Debian Codegraph @

Modules/ThirdParty/VNL/src/vxl/v3p/netlib/opt/lbfgs.f

raw
1 C ----------------------------------------------------------------------
2 C This file contains the LBFGS algorithm and supporting routines
3 C
4 C ****************
5 C LBFGS SUBROUTINE
6 C ****************
7 C
8 SUBROUTINE LBFGS(N,M,X,F,G,DIAGCO,DIAG,IPRINT,EPS,XTOL,W,IFLAG)
9 C
10 INTEGER N,M,IPRINT(2),IFLAG
11 DOUBLE PRECISION X(N),G(N),DIAG(N),W(N*(2*M+1)+2*M)
12 DOUBLE PRECISION F,EPS,XTOL
13 LOGICAL DIAGCO
14 C
15 C LIMITED MEMORY BFGS METHOD FOR LARGE SCALE OPTIMIZATION
16 C JORGE NOCEDAL
17 C *** July 1990 ***
18 C
19 C
20 C This subroutine solves the unconstrained minimization problem
21 C
22 C min F(x), x= (x1,x2,...,xN),
23 C
24 C using the limited memory BFGS method. The routine is especially
25 C effective on problems involving a large number of variables. In
26 C a typical iteration of this method an approximation Hk to the
27 C inverse of the Hessian is obtained by applying M BFGS updates to
28 C a diagonal matrix Hk0, using information from the previous M steps.
29 C The user specifies the number M, which determines the amount of
30 C storage required by the routine. The user may also provide the
31 C diagonal matrices Hk0 if not satisfied with the default choice.
32 C The algorithm is described in "On the limited memory BFGS method
33 C for large scale optimization", by D. Liu and J. Nocedal,
34 C Mathematical Programming B 45 (1989) 503-528.
35 C
36 C The user is required to calculate the function value F and its
37 C gradient G. In order to allow the user complete control over
38 C these computations, reverse communication is used. The routine
39 C must be called repeatedly under the control of the parameter
40 C IFLAG.
41 C
42 C The steplength is determined at each iteration by means of the
43 C line search routine MCVSRCH, which is a slight modification of
44 C the routine CSRCH written by More' and Thuente.
45 C
46 C The calling statement is
47 C
48 C CALL LBFGS(N,M,X,F,G,DIAGCO,DIAG,IPRINT,EPS,XTOL,W,IFLAG)
49 C
50 C where
51 C
52 C N is an INTEGER variable that must be set by the user to the
53 C number of variables. It is not altered by the routine.
54 C Restriction: N>0.
55 C
56 C M is an INTEGER variable that must be set by the user to
57 C the number of corrections used in the BFGS update. It
58 C is not altered by the routine. Values of M less than 3 are
59 C not recommended; large values of M will result in excessive
60 C computing time. 3<= M <=7 is recommended. Restriction: M>0.
61 C
62 C X is a DOUBLE PRECISION array of length N. On initial entry
63 C it must be set by the user to the values of the initial
64 C estimate of the solution vector. On exit with IFLAG=0, it
65 C contains the values of the variables at the best point
66 C found (usually a solution).
67 C
68 C F is a DOUBLE PRECISION variable. Before initial entry and on
69 C a re-entry with IFLAG=1, it must be set by the user to
70 C contain the value of the function F at the point X.
71 C
72 C G is a DOUBLE PRECISION array of length N. Before initial
73 C entry and on a re-entry with IFLAG=1, it must be set by
74 C the user to contain the components of the gradient G at
75 C the point X.
76 C
77 C DIAGCO is a LOGICAL variable that must be set to .TRUE. if the
78 C user wishes to provide the diagonal matrix Hk0 at each
79 C iteration. Otherwise it should be set to .FALSE., in which
80 C case LBFGS will use a default value described below. If
81 C DIAGCO is set to .TRUE. the routine will return at each
82 C iteration of the algorithm with IFLAG=2, and the diagonal
83 C matrix Hk0 must be provided in the array DIAG.
84 C
85 C
86 C DIAG is a DOUBLE PRECISION array of length N. If DIAGCO=.TRUE.,
87 C then on initial entry or on re-entry with IFLAG=2, DIAG
88 C it must be set by the user to contain the values of the
89 C diagonal matrix Hk0. Restriction: all elements of DIAG
90 C must be positive.
91 C
92 C IPRINT is an INTEGER array of length two which must be set by the
93 C user.
94 C
95 C IPRINT(1) specifies the frequency of the output:
96 C IPRINT(1) < 0 : no output is generated,
97 C IPRINT(1) = 0 : output only at first and last iteration,
98 C IPRINT(1) > 0 : output every IPRINT(1) iterations.
99 C
100 C IPRINT(2) specifies the type of output generated:
101 C IPRINT(2) = 0 : iteration count, number of function
102 C evaluations, function value, norm of the
103 C gradient, and steplength,
104 C IPRINT(2) = 1 : same as IPRINT(2)=0, plus vector of
105 C variables and gradient vector at the
106 C initial point,
107 C IPRINT(2) = 2 : same as IPRINT(2)=1, plus vector of
108 C variables,
109 C IPRINT(2) = 3 : same as IPRINT(2)=2, plus gradient vector.
110 C
111 C
112 C EPS is a positive DOUBLE PRECISION variable that must be set by
