Debian Codegraph @

definitions/EARTHCARE/types/ISP_BBR_ICU.xml

raw
1 <?xml version="1.0"?>
2 <cd:Record xmlns:cd="http://www.stcorp.nl/coda/definition/2008/07" xmlns:ct="http://www.stcorp.nl/coda/test/2008/10" format="binary" last-modified="2021-11-11" name="ISP_BBR_ICU">
3 <cd:Description>ISP BBR ICU data</cd:Description>
4 <cd:Field name="delimiter_3">
5 <cd:Integer>
6 <cd:Description>Fixed Field Delimiter</cd:Description>
7 <cd:BitSize>16</cd:BitSize>
8 <cd:NativeType>uint16</cd:NativeType>
9 </cd:Integer>
10 <cd:Hidden/>
11 </cd:Field>
12 <cd:Field name="temp_CDM_winding">
13 <cd:Integer>
14 <cd:Description>Temperature of the CDM winding</cd:Description>
15 <cd:BitSize>16</cd:BitSize>
16 <cd:NativeType>uint16</cd:NativeType>
17 </cd:Integer>
18 </cd:Field>
19 <cd:Field name="temp_CTM_winding">
20 <cd:Integer>
21 <cd:Description>Temperature of the CTM winding</cd:Description>
22 <cd:BitSize>16</cd:BitSize>
23 <cd:NativeType>uint16</cd:NativeType>
24 </cd:Integer>
25 </cd:Field>
26 <cd:Field name="temp_CTM_encoder">
27 <cd:Integer>
28 <cd:Description>Temperature of the CTM encoder</cd:Description>
29 <cd:BitSize>16</cd:BitSize>
30 <cd:NativeType>uint16</cd:NativeType>
31 </cd:Integer>
32 </cd:Field>
33 <cd:Field name="temp_MA_radiator">
34 <cd:Integer>
35 <cd:Description>Temperature of the MA radiator</cd:Description>
36 <cd:BitSize>16</cd:BitSize>
37 <cd:NativeType>uint16</cd:NativeType>
38 </cd:Integer>
39 </cd:Field>
40 <cd:Field name="temp_MA_thermostates">
41 <cd:Integer>
42 <cd:Description>Temperature of the MA thermostates</cd:Description>
43 <cd:BitSize>16</cd:BitSize>
44 <cd:NativeType>uint16</cd:NativeType>
45 </cd:Integer>
46 </cd:Field>
47 <cd:Field name="temp_CDM_encoder">
48 <cd:Integer>
49 <cd:Description>Temperature of the CDM encoder</cd:Description>
50 <cd:BitSize>16</cd:BitSize>
51 <cd:NativeType>uint16</cd:NativeType>
52 </cd:Integer>
53 </cd:Field>
54 <cd:Field name="temp_fore_baseplate">
55 <cd:Integer>
56 <cd:Description>Temperature of the Fore telescope baseplate</cd:Description>
57 <cd:BitSize>16</cd:BitSize>
58 <cd:NativeType>uint16</cd:NativeType>
59 </cd:Integer>
60 </cd:Field>
61 <cd:Field name="temp_nadir_baseplate">
62 <cd:Integer>
63 <cd:Description>Temperature of the Nadir telescope baseplate</cd:Description>
64 <cd:BitSize>16</cd:BitSize>
65 <cd:NativeType>uint16</cd:NativeType>
66 </cd:Integer>
67 </cd:Field>
68 <cd:Field name="temp_aft_baseplate">
69 <cd:Integer>
70 <cd:Description>Temperature of the Aft telescope baseplate</cd:Description>
71 <cd:BitSize>16</cd:BitSize>
72 <cd:NativeType>uint16</cd:NativeType>
73 </cd:Integer>
74 </cd:Field>
75 <cd:Field name="temp_FOA_baseplate">
76 <cd:Integer>
77 <cd:Description>Temperature of the Fixed Optics Assembly baseplate</cd:Description>
78 <cd:BitSize>16</cd:BitSize>
79 <cd:NativeType>uint16</cd:NativeType>
80 </cd:Integer>
