| 1 |
-- |
| 2 |
-- This SMIv1 module has been generated by smidump 0.4.5. Do not edit. |
| 3 |
-- |
| 4 |
|
| 5 |
IF-MIB DEFINITIONS ::= BEGIN |
| 6 |
|
| 7 |
IMPORTS |
| 8 |
IANAifType |
| 9 |
FROM IANAifType-MIB |
| 10 |
OBJECT-TYPE |
| 11 |
FROM RFC-1212 |
| 12 |
TRAP-TYPE |
| 13 |
FROM RFC-1215 |
| 14 |
Counter, Gauge, TimeTicks |
| 15 |
FROM RFC1155-SMI |
| 16 |
mib-2 |
| 17 |
FROM RFC1213-MIB |
| 18 |
snmpTraps |
| 19 |
FROM SNMPv2-MIB |
| 20 |
AutonomousType, DisplayString, PhysAddress, RowStatus, TestAndIncr, |
| 21 |
TimeStamp, TruthValue |
| 22 |
FROM SNMPv2-TC; |
| 23 |
|
| 24 |
ifMIB OBJECT IDENTIFIER |
| 25 |
::= { mib-2 31 } |
| 26 |
|
| 27 |
-- ifMIB MODULE-IDENTITY |
| 28 |
-- LAST-UPDATED "200006140000Z" |
| 29 |
-- ORGANIZATION |
| 30 |
-- "IETF Interfaces MIB Working Group" |
| 31 |
-- CONTACT-INFO |
| 32 |
-- " Keith McCloghrie |
| 33 |
-- Cisco Systems, Inc. |
| 34 |
-- 170 West Tasman Drive |
| 35 |
-- San Jose, CA 95134-1706 |
| 36 |
-- US |
| 37 |
-- |
| 38 |
-- 408-526-5260 |
| 39 |
-- [email protected]" |
| 40 |
-- DESCRIPTION |
| 41 |
-- "The MIB module to describe generic objects for network |
| 42 |
-- interface sub-layers. This MIB is an updated version of |
| 43 |
-- MIB-II's ifTable, and incorporates the extensions defined in |
| 44 |
-- RFC 1229." |
| 45 |
-- REVISION "200006140000Z" |
| 46 |
-- DESCRIPTION |
| 47 |
-- "Clarifications agreed upon by the Interfaces MIB WG, and |
| 48 |
-- published as RFC 2863." |
| 49 |
-- REVISION "199602282155Z" |
| 50 |
-- DESCRIPTION |
| 51 |
-- "Revisions made by the Interfaces MIB WG, and published in |
| 52 |
-- RFC 2233." |
| 53 |
-- REVISION "199311082155Z" |
| 54 |
-- DESCRIPTION |
| 55 |
-- "Initial revision, published as part of RFC 1573." |
| 56 |
-- ::= { mib-2 31 } |
| 57 |
|
| 58 |
|
| 59 |
OwnerString ::= |
| 60 |
OCTET STRING (SIZE(0..255)) |
| 61 |
|
| 62 |
-- OwnerString ::= TEXTUAL-CONVENTION |
| 63 |
-- DISPLAY-HINT "255a" |
| 64 |
-- STATUS deprecated |
| 65 |
-- DESCRIPTION |
| 66 |
-- "This data type is used to model an administratively |
| 67 |
-- assigned name of the owner of a resource. This information |
| 68 |
-- is taken from the NVT ASCII character set. It is suggested |
| 69 |
-- that this name contain one or more of the following: ASCII |
| 70 |
-- form of the manager station's transport address, management |
| 71 |
-- station name (e.g., domain name), network management |
| 72 |
-- personnel's name, location, or phone number. In some cases |
| 73 |
-- the agent itself will be the owner of an entry. In these |
| 74 |
-- cases, this string shall be set to a string starting with |
| 75 |
-- 'agent'." |
| 76 |
-- SYNTAX OCTET STRING (SIZE(0..255)) |
| 77 |
|
| 78 |
InterfaceIndex ::= |
| 79 |
INTEGER (1..2147483647) |
| 80 |
|
| 81 |
-- InterfaceIndex ::= TEXTUAL-CONVENTION |
| 82 |
-- DISPLAY-HINT "d" |
| 83 |
-- STATUS mandatory |
| 84 |
-- DESCRIPTION |
| 85 |
-- "A unique value, greater than zero, for each interface or |
| 86 |
-- interface sub-layer in the managed system. It is |
| 87 |
-- recommended that values are assigned contiguously starting |
| 88 |
-- from 1. The value for each interface sub-layer must remain |
| 89 |
-- constant at least from one re-initialization of the entity's |
| 90 |
-- network management system to the next re-initialization." |
| 91 |
-- SYNTAX INTEGER (1..2147483647) |
| 92 |
|
| 93 |
InterfaceIndexOrZero ::= |
| 94 |
INTEGER (0..2147483647) |
| 95 |
|
| 96 |
-- InterfaceIndexOrZero ::= TEXTUAL-CONVENTION |
| 97 |
-- DISPLAY-HINT "d" |
| 98 |
-- STATUS mandatory |
| 99 |
-- DESCRIPTION |
| 100 |
-- "This textual convention is an extension of the |
| 101 |
-- InterfaceIndex convention. The latter defines a greater |
| 102 |
-- than zero value used to identify an interface or interface |
| 103 |
-- sub-layer in the managed system. This extension permits the |
| 104 |
-- additional value of zero. the value zero is object-specific |
| 105 |
-- and must therefore be defined as part of the description of |
| 106 |
-- any object which uses this syntax. Examples of the usage of |
| 107 |
-- zero might include situations where interface was unknown, |
| 108 |
-- or when none or all interfaces need to be referenced." |
| 109 |
-- SYNTAX INTEGER (0..2147483647) |
| 110 |
|
| 111 |
interfaces OBJECT IDENTIFIER |
| 112 |
::= { mib-2 2 } |
| 113 |
|
| 114 |
ifNumber OBJECT-TYPE |
| 115 |
SYNTAX INTEGER |
| 116 |
ACCESS read-only |
| 117 |
STATUS mandatory |
| 118 |
DESCRIPTION |
| 119 |
"The number of network interfaces (regardless of their |
| 120 |
current state) present on this system." |
| 121 |
::= { interfaces 1 } |
| 122 |
|
| 123 |
ifTable OBJECT-TYPE |
| 124 |
SYNTAX SEQUENCE OF IfEntry |
| 125 |
ACCESS not-accessible |
| 126 |
STATUS mandatory |
| 127 |
DESCRIPTION |
| 128 |
"A list of interface entries. The number of entries is |
| 129 |
given by the value of ifNumber." |
| 130 |
::= { interfaces 2 } |
| 131 |
|
| 132 |
ifEntry OBJECT-TYPE |
| 133 |
SYNTAX IfEntry |
| 134 |
ACCESS not-accessible |
| 135 |
STATUS mandatory |
| 136 |
DESCRIPTION |
| 137 |
"An entry containing management information applicable to a |
| 138 |
particular interface." |
| 139 |
INDEX { ifIndex } |
| 140 |
::= { ifTable 1 } |
| 141 |
|
| 142 |
IfEntry ::= SEQUENCE { |
| 143 |
ifIndex InterfaceIndex, |
| 144 |
ifDescr DisplayString, |
| 145 |
ifType IANAifType, |
| 146 |
ifMtu INTEGER, |
| 147 |
ifSpeed Gauge, |
| 148 |
ifPhysAddress PhysAddress, |
| 149 |
ifAdminStatus INTEGER, |
| 150 |
ifOperStatus INTEGER, |
| 151 |
ifLastChange TimeTicks, |
| 152 |
ifInOctets Counter, |
| 153 |
ifInUcastPkts Counter, |
| 154 |
ifInNUcastPkts Counter, |
| 155 |
ifInDiscards Counter, |
| 156 |
ifInErrors Counter, |
| 157 |
ifInUnknownProtos Counter, |
| 158 |
ifOutOctets Counter, |
| 159 |
ifOutUcastPkts Counter, |
| 160 |
ifOutNUcastPkts Counter, |
| 161 |
ifOutDiscards Counter, |
| 162 |
ifOutErrors Counter, |
| 163 |
ifOutQLen Gauge, |
| 164 |
ifSpecific OBJECT IDENTIFIER |
| 165 |
} |
| 166 |
|
| 167 |
ifIndex OBJECT-TYPE |
| 168 |
SYNTAX InterfaceIndex |
| 169 |
ACCESS read-only |
| 170 |
STATUS mandatory |
| 171 |
DESCRIPTION |
| 172 |
"A unique value, greater than zero, for each interface. It |
| 173 |
is recommended that values are assigned contiguously |
| 174 |
starting from 1. The value for each interface sub-layer |
| 175 |
must remain constant at least from one re-initialization of |
| 176 |
the entity's network management system to the next re- |
| 177 |
initialization." |
| 178 |
::= { ifEntry 1 } |
| 179 |
|
| 180 |
ifDescr OBJECT-TYPE |
| 181 |
SYNTAX DisplayString (SIZE(0..255)) |
| 182 |
ACCESS read-only |
| 183 |
STATUS mandatory |
| 184 |
DESCRIPTION |
| 185 |
"A textual string containing information about the |
| 186 |
interface. This string should include the name of the |
| 187 |
manufacturer, the product name and the version of the |
| 188 |
interface hardware/software." |
| 189 |
::= { ifEntry 2 } |
| 190 |
|
| 191 |
ifType OBJECT-TYPE |
| 192 |
SYNTAX IANAifType |
| 193 |
ACCESS read-only |
| 194 |
STATUS mandatory |
| 195 |
DESCRIPTION |
| 196 |
"The type of interface. Additional values for ifType are |
| 197 |
assigned by the Internet Assigned Numbers Authority (IANA), |
| 198 |
through updating the syntax of the IANAifType textual |
| 199 |
convention." |
| 200 |
::= { ifEntry 3 } |
| 201 |
|
| 202 |
ifMtu OBJECT-TYPE |
| 203 |
SYNTAX INTEGER |
| 204 |
ACCESS read-only |
| 205 |
STATUS mandatory |
| 206 |
DESCRIPTION |
| 207 |
"The size of the largest packet which can be sent/received |
| 208 |
on the interface, specified in octets. For interfaces that |
| 209 |
are used for transmitting network datagrams, this is the |
| 210 |
size of the largest network datagram that can be sent on the |
| 211 |
interface." |
| 212 |
::= { ifEntry 4 } |
| 213 |
|
| 214 |
ifSpeed OBJECT-TYPE |
| 215 |
SYNTAX Gauge |
| 216 |
ACCESS read-only |
| 217 |
STATUS mandatory |
| 218 |
DESCRIPTION |
| 219 |
"An estimate of the interface's current bandwidth in bits |
| 220 |
per second. For interfaces which do not vary in bandwidth |
| 221 |
or for those where no accurate estimation can be made, this |
| 222 |
object should contain the nominal bandwidth. If the |
| 223 |
bandwidth of the interface is greater than the maximum value |
| 224 |
reportable by this object then this object should report its |
| 225 |
maximum value (4,294,967,295) and ifHighSpeed must be used |
| 226 |
to report the interace's speed. For a sub-layer which has |
| 227 |
no concept of bandwidth, this object should be zero." |
| 228 |
::= { ifEntry 5 } |
| 229 |
|
| 230 |
ifPhysAddress OBJECT-TYPE |
| 231 |
SYNTAX PhysAddress |
| 232 |
ACCESS read-only |
| 233 |
STATUS mandatory |
| 234 |
DESCRIPTION |
| 235 |
"The interface's address at its protocol sub-layer. For |
| 236 |
example, for an 802.x interface, this object normally |
| 237 |
contains a MAC address. The interface's media-specific MIB |
| 238 |
must define the bit and byte ordering and the format of the |
| 239 |
value of this object. For interfaces which do not have such |
| 240 |
an address (e.g., a serial line), this object should contain |
| 241 |
an octet string of zero length." |
| 242 |
::= { ifEntry 6 } |
| 243 |
|
| 244 |
ifAdminStatus OBJECT-TYPE |
| 245 |
SYNTAX INTEGER { up(1), down(2), testing(3) } |
| 246 |
ACCESS read-write |
| 247 |
STATUS mandatory |