113 C the user, and determines the accuracy with which the solution
114 C is to be found. The subroutine terminates when
115 C
116 C ||G|| < EPS max(1,||X||),
117 C
118 C where ||.|| denotes the Euclidean norm.
119 C
120 C XTOL is a positive DOUBLE PRECISION variable that must be set by
121 C the user to an estimate of the machine precision (e.g.
122 C 10**(-16) on a SUN station 3/60). The line search routine will
123 C terminate if the relative width of the interval of uncertainty
124 C is less than XTOL.
125 C
126 C W is a DOUBLE PRECISION array of length N(2M+1)+2M used as
127 C workspace for LBFGS. This array must not be altered by the
128 C user.
129 C
130 C IFLAG is an INTEGER variable that must be set to 0 on initial entry
131 C to the subroutine. A return with IFLAG<0 indicates an error,
132 C and IFLAG=0 indicates that the routine has terminated without
133 C detecting errors. On a return with IFLAG=1, the user must
134 C evaluate the function F and gradient G. On a return with
135 C IFLAG=2, the user must provide the diagonal matrix Hk0.
136 C
137 C The following negative values of IFLAG, detecting an error,
138 C are possible:
139 C
140 C IFLAG=-1 The line search routine MCSRCH failed. The
141 C parameter INFO provides more detailed information
142 C (see also the documentation of MCSRCH):
143 C
144 C INFO = 0 IMPROPER INPUT PARAMETERS.
145 C
146 C INFO = 2 RELATIVE WIDTH OF THE INTERVAL OF
147 C UNCERTAINTY IS AT MOST XTOL.
148 C
149 C INFO = 3 MORE THAN 20 FUNCTION EVALUATIONS WERE
150 C REQUIRED AT THE PRESENT ITERATION.
151 C
152 C INFO = 4 THE STEP IS TOO SMALL.
153 C
154 C INFO = 5 THE STEP IS TOO LARGE.
155 C
156 C INFO = 6 ROUNDING ERRORS PREVENT FURTHER PROGRESS.
157 C THERE MAY NOT BE A STEP WHICH SATISFIES
158 C THE SUFFICIENT DECREASE AND CURVATURE
159 C CONDITIONS. TOLERANCES MAY BE TOO SMALL.
160 C
161 C
162 C IFLAG=-2 The i-th diagonal element of the diagonal inverse
163 C Hessian approximation, given in DIAG, is not
164 C positive.
165 C
166 C IFLAG=-3 Improper input parameters for LBFGS (N or M are
167 C not positive).
168 C
169 C
170 C
171 C ON THE DRIVER:
172 C
173 C The program that calls LBFGS must contain the declaration:
174 C
175 C EXTERNAL LB2
176 C
177 C LB2 is a BLOCK DATA that defines the default values of several
178 C parameters described in the COMMON section.
179 C
180 C
181 C
182 C COMMON:
183 C
184 C The subroutine contains one common area, which the user may wish to
185 C reference:
186 C
187 COMMON /LB3/MP,LP,GTOL,STPMIN,STPMAX
188 C
189 C MP is an INTEGER variable with default value 6. It is used as the
190 C unit number for the printing of the monitoring information
191 C controlled by IPRINT.
192 C
193 C LP is an INTEGER variable with default value 6. It is used as the
194 C unit number for the printing of error messages. This printing
195 C may be suppressed by setting LP to a non-positive value.
196 C
197 C GTOL is a DOUBLE PRECISION variable with default value 0.9, which
198 C controls the accuracy of the line search routine MCSRCH. If the
199 C function and gradient evaluations are inexpensive with respect
200 C to the cost of the iteration (which is sometimes the case when
201 C solving very large problems) it may be advantageous to set GTOL
202 C to a small value. A typical small value is 0.1. Restriction:
203 C GTOL should be greater than 1.D-04.
204 C
205 C STPMIN and STPMAX are non-negative DOUBLE PRECISION variables which
206 C specify lower and uper bounds for the step in the line search.
207 C Their default values are 1.D-20 and 1.D+20, respectively. These
208 C values need not be modified unless the exponents are too large
209 C for the machine being used, or unless the problem is extremely
210 C badly scaled (in which case the exponents should be increased).
211 C
212 C
213 C MACHINE DEPENDENCIES
214 C
215 C The only variables that are machine-dependent are XTOL,
216 C STPMIN and STPMAX.
217 C
218 C
219 C GENERAL INFORMATION
220 C
221 C Other routines called directly: DAXPY, DDOT, LB1, MCSRCH
222 C
223 C Input/Output : No input; diagnostic messages on unit MP and
224 C error messages on unit LP.
225 C
226 C
227 C - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
228 C
229 DOUBLE PRECISION GTOL,ONE,ZERO,GNORM,DDOT,STP1,FTOL,STPMIN,
230 . STPMAX,STP,YS,YY,SQ,YR,BETA,XNORM
231 INTEGER MP,LP,ITER,NFUN,POINT,ISPT,IYPT,MAXFEV,INFO,
232 . BOUND,NPT,CP,I,NFEV,INMC,IYCN,ISCN
233 LOGICAL FINISH
234 C
235 SAVE
236 DATA ONE,ZERO/1.0D+0,0.0D+0/
237 C
238 C INITIALIZE
239 C ----------
240 C
241 IF(IFLAG.EQ.0) GO TO 10
242 GO TO (172,100) IFLAG
243 10 ITER= 0
244 IF(N.LE.0.OR.M.LE.0) GO TO 196
245 IF(GTOL.LE.1.D-04) THEN
246 IF(LP.GT.0) WRITE(LP,245)
247 GTOL=9.D-01
248 ENDIF
249 NFUN= 1
250 POINT= 0
251 FINISH= .FALSE.
252 IF(DIAGCO) THEN
253 DO 30 I=1,N
254 30 IF (DIAG(I).LE.ZERO) GO TO 195
255 ELSE
256 DO 40 I=1,N
257 40 DIAG(I)= 1.0D0
258 ENDIF
259 C
260 C THE WORK VECTOR W IS DIVIDED AS FOLLOWS:
261 C ---------------------------------------
262 C THE FIRST N LOCATIONS ARE USED TO STORE THE GRADIENT AND
263 C OTHER TEMPORARY INFORMATION.
264 C LOCATIONS (N+1)...(N+M) STORE THE SCALARS RHO.
265 C LOCATIONS (N+M+1)...(N+2M) STORE THE NUMBERS ALPHA USED
266 C IN THE FORMULA THAT COMPUTES H*G.
267 C LOCATIONS (N+2M+1)...(N+2M+NM) STORE THE LAST M SEARCH
268 C STEPS.
269 C LOCATIONS (N+2M+NM+1)...(N+2M+2NM) STORE THE LAST M
270 C GRADIENT DIFFERENCES.
271 C
272 C THE SEARCH STEPS AND GRADIENT DIFFERENCES ARE STORED IN A
273 C CIRCULAR ORDER CONTROLLED BY THE PARAMETER POINT.
274 C
275 ISPT= N+2*M
276 IYPT= ISPT+N*M
277 DO 50 I=1,N
278 50 W(ISPT+I)= -G(I)*DIAG(I)
279 GNORM= DSQRT(DDOT(N,G,1,G,1))
280 STP1= ONE/GNORM
281 C
282 C PARAMETERS FOR LINE SEARCH ROUTINE
283 C
284 FTOL= 1.0D-4
285 MAXFEV= 20
286 C
287 IF(IPRINT(1).GE.0) CALL LB1(IPRINT,ITER,NFUN,
288 * GNORM,N,M,X,F,G,STP,FINISH)
289 C
290 C --------------------
291 C MAIN ITERATION LOOP
292 C --------------------
293 C
294 80 ITER= ITER+1
295 INFO=0
296 BOUND=ITER-1
297 IF(ITER.EQ.1) GO TO 165
298 IF (ITER .GT. M)BOUND=M
299 C
300 YS= DDOT(N,W(IYPT+NPT+1),1,W(ISPT+NPT+1),1)
301 IF(.NOT.DIAGCO) THEN
302 YY= DDOT(N,W(IYPT+NPT+1),1,W(IYPT+NPT+1),1)
303 DO 90 I=1,N
304 90 DIAG(I)= YS/YY
305 ELSE
306 IFLAG=2
307 RETURN
308 ENDIF
309 100 CONTINUE
310 IF(DIAGCO) THEN
311 DO 110 I=1,N
312 110 IF (DIAG(I).LE.ZERO) GO TO 195
313 ENDIF
314 C
315 C COMPUTE -H*G USING THE FORMULA GIVEN IN: Nocedal, J. 1980,
316 C "Updating quasi-Newton matrices with limited storage",
317 C Mathematics of Computation, Vol.24, No.151, pp. 773-782.
318 C ---------------------------------------------------------
319 C
320 CP= POINT
321 IF (POINT.EQ.0) CP=M
322 W(N+CP)= ONE/YS
323 DO 112 I=1,N
324 112 W(I)= -G(I)
325 CP= POINT
326 DO 125 I= 1,BOUND
327 CP=CP-1
328 IF (CP.EQ. -1)CP=M-1
329 SQ= DDOT(N,W(ISPT+CP*N+1),1,W,1)
330 INMC=N+M+CP+1
331 IYCN=IYPT+CP*N
332 W(INMC)= W(N+CP+1)*SQ
333 CALL DAXPY(N,-W(INMC),W(IYCN+1),1,W,1)
334 125 CONTINUE
335 C
336 DO 130 I=1,N
337 130 W(I)=DIAG(I)*W(I)
338 C
339 DO 145 I=1,BOUND
340 YR= DDOT(N,W(IYPT+CP*N+1),1,W,1)
341 BETA= W(N+CP+1)*YR
342 INMC=N+M+CP+1
343 BETA= W(INMC)-BETA
344 ISCN=ISPT+CP*N
345 CALL DAXPY(N,BETA,W(ISCN+1),1,W,1)
346 CP=CP+1
347 IF (CP.EQ.M)CP=0
348 145 CONTINUE
349 C
350 C STORE THE NEW SEARCH DIRECTION
351 C ------------------------------
352 C
353 DO 160 I=1,N
354 160 W(ISPT+POINT*N+I)= W(I)
355 C
356 C OBTAIN THE ONE-DIMENSIONAL MINIMIZER OF THE FUNCTION
357 C BY USING THE LINE SEARCH ROUTINE MCSRCH
358 C ----------------------------------------------------
359 165 NFEV=0
360 STP=ONE
361 IF (ITER.EQ.1) STP=STP1
362 DO 170 I=1,N
363 170 W(I)=G(I)
364 172 CONTINUE
365 CALL MCSRCH(N,X,F,G,W(ISPT+POINT*N+1),STP,FTOL,
366 * XTOL,MAXFEV,INFO,NFEV,DIAG)
367 IF (INFO .EQ. -1) THEN
368 IFLAG=1
369 RETURN
370 ENDIF
371 IF (INFO .NE. 1) GO TO 190
372 NFUN= NFUN + NFEV
373 C
374 C COMPUTE THE NEW STEP AND GRADIENT CHANGE
375 C -----------------------------------------
376 C
377 NPT=POINT*N
378 DO 175 I=1,N
379 W(ISPT+NPT+I)= STP*W(ISPT+NPT+I)
380 175 W(IYPT+NPT+I)= G(I)-W(I)
381 POINT=POINT+1
382 IF (POINT.EQ.M)POINT=0
383 C
384 C TERMINATION TEST
385 C ----------------
386 C
387 GNORM= DSQRT(DDOT(N,G,1,G,1))
388 XNORM= DSQRT(DDOT(N,X,1,X,1))
389 XNORM= DMAX1(1.0D0,XNORM)
390 IF (GNORM/XNORM .LE. EPS) FINISH=.TRUE.
391 C
392 IF(IPRINT(1).GE.0) CALL LB1(IPRINT,ITER,NFUN,
393 * GNORM,N,M,X,F,G,STP,FINISH)
394 IF (FINISH) THEN
395 IFLAG=0
396 RETURN
397 ENDIF
398 GO TO 80
399 C
400 C ------------------------------------------------------------
401 C END OF MAIN ITERATION LOOP. ERROR EXITS.
402 C ------------------------------------------------------------
403 C
404 190 IFLAG=-1
405 IF(LP.GT.0) WRITE(LP,200) INFO
406 RETURN
407 195 IFLAG=-2
408 IF(LP.GT.0) WRITE(LP,235) I
409 RETURN
410 196 IFLAG= -3
411 IF(LP.GT.0) WRITE(LP,240)
412 C
413 C FORMATS
414 C -------
415 C
416 200 FORMAT(/' IFLAG= -1 ',/' LINE SEARCH FAILED. SEE'
417 . ' DOCUMENTATION OF ROUTINE MCSRCH',/' ERROR RETURN'
418 . ' OF LINE SEARCH: INFO= ',I2,/
419 . ' POSSIBLE CAUSES: FUNCTION OR GRADIENT ARE INCORRECT',/,
420 . ' OR INCORRECT TOLERANCES')
421 235 FORMAT(/' IFLAG= -2',/' THE',I5,'-TH DIAGONAL ELEMENT OF THE',/,
422 . ' INVERSE HESSIAN APPROXIMATION IS NOT POSITIVE')
423 240 FORMAT(/' IFLAG= -3',/' IMPROPER INPUT PARAMETERS (N OR M',
424 . ' ARE NOT POSITIVE)')
425 245 FORMAT(/' GTOL IS LESS THAN OR EQUAL TO 1.D-04',
426 . / ' IT HAS BEEN RESET TO 9.D-01')
427 RETURN
428 END
429 C
430 C LAST LINE OF SUBROUTINE LBFGS
431 C
432 C
433 SUBROUTINE LB1(IPRINT,ITER,NFUN,
434 * GNORM,N,M,X,F,G,STP,FINISH)
435 C
436 C -------------------------------------------------------------
437 C THIS ROUTINE PRINTS MONITORING INFORMATION. THE FREQUENCY AND
438 C AMOUNT OF OUTPUT ARE CONTROLLED BY IPRINT.
439 C -------------------------------------------------------------
440 C
441 INTEGER IPRINT(2),ITER,NFUN,LP,MP,N,M
442 DOUBLE PRECISION X(N),G(N),F,GNORM,STP,GTOL,STPMIN,STPMAX
443 LOGICAL FINISH
444 COMMON /LB3/MP,LP,GTOL,STPMIN,STPMAX
445 C
446 IF (ITER.EQ.0)THEN
447 WRITE(MP,10)
448 WRITE(MP,20) N,M
449 WRITE(MP,30)F,GNORM
450 IF (IPRINT(2).GE.1)THEN
451 WRITE(MP,40)
452 WRITE(MP,50) (X(I),I=1,N)
453 WRITE(MP,60)
454 WRITE(MP,50) (G(I),I=1,N)
455 ENDIF
456 WRITE(MP,10)
457 WRITE(MP,70)
458 ELSE
459 IF ((IPRINT(1).EQ.0).AND.(ITER.NE.1.AND..NOT.FINISH))RETURN
460 IF (IPRINT(1).NE.0)THEN
461 IF(MOD(ITER-1,IPRINT(1)).EQ.0.OR.FINISH)THEN
462 IF(IPRINT(2).GT.1.AND.ITER.GT.1) WRITE(MP,70)
463 WRITE(MP,80)ITER,NFUN,F,GNORM,STP
464 ELSE
465 RETURN
466 ENDIF
467 ELSE
468 IF( IPRINT(2).GT.1.AND.FINISH) WRITE(MP,70)
469 WRITE(MP,80)ITER,NFUN,F,GNORM,STP
470 ENDIF
471 IF (IPRINT(2).EQ.2.OR.IPRINT(2).EQ.3)THEN
472 IF (FINISH)THEN
473 WRITE(MP,90)
474 ELSE
475 WRITE(MP,40)
476 ENDIF
477 WRITE(MP,50)(X(I),I=1,N)
478 IF (IPRINT(2).EQ.3)THEN
479 WRITE(MP,60)
480 WRITE(MP,50)(G(I),I=1,N)
481 ENDIF
482 ENDIF
483 IF (FINISH) WRITE(MP,100)
484 ENDIF
485 C
486 10 FORMAT('*************************************************')
487 20 FORMAT(' N=',I5,' NUMBER OF CORRECTIONS=',I2,
488 . /, ' INITIAL VALUES')
489 30 FORMAT(' F= ',1PD10.3,' GNORM= ',1PD10.3)
490 40 FORMAT(' VECTOR X= ')
491 50 FORMAT(6(2X,1PD10.3))
492 60 FORMAT(' GRADIENT VECTOR G= ')
493 70 FORMAT(/' I NFN',4X,'FUNC',8X,'GNORM',7X,'STEPLENGTH'/)
494 80 FORMAT(2(I4,1X),3X,3(1PD10.3,2X))
495 90 FORMAT(' FINAL POINT X= ')
496 100 FORMAT(/' THE MINIMIZATION TERMINATED WITHOUT DETECTING ERRORS.',
497 . /' IFLAG = 0')
498 C
499 RETURN
500 END
501 C ******
502 C
503 C
504 C ----------------------------------------------------------
505 C DATA
506 C ----------------------------------------------------------
507 C
508 BLOCK DATA LB2
509 INTEGER LP,MP
510 DOUBLE PRECISION GTOL,STPMIN,STPMAX
511 COMMON /LB3/MP,LP,GTOL,STPMIN,STPMAX
512 DATA MP,LP,GTOL,STPMIN,STPMAX/6,6,9.0D-01,1.0D-20,1.0D+20/
513 END
514 C ------------------------------------------------------------------
515 C
516 C **************************
517 C LINE SEARCH ROUTINE MCSRCH
518 C **************************
519 C
520 SUBROUTINE MCSRCH(N,X,F,G,S,STP,FTOL,XTOL,MAXFEV,INFO,NFEV,WA)
521 INTEGER N,MAXFEV,INFO,NFEV
522 DOUBLE PRECISION F,STP,FTOL,GTOL,XTOL,STPMIN,STPMAX
523 DOUBLE PRECISION X(N),G(N),S(N),WA(N)
524 COMMON /LB3/MP,LP,GTOL,STPMIN,STPMAX
525 SAVE
526 C
527 C SUBROUTINE MCSRCH
528 C
529 C A slight modification of the subroutine CSRCH of More' and Thuente.
530 C The changes are to allow reverse communication, and do not affect
531 C the performance of the routine.
532 C
533 C THE PURPOSE OF MCSRCH IS TO FIND A STEP WHICH SATISFIES
534 C A SUFFICIENT DECREASE CONDITION AND A CURVATURE CONDITION.
535 C
536 C AT EACH STAGE THE SUBROUTINE UPDATES AN INTERVAL OF
537 C UNCERTAINTY WITH ENDPOINTS STX AND STY. THE INTERVAL OF
538 C UNCERTAINTY IS INITIALLY CHOSEN SO THAT IT CONTAINS A
539 C MINIMIZER OF THE MODIFIED FUNCTION
540 C
541 C F(X+STP*S) - F(X) - FTOL*STP*(GRADF(X)'S).
542 C
543 C IF A STEP IS OBTAINED FOR WHICH THE MODIFIED FUNCTION
544 C HAS A NONPOSITIVE FUNCTION VALUE AND NONNEGATIVE DERIVATIVE,
545 C THEN THE INTERVAL OF UNCERTAINTY IS CHOSEN SO THAT IT
546 C CONTAINS A MINIMIZER OF F(X+STP*S).
547 C
548 C THE ALGORITHM IS DESIGNED TO FIND A STEP WHICH SATISFIES
549 C THE SUFFICIENT DECREASE CONDITION
550 C
551 C F(X+STP*S) .LE. F(X) + FTOL*STP*(GRADF(X)'S),
552 C
553 C AND THE CURVATURE CONDITION
554 C
555 C ABS(GRADF(X+STP*S)'S)) .LE. GTOL*ABS(GRADF(X)'S).
556 C
557 C IF FTOL IS LESS THAN GTOL AND IF, FOR EXAMPLE, THE FUNCTION
558 C IS BOUNDED BELOW, THEN THERE IS ALWAYS A STEP WHICH SATISFIES
559 C BOTH CONDITIONS. IF NO STEP CAN BE FOUND WHICH SATISFIES BOTH
560 C CONDITIONS, THEN THE ALGORITHM USUALLY STOPS WHEN ROUNDING
561 C ERRORS PREVENT FURTHER PROGRESS. IN THIS CASE STP ONLY
562 C SATISFIES THE SUFFICIENT DECREASE CONDITION.
563 C
564 C THE SUBROUTINE STATEMENT IS
565 C
566 C SUBROUTINE MCSRCH(N,X,F,G,S,STP,FTOL,XTOL, MAXFEV,INFO,NFEV,WA)
567 C WHERE
568 C
569 C N IS A POSITIVE INTEGER INPUT VARIABLE SET TO THE NUMBER
570 C OF VARIABLES.
571 C
572 C X IS AN ARRAY OF LENGTH N. ON INPUT IT MUST CONTAIN THE
573 C BASE POINT FOR THE LINE SEARCH. ON OUTPUT IT CONTAINS
574 C X + STP*S.
575 C
576 C F IS A VARIABLE. ON INPUT IT MUST CONTAIN THE VALUE OF F
577 C AT X. ON OUTPUT IT CONTAINS THE VALUE OF F AT X + STP*S.
578 C
579 C G IS AN ARRAY OF LENGTH N. ON INPUT IT MUST CONTAIN THE
580 C GRADIENT OF F AT X. ON OUTPUT IT CONTAINS THE GRADIENT
581 C OF F AT X + STP*S.
582 C
583 C S IS AN INPUT ARRAY OF LENGTH N WHICH SPECIFIES THE
584 C SEARCH DIRECTION.
585 C
586 C STP IS A NONNEGATIVE VARIABLE. ON INPUT STP CONTAINS AN
587 C INITIAL ESTIMATE OF A SATISFACTORY STEP. ON OUTPUT
588 C STP CONTAINS THE FINAL ESTIMATE.
589 C
590 C FTOL AND GTOL ARE NONNEGATIVE INPUT VARIABLES. (In this reverse
591 C communication implementation GTOL is defined in a COMMON
592 C statement.) TERMINATION OCCURS WHEN THE SUFFICIENT DECREASE
593 C CONDITION AND THE DIRECTIONAL DERIVATIVE CONDITION ARE
594 C SATISFIED.
595 C
596 C XTOL IS A NONNEGATIVE INPUT VARIABLE. TERMINATION OCCURS
597 C WHEN THE RELATIVE WIDTH OF THE INTERVAL OF UNCERTAINTY
598 C IS AT MOST XTOL.
599 C
600 C STPMIN AND STPMAX ARE NONNEGATIVE INPUT VARIABLES WHICH
601 C SPECIFY LOWER AND UPPER BOUNDS FOR THE STEP. (In this reverse
602 C communication implementatin they are defined in a COMMON
603 C statement).
604 C
605 C MAXFEV IS A POSITIVE INTEGER INPUT VARIABLE. TERMINATION
606 C OCCURS WHEN THE NUMBER OF CALLS TO FCN IS AT LEAST
607 C MAXFEV BY THE END OF AN ITERATION.
608 C
609 C INFO IS AN INTEGER OUTPUT VARIABLE SET AS FOLLOWS:
610 C
611 C INFO = 0 IMPROPER INPUT PARAMETERS.
612 C
613 C INFO =-1 A RETURN IS MADE TO COMPUTE THE FUNCTION AND GRADIENT.
614 C
615 C INFO = 1 THE SUFFICIENT DECREASE CONDITION AND THE
616 C DIRECTIONAL DERIVATIVE CONDITION HOLD.
617 C
618 C INFO = 2 RELATIVE WIDTH OF THE INTERVAL OF UNCERTAINTY
619 C IS AT MOST XTOL.
620 C
621 C INFO = 3 NUMBER OF CALLS TO FCN HAS REACHED MAXFEV.
622 C
623 C INFO = 4 THE STEP IS AT THE LOWER BOUND STPMIN.
624 C
625 C INFO = 5 THE STEP IS AT THE UPPER BOUND STPMAX.
626 C
627 C INFO = 6 ROUNDING ERRORS PREVENT FURTHER PROGRESS.
628 C THERE MAY NOT BE A STEP WHICH SATISFIES THE
629 C SUFFICIENT DECREASE AND CURVATURE CONDITIONS.
630 C TOLERANCES MAY BE TOO SMALL.
631 C
632 C NFEV IS AN INTEGER OUTPUT VARIABLE SET TO THE NUMBER OF
633 C CALLS TO FCN.
634 C
635 C WA IS A WORK ARRAY OF LENGTH N.
636 C
637 C SUBPROGRAMS CALLED
638 C
639 C MCSTEP
640 C
641 C FORTRAN-SUPPLIED...ABS,MAX,MIN
642 C
643 C ARGONNE NATIONAL LABORATORY. MINPACK PROJECT. JUNE 1983
644 C JORGE J. MORE', DAVID J. THUENTE
645 C
646 C **********
647 INTEGER INFOC,J
648 LOGICAL BRACKT,STAGE1
649 DOUBLE PRECISION DG,DGM,DGINIT,DGTEST,DGX,DGXM,DGY,DGYM,
650 * FINIT,FTEST1,FM,FX,FXM,FY,FYM,P5,P66,STX,STY,
651 * STMIN,STMAX,WIDTH,WIDTH1,XTRAPF,ZERO
652 DATA P5,P66,XTRAPF,ZERO /0.5D0,0.66D0,4.0D0,0.0D0/
653 IF(INFO.EQ.-1) GO TO 45
654 INFOC = 1
655 C
656 C CHECK THE INPUT PARAMETERS FOR ERRORS.
657 C
658 IF (N .LE. 0 .OR. STP .LE. ZERO .OR. FTOL .LT. ZERO .OR.
659 * GTOL .LT. ZERO .OR. XTOL .LT. ZERO .OR. STPMIN .LT. ZERO
660 * .OR. STPMAX .LT. STPMIN .OR. MAXFEV .LE. 0) RETURN
661 C
662 C COMPUTE THE INITIAL GRADIENT IN THE SEARCH DIRECTION
663 C AND CHECK THAT S IS A DESCENT DIRECTION.
664 C
665 DGINIT = ZERO
666 DO 10 J = 1, N
667 DGINIT = DGINIT + G(J)*S(J)
668 10 CONTINUE
669 IF (DGINIT .GE. ZERO) then
670 write(LP,15)
671 15 FORMAT(/' THE SEARCH DIRECTION IS NOT A DESCENT DIRECTION')
672 RETURN
673 ENDIF
674 C
675 C INITIALIZE LOCAL VARIABLES.
676 C
677 BRACKT = .FALSE.
678 STAGE1 = .TRUE.
679 NFEV = 0
680 FINIT = F
681 DGTEST = FTOL*DGINIT
682 WIDTH = STPMAX - STPMIN
683 WIDTH1 = WIDTH/P5
684 DO 20 J = 1, N
685 WA(J) = X(J)
686 20 CONTINUE
687 C
688 C THE VARIABLES STX, FX, DGX CONTAIN THE VALUES OF THE STEP,
689 C FUNCTION, AND DIRECTIONAL DERIVATIVE AT THE BEST STEP.
690 C THE VARIABLES STY, FY, DGY CONTAIN THE VALUE OF THE STEP,
691 C FUNCTION, AND DERIVATIVE AT THE OTHER ENDPOINT OF
692 C THE INTERVAL OF UNCERTAINTY.
693 C THE VARIABLES STP, F, DG CONTAIN THE VALUES OF THE STEP,
694 C FUNCTION, AND DERIVATIVE AT THE CURRENT STEP.
695 C
696 STX = ZERO
697 FX = FINIT
698 DGX = DGINIT
699 STY = ZERO
700 FY = FINIT
701 DGY = DGINIT
702 C
703 C START OF ITERATION.
704 C
705 30 CONTINUE
706 C
707 C SET THE MINIMUM AND MAXIMUM STEPS TO CORRESPOND
708 C TO THE PRESENT INTERVAL OF UNCERTAINTY.
709 C
710 IF (BRACKT) THEN
711 STMIN = MIN(STX,STY)
712 STMAX = MAX(STX,STY)
713 ELSE
714 STMIN = STX
715 STMAX = STP + XTRAPF*(STP - STX)
716 END IF
717 C
718 C FORCE THE STEP TO BE WITHIN THE BOUNDS STPMAX AND STPMIN.
719 C
720 STP = MAX(STP,STPMIN)
721 STP = MIN(STP,STPMAX)
722 C
723 C IF AN UNUSUAL TERMINATION IS TO OCCUR THEN LET
724 C STP BE THE LOWEST POINT OBTAINED SO FAR.
725 C
726 IF ((BRACKT .AND. (STP .LE. STMIN .OR. STP .GE. STMAX))
727 * .OR. NFEV .GE. MAXFEV-1 .OR. INFOC .EQ. 0
728 * .OR. (BRACKT .AND. STMAX-STMIN .LE. XTOL*STMAX)) STP = STX
729 C
730 C EVALUATE THE FUNCTION AND GRADIENT AT STP
731 C AND COMPUTE THE DIRECTIONAL DERIVATIVE.
732 C We return to main program to obtain F and G.
733 C
734 DO 40 J = 1, N
735 X(J) = WA(J) + STP*S(J)
736 40 CONTINUE
737 INFO=-1
738 RETURN
739 C
740 45 INFO=0
741 NFEV = NFEV + 1
742 DG = ZERO
743 DO 50 J = 1, N
744 DG = DG + G(J)*S(J)
745 50 CONTINUE
746 FTEST1 = FINIT + STP*DGTEST
747 C
748 C TEST FOR CONVERGENCE.
749 C
750 IF ((BRACKT .AND. (STP .LE. STMIN .OR. STP .GE. STMAX))
751 * .OR. INFOC .EQ. 0) INFO = 6
752 IF (STP .EQ. STPMAX .AND.
753 * F .LE. FTEST1 .AND. DG .LE. DGTEST) INFO = 5
754 IF (STP .EQ. STPMIN .AND.
755 * (F .GT. FTEST1 .OR. DG .GE. DGTEST)) INFO = 4
756 IF (NFEV .GE. MAXFEV) INFO = 3
757 IF (BRACKT .AND. STMAX-STMIN .LE. XTOL*STMAX) INFO = 2
758 IF (F .LE. FTEST1 .AND. ABS(DG) .LE. GTOL*(-DGINIT)) INFO = 1
759 C
760 C CHECK FOR TERMINATION.
761 C
762 IF (INFO .NE. 0) RETURN
763 C
764 C IN THE FIRST STAGE WE SEEK A STEP FOR WHICH THE MODIFIED
765 C FUNCTION HAS A NONPOSITIVE VALUE AND NONNEGATIVE DERIVATIVE.
766 C
767 IF (STAGE1 .AND. F .LE. FTEST1 .AND.
768 * DG .GE. MIN(FTOL,GTOL)*DGINIT) STAGE1 = .FALSE.
769 C
770 C A MODIFIED FUNCTION IS USED TO PREDICT THE STEP ONLY IF
771 C WE HAVE NOT OBTAINED A STEP FOR WHICH THE MODIFIED
772 C FUNCTION HAS A NONPOSITIVE FUNCTION VALUE AND NONNEGATIVE
773 C DERIVATIVE, AND IF A LOWER FUNCTION VALUE HAS BEEN
774 C OBTAINED BUT THE DECREASE IS NOT SUFFICIENT.
775 C
776 IF (STAGE1 .AND. F .LE. FX .AND. F .GT. FTEST1) THEN
777 C
778 C DEFINE THE MODIFIED FUNCTION AND DERIVATIVE VALUES.
779 C
780 FM = F - STP*DGTEST
781 FXM = FX - STX*DGTEST
782 FYM = FY - STY*DGTEST
783 DGM = DG - DGTEST
784 DGXM = DGX - DGTEST
785 DGYM = DGY - DGTEST
786 C
787 C CALL CSTEP TO UPDATE THE INTERVAL OF UNCERTAINTY
788 C AND TO COMPUTE THE NEW STEP.
789 C
790 CALL MCSTEP(STX,FXM,DGXM,STY,FYM,DGYM,STP,FM,DGM,
791 * BRACKT,STMIN,STMAX,INFOC)
792 C
793 C RESET THE FUNCTION AND GRADIENT VALUES FOR F.
794 C
795 FX = FXM + STX*DGTEST
796 FY = FYM + STY*DGTEST
797 DGX = DGXM + DGTEST
798 DGY = DGYM + DGTEST
799 ELSE
800 C
801 C CALL MCSTEP TO UPDATE THE INTERVAL OF UNCERTAINTY
802 C AND TO COMPUTE THE NEW STEP.
803 C
804 CALL MCSTEP(STX,FX,DGX,STY,FY,DGY,STP,F,DG,
805 * BRACKT,STMIN,STMAX,INFOC)
806 END IF
807 C
808 C FORCE A SUFFICIENT DECREASE IN THE SIZE OF THE
809 C INTERVAL OF UNCERTAINTY.
810 C
811 IF (BRACKT) THEN
812 IF (ABS(STY-STX) .GE. P66*WIDTH1)
813 * STP = STX + P5*(STY - STX)
814 WIDTH1 = WIDTH
815 WIDTH = ABS(STY-STX)
816 END IF
817 C
818 C END OF ITERATION.
819 C
820 GO TO 30
821 C
822 C LAST LINE OF SUBROUTINE MCSRCH.
823 C
824 END
825 SUBROUTINE MCSTEP(STX,FX,DX,STY,FY,DY,STP,FP,DP,BRACKT,
826 * STPMIN,STPMAX,INFO)
827 INTEGER INFO
828 DOUBLE PRECISION STX,FX,DX,STY,FY,DY,STP,FP,DP,STPMIN,STPMAX
829 LOGICAL BRACKT,BOUND
830 C
831 C SUBROUTINE MCSTEP
832 C
833 C THE PURPOSE OF MCSTEP IS TO COMPUTE A SAFEGUARDED STEP FOR
834 C A LINESEARCH AND TO UPDATE AN INTERVAL OF UNCERTAINTY FOR
835 C A MINIMIZER OF THE FUNCTION.
836 C
837 C THE PARAMETER STX CONTAINS THE STEP WITH THE LEAST FUNCTION
838 C VALUE. THE PARAMETER STP CONTAINS THE CURRENT STEP. IT IS
839 C ASSUMED THAT THE DERIVATIVE AT STX IS NEGATIVE IN THE
840 C DIRECTION OF THE STEP. IF BRACKT IS SET TRUE THEN A
841 C MINIMIZER HAS BEEN BRACKETED IN AN INTERVAL OF UNCERTAINTY
842 C WITH ENDPOINTS STX AND STY.
843 C
844 C THE SUBROUTINE STATEMENT IS
845 C
846 C SUBROUTINE MCSTEP(STX,FX,DX,STY,FY,DY,STP,FP,DP,BRACKT,
847 C STPMIN,STPMAX,INFO)
848 C
849 C WHERE
850 C
851 C STX, FX, AND DX ARE VARIABLES WHICH SPECIFY THE STEP,
852 C THE FUNCTION, AND THE DERIVATIVE AT THE BEST STEP OBTAINED
853 C SO FAR. THE DERIVATIVE MUST BE NEGATIVE IN THE DIRECTION
854 C OF THE STEP, THAT IS, DX AND STP-STX MUST HAVE OPPOSITE
855 C SIGNS. ON OUTPUT THESE PARAMETERS ARE UPDATED APPROPRIATELY.
856 C
857 C STY, FY, AND DY ARE VARIABLES WHICH SPECIFY THE STEP,
858 C THE FUNCTION, AND THE DERIVATIVE AT THE OTHER ENDPOINT OF
859 C THE INTERVAL OF UNCERTAINTY. ON OUTPUT THESE PARAMETERS ARE
860 C UPDATED APPROPRIATELY.
861 C
862 C STP, FP, AND DP ARE VARIABLES WHICH SPECIFY THE STEP,
863 C THE FUNCTION, AND THE DERIVATIVE AT THE CURRENT STEP.
864 C IF BRACKT IS SET TRUE THEN ON INPUT STP MUST BE
865 C BETWEEN STX AND STY. ON OUTPUT STP IS SET TO THE NEW STEP.
866 C
867 C BRACKT IS A LOGICAL VARIABLE WHICH SPECIFIES IF A MINIMIZER
868 C HAS BEEN BRACKETED. IF THE MINIMIZER HAS NOT BEEN BRACKETED
869 C THEN ON INPUT BRACKT MUST BE SET FALSE. IF THE MINIMIZER
870 C IS BRACKETED THEN ON OUTPUT BRACKT IS SET TRUE.
871 C
872 C STPMIN AND STPMAX ARE INPUT VARIABLES WHICH SPECIFY LOWER
873 C AND UPPER BOUNDS FOR THE STEP.
874 C
875 C INFO IS AN INTEGER OUTPUT VARIABLE SET AS FOLLOWS:
876 C IF INFO = 1,2,3,4,5, THEN THE STEP HAS BEEN COMPUTED
877 C ACCORDING TO ONE OF THE FIVE CASES BELOW. OTHERWISE
878 C INFO = 0, AND THIS INDICATES IMPROPER INPUT PARAMETERS.
879 C
880 C SUBPROGRAMS CALLED
881 C
882 C FORTRAN-SUPPLIED ... ABS,MAX,MIN,SQRT
883 C
884 C ARGONNE NATIONAL LABORATORY. MINPACK PROJECT. JUNE 1983
885 C JORGE J. MORE', DAVID J. THUENTE
886 C
887 DOUBLE PRECISION GAMMA,P,Q,R,S,SGND,STPC,STPF,STPQ,THETA
888 INFO = 0
889 C
890 C CHECK THE INPUT PARAMETERS FOR ERRORS.
891 C
892 IF ((BRACKT .AND. (STP .LE. MIN(STX,STY) .OR.
893 * STP .GE. MAX(STX,STY))) .OR.