81 </cd:Field>
82 <cd:Field name="temp_aft_baffle">
83 <cd:Integer>
84 <cd:Description>Temperature of the Aft telescope foreoptics baffle</cd:Description>
85 <cd:BitSize>16</cd:BitSize>
86 <cd:NativeType>uint16</cd:NativeType>
87 </cd:Integer>
88 </cd:Field>
89 <cd:Field name="temp_cal_drum_1">
90 <cd:Integer>
91 <cd:Description>Temperature of the Calibration drum (position 1)</cd:Description>
92 <cd:BitSize>16</cd:BitSize>
93 <cd:NativeType>uint16</cd:NativeType>
94 </cd:Integer>
95 </cd:Field>
96 <cd:Field name="temp_cal_drum_2">
97 <cd:Integer>
98 <cd:Description>Temperature of the Calibration drum (position 2)</cd:Description>
99 <cd:BitSize>16</cd:BitSize>
100 <cd:NativeType>uint16</cd:NativeType>
101 </cd:Integer>
102 </cd:Field>
103 <cd:Field name="temp_viscal_1">
104 <cd:Integer>
105 <cd:Description>Temperature of the VisCal (position 1)</cd:Description>
106 <cd:BitSize>16</cd:BitSize>
107 <cd:NativeType>uint16</cd:NativeType>
108 </cd:Integer>
109 </cd:Field>
110 <cd:Field name="temp_viscal_2">
111 <cd:Integer>
112 <cd:Description>Temperature of the VisCal (position 2)</cd:Description>
113 <cd:BitSize>16</cd:BitSize>
114 <cd:NativeType>uint16</cd:NativeType>
115 </cd:Integer>
116 </cd:Field>
117 <cd:Field name="temp_main_radiator_1">
118 <cd:Integer>
119 <cd:Description>Temperature of the main radiator (position 1)</cd:Description>
120 <cd:BitSize>16</cd:BitSize>
121 <cd:NativeType>uint16</cd:NativeType>
122 </cd:Integer>
123 </cd:Field>
124 <cd:Field name="temp_main_radiator_2">
125 <cd:Integer>
126 <cd:Description>Temperature of the main radiator (position 2)</cd:Description>
127 <cd:BitSize>16</cd:BitSize>
128 <cd:NativeType>uint16</cd:NativeType>
129 </cd:Integer>
130 </cd:Field>
131 <cd:Field name="temp_MX_panel">
132 <cd:Integer>
133 <cd:Description>Temperature of the -X panel internal</cd:Description>
134 <cd:BitSize>16</cd:BitSize>
135 <cd:NativeType>uint16</cd:NativeType>
136 </cd:Integer>
137 </cd:Field>
138 <cd:Field name="temp_PY_panel">
139 <cd:Integer>
140 <cd:Description>Temperature of the +Y panel internal</cd:Description>
141 <cd:BitSize>16</cd:BitSize>
142 <cd:NativeType>uint16</cd:NativeType>
143 </cd:Integer>
144 </cd:Field>
145 <cd:Field name="temp_MY_panel">
146 <cd:Integer>
147 <cd:Description>Temperature of the -Y panel internal</cd:Description>
148 <cd:BitSize>16</cd:BitSize>
149 <cd:NativeType>uint16</cd:NativeType>
150 </cd:Integer>
151 </cd:Field>
152 <cd:Field name="temp_PZ_panel">
153 <cd:Integer>
154 <cd:Description>Temperature of the +Z panel internal</cd:Description>
155 <cd:BitSize>16</cd:BitSize>
156 <cd:NativeType>uint16</cd:NativeType>
157 </cd:Integer>
158 </cd:Field>
159 <cd:Field name="temp_decontamination_plate">
160 <cd:Integer>
161 <cd:Description>Temperature of the chopper decontamination plate</cd:Description>
162 <cd:BitSize>16</cd:BitSize>