| 248 |
DESCRIPTION |
| 249 |
"The desired state of the interface. The testing(3) state |
| 250 |
indicates that no operational packets can be passed. When a |
| 251 |
managed system initializes, all interfaces start with |
| 252 |
ifAdminStatus in the down(2) state. As a result of either |
| 253 |
explicit management action or per configuration information |
| 254 |
retained by the managed system, ifAdminStatus is then |
| 255 |
changed to either the up(1) or testing(3) states (or remains |
| 256 |
in the down(2) state)." |
| 257 |
::= { ifEntry 7 } |
| 258 |
|
| 259 |
ifOperStatus OBJECT-TYPE |
| 260 |
SYNTAX INTEGER { up(1), down(2), testing(3), unknown(4), |
| 261 |
dormant(5), notPresent(6), lowerLayerDown(7) } |
| 262 |
ACCESS read-only |
| 263 |
STATUS mandatory |
| 264 |
DESCRIPTION |
| 265 |
"The current operational state of the interface. The |
| 266 |
testing(3) state indicates that no operational packets can |
| 267 |
be passed. If ifAdminStatus is down(2) then ifOperStatus |
| 268 |
should be down(2). If ifAdminStatus is changed to up(1) |
| 269 |
then ifOperStatus should change to up(1) if the interface is |
| 270 |
ready to transmit and receive network traffic; it should |
| 271 |
change to dormant(5) if the interface is waiting for |
| 272 |
external actions (such as a serial line waiting for an |
| 273 |
incoming connection); it should remain in the down(2) state |
| 274 |
if and only if there is a fault that prevents it from going |
| 275 |
to the up(1) state; it should remain in the notPresent(6) |
| 276 |
state if the interface has missing (typically, hardware) |
| 277 |
components." |
| 278 |
::= { ifEntry 8 } |
| 279 |
|
| 280 |
ifLastChange OBJECT-TYPE |
| 281 |
SYNTAX TimeTicks |
| 282 |
ACCESS read-only |
| 283 |
STATUS mandatory |
| 284 |
DESCRIPTION |
| 285 |
"The value of sysUpTime at the time the interface entered |
| 286 |
its current operational state. If the current state was |
| 287 |
entered prior to the last re-initialization of the local |
| 288 |
network management subsystem, then this object contains a |
| 289 |
zero value." |
| 290 |
::= { ifEntry 9 } |
| 291 |
|
| 292 |
ifInOctets OBJECT-TYPE |
| 293 |
SYNTAX Counter |
| 294 |
ACCESS read-only |
| 295 |
STATUS mandatory |
| 296 |
DESCRIPTION |
| 297 |
"The total number of octets received on the interface, |
| 298 |
|
| 299 |
|
| 300 |
including framing characters. |
| 301 |
|
| 302 |
Discontinuities in the value of this counter can occur at |
| 303 |
re-initialization of the management system, and at other |
| 304 |
times as indicated by the value of |
| 305 |
ifCounterDiscontinuityTime." |
| 306 |
::= { ifEntry 10 } |
| 307 |
|
| 308 |
ifInUcastPkts OBJECT-TYPE |
| 309 |
SYNTAX Counter |
| 310 |
ACCESS read-only |
| 311 |
STATUS mandatory |
| 312 |
DESCRIPTION |
| 313 |
"The number of packets, delivered by this sub-layer to a |
| 314 |
higher (sub-)layer, which were not addressed to a multicast |
| 315 |
or broadcast address at this sub-layer. |
| 316 |
|
| 317 |
Discontinuities in the value of this counter can occur at |
| 318 |
re-initialization of the management system, and at other |
| 319 |
times as indicated by the value of |
| 320 |
ifCounterDiscontinuityTime." |
| 321 |
::= { ifEntry 11 } |
| 322 |
|
| 323 |
ifInNUcastPkts OBJECT-TYPE |
| 324 |
SYNTAX Counter |
| 325 |
ACCESS read-only |
| 326 |
STATUS deprecated |
| 327 |
DESCRIPTION |
| 328 |
"The number of packets, delivered by this sub-layer to a |
| 329 |
higher (sub-)layer, which were addressed to a multicast or |
| 330 |
broadcast address at this sub-layer. |
| 331 |
|
| 332 |
Discontinuities in the value of this counter can occur at |
| 333 |
re-initialization of the management system, and at other |
| 334 |
times as indicated by the value of |
| 335 |
ifCounterDiscontinuityTime. |
| 336 |
|
| 337 |
This object is deprecated in favour of ifInMulticastPkts and |
| 338 |
ifInBroadcastPkts." |
| 339 |
::= { ifEntry 12 } |
| 340 |
|
| 341 |
ifInDiscards OBJECT-TYPE |
| 342 |
SYNTAX Counter |
| 343 |
ACCESS read-only |
| 344 |
STATUS mandatory |
| 345 |
DESCRIPTION |
| 346 |
"The number of inbound packets which were chosen to be |
| 347 |
discarded even though no errors had been detected to prevent |
| 348 |
|
| 349 |
|
| 350 |
their being deliverable to a higher-layer protocol. One |
| 351 |
possible reason for discarding such a packet could be to |
| 352 |
free up buffer space. |
| 353 |
|
| 354 |
Discontinuities in the value of this counter can occur at |
| 355 |
re-initialization of the management system, and at other |
| 356 |
times as indicated by the value of |
| 357 |
ifCounterDiscontinuityTime." |
| 358 |
::= { ifEntry 13 } |
| 359 |
|
| 360 |
ifInErrors OBJECT-TYPE |
| 361 |
SYNTAX Counter |
| 362 |
ACCESS read-only |
| 363 |
STATUS mandatory |
| 364 |
DESCRIPTION |
| 365 |
"For packet-oriented interfaces, the number of inbound |
| 366 |
packets that contained errors preventing them from being |
| 367 |
deliverable to a higher-layer protocol. For character- |
| 368 |
oriented or fixed-length interfaces, the number of inbound |
| 369 |
transmission units that contained errors preventing them |
| 370 |
from being deliverable to a higher-layer protocol. |
| 371 |
|
| 372 |
Discontinuities in the value of this counter can occur at |
| 373 |
re-initialization of the management system, and at other |
| 374 |
times as indicated by the value of |
| 375 |
ifCounterDiscontinuityTime." |
| 376 |
::= { ifEntry 14 } |
| 377 |
|
| 378 |
ifInUnknownProtos OBJECT-TYPE |
| 379 |
SYNTAX Counter |
| 380 |
ACCESS read-only |
| 381 |
STATUS mandatory |
| 382 |
DESCRIPTION |
| 383 |
"For packet-oriented interfaces, the number of packets |
| 384 |
received via the interface which were discarded because of |
| 385 |
an unknown or unsupported protocol. For character-oriented |
| 386 |
or fixed-length interfaces that support protocol |
| 387 |
multiplexing the number of transmission units received via |
| 388 |
the interface which were discarded because of an unknown or |
| 389 |
unsupported protocol. For any interface that does not |
| 390 |
support protocol multiplexing, this counter will always be |
| 391 |
0. |
| 392 |
|
| 393 |
Discontinuities in the value of this counter can occur at |
| 394 |
re-initialization of the management system, and at other |
| 395 |
times as indicated by the value of |
| 396 |
ifCounterDiscontinuityTime." |
| 397 |
::= { ifEntry 15 } |
| 398 |
|
| 399 |
ifOutOctets OBJECT-TYPE |
| 400 |
SYNTAX Counter |
| 401 |
ACCESS read-only |
| 402 |
STATUS mandatory |
| 403 |
DESCRIPTION |
| 404 |
"The total number of octets transmitted out of the |
| 405 |
interface, including framing characters. |
| 406 |
|
| 407 |
Discontinuities in the value of this counter can occur at |
| 408 |
re-initialization of the management system, and at other |
| 409 |
times as indicated by the value of |
| 410 |
ifCounterDiscontinuityTime." |
| 411 |
::= { ifEntry 16 } |
| 412 |
|
| 413 |
ifOutUcastPkts OBJECT-TYPE |
| 414 |
SYNTAX Counter |
| 415 |
ACCESS read-only |
| 416 |
STATUS mandatory |
| 417 |
DESCRIPTION |
| 418 |
"The total number of packets that higher-level protocols |
| 419 |
requested be transmitted, and which were not addressed to a |
| 420 |
multicast or broadcast address at this sub-layer, including |
| 421 |
those that were discarded or not sent. |
| 422 |
|
| 423 |
Discontinuities in the value of this counter can occur at |
| 424 |
re-initialization of the management system, and at other |
| 425 |
times as indicated by the value of |
| 426 |
ifCounterDiscontinuityTime." |
| 427 |
::= { ifEntry 17 } |
| 428 |
|
| 429 |
ifOutNUcastPkts OBJECT-TYPE |
| 430 |
SYNTAX Counter |
| 431 |
ACCESS read-only |
| 432 |
STATUS deprecated |
| 433 |
DESCRIPTION |
| 434 |
"The total number of packets that higher-level protocols |
| 435 |
requested be transmitted, and which were addressed to a |
| 436 |
multicast or broadcast address at this sub-layer, including |
| 437 |
those that were discarded or not sent. |
| 438 |
|
| 439 |
Discontinuities in the value of this counter can occur at |
| 440 |
re-initialization of the management system, and at other |
| 441 |
times as indicated by the value of |
| 442 |
ifCounterDiscontinuityTime. |
| 443 |
|
| 444 |
This object is deprecated in favour of ifOutMulticastPkts |
| 445 |
and ifOutBroadcastPkts." |
| 446 |
::= { ifEntry 18 } |
| 447 |
|
| 448 |
ifOutDiscards OBJECT-TYPE |
| 449 |
SYNTAX Counter |
| 450 |
ACCESS read-only |
| 451 |
STATUS mandatory |
| 452 |
DESCRIPTION |
| 453 |
"The number of outbound packets which were chosen to be |
| 454 |
discarded even though no errors had been detected to prevent |
| 455 |
their being transmitted. One possible reason for discarding |
| 456 |
such a packet could be to free up buffer space. |
| 457 |
|
| 458 |
Discontinuities in the value of this counter can occur at |
| 459 |
re-initialization of the management system, and at other |
| 460 |
times as indicated by the value of |
| 461 |
ifCounterDiscontinuityTime." |
| 462 |
::= { ifEntry 19 } |
| 463 |
|
| 464 |
ifOutErrors OBJECT-TYPE |
| 465 |
SYNTAX Counter |
| 466 |
ACCESS read-only |
| 467 |
STATUS mandatory |
| 468 |
DESCRIPTION |
| 469 |
"For packet-oriented interfaces, the number of outbound |
| 470 |
packets that could not be transmitted because of errors. |
| 471 |
For character-oriented or fixed-length interfaces, the |
| 472 |
number of outbound transmission units that could not be |
| 473 |
transmitted because of errors. |
| 474 |
|
| 475 |
Discontinuities in the value of this counter can occur at |
| 476 |
re-initialization of the management system, and at other |
| 477 |
times as indicated by the value of |
| 478 |
ifCounterDiscontinuityTime." |
| 479 |
::= { ifEntry 20 } |
| 480 |
|
| 481 |
ifOutQLen OBJECT-TYPE |
| 482 |
SYNTAX Gauge |
| 483 |
ACCESS read-only |
| 484 |
STATUS deprecated |
| 485 |
DESCRIPTION |
| 486 |
"The length of the output packet queue (in packets)." |
| 487 |
::= { ifEntry 21 } |
| 488 |
|
| 489 |
ifSpecific OBJECT-TYPE |
| 490 |
SYNTAX OBJECT IDENTIFIER |
| 491 |
ACCESS read-only |
| 492 |
STATUS deprecated |
| 493 |
DESCRIPTION |
| 494 |
"A reference to MIB definitions specific to the particular |
| 495 |
media being used to realize the interface. It is |
| 496 |
|
| 497 |
|
| 498 |
recommended that this value point to an instance of a MIB |
| 499 |
object in the media-specific MIB, i.e., that this object |
| 500 |
have the semantics associated with the InstancePointer |
| 501 |
textual convention defined in RFC 2579. In fact, it is |
| 502 |
recommended that the media-specific MIB specify what value |
| 503 |
ifSpecific should/can take for values of ifType. If no MIB |
| 504 |
definitions specific to the particular media are available, |
| 505 |
the value should be set to the OBJECT IDENTIFIER { 0 0 }." |
| 506 |
::= { ifEntry 22 } |
| 507 |
|
| 508 |
ifMIBObjects OBJECT IDENTIFIER |
| 509 |
::= { ifMIB 1 } |
| 510 |
|
| 511 |
ifXTable OBJECT-TYPE |
| 512 |
SYNTAX SEQUENCE OF IfXEntry |
| 513 |
ACCESS not-accessible |
| 514 |
STATUS mandatory |
| 515 |
DESCRIPTION |
| 516 |
"A list of interface entries. The number of entries is |
| 517 |
given by the value of ifNumber. This table contains |
| 518 |
additional objects for the interface table." |
| 519 |
::= { ifMIBObjects 1 } |
| 520 |
|
| 521 |
ifXEntry OBJECT-TYPE |
| 522 |
SYNTAX IfXEntry |
| 523 |
ACCESS not-accessible |
| 524 |
STATUS mandatory |
| 525 |
DESCRIPTION |
| 526 |
"An entry containing additional management information |
| 527 |
applicable to a particular interface." |
| 528 |
INDEX { ifIndex } |
| 529 |
-- AUGMENTS { ifEntry } |
| 530 |
::= { ifXTable 1 } |
| 531 |
|
| 532 |
IfXEntry ::= SEQUENCE { |
| 533 |
ifName DisplayString, |
| 534 |
ifInMulticastPkts Counter, |
| 535 |
ifInBroadcastPkts Counter, |
| 536 |
ifOutMulticastPkts Counter, |
| 537 |
ifOutBroadcastPkts Counter, |
| 538 |
-- ifHCInOctets Counter64, |
| 539 |
-- ifHCInUcastPkts Counter64, |
| 540 |
-- ifHCInMulticastPkts Counter64, |
| 541 |
-- ifHCInBroadcastPkts Counter64, |
| 542 |
-- ifHCOutOctets Counter64, |
| 543 |
-- ifHCOutUcastPkts Counter64, |
| 544 |
-- ifHCOutMulticastPkts Counter64, |
| 545 |
-- ifHCOutBroadcastPkts Counter64, |
| 546 |
ifLinkUpDownTrapEnable INTEGER, |
| 547 |
ifHighSpeed Gauge, |
| 548 |
ifPromiscuousMode TruthValue, |
| 549 |
ifConnectorPresent TruthValue, |
| 550 |
ifAlias DisplayString, |
| 551 |
ifCounterDiscontinuityTime TimeStamp |
| 552 |
} |
| 553 |
|
| 554 |
ifName OBJECT-TYPE |
| 555 |
SYNTAX DisplayString |
| 556 |
ACCESS read-only |
| 557 |
STATUS mandatory |
| 558 |
DESCRIPTION |
| 559 |
"The textual name of the interface. The value of this |
| 560 |
object should be the name of the interface as assigned by |
| 561 |
the local device and should be suitable for use in commands |
| 562 |
entered at the device's `console'. This might be a text |
| 563 |
name, such as `le0' or a simple port number, such as `1', |
| 564 |
depending on the interface naming syntax of the device. If |
| 565 |
several entries in the ifTable together represent a single |
| 566 |
interface as named by the device, then each will have the |
| 567 |
same value of ifName. Note that for an agent which responds |
| 568 |
to SNMP queries concerning an interface on some other |
| 569 |
(proxied) device, then the value of ifName for such an |
| 570 |
interface is the proxied device's local name for it. |
| 571 |
|
| 572 |
If there is no local name, or this object is otherwise not |
| 573 |
applicable, then this object contains a zero-length string." |
| 574 |
::= { ifXEntry 1 } |
| 575 |
|
| 576 |
ifInMulticastPkts OBJECT-TYPE |
| 577 |
SYNTAX Counter |
| 578 |
ACCESS read-only |
| 579 |
STATUS mandatory |
| 580 |
DESCRIPTION |
| 581 |
"The number of packets, delivered by this sub-layer to a |
| 582 |
higher (sub-)layer, which were addressed to a multicast |
| 583 |
address at this sub-layer. For a MAC layer protocol, this |
| 584 |
includes both Group and Functional addresses. |
| 585 |
|
| 586 |
Discontinuities in the value of this counter can occur at |
| 587 |
re-initialization of the management system, and at other |
| 588 |
|
| 589 |
|
| 590 |
times as indicated by the value of |
| 591 |
ifCounterDiscontinuityTime." |
| 592 |
::= { ifXEntry 2 } |
| 593 |
|
| 594 |
ifInBroadcastPkts OBJECT-TYPE |
| 595 |
SYNTAX Counter |
| 596 |
ACCESS read-only |
| 597 |
STATUS mandatory |
| 598 |
DESCRIPTION |
| 599 |
"The number of packets, delivered by this sub-layer to a |
| 600 |
higher (sub-)layer, which were addressed to a broadcast |
| 601 |
address at this sub-layer. |
| 602 |
|
| 603 |
Discontinuities in the value of this counter can occur at |
| 604 |
re-initialization of the management system, and at other |
| 605 |
times as indicated by the value of |
| 606 |
ifCounterDiscontinuityTime." |
| 607 |
::= { ifXEntry 3 } |
| 608 |
|
| 609 |
ifOutMulticastPkts OBJECT-TYPE |
| 610 |
SYNTAX Counter |
| 611 |
ACCESS read-only |
| 612 |
STATUS mandatory |
| 613 |
DESCRIPTION |
| 614 |
"The total number of packets that higher-level protocols |
| 615 |
requested be transmitted, and which were addressed to a |
| 616 |
multicast address at this sub-layer, including those that |
| 617 |
were discarded or not sent. For a MAC layer protocol, this |
| 618 |
includes both Group and Functional addresses. |
| 619 |
|
| 620 |
Discontinuities in the value of this counter can occur at |
| 621 |
re-initialization of the management system, and at other |
| 622 |
times as indicated by the value of |
| 623 |
ifCounterDiscontinuityTime." |
| 624 |
::= { ifXEntry 4 } |
| 625 |
|
| 626 |
ifOutBroadcastPkts OBJECT-TYPE |
| 627 |
SYNTAX Counter |
| 628 |
ACCESS read-only |
| 629 |
STATUS mandatory |
| 630 |
DESCRIPTION |
| 631 |
"The total number of packets that higher-level protocols |
| 632 |
requested be transmitted, and which were addressed to a |
| 633 |
broadcast address at this sub-layer, including those that |
| 634 |
were discarded or not sent. |
| 635 |
|
| 636 |
Discontinuities in the value of this counter can occur at |
| 637 |
re-initialization of the management system, and at other |
| 638 |
|
| 639 |
|
| 640 |
times as indicated by the value of |
| 641 |
ifCounterDiscontinuityTime." |
| 642 |
::= { ifXEntry 5 } |
| 643 |
|
| 644 |
-- ifHCInOctets OBJECT-TYPE |
| 645 |
-- SYNTAX Counter64 |
| 646 |
-- ACCESS read-only |
| 647 |
-- STATUS mandatory |
| 648 |
-- DESCRIPTION |
| 649 |
-- "The total number of octets received on the interface, |
| 650 |
-- including framing characters. This object is a 64-bit |
| 651 |
-- version of ifInOctets. |
| 652 |
-- |
| 653 |
-- Discontinuities in the value of this counter can occur at |
| 654 |
-- re-initialization of the management system, and at other |
| 655 |
-- times as indicated by the value of |
| 656 |
-- ifCounterDiscontinuityTime." |
| 657 |
-- ::= { ifXEntry 6 } |
| 658 |
|
| 659 |
-- ifHCInUcastPkts OBJECT-TYPE |
| 660 |
-- SYNTAX Counter64 |
| 661 |
-- ACCESS read-only |
| 662 |
-- STATUS mandatory |
| 663 |
-- DESCRIPTION |
| 664 |
-- "The number of packets, delivered by this sub-layer to a |
| 665 |
-- higher (sub-)layer, which were not addressed to a multicast |
| 666 |
-- or broadcast address at this sub-layer. This object is a |
| 667 |
-- 64-bit version of ifInUcastPkts. |
| 668 |
-- |
| 669 |
-- Discontinuities in the value of this counter can occur at |
| 670 |
-- re-initialization of the management system, and at other |
| 671 |
-- times as indicated by the value of |
| 672 |
-- ifCounterDiscontinuityTime." |
| 673 |
-- ::= { ifXEntry 7 } |
| 674 |
|
| 675 |
-- ifHCInMulticastPkts OBJECT-TYPE |
| 676 |
-- SYNTAX Counter64 |
| 677 |
-- ACCESS read-only |
| 678 |
-- STATUS mandatory |
| 679 |
-- DESCRIPTION |
| 680 |
-- "The number of packets, delivered by this sub-layer to a |
| 681 |
-- higher (sub-)layer, which were addressed to a multicast |
| 682 |
-- address at this sub-layer. For a MAC layer protocol, this |
| 683 |
-- includes both Group and Functional addresses. This object |
| 684 |
-- is a 64-bit version of ifInMulticastPkts. |
| 685 |
-- |
| 686 |
-- Discontinuities in the value of this counter can occur at |
| 687 |
-- re-initialization of the management system, and at other |
| 688 |
-- times as indicated by the value of |
| 689 |
-- ifCounterDiscontinuityTime." |
| 690 |
-- ::= { ifXEntry 8 } |
| 691 |
|
| 692 |
-- ifHCInBroadcastPkts OBJECT-TYPE |
| 693 |
-- SYNTAX Counter64 |
| 694 |
-- ACCESS read-only |
| 695 |
-- STATUS mandatory |
| 696 |
-- DESCRIPTION |
| 697 |
-- "The number of packets, delivered by this sub-layer to a |
| 698 |
-- higher (sub-)layer, which were addressed to a broadcast |
| 699 |
-- address at this sub-layer. This object is a 64-bit version |
| 700 |
-- of ifInBroadcastPkts. |
| 701 |
-- |
| 702 |
-- Discontinuities in the value of this counter can occur at |
| 703 |
-- re-initialization of the management system, and at other |
| 704 |
-- times as indicated by the value of |
| 705 |
-- ifCounterDiscontinuityTime." |
| 706 |
-- ::= { ifXEntry 9 } |
| 707 |
|
| 708 |
-- ifHCOutOctets OBJECT-TYPE |
| 709 |
-- SYNTAX Counter64 |
| 710 |
-- ACCESS read-only |
| 711 |
-- STATUS mandatory |
| 712 |
-- DESCRIPTION |
| 713 |
-- "The total number of octets transmitted out of the |
| 714 |
-- interface, including framing characters. This object is a |
| 715 |
-- 64-bit version of ifOutOctets. |
| 716 |
-- |
| 717 |
-- Discontinuities in the value of this counter can occur at |
| 718 |
-- re-initialization of the management system, and at other |
| 719 |
-- times as indicated by the value of |
| 720 |
-- ifCounterDiscontinuityTime." |
| 721 |
-- ::= { ifXEntry 10 } |
| 722 |
|
| 723 |
-- ifHCOutUcastPkts OBJECT-TYPE |
| 724 |
-- SYNTAX Counter64 |
| 725 |
-- ACCESS read-only |
| 726 |
-- STATUS mandatory |
| 727 |
-- DESCRIPTION |
| 728 |
-- "The total number of packets that higher-level protocols |
| 729 |
-- requested be transmitted, and which were not addressed to a |
| 730 |
-- multicast or broadcast address at this sub-layer, including |
| 731 |
-- those that were discarded or not sent. This object is a |
| 732 |
-- 64-bit version of ifOutUcastPkts. |
| 733 |
-- |
| 734 |
-- Discontinuities in the value of this counter can occur at |
| 735 |
-- re-initialization of the management system, and at other |
| 736 |
-- times as indicated by the value of |
| 737 |
-- ifCounterDiscontinuityTime." |
| 738 |
-- ::= { ifXEntry 11 } |
| 739 |
|
| 740 |
-- ifHCOutMulticastPkts OBJECT-TYPE |
| 741 |
-- SYNTAX Counter64 |
| 742 |
-- ACCESS read-only |
| 743 |
-- STATUS mandatory |
| 744 |
-- DESCRIPTION |
| 745 |
-- "The total number of packets that higher-level protocols |
| 746 |
-- requested be transmitted, and which were addressed to a |
| 747 |
-- multicast address at this sub-layer, including those that |
| 748 |
-- were discarded or not sent. For a MAC layer protocol, this |
| 749 |
-- includes both Group and Functional addresses. This object |
| 750 |
-- is a 64-bit version of ifOutMulticastPkts. |
| 751 |
-- |
| 752 |
-- Discontinuities in the value of this counter can occur at |
| 753 |
-- re-initialization of the management system, and at other |
| 754 |
-- times as indicated by the value of |
| 755 |
-- ifCounterDiscontinuityTime." |
| 756 |
-- ::= { ifXEntry 12 } |
| 757 |
|
| 758 |
-- ifHCOutBroadcastPkts OBJECT-TYPE |
| 759 |
-- SYNTAX Counter64 |
| 760 |
-- ACCESS read-only |
| 761 |
-- STATUS mandatory |
| 762 |
-- DESCRIPTION |
| 763 |
-- "The total number of packets that higher-level protocols |
| 764 |
-- requested be transmitted, and which were addressed to a |
| 765 |
-- broadcast address at this sub-layer, including those that |
| 766 |
-- were discarded or not sent. This object is a 64-bit version |
| 767 |
-- of ifOutBroadcastPkts. |
| 768 |
-- |
| 769 |
-- Discontinuities in the value of this counter can occur at |
| 770 |
-- re-initialization of the management system, and at other |
| 771 |
-- times as indicated by the value of |
| 772 |
-- ifCounterDiscontinuityTime." |
| 773 |
-- ::= { ifXEntry 13 } |
| 774 |
|
| 775 |
ifLinkUpDownTrapEnable OBJECT-TYPE |
| 776 |
SYNTAX INTEGER { enabled(1), disabled(2) } |
| 777 |
ACCESS read-write |
| 778 |
STATUS mandatory |
| 779 |
DESCRIPTION |
| 780 |
"Indicates whether linkUp/linkDown traps should be generated |
| 781 |
for this interface. |
| 782 |
|
| 783 |
By default, this object should have the value enabled(1) for |
| 784 |
interfaces which do not operate on 'top' of any other |
| 785 |
interface (as defined in the ifStackTable), and disabled(2) |
| 786 |
otherwise." |
| 787 |
::= { ifXEntry 14 } |
| 788 |
|
| 789 |
ifHighSpeed OBJECT-TYPE |
| 790 |
SYNTAX Gauge |
| 791 |
ACCESS read-only |
| 792 |
STATUS mandatory |
| 793 |
DESCRIPTION |
| 794 |
"An estimate of the interface's current bandwidth in units |
| 795 |
of 1,000,000 bits per second. If this object reports a |
| 796 |
value of `n' then the speed of the interface is somewhere in |
| 797 |
the range of `n-500,000' to `n+499,999'. For interfaces |
| 798 |
which do not vary in bandwidth or for those where no |
| 799 |
accurate estimation can be made, this object should contain |
| 800 |
the nominal bandwidth. For a sub-layer which has no concept |
| 801 |
of bandwidth, this object should be zero." |
| 802 |
::= { ifXEntry 15 } |
| 803 |
|
| 804 |
ifPromiscuousMode OBJECT-TYPE |
| 805 |
SYNTAX TruthValue |
| 806 |
ACCESS read-write |
| 807 |
STATUS mandatory |
| 808 |
DESCRIPTION |
| 809 |
"This object has a value of false(2) if this interface only |
| 810 |
accepts packets/frames that are addressed to this station. |
| 811 |
This object has a value of true(1) when the station accepts |
| 812 |
all packets/frames transmitted on the media. The value |
| 813 |
true(1) is only legal on certain types of media. If legal, |
| 814 |
setting this object to a value of true(1) may require the |
| 815 |
interface to be reset before becoming effective. |
| 816 |
|
| 817 |
The value of ifPromiscuousMode does not affect the reception |
| 818 |
of broadcast and multicast packets/frames by the interface." |
| 819 |
::= { ifXEntry 16 } |
| 820 |
|
| 821 |
ifConnectorPresent OBJECT-TYPE |
| 822 |
SYNTAX TruthValue |
| 823 |
ACCESS read-only |
| 824 |
STATUS mandatory |
| 825 |
DESCRIPTION |
| 826 |
"This object has the value 'true(1)' if the interface |
| 827 |
sublayer has a physical connector and the value 'false(2)' |
| 828 |
otherwise." |
| 829 |
::= { ifXEntry 17 } |
| 830 |
|
| 831 |
ifAlias OBJECT-TYPE |
| 832 |
SYNTAX DisplayString (SIZE(0..64)) |
| 833 |
ACCESS read-write |
| 834 |
STATUS mandatory |
| 835 |
DESCRIPTION |
| 836 |
"This object is an 'alias' name for the interface as |
| 837 |
specified by a network manager, and provides a non-volatile |
| 838 |
'handle' for the interface. |
| 839 |
|
| 840 |
On the first instantiation of an interface, the value of |
| 841 |
ifAlias associated with that interface is the zero-length |
| 842 |
string. As and when a value is written into an instance of |
| 843 |
ifAlias through a network management set operation, then the |
| 844 |
agent must retain the supplied value in the ifAlias instance |
| 845 |
associated with the same interface for as long as that |
| 846 |
interface remains instantiated, including across all re- |
| 847 |
initializations/reboots of the network management system, |
| 848 |
including those which result in a change of the interface's |
| 849 |
ifIndex value. |
| 850 |
|
| 851 |
An example of the value which a network manager might store |
| 852 |
in this object for a WAN interface is the (Telco's) circuit |
| 853 |
number/identifier of the interface. |
| 854 |
|
| 855 |
Some agents may support write-access only for interfaces |
| 856 |
having particular values of ifType. An agent which supports |
| 857 |
write access to this object is required to keep the value in |
| 858 |
non-volatile storage, but it may limit the length of new |
| 859 |
values depending on how much storage is already occupied by |
| 860 |
the current values for other interfaces." |
| 861 |
::= { ifXEntry 18 } |
| 862 |
|
| 863 |
ifCounterDiscontinuityTime OBJECT-TYPE |
| 864 |
SYNTAX TimeStamp |
| 865 |
ACCESS read-only |
| 866 |
STATUS mandatory |
| 867 |
DESCRIPTION |
| 868 |
"The value of sysUpTime on the most recent occasion at which |
| 869 |
any one or more of this interface's counters suffered a |
| 870 |
discontinuity. The relevant counters are the specific |
| 871 |
instances associated with this interface of any Counter32 or |
| 872 |
|
| 873 |
|
| 874 |
Counter64 object contained in the ifTable or ifXTable. If |
| 875 |
no such discontinuities have occurred since the last re- |
| 876 |
initialization of the local management subsystem, then this |
| 877 |
object contains a zero value." |
| 878 |
::= { ifXEntry 19 } |
| 879 |
|
| 880 |
ifStackTable OBJECT-TYPE |
| 881 |
SYNTAX SEQUENCE OF IfStackEntry |
| 882 |
ACCESS not-accessible |
| 883 |
STATUS mandatory |
| 884 |
DESCRIPTION |
| 885 |
"The table containing information on the relationships |
| 886 |
between the multiple sub-layers of network interfaces. In |
| 887 |
particular, it contains information on which sub-layers run |
| 888 |
'on top of' which other sub-layers, where each sub-layer |
| 889 |
corresponds to a conceptual row in the ifTable. For |
| 890 |
example, when the sub-layer with ifIndex value x runs over |
| 891 |
the sub-layer with ifIndex value y, then this table |
| 892 |
contains: |
| 893 |
|
| 894 |
ifStackStatus.x.y=active |
| 895 |
|
| 896 |
For each ifIndex value, I, which identifies an active |
| 897 |
interface, there are always at least two instantiated rows |
| 898 |
in this table associated with I. For one of these rows, I |
| 899 |
is the value of ifStackHigherLayer; for the other, I is the |
| 900 |
value of ifStackLowerLayer. (If I is not involved in |
| 901 |
multiplexing, then these are the only two rows associated |
| 902 |
with I.) |
| 903 |
|
| 904 |
For example, two rows exist even for an interface which has |
| 905 |
no others stacked on top or below it: |
| 906 |
|
| 907 |
ifStackStatus.0.x=active |
| 908 |
ifStackStatus.x.0=active " |
| 909 |
::= { ifMIBObjects 2 } |
| 910 |
|
| 911 |
ifStackEntry OBJECT-TYPE |
| 912 |
SYNTAX IfStackEntry |
| 913 |
ACCESS not-accessible |
| 914 |
STATUS mandatory |
| 915 |
DESCRIPTION |
| 916 |
"Information on a particular relationship between two sub- |
| 917 |
layers, specifying that one sub-layer runs on 'top' of the |
| 918 |
other sub-layer. Each sub-layer corresponds to a conceptual |
| 919 |
row in the ifTable." |
| 920 |
INDEX { ifStackHigherLayer, ifStackLowerLayer } |
| 921 |
::= { ifStackTable 1 } |
| 922 |
|
| 923 |
IfStackEntry ::= SEQUENCE { |
| 924 |
ifStackHigherLayer InterfaceIndexOrZero, |
| 925 |
ifStackLowerLayer InterfaceIndexOrZero, |
| 926 |
ifStackStatus RowStatus |
| 927 |
} |
| 928 |
|
| 929 |
ifStackHigherLayer OBJECT-TYPE |
| 930 |
SYNTAX InterfaceIndexOrZero |
| 931 |
ACCESS not-accessible |
| 932 |
STATUS mandatory |
| 933 |
DESCRIPTION |
| 934 |
"The value of ifIndex corresponding to the higher sub-layer |
| 935 |
of the relationship, i.e., the sub-layer which runs on 'top' |
| 936 |
of the sub-layer identified by the corresponding instance of |
| 937 |
ifStackLowerLayer. If there is no higher sub-layer (below |
| 938 |
the internetwork layer), then this object has the value 0." |
| 939 |
::= { ifStackEntry 1 } |
| 940 |
|
| 941 |
ifStackLowerLayer OBJECT-TYPE |
| 942 |
SYNTAX InterfaceIndexOrZero |
| 943 |
ACCESS not-accessible |
| 944 |
STATUS mandatory |
| 945 |
DESCRIPTION |
| 946 |
"The value of ifIndex corresponding to the lower sub-layer |
| 947 |
of the relationship, i.e., the sub-layer which runs 'below' |
| 948 |
the sub-layer identified by the corresponding instance of |
| 949 |
ifStackHigherLayer. If there is no lower sub-layer, then |
| 950 |
this object has the value 0." |
| 951 |
::= { ifStackEntry 2 } |
| 952 |
|
| 953 |
ifStackStatus OBJECT-TYPE |
| 954 |
SYNTAX RowStatus |
| 955 |
ACCESS read-write |
| 956 |
STATUS mandatory |
| 957 |
DESCRIPTION |
| 958 |
"The status of the relationship between two sub-layers. |
| 959 |
|
| 960 |
Changing the value of this object from 'active' to |
| 961 |
'notInService' or 'destroy' will likely have consequences up |
| 962 |
and down the interface stack. Thus, write access to this |
| 963 |
object is likely to be inappropriate for some types of |
| 964 |
interfaces, and many implementations will choose not to |
| 965 |
support write-access for any type of interface." |
| 966 |
::= { ifStackEntry 3 } |
| 967 |
|
| 968 |
ifTestTable OBJECT-TYPE |
| 969 |
SYNTAX SEQUENCE OF IfTestEntry |
| 970 |
ACCESS not-accessible |
| 971 |
STATUS deprecated |
| 972 |
DESCRIPTION |
| 973 |
"This table contains one entry per interface. It defines |
| 974 |
objects which allow a network manager to instruct an agent |
| 975 |
to test an interface for various faults. Tests for an |
| 976 |
interface are defined in the media-specific MIB for that |
| 977 |
interface. After invoking a test, the object ifTestResult |
| 978 |
can be read to determine the outcome. If an agent can not |
| 979 |
perform the test, ifTestResult is set to so indicate. The |
| 980 |
object ifTestCode can be used to provide further test- |
| 981 |
specific or interface-specific (or even enterprise-specific) |
| 982 |
information concerning the outcome of the test. Only one |
| 983 |
test can be in progress on each interface at any one time. |
| 984 |
If one test is in progress when another test is invoked, the |
| 985 |
second test is rejected. Some agents may reject a test when |
| 986 |
a prior test is active on another interface. |
| 987 |
|
| 988 |
Before starting a test, a manager-station must first obtain |
| 989 |
'ownership' of the entry in the ifTestTable for the |
| 990 |
interface to be tested. This is accomplished with the |
| 991 |
ifTestId and ifTestStatus objects as follows: |
| 992 |
|
| 993 |
try_again: |
| 994 |
get (ifTestId, ifTestStatus) |
| 995 |
while (ifTestStatus != notInUse) |
| 996 |
/* |
| 997 |
* Loop while a test is running or some other |
| 998 |
* manager is configuring a test. |
| 999 |
*/ |
| 1000 |
short delay |
| 1001 |
get (ifTestId, ifTestStatus) |
| 1002 |
} |
| 1003 |
|
| 1004 |
/* |
| 1005 |
* Is not being used right now -- let's compete |
| 1006 |
* to see who gets it. |
| 1007 |
*/ |
| 1008 |
lock_value = ifTestId |
| 1009 |
|
| 1010 |
if ( set(ifTestId = lock_value, ifTestStatus = inUse, |
| 1011 |
|
| 1012 |
|
| 1013 |
ifTestOwner = 'my-IP-address') == FAILURE) |
| 1014 |
/* |
| 1015 |
* Another manager got the ifTestEntry -- go |
| 1016 |
* try again |
| 1017 |
*/ |
| 1018 |
goto try_again; |
| 1019 |
|
| 1020 |
/* |
| 1021 |
* I have the lock |
| 1022 |
*/ |
| 1023 |
set up any test parameters. |
| 1024 |
|
| 1025 |
/* |
| 1026 |
* This starts the test |
| 1027 |
*/ |
| 1028 |
set(ifTestType = test_to_run); |
| 1029 |
|
| 1030 |
wait for test completion by polling ifTestResult |
| 1031 |
|
| 1032 |
when test completes, agent sets ifTestResult |
| 1033 |
agent also sets ifTestStatus = 'notInUse' |
| 1034 |
|
| 1035 |
retrieve any additional test results, and ifTestId |
| 1036 |
|
| 1037 |
if (ifTestId == lock_value+1) results are valid |
| 1038 |
|
| 1039 |
A manager station first retrieves the value of the |
| 1040 |
appropriate ifTestId and ifTestStatus objects, periodically |
| 1041 |
repeating the retrieval if necessary, until the value of |
| 1042 |
ifTestStatus is 'notInUse'. The manager station then tries |
| 1043 |
to set the same ifTestId object to the value it just |
| 1044 |
retrieved, the same ifTestStatus object to 'inUse', and the |
| 1045 |
corresponding ifTestOwner object to a value indicating |
| 1046 |
itself. If the set operation succeeds then the manager has |
| 1047 |
obtained ownership of the ifTestEntry, and the value of the |
| 1048 |
ifTestId object is incremented by the agent (per the |
| 1049 |
semantics of TestAndIncr). Failure of the set operation |
| 1050 |
indicates that some other manager has obtained ownership of |
| 1051 |
the ifTestEntry. |
| 1052 |
|
| 1053 |
Once ownership is obtained, any test parameters can be |
| 1054 |
setup, and then the test is initiated by setting ifTestType. |
| 1055 |
On completion of the test, the agent sets ifTestStatus to |
| 1056 |
'notInUse'. Once this occurs, the manager can retrieve the |
| 1057 |
results. In the (rare) event that the invocation of tests |
| 1058 |
by two network managers were to overlap, then there would be |
| 1059 |
a possibility that the first test's results might be |
| 1060 |
overwritten by the second test's results prior to the first |
| 1061 |
|
| 1062 |
|
| 1063 |
results being read. This unlikely circumstance can be |
| 1064 |
detected by a network manager retrieving ifTestId at the |
| 1065 |
same time as retrieving the test results, and ensuring that |
| 1066 |
the results are for the desired request. |
| 1067 |
|
| 1068 |
If ifTestType is not set within an abnormally long period of |
| 1069 |
time after ownership is obtained, the agent should time-out |
| 1070 |
the manager, and reset the value of the ifTestStatus object |
| 1071 |
back to 'notInUse'. It is suggested that this time-out |
| 1072 |
period be 5 minutes. |
| 1073 |
|
| 1074 |
In general, a management station must not retransmit a |
| 1075 |
request to invoke a test for which it does not receive a |
| 1076 |
response; instead, it properly inspects an agent's MIB to |
| 1077 |
determine if the invocation was successful. Only if the |
| 1078 |
invocation was unsuccessful, is the invocation request |
| 1079 |
retransmitted. |
| 1080 |
|
| 1081 |
Some tests may require the interface to be taken off-line in |
| 1082 |
order to execute them, or may even require the agent to |
| 1083 |
reboot after completion of the test. In these |
| 1084 |
circumstances, communication with the management station |
| 1085 |
invoking the test may be lost until after completion of the |
| 1086 |
test. An agent is not required to support such tests. |
| 1087 |
However, if such tests are supported, then the agent should |
| 1088 |
make every effort to transmit a response to the request |
| 1089 |
which invoked the test prior to losing communication. When |
| 1090 |
the agent is restored to normal service, the results of the |
| 1091 |
test are properly made available in the appropriate objects. |
| 1092 |
Note that this requires that the ifIndex value assigned to |
| 1093 |
an interface must be unchanged even if the test causes a |
| 1094 |
reboot. An agent must reject any test for which it cannot, |
| 1095 |
perhaps due to resource constraints, make available at least |
| 1096 |
the minimum amount of information after that test |
| 1097 |
completes." |
| 1098 |
::= { ifMIBObjects 3 } |
| 1099 |
|
| 1100 |
ifTestEntry OBJECT-TYPE |
| 1101 |
SYNTAX IfTestEntry |
| 1102 |
ACCESS not-accessible |
| 1103 |
STATUS deprecated |
| 1104 |
DESCRIPTION |
| 1105 |
"An entry containing objects for invoking tests on an |
| 1106 |
interface." |
| 1107 |
INDEX { ifIndex } |
| 1108 |
-- AUGMENTS { ifEntry } |
| 1109 |
::= { ifTestTable 1 } |
| 1110 |
|
| 1111 |
IfTestEntry ::= SEQUENCE { |
| 1112 |
ifTestId TestAndIncr, |
| 1113 |
ifTestStatus INTEGER, |
| 1114 |
ifTestType AutonomousType, |
| 1115 |
ifTestResult INTEGER, |
| 1116 |
ifTestCode OBJECT IDENTIFIER, |
| 1117 |
ifTestOwner OwnerString |
| 1118 |
} |
| 1119 |
|
| 1120 |
ifTestId OBJECT-TYPE |
| 1121 |
SYNTAX TestAndIncr |
| 1122 |
ACCESS read-write |
| 1123 |
STATUS deprecated |
| 1124 |
DESCRIPTION |
| 1125 |
"This object identifies the current invocation of the |
| 1126 |
interface's test." |
| 1127 |
::= { ifTestEntry 1 } |
| 1128 |
|
| 1129 |
ifTestStatus OBJECT-TYPE |
| 1130 |
SYNTAX INTEGER { notInUse(1), inUse(2) } |
| 1131 |
ACCESS read-write |
| 1132 |
STATUS deprecated |
| 1133 |
DESCRIPTION |
| 1134 |
"This object indicates whether or not some manager currently |
| 1135 |
has the necessary 'ownership' required to invoke a test on |
| 1136 |
this interface. A write to this object is only successful |
| 1137 |
when it changes its value from 'notInUse(1)' to 'inUse(2)'. |
| 1138 |
After completion of a test, the agent resets the value back |
| 1139 |
to 'notInUse(1)'." |
| 1140 |
::= { ifTestEntry 2 } |
| 1141 |
|
| 1142 |
ifTestType OBJECT-TYPE |
| 1143 |
SYNTAX AutonomousType |
| 1144 |
ACCESS read-write |
| 1145 |
STATUS deprecated |
| 1146 |
DESCRIPTION |
| 1147 |
"A control variable used to start and stop operator- |
| 1148 |
initiated interface tests. Most OBJECT IDENTIFIER values |
| 1149 |
assigned to tests are defined elsewhere, in association with |
| 1150 |
specific types of interface. However, this document assigns |
| 1151 |
a value for a full-duplex loopback test, and defines the |
| 1152 |
special meanings of the subject identifier: |
| 1153 |
|
| 1154 |
noTest OBJECT IDENTIFIER ::= { 0 0 } |
| 1155 |
|
| 1156 |
When the value noTest is written to this object, no action |
| 1157 |
is taken unless a test is in progress, in which case the |
| 1158 |
test is aborted. Writing any other value to this object is |
| 1159 |
|
| 1160 |
|
| 1161 |
only valid when no test is currently in progress, in which |
| 1162 |
case the indicated test is initiated. |
| 1163 |
|
| 1164 |
When read, this object always returns the most recent value |
| 1165 |
that ifTestType was set to. If it has not been set since |
| 1166 |
the last initialization of the network management subsystem |
| 1167 |
on the agent, a value of noTest is returned." |
| 1168 |
::= { ifTestEntry 3 } |
| 1169 |
|
| 1170 |
ifTestResult OBJECT-TYPE |
| 1171 |
SYNTAX INTEGER { none(1), success(2), inProgress(3), |
| 1172 |
notSupported(4), unAbleToRun(5), aborted(6), |
| 1173 |
failed(7) } |
| 1174 |
ACCESS read-only |
| 1175 |
STATUS deprecated |
| 1176 |
DESCRIPTION |
| 1177 |
"This object contains the result of the most recently |
| 1178 |
requested test, or the value none(1) if no tests have been |
| 1179 |
requested since the last reset. Note that this facility |
| 1180 |
provides no provision for saving the results of one test |
| 1181 |
when starting another, as could be required if used by |
| 1182 |
multiple managers concurrently." |
| 1183 |
::= { ifTestEntry 4 } |
| 1184 |
|
| 1185 |
ifTestCode OBJECT-TYPE |
| 1186 |
SYNTAX OBJECT IDENTIFIER |
| 1187 |
ACCESS read-only |
| 1188 |
STATUS deprecated |
| 1189 |
DESCRIPTION |
| 1190 |
"This object contains a code which contains more specific |
| 1191 |
information on the test result, for example an error-code |
| 1192 |
after a failed test. Error codes and other values this |
| 1193 |
object may take are specific to the type of interface and/or |
| 1194 |
test. The value may have the semantics of either the |
| 1195 |
AutonomousType or InstancePointer textual conventions as |
| 1196 |
defined in RFC 2579. The identifier: |
| 1197 |
|
| 1198 |
testCodeUnknown OBJECT IDENTIFIER ::= { 0 0 } |
| 1199 |
|
| 1200 |
is defined for use if no additional result code is |
| 1201 |
available." |
| 1202 |
::= { ifTestEntry 5 } |
| 1203 |
|
| 1204 |
ifTestOwner OBJECT-TYPE |
| 1205 |
SYNTAX OwnerString |
| 1206 |
ACCESS read-write |
| 1207 |
STATUS deprecated |
| 1208 |
DESCRIPTION |
| 1209 |
"The entity which currently has the 'ownership' required to |
| 1210 |
invoke a test on this interface." |
| 1211 |
::= { ifTestEntry 6 } |
| 1212 |
|
| 1213 |
ifRcvAddressTable OBJECT-TYPE |
| 1214 |
SYNTAX SEQUENCE OF IfRcvAddressEntry |
| 1215 |
ACCESS not-accessible |
| 1216 |
STATUS mandatory |
| 1217 |
DESCRIPTION |
| 1218 |
"This table contains an entry for each address (broadcast, |
| 1219 |
multicast, or uni-cast) for which the system will receive |
| 1220 |
packets/frames on a particular interface, except as follows: |
| 1221 |
|
| 1222 |
- for an interface operating in promiscuous mode, entries |
| 1223 |
are only required for those addresses for which the system |
| 1224 |
would receive frames were it not operating in promiscuous |
| 1225 |
mode. |
| 1226 |
|
| 1227 |
|
| 1228 |
- for 802.5 functional addresses, only one entry is |
| 1229 |
required, for the address which has the functional address |
| 1230 |
bit ANDed with the bit mask of all functional addresses for |
| 1231 |
which the interface will accept frames. |
| 1232 |
|
| 1233 |
A system is normally able to use any unicast address which |
| 1234 |
corresponds to an entry in this table as a source address." |
| 1235 |
::= { ifMIBObjects 4 } |
| 1236 |
|
| 1237 |
ifRcvAddressEntry OBJECT-TYPE |
| 1238 |
SYNTAX IfRcvAddressEntry |
| 1239 |
ACCESS not-accessible |
| 1240 |
STATUS mandatory |
| 1241 |
DESCRIPTION |
| 1242 |
"A list of objects identifying an address for which the |
| 1243 |
system will accept packets/frames on the particular |
| 1244 |
interface identified by the index value ifIndex." |
| 1245 |
INDEX { ifIndex, ifRcvAddressAddress } |
| 1246 |
::= { ifRcvAddressTable 1 } |
| 1247 |
|
| 1248 |
IfRcvAddressEntry ::= SEQUENCE { |
| 1249 |
ifRcvAddressAddress PhysAddress, |
| 1250 |
ifRcvAddressStatus RowStatus, |
| 1251 |
ifRcvAddressType INTEGER |
| 1252 |
} |
| 1253 |
|
| 1254 |
ifRcvAddressAddress OBJECT-TYPE |
| 1255 |
SYNTAX PhysAddress |
| 1256 |
ACCESS not-accessible |
| 1257 |
STATUS mandatory |
| 1258 |
DESCRIPTION |
| 1259 |
"An address for which the system will accept packets/frames |
| 1260 |
on this entry's interface." |
| 1261 |
::= { ifRcvAddressEntry 1 } |
| 1262 |
|
| 1263 |
ifRcvAddressStatus OBJECT-TYPE |
| 1264 |
SYNTAX RowStatus |
| 1265 |
ACCESS read-write |
| 1266 |
STATUS mandatory |
| 1267 |
DESCRIPTION |
| 1268 |
"This object is used to create and delete rows in the |
| 1269 |
ifRcvAddressTable." |
| 1270 |
::= { ifRcvAddressEntry 2 } |
| 1271 |
|
| 1272 |
ifRcvAddressType OBJECT-TYPE |
| 1273 |
SYNTAX INTEGER { other(1), volatile(2), nonVolatile(3) } |
| 1274 |
ACCESS read-write |
| 1275 |
STATUS mandatory |
| 1276 |
DESCRIPTION |
| 1277 |
"This object has the value nonVolatile(3) for those entries |
| 1278 |
in the table which are valid and will not be deleted by the |
| 1279 |
next restart of the managed system. Entries having the |
| 1280 |
value volatile(2) are valid and exist, but have not been |
| 1281 |
saved, so that will not exist after the next restart of the |
| 1282 |
managed system. Entries having the value other(1) are valid |
| 1283 |
and exist but are not classified as to whether they will |
| 1284 |
continue to exist after the next restart." |
| 1285 |
DEFVAL { volatile } |
| 1286 |
::= { ifRcvAddressEntry 3 } |
| 1287 |
|
| 1288 |
ifTableLastChange OBJECT-TYPE |
| 1289 |
SYNTAX TimeTicks |
| 1290 |
ACCESS read-only |
| 1291 |
STATUS mandatory |
| 1292 |
DESCRIPTION |
| 1293 |
"The value of sysUpTime at the time of the last creation or |
| 1294 |
deletion of an entry in the ifTable. If the number of |
| 1295 |
entries has been unchanged since the last re-initialization |
| 1296 |
of the local network management subsystem, then this object |
| 1297 |
contains a zero value." |
| 1298 |
::= { ifMIBObjects 5 } |
| 1299 |
|
| 1300 |
ifStackLastChange OBJECT-TYPE |
| 1301 |
SYNTAX TimeTicks |
| 1302 |
ACCESS read-only |
| 1303 |
STATUS mandatory |
| 1304 |
DESCRIPTION |
| 1305 |
"The value of sysUpTime at the time of the last change of |
| 1306 |
the (whole) interface stack. A change of the interface |
| 1307 |
stack is defined to be any creation, deletion, or change in |
| 1308 |
value of any instance of ifStackStatus. If the interface |
| 1309 |
stack has been unchanged since the last re-initialization of |
| 1310 |
the local network management subsystem, then this object |
| 1311 |
contains a zero value." |
| 1312 |
::= { ifMIBObjects 6 } |
| 1313 |
|
| 1314 |
ifConformance OBJECT IDENTIFIER |
| 1315 |
::= { ifMIB 2 } |
| 1316 |
|
| 1317 |
ifGroups OBJECT IDENTIFIER |
| 1318 |
::= { ifConformance 1 } |
| 1319 |
|
| 1320 |
ifCompliances OBJECT IDENTIFIER |
| 1321 |
::= { ifConformance 2 } |
| 1322 |
|
| 1323 |
linkDown TRAP-TYPE |
| 1324 |
ENTERPRISE snmpTraps |
| 1325 |
VARIABLES { ifIndex, ifAdminStatus, ifOperStatus } |
| 1326 |
-- STATUS mandatory |
| 1327 |
DESCRIPTION |
| 1328 |
"A linkDown trap signifies that the SNMP entity, acting in |
| 1329 |
an agent role, has detected that the ifOperStatus object for |
| 1330 |
one of its communication links is about to enter the down |
| 1331 |
state from some other state (but not from the notPresent |
| 1332 |
state). This other state is indicated by the included value |
| 1333 |
of ifOperStatus." |
| 1334 |
::= 3 |
| 1335 |
|
| 1336 |
linkUp TRAP-TYPE |
| 1337 |
ENTERPRISE snmpTraps |
| 1338 |
VARIABLES { ifIndex, ifAdminStatus, ifOperStatus } |
| 1339 |
-- STATUS mandatory |
| 1340 |
DESCRIPTION |
| 1341 |
"A linkUp trap signifies that the SNMP entity, acting in an |
| 1342 |