894 * DX*(STP-STX) .GE. 0.0 .OR. STPMAX .LT. STPMIN) RETURN
895 C
896 C DETERMINE IF THE DERIVATIVES HAVE OPPOSITE SIGN.
897 C
898 SGND = DP*(DX/ABS(DX))
899 C
900 C FIRST CASE. A HIGHER FUNCTION VALUE.
901 C THE MINIMUM IS BRACKETED. IF THE CUBIC STEP IS CLOSER
902 C TO STX THAN THE QUADRATIC STEP, THE CUBIC STEP IS TAKEN,
903 C ELSE THE AVERAGE OF THE CUBIC AND QUADRATIC STEPS IS TAKEN.
904 C
905 IF (FP .GT. FX) THEN
906 INFO = 1
907 BOUND = .TRUE.
908 THETA = 3*(FX - FP)/(STP - STX) + DX + DP
909 S = MAX(ABS(THETA),ABS(DX),ABS(DP))
910 GAMMA = S*SQRT((THETA/S)**2 - (DX/S)*(DP/S))
911 IF (STP .LT. STX) GAMMA = -GAMMA
912 P = (GAMMA - DX) + THETA
913 Q = ((GAMMA - DX) + GAMMA) + DP
914 R = P/Q
915 STPC = STX + R*(STP - STX)
916 STPQ = STX + ((DX/((FX-FP)/(STP-STX)+DX))/2)*(STP - STX)
917 IF (ABS(STPC-STX) .LT. ABS(STPQ-STX)) THEN
918 STPF = STPC
919 ELSE
920 STPF = STPC + (STPQ - STPC)/2
921 END IF
922 BRACKT = .TRUE.
923 C
924 C SECOND CASE. A LOWER FUNCTION VALUE AND DERIVATIVES OF
925 C OPPOSITE SIGN. THE MINIMUM IS BRACKETED. IF THE CUBIC
926 C STEP IS CLOSER TO STX THAN THE QUADRATIC (SECANT) STEP,
927 C THE CUBIC STEP IS TAKEN, ELSE THE QUADRATIC STEP IS TAKEN.
928 C
929 ELSE IF (SGND .LT. 0.0) THEN
930 INFO = 2
931 BOUND = .FALSE.
932 THETA = 3*(FX - FP)/(STP - STX) + DX + DP
933 S = MAX(ABS(THETA),ABS(DX),ABS(DP))
934 GAMMA = S*SQRT((THETA/S)**2 - (DX/S)*(DP/S))
935 IF (STP .GT. STX) GAMMA = -GAMMA
936 P = (GAMMA - DP) + THETA
937 Q = ((GAMMA - DP) + GAMMA) + DX
938 R = P/Q
939 STPC = STP + R*(STX - STP)
940 STPQ = STP + (DP/(DP-DX))*(STX - STP)
941 IF (ABS(STPC-STP) .GT. ABS(STPQ-STP)) THEN
942 STPF = STPC
943 ELSE
944 STPF = STPQ
945 END IF
946 BRACKT = .TRUE.
947 C
948 C THIRD CASE. A LOWER FUNCTION VALUE, DERIVATIVES OF THE
949 C SAME SIGN, AND THE MAGNITUDE OF THE DERIVATIVE DECREASES.
950 C THE CUBIC STEP IS ONLY USED IF THE CUBIC TENDS TO INFINITY
951 C IN THE DIRECTION OF THE STEP OR IF THE MINIMUM OF THE CUBIC
952 C IS BEYOND STP. OTHERWISE THE CUBIC STEP IS DEFINED TO BE
953 C EITHER STPMIN OR STPMAX. THE QUADRATIC (SECANT) STEP IS ALSO
954 C COMPUTED AND IF THE MINIMUM IS BRACKETED THEN THE THE STEP
955 C CLOSEST TO STX IS TAKEN, ELSE THE STEP FARTHEST AWAY IS TAKEN.
956 C
957 ELSE IF (ABS(DP) .LT. ABS(DX)) THEN
958 INFO = 3
959 BOUND = .TRUE.
960 THETA = 3*(FX - FP)/(STP - STX) + DX + DP
961 S = MAX(ABS(THETA),ABS(DX),ABS(DP))
962 C
963 C THE CASE GAMMA = 0 ONLY ARISES IF THE CUBIC DOES NOT TEND
964 C TO INFINITY IN THE DIRECTION OF THE STEP.
965 C
966 GAMMA = S*SQRT(MAX(0.0D0,(THETA/S)**2 - (DX/S)*(DP/S)))
967 IF (STP .GT. STX) GAMMA = -GAMMA
968 P = (GAMMA - DP) + THETA
969 Q = (GAMMA + (DX - DP)) + GAMMA
970 R = P/Q
971 IF (R .LT. 0.0 .AND. GAMMA .NE. 0.0) THEN
972 STPC = STP + R*(STX - STP)
973 ELSE IF (STP .GT. STX) THEN
974 STPC = STPMAX
975 ELSE
976 STPC = STPMIN
977 END IF
978 STPQ = STP + (DP/(DP-DX))*(STX - STP)
979 IF (BRACKT) THEN
980 IF (ABS(STP-STPC) .LT. ABS(STP-STPQ)) THEN
981 STPF = STPC
982 ELSE
983 STPF = STPQ
984 END IF
985 ELSE
986 IF (ABS(STP-STPC) .GT. ABS(STP-STPQ)) THEN
987 STPF = STPC
988 ELSE
989 STPF = STPQ
990 END IF
991 END IF
992 C
993 C FOURTH CASE. A LOWER FUNCTION VALUE, DERIVATIVES OF THE
994 C SAME SIGN, AND THE MAGNITUDE OF THE DERIVATIVE DOES
995 C NOT DECREASE. IF THE MINIMUM IS NOT BRACKETED, THE STEP
996 C IS EITHER STPMIN OR STPMAX, ELSE THE CUBIC STEP IS TAKEN.
997 C
998 ELSE
999 INFO = 4
1000 BOUND = .FALSE.
1001 IF (BRACKT) THEN
1002 THETA = 3*(FP - FY)/(STY - STP) + DY + DP
1003 S = MAX(ABS(THETA),ABS(DY),ABS(DP))
1004 GAMMA = S*SQRT((THETA/S)**2 - (DY/S)*(DP/S))
1005 IF (STP .GT. STY) GAMMA = -GAMMA
1006 P = (GAMMA - DP) + THETA
1007 Q = ((GAMMA - DP) + GAMMA) + DY
1008 R = P/Q
1009 STPC = STP + R*(STY - STP)
1010 STPF = STPC
1011 ELSE IF (STP .GT. STX) THEN
1012 STPF = STPMAX
1013 ELSE
1014 STPF = STPMIN
1015 END IF
1016 END IF
1017 C
1018 C UPDATE THE INTERVAL OF UNCERTAINTY. THIS UPDATE DOES NOT
1019 C DEPEND ON THE NEW STEP OR THE CASE ANALYSIS ABOVE.
1020 C
1021 IF (FP .GT. FX) THEN
1022 STY = STP
1023 FY = FP
1024 DY = DP
1025 ELSE
1026 IF (SGND .LT. 0.0) THEN
1027 STY = STX
1028 FY = FX
1029 DY = DX
1030 END IF
1031 STX = STP
1032 FX = FP
1033 DX = DP
1034 END IF
1035 C
1036 C COMPUTE THE NEW STEP AND SAFEGUARD IT.
1037 C
1038 STPF = MIN(STPMAX,STPF)
1039 STPF = MAX(STPMIN,STPF)
1040 STP = STPF
1041 IF (BRACKT .AND. BOUND) THEN
1042 IF (STY .GT. STX) THEN
1043 STP = MIN(STX+0.66*(STY-STX),STP)
1044 ELSE
1045 STP = MAX(STX+0.66*(STY-STX),STP)
1046 END IF
1047 END IF
1048 RETURN
1049 C
1050 C LAST LINE OF SUBROUTINE MCSTEP.
1051 C
1052 END
1053