163 <cd:NativeType>uint16</cd:NativeType>
164 </cd:Integer>
165 </cd:Field>
166 <cd:Field name="temp_ICU_AAM">
167 <cd:Integer>
168 <cd:Description>Temperature of the ICU analog acquisitions module</cd:Description>
169 <cd:BitSize>16</cd:BitSize>
170 <cd:NativeType>uint16</cd:NativeType>
171 </cd:Integer>
172 </cd:Field>
173 <cd:Field name="temp_ICU_processor">
174 <cd:Integer>
175 <cd:Description>Temperature of the ICU processor module</cd:Description>
176 <cd:BitSize>16</cd:BitSize>
177 <cd:NativeType>uint16</cd:NativeType>
178 </cd:Integer>
179 </cd:Field>
180 <cd:Field name="temp_ICU_chassis">
181 <cd:Integer>
182 <cd:Description>Temperature of the ICU chassis</cd:Description>
183 <cd:BitSize>16</cd:BitSize>
184 <cd:NativeType>uint16</cd:NativeType>
185 </cd:Integer>
186 </cd:Field>
187 <cd:Field name="temp_ICU_PDM_1">
188 <cd:Integer>
189 <cd:Description>Temperature of the ICU power and drive module (position 1)</cd:Description>
190 <cd:BitSize>16</cd:BitSize>
191 <cd:NativeType>uint16</cd:NativeType>
192 </cd:Integer>
193 </cd:Field>
194 <cd:Field name="temp_ICU_PDM_2">
195 <cd:Integer>
196 <cd:Description>Temperature of the ICU power and drive module (position 2)</cd:Description>
197 <cd:BitSize>16</cd:BitSize>
198 <cd:NativeType>uint16</cd:NativeType>
199 </cd:Integer>
200 </cd:Field>
201 <cd:Field name="temp_ICU_PDM_3">
202 <cd:Integer>
203 <cd:Description>Temperature of the ICU power and drive module (position 3)</cd:Description>
204 <cd:BitSize>16</cd:BitSize>
205 <cd:NativeType>uint16</cd:NativeType>
206 </cd:Integer>
207 </cd:Field>
208 <cd:Field name="spare3">
209 <cd:Raw>
210 <cd:BitSize>64</cd:BitSize>
211 </cd:Raw>
212 <cd:Hidden/>
213 </cd:Field>
214 <cd:Field name="voltage_monitor_P12">
215 <cd:Integer>
216 <cd:Description>Voltage monitor for the +12V supply</cd:Description>
217 <cd:BitSize>16</cd:BitSize>
218 <cd:NativeType>uint16</cd:NativeType>
219 </cd:Integer>
220 </cd:Field>
221 <cd:Field name="voltage_monitor_M5">
222 <cd:Integer>
223 <cd:Description>Voltage monitor for the -5V supply</cd:Description>
224 <cd:BitSize>16</cd:BitSize>
225 <cd:NativeType>uint16</cd:NativeType>
226 </cd:Integer>
227 </cd:Field>
228 <cd:Field name="voltage_monitor_M12">
229 <cd:Integer>
230 <cd:Description>Voltage monitor for the -12V supply</cd:Description>
231 <cd:BitSize>16</cd:BitSize>
232 <cd:NativeType>uint16</cd:NativeType>
233 </cd:Integer>
234 </cd:Field>
235 <cd:Field name="voltage_monitor_P3_3">
236 <cd:Integer>
237 <cd:Description>Voltage monitor for the +3.3V supply</cd:Description>
238 <cd:BitSize>16</cd:BitSize>
239 <cd:NativeType>uint16</cd:NativeType>
240 </cd:Integer>
241 </cd:Field>
242 <cd:Field name="spare4">
243 <cd:Integer>
244 <cd:Description>Spare voltage monitor</cd:Description>
245 <cd:BitSize>16</cd:BitSize>
246 <cd:NativeType>uint16</cd:NativeType>
247 </cd:Integer>
248 <cd:Hidