT-TYPE
173 SYNTAX Integer32
174 MAX-ACCESS read-only
175 STATUS current
176 DESCRIPTION "..."
177 ::= { fooImpliedEntry 3 }
178
179 barImpliedTable OBJECT-TYPE
180 SYNTAX SEQUENCE OF BarImpliedEntry
181 MAX-ACCESS not-accessible
182 STATUS current
183 DESCRIPTION "..."
184 ::= { libsmiTest014Mib 4 }
185
186 barImpliedEntry OBJECT-TYPE
187 SYNTAX BarImpliedEntry
188 MAX-ACCESS not-accessible
189 STATUS current
190 DESCRIPTION "..."
191 INDEX { barImpliedAddr, IMPLIED barImpliedName }
192 ::= { barImpliedTable 1 }
193
194 BarImpliedEntry ::= SEQUENCE {
195 barImpliedAddr MacAddress,
196 barImpliedName OCTET STRING,
197 barImpliedData Integer32
198 }
199
200 barImpliedAddr OBJECT-TYPE
201 SYNTAX MacAddress
202 MAX-ACCESS not-accessible
203 STATUS current
204 DESCRIPTION "..."
205 ::= { barImpliedEntry 1 }
206
207 barImpliedName OBJECT-TYPE
208 SYNTAX OCTET STRING (SIZE(0..110))
209 MAX-ACCESS not-accessible
210 STATUS current
211 DESCRIPTION "..."
212 ::= { barImpliedEntry 2 }
213
214 barImpliedData OBJECT-TYPE
215 SYNTAX Integer32
216 MAX-ACCESS read-only
217 STATUS current
218 DESCRIPTION "..."
219 ::= { barImpliedEntry 3 }
220
221
222
223 fooStringTable OBJECT-TYPE
224 SYNTAX SEQUENCE OF FooStringEntry
225 MAX-ACCESS not-accessible
226 STATUS current
227 DESCRIPTION "..."
228 ::= { libsmiTest014Mib 5 }
229
230 fooStringEntry OBJECT-TYPE
231 SYNTAX FooStringEntry
232 MAX-ACCESS not-accessible
233 STATUS current
234 DESCRIPTION "..."
235 INDEX { fooStringAddr, fooStringName }
236 ::= { fooStringTable 1 }
237
238 FooStringEntry ::= SEQUENCE {
239 fooStringAddr MacAddress,
240 fooStringName OCTET STRING,
241 fooStringData Integer32
242 }
243
244 fooStringAddr OBJECT-TYPE
245 SYNTAX MacAddress
246 MAX-ACCESS not-accessible
247 STATUS current
248 DESCRIPTION "..."
249 ::= { fooStringEntry 1 }
250
251 fooStringName OBJECT-TYPE
252 SYNTAX OCTET STRING
253 MAX-ACCESS not-accessible
254 STATUS current
255 DESCRIPTION "..."
256 ::= { fooStringEntry 2 }
257
258 fooStringData OBJECT-TYPE
259 SYNTAX Integer32
260 MAX-ACCESS read-only
261 STATUS current
262 DESCRIPTION "..."
263 ::= { fooStringEntry 3 }
264
265
266 fooOidTable OBJECT-TYPE
267 SYNTAX SEQUENCE OF FooOidEntry
268 MAX-ACCESS not-accessible
269 STATUS current
270 DESCRIPTION "..."
271 ::= { libsmiTest014Mib 6 }
272
273 fooOidEntry OBJECT-TYPE
274 SYNTAX FooOidEntry
275 MAX-ACCESS not-accessible
276 STATUS current
277 DESCRIPTION "..."
278 INDEX { fooOidAddr, fooOidName }
279 ::= { fooOidTable 1 }
280
281 FooOidEntry ::= SEQUENCE {
282 fooOidAddr MacAddress,
283 fooOidName OBJECT IDENTIFIER,
284 fooOidData Integer32
285 }
286
287 fooOidAddr OBJECT-TYPE
288 SYNTAX MacAddress
289 MAX-ACCESS not-accessible
290 STATUS current
291 DESCRIPTION "..."
292 ::= { fooOidEntry 1 }
293
294 fooOidName OBJECT-TYPE
295 SYNTAX OBJECT IDENTIFIER
296 MAX-ACCESS not-accessible
297 STATUS current
298 DESCRIPTION "..."
299 ::= { fooOidEntry 2 }
300
301 fooOidData OBJECT-TYPE
302 SYNTAX Integer32
303 MAX-ACCESS read-only
304 STATUS current
305 DESCRIPTION "..."
306 ::= { fooOidEntry 3 }
307
308
309 fooOidBarGroup OBJECT-GROUP
310 OBJECTS { fooData, barData, fooImpliedData, barImpliedData,
311 fooStringData, fooOidData }
312 STATUS current
313 DESCRIPTION
314 "junk"