agent role, has detected that the ifOperStatus object for |
| 1343 |
one of its communication links left the down state and |
| 1344 |
transitioned into some other state (but not into the |
| 1345 |
notPresent state). This other state is indicated by the |
| 1346 |
included value of ifOperStatus." |
| 1347 |
::= 4 |
| 1348 |
|
| 1349 |
ifGeneralGroup OBJECT IDENTIFIER |
| 1350 |
::= { ifGroups 1 } |
| 1351 |
|
| 1352 |
-- ifGeneralGroup OBJECT-GROUP |
| 1353 |
-- OBJECTS { ifDescr, ifType, ifSpeed, ifPhysAddress, |
| 1354 |
-- ifAdminStatus, ifOperStatus, ifLastChange, |
| 1355 |
-- ifLinkUpDownTrapEnable, ifConnectorPresent, |
| 1356 |
-- ifHighSpeed, ifName } |
| 1357 |
-- STATUS deprecated |
| 1358 |
-- DESCRIPTION |
| 1359 |
-- "A collection of objects deprecated in favour of |
| 1360 |
-- ifGeneralInformationGroup." |
| 1361 |
-- ::= { ifGroups 1 } |
| 1362 |
|
| 1363 |
ifFixedLengthGroup OBJECT IDENTIFIER |
| 1364 |
::= { ifGroups 2 } |
| 1365 |
|
| 1366 |
-- ifFixedLengthGroup OBJECT-GROUP |
| 1367 |
-- OBJECTS { ifInOctets, ifOutOctets, ifInUnknownProtos, |
| 1368 |
-- ifInErrors, ifOutErrors } |
| 1369 |
-- STATUS mandatory |
| 1370 |
-- DESCRIPTION |
| 1371 |
-- "A collection of objects providing information specific to |
| 1372 |
-- non-high speed (non-high speed interfaces transmit and |
| 1373 |
-- receive at speeds less than or equal to 20,000,000 |
| 1374 |
-- bits/second) character-oriented or fixed-length-transmission |
| 1375 |
-- network interfaces." |
| 1376 |
-- ::= { ifGroups 2 } |
| 1377 |
|
| 1378 |
ifHCFixedLengthGroup OBJECT IDENTIFIER |
| 1379 |
::= { ifGroups 3 } |
| 1380 |
|
| 1381 |
-- ifHCFixedLengthGroup OBJECT-GROUP |
| 1382 |
-- OBJECTS { ifHCInOctets, ifHCOutOctets, ifInOctets, |
| 1383 |
-- ifOutOctets, ifInUnknownProtos, ifInErrors, |
| 1384 |
-- ifOutErrors } |
| 1385 |
-- STATUS mandatory |
| 1386 |
-- DESCRIPTION |
| 1387 |
-- "A collection of objects providing information specific to |
| 1388 |
-- high speed (greater than 20,000,000 bits/second) character- |
| 1389 |
-- oriented or fixed-length-transmission network interfaces." |
| 1390 |
-- ::= { ifGroups 3 } |
| 1391 |
|
| 1392 |
ifPacketGroup OBJECT IDENTIFIER |
| 1393 |
::= { ifGroups 4 } |
| 1394 |
|
| 1395 |
-- ifPacketGroup OBJECT-GROUP |
| 1396 |
-- OBJECTS { ifInOctets, ifOutOctets, ifInUnknownProtos, |
| 1397 |
-- ifInErrors, ifOutErrors, ifMtu, ifInUcastPkts, |
| 1398 |
-- ifInMulticastPkts, ifInBroadcastPkts, ifInDiscards, |
| 1399 |
-- ifOutUcastPkts, ifOutMulticastPkts, |
| 1400 |
-- ifOutBroadcastPkts, ifOutDiscards, |
| 1401 |
-- ifPromiscuousMode } |
| 1402 |
-- STATUS mandatory |
| 1403 |
-- DESCRIPTION |
| 1404 |
-- "A collection of objects providing information specific to |
| 1405 |
-- non-high speed (non-high speed interfaces transmit and |
| 1406 |
-- receive at speeds less than or equal to 20,000,000 |
| 1407 |
-- bits/second) packet-oriented network interfaces." |
| 1408 |
-- ::= { ifGroups 4 } |
| 1409 |
|
| 1410 |
ifHCPacketGroup OBJECT IDENTIFIER |
| 1411 |
::= { ifGroups 5 } |
| 1412 |
|
| 1413 |
-- ifHCPacketGroup OBJECT-GROUP |
| 1414 |
-- OBJECTS { ifHCInOctets, ifHCOutOctets, ifInOctets, |
| 1415 |
-- ifOutOctets, ifInUnknownProtos, ifInErrors, |
| 1416 |
-- ifOutErrors, ifMtu, ifInUcastPkts, |
| 1417 |
-- ifInMulticastPkts, ifInBroadcastPkts, ifInDiscards, |
| 1418 |
-- ifOutUcastPkts, ifOutMulticastPkts, |
| 1419 |
-- ifOutBroadcastPkts, ifOutDiscards, |
| 1420 |
-- ifPromiscuousMode } |
| 1421 |
-- STATUS mandatory |
| 1422 |
-- DESCRIPTION |
| 1423 |
-- "A collection of objects providing information specific to |
| 1424 |
-- high speed (greater than 20,000,000 bits/second but less |
| 1425 |
-- than or equal to 650,000,000 bits/second) packet-oriented |
| 1426 |
-- network interfaces." |
| 1427 |
-- ::= { ifGroups 5 } |
| 1428 |
|
| 1429 |
ifVHCPacketGroup OBJECT IDENTIFIER |
| 1430 |
::= { ifGroups 6 } |
| 1431 |
|
| 1432 |
-- ifVHCPacketGroup OBJECT-GROUP |
| 1433 |
-- OBJECTS { ifHCInUcastPkts, ifHCInMulticastPkts, |
| 1434 |
-- ifHCInBroadcastPkts, ifHCOutUcastPkts, |
| 1435 |
-- ifHCOutMulticastPkts, ifHCOutBroadcastPkts, |
| 1436 |
-- ifHCInOctets, ifHCOutOctets, ifInOctets, |
| 1437 |
-- ifOutOctets, ifInUnknownProtos, ifInErrors, |
| 1438 |
-- ifOutErrors, ifMtu, ifInUcastPkts, |
| 1439 |
-- ifInMulticastPkts, ifInBroadcastPkts, ifInDiscards, |
| 1440 |
-- ifOutUcastPkts, ifOutMulticastPkts, |
| 1441 |
-- ifOutBroadcastPkts, ifOutDiscards, |
| 1442 |
-- ifPromiscuousMode } |
| 1443 |
-- STATUS mandatory |
| 1444 |
-- DESCRIPTION |
| 1445 |
-- "A collection of objects providing information specific to |
| 1446 |
-- higher speed (greater than 650,000,000 bits/second) packet- |
| 1447 |
-- oriented network interfaces." |
| 1448 |
-- ::= { ifGroups 6 } |
| 1449 |
|
| 1450 |
ifRcvAddressGroup OBJECT IDENTIFIER |
| 1451 |
::= { ifGroups 7 } |
| 1452 |
|
| 1453 |
-- ifRcvAddressGroup OBJECT-GROUP |
| 1454 |
-- OBJECTS { ifRcvAddressStatus, ifRcvAddressType } |
| 1455 |
-- STATUS mandatory |
| 1456 |
-- DESCRIPTION |
| 1457 |
-- "A collection of objects providing information on the |
| 1458 |
-- multiple addresses which an interface receives." |
| 1459 |
-- ::= { ifGroups 7 } |
| 1460 |
|
| 1461 |
ifTestGroup OBJECT IDENTIFIER |
| 1462 |
::= { ifGroups 8 } |
| 1463 |
|
| 1464 |
-- ifTestGroup OBJECT-GROUP |
| 1465 |
-- OBJECTS { ifTestId, ifTestStatus, ifTestType, ifTestResult, |
| 1466 |
-- ifTestCode, ifTestOwner } |
| 1467 |
-- STATUS deprecated |
| 1468 |
-- DESCRIPTION |
| 1469 |
-- "A collection of objects providing the ability to invoke |
| 1470 |
-- tests on an interface." |
| 1471 |
-- ::= { ifGroups 8 } |
| 1472 |
|
| 1473 |
ifStackGroup OBJECT IDENTIFIER |
| 1474 |
::= { ifGroups 9 } |
| 1475 |
|
| 1476 |
-- ifStackGroup OBJECT-GROUP |
| 1477 |
-- OBJECTS { ifStackStatus } |
| 1478 |
-- STATUS deprecated |
| 1479 |
-- DESCRIPTION |
| 1480 |
-- "The previous collection of objects providing information on |
| 1481 |
-- the layering of MIB-II interfaces." |
| 1482 |
-- ::= { ifGroups 9 } |
| 1483 |
|
| 1484 |
ifGeneralInformationGroup OBJECT IDENTIFIER |
| 1485 |
::= { ifGroups 10 } |
| 1486 |
|
| 1487 |
-- ifGeneralInformationGroup OBJECT-GROUP |
| 1488 |
-- OBJECTS { ifIndex, ifDescr, ifType, ifSpeed, ifPhysAddress, |
| 1489 |
-- ifAdminStatus, ifOperStatus, ifLastChange, |
| 1490 |
-- ifLinkUpDownTrapEnable, ifConnectorPresent, |
| 1491 |
-- ifHighSpeed, ifName, ifNumber, ifAlias, |
| 1492 |
-- ifTableLastChange } |
| 1493 |
-- STATUS mandatory |
| 1494 |
-- DESCRIPTION |
| 1495 |
-- "A collection of objects providing information applicable to |
| 1496 |
-- all network interfaces." |
| 1497 |
-- ::= { ifGroups 10 } |
| 1498 |
|
| 1499 |
ifStackGroup2 OBJECT IDENTIFIER |
| 1500 |
::= { ifGroups 11 } |
| 1501 |
|
| 1502 |
-- ifStackGroup2 OBJECT-GROUP |
| 1503 |
-- OBJECTS { ifStackStatus, ifStackLastChange } |
| 1504 |
-- STATUS mandatory |
| 1505 |
-- DESCRIPTION |
| 1506 |
-- "A collection of objects providing information on the |
| 1507 |
-- layering of MIB-II interfaces." |
| 1508 |
-- ::= { ifGroups 11 } |
| 1509 |
|
| 1510 |
ifOldObjectsGroup OBJECT IDENTIFIER |
| 1511 |
::= { ifGroups 12 } |
| 1512 |
|
| 1513 |
-- ifOldObjectsGroup OBJECT-GROUP |
| 1514 |
-- OBJECTS { ifInNUcastPkts, ifOutNUcastPkts, ifOutQLen, |
| 1515 |
-- ifSpecific } |
| 1516 |
-- STATUS deprecated |
| 1517 |
-- DESCRIPTION |
| 1518 |
-- "The collection of objects deprecated from the original MIB- |
| 1519 |
-- II interfaces group." |
| 1520 |
-- ::= { ifGroups 12 } |
| 1521 |
|
| 1522 |
ifCounterDiscontinuityGroup OBJECT IDENTIFIER |
| 1523 |
::= { ifGroups 13 } |
| 1524 |
|
| 1525 |
-- ifCounterDiscontinuityGroup OBJECT-GROUP |
| 1526 |
-- OBJECTS { ifCounterDiscontinuityTime } |
| 1527 |
-- STATUS mandatory |
| 1528 |
-- DESCRIPTION |
| 1529 |
-- "A collection of objects providing information specific to |
| 1530 |
-- interface counter discontinuities." |
| 1531 |
-- ::= { ifGroups 13 } |
| 1532 |
|
| 1533 |
linkUpDownNotificationsGroup OBJECT IDENTIFIER |
| 1534 |
::= { ifGroups 14 } |
| 1535 |
|
| 1536 |
-- linkUpDownNotificationsGroup NOTIFICATION-GROUP |
| 1537 |
-- NOTIFICATIONS { linkUp, linkDown } |
| 1538 |
-- STATUS mandatory |
| 1539 |
-- DESCRIPTION |
| 1540 |
-- "The notifications which indicate specific changes in the |
| 1541 |
-- value of ifOperStatus." |
| 1542 |
-- ::= { ifGroups 14 } |
| 1543 |
|
| 1544 |
ifCompliance OBJECT IDENTIFIER |
| 1545 |
::= { ifCompliances 1 } |
| 1546 |
|
| 1547 |
-- ifCompliance MODULE-COMPLIANCE |
| 1548 |
-- STATUS deprecated |
| 1549 |
-- DESCRIPTION |
| 1550 |
-- "A compliance statement defined in a previous version of |
| 1551 |
-- this MIB module, for SNMP entities which have network |
| 1552 |
-- interfaces." |
| 1553 |
|
| 1554 |
-- MODULE -- -- this module |
| 1555 |
|
| 1556 |
-- MANDATORY-GROUPS { ifGeneralGroup, ifStackGroup } |
| 1557 |
|
| 1558 |
-- GROUP ifFixedLengthGroup |
| 1559 |
-- DESCRIPTION |
| 1560 |
-- "This group is mandatory for all network interfaces which |
| 1561 |
-- are character-oriented or transmit data in fixed-length |
| 1562 |
-- transmission units." |
| 1563 |
|
| 1564 |
-- GROUP ifHCFixedLengthGroup |
| 1565 |
-- DESCRIPTION |
| 1566 |
-- "This group is mandatory only for those network interfaces |
| 1567 |
-- which are character-oriented or transmit data in fixed- |
| 1568 |
-- length transmission units, and for which the value of the |
| 1569 |
-- corresponding instance of ifSpeed is greater than 20,000,000 |
| 1570 |
-- bits/second." |
| 1571 |
|
| 1572 |
-- GROUP ifPacketGroup |
| 1573 |
-- DESCRIPTION |
| 1574 |
-- "This group is mandatory for all network interfaces which |
| 1575 |
-- are packet-oriented." |
| 1576 |
|
| 1577 |
-- GROUP ifHCPacketGroup |
| 1578 |
-- DESCRIPTION |
| 1579 |
-- "This group is mandatory only for those network interfaces |
| 1580 |
-- which are packet-oriented and for which the value of the |
| 1581 |
-- corresponding instance of ifSpeed is greater than |
| 1582 |
-- 650,000,000 bits/second." |
| 1583 |
|
| 1584 |
-- GROUP ifTestGroup |
| 1585 |
-- DESCRIPTION |
| 1586 |
-- "This group is optional. Media-specific MIBs which require |
| 1587 |
-- interface tests are strongly encouraged to use this group |
| 1588 |
-- for invoking tests and reporting results. A medium specific |
| 1589 |
-- MIB which has mandatory tests may make implementation of |
| 1590 |
-- |
| 1591 |
-- |
| 1592 |
-- this group mandatory." |
| 1593 |
|
| 1594 |
-- GROUP ifRcvAddressGroup |
| 1595 |
-- DESCRIPTION |
| 1596 |
-- "The applicability of this group MUST be defined by the |
| 1597 |
-- media-specific MIBs. Media-specific MIBs must define the |
| 1598 |
-- exact meaning, use, and semantics of the addresses in this |
| 1599 |
-- group." |
| 1600 |
|
| 1601 |
-- OBJECT ifLinkUpDownTrapEnable |
| 1602 |
-- MIN-ACCESS read-only |
| 1603 |
-- DESCRIPTION |
| 1604 |
-- "Write access is not required." |
| 1605 |
|
| 1606 |
-- OBJECT ifPromiscuousMode |
| 1607 |
-- MIN-ACCESS read-only |
| 1608 |
-- DESCRIPTION |
| 1609 |
-- "Write access is not required." |
| 1610 |
|
| 1611 |
-- OBJECT ifStackStatus |
| 1612 |
-- SYNTAX RowStatus |
| 1613 |
-- { active(1) } |
| 1614 |
-- MIN-ACCESS read-only |
| 1615 |
-- DESCRIPTION |
| 1616 |
-- "Write access is not required, and only one of the six |
| 1617 |
-- enumerated values for the RowStatus textual convention need |
| 1618 |
-- be supported, specifically: active(1)." |
| 1619 |
|
| 1620 |
-- OBJECT ifAdminStatus |
| 1621 |
-- SYNTAX INTEGER |
| 1622 |
-- { up(1), down(2) } |
| 1623 |
-- MIN-ACCESS read-only |
| 1624 |
-- DESCRIPTION |
| 1625 |
-- "Write access is not required, nor is support for the value |
| 1626 |
-- testing(3)." |
| 1627 |
|
| 1628 |
-- ::= { ifCompliances 1 } |
| 1629 |
|
| 1630 |
ifCompliance2 OBJECT IDENTIFIER |
| 1631 |
::= { ifCompliances 2 } |
| 1632 |
|
| 1633 |
-- ifCompliance2 MODULE-COMPLIANCE |
| 1634 |
-- STATUS deprecated |
| 1635 |
-- DESCRIPTION |
| 1636 |
-- "A compliance statement defined in a previous version of |
| 1637 |
-- this MIB module, for SNMP entities which have network |
| 1638 |
-- interfaces." |
| 1639 |
|
| 1640 |
-- MODULE -- -- this module |
| 1641 |
|
| 1642 |
-- MANDATORY-GROUPS { ifGeneralInformationGroup, |
| 1643 |
-- ifStackGroup2, ifCounterDiscontinuityGroup } |
| 1644 |
|
| 1645 |
-- GROUP ifFixedLengthGroup |
| 1646 |
-- DESCRIPTION |
| 1647 |
-- "This group is mandatory for all network interfaces which |
| 1648 |
-- are character-oriented or transmit data in fixed-length |
| 1649 |
-- transmission units." |
| 1650 |
|
| 1651 |
-- GROUP ifHCFixedLengthGroup |
| 1652 |
-- DESCRIPTION |
| 1653 |
-- "This group is mandatory only for those network interfaces |
| 1654 |
-- which are character-oriented or transmit data in fixed- |
| 1655 |
-- length transmission units, and for which the value of the |
| 1656 |
-- corresponding instance of ifSpeed is greater than 20,000,000 |
| 1657 |
-- bits/second." |
| 1658 |
|
| 1659 |
-- GROUP ifPacketGroup |
| 1660 |
-- DESCRIPTION |
| 1661 |
-- "This group is mandatory for all network interfaces which |
| 1662 |
-- are packet-oriented." |
| 1663 |
|
| 1664 |
-- GROUP ifHCPacketGroup |
| 1665 |
-- DESCRIPTION |
| 1666 |
-- "This group is mandatory only for those network interfaces |
| 1667 |
-- which are packet-oriented and for which the value of the |
| 1668 |
-- corresponding instance of ifSpeed is greater than |
| 1669 |
-- 650,000,000 bits/second." |
| 1670 |
|
| 1671 |
-- GROUP ifRcvAddressGroup |
| 1672 |
-- DESCRIPTION |
| 1673 |
-- "The applicability of this group MUST be defined by the |
| 1674 |
-- media-specific MIBs. Media-specific MIBs must define the |
| 1675 |
-- exact meaning, use, and semantics of the addresses in this |
| 1676 |
-- group." |
| 1677 |
|
| 1678 |
-- OBJECT ifLinkUpDownTrapEnable |
| 1679 |
-- MIN-ACCESS read-only |
| 1680 |
-- DESCRIPTION |
| 1681 |
-- "Write access is not required." |
| 1682 |
|
| 1683 |
-- OBJECT ifPromiscuousMode |
| 1684 |
-- MIN-ACCESS read-only |
| 1685 |
-- DESCRIPTION |
| 1686 |
-- "Write access is not required." |
| 1687 |
|
| 1688 |
-- OBJECT ifStackStatus |
| 1689 |
-- SYNTAX RowStatus |
| 1690 |
-- { active(1) } |
| 1691 |
-- MIN-ACCESS read-only |
| 1692 |
-- DESCRIPTION |
| 1693 |
-- "Write access is not required, and only one of the six |
| 1694 |
-- enumerated values for the RowStatus textual convention need |
| 1695 |
-- be supported, specifically: active(1)." |
| 1696 |
|
| 1697 |
-- OBJECT ifAdminStatus |
| 1698 |
-- SYNTAX INTEGER |
| 1699 |
-- { up(1), down(2) } |
| 1700 |
-- MIN-ACCESS read-only |
| 1701 |
-- DESCRIPTION |
| 1702 |
-- "Write access is not required, nor is support for the value |
| 1703 |
-- testing(3)." |
| 1704 |
|
| 1705 |
-- OBJECT ifAlias |
| 1706 |
-- MIN-ACCESS read-only |
| 1707 |
-- DESCRIPTION |
| 1708 |
-- "Write access is not required." |
| 1709 |
|
| 1710 |
-- ::= { ifCompliances 2 } |
| 1711 |
|
| 1712 |
ifCompliance3 OBJECT IDENTIFIER |
| 1713 |
::= { ifCompliances 3 } |
| 1714 |
|
| 1715 |
-- ifCompliance3 MODULE-COMPLIANCE |
| 1716 |
-- STATUS mandatory |
| 1717 |
-- DESCRIPTION |
| 1718 |
-- "The compliance statement for SNMP entities which have |
| 1719 |
-- network interfaces." |
| 1720 |
|
| 1721 |
-- MODULE -- -- this module |
| 1722 |
|
| 1723 |
-- MANDATORY-GROUPS { ifGeneralInformationGroup, |
| 1724 |
-- linkUpDownNotificationsGroup } |
| 1725 |
|
| 1726 |
-- GROUP ifFixedLengthGroup |
| 1727 |
-- DESCRIPTION |
| 1728 |
-- "This group is mandatory for those network interfaces which |
| 1729 |
-- are character-oriented or transmit data in fixed-length |
| 1730 |
-- transmission units, and for which the value of the |
| 1731 |
-- corresponding instance of ifSpeed is less than or equal to |
| 1732 |
-- 20,000,000 bits/second." |
| 1733 |
|
| 1734 |
-- GROUP ifHCFixedLengthGroup |
| 1735 |
-- DESCRIPTION |
| 1736 |
-- "This group is mandatory for those network interfaces which |
| 1737 |
-- are character-oriented or transmit data in fixed-length |
| 1738 |
-- transmission units, and for which the value of the |
| 1739 |
-- corresponding instance of ifSpeed is greater than 20,000,000 |
| 1740 |
-- bits/second." |
| 1741 |
|
| 1742 |
-- GROUP ifPacketGroup |
| 1743 |
-- DESCRIPTION |
| 1744 |
-- "This group is mandatory for those network interfaces which |
| 1745 |
-- are packet-oriented, and for which the value of the |
| 1746 |
-- corresponding instance of ifSpeed is less than or equal to |
| 1747 |
-- 20,000,000 bits/second." |
| 1748 |
|
| 1749 |
-- GROUP ifHCPacketGroup |
| 1750 |
-- DESCRIPTION |
| 1751 |
-- "This group is mandatory only for those network interfaces |
| 1752 |
-- which are packet-oriented and for which the value of the |
| 1753 |
-- corresponding instance of ifSpeed is greater than 20,000,000 |
| 1754 |
-- bits/second but less than or equal to 650,000,000 |
| 1755 |
-- bits/second." |
| 1756 |
|
| 1757 |
-- GROUP ifVHCPacketGroup |
| 1758 |
-- DESCRIPTION |
| 1759 |
-- "This group is mandatory only for those network interfaces |
| 1760 |
-- which are packet-oriented and for which the value of the |
| 1761 |
-- corresponding instance of ifSpeed is greater than |
| 1762 |
-- 650,000,000 bits/second." |
| 1763 |
|
| 1764 |
-- GROUP ifCounterDiscontinuityGroup |
| 1765 |
-- DESCRIPTION |
| 1766 |
-- "This group is mandatory for those network interfaces that |
| 1767 |
-- are required to maintain counters (i.e., those for which one |
| 1768 |
-- of the ifFixedLengthGroup, ifHCFixedLengthGroup, |
| 1769 |
-- ifPacketGroup, ifHCPacketGroup, or ifVHCPacketGroup is |
| 1770 |
-- mandatory)." |
| 1771 |
|
| 1772 |
-- GROUP ifRcvAddressGroup |
| 1773 |
-- DESCRIPTION |
| 1774 |
-- "The applicability of this group MUST be defined by the |
| 1775 |
-- media-specific MIBs. Media-specific MIBs must define the |
| 1776 |
-- exact meaning, use, and semantics of the addresses in this |
| 1777 |
-- group." |
| 1778 |
|
| 1779 |
-- OBJECT ifLinkUpDownTrapEnable |
| 1780 |
-- MIN-ACCESS read-only |
| 1781 |
-- DESCRIPTION |
| 1782 |
-- "Write access is not required." |
| 1783 |
|
| 1784 |
-- OBJECT ifPromiscuousMode |
| 1785 |
-- MIN-ACCESS read-only |
| 1786 |
-- DESCRIPTION |
| 1787 |
-- "Write access is not required." |
| 1788 |
|
| 1789 |
-- OBJECT ifAdminStatus |
| 1790 |
-- SYNTAX INTEGER |
| 1791 |
-- { up(1), down(2) } |
| 1792 |
-- MIN-ACCESS read-only |
| 1793 |
-- DESCRIPTION |
| 1794 |
-- "Write access is not required, nor is support for the value |
| 1795 |
-- testing(3)." |
| 1796 |
|
| 1797 |
-- OBJECT ifAlias |
| 1798 |
-- MIN-ACCESS read-only |
| 1799 |
-- DESCRIPTION |
| 1800 |
-- "Write access is not required." |
| 1801 |
|
| 1802 |
-- ::= { ifCompliances 3 } |
| 1803 |
|
| 1804 |
END -- end of module IF-MIB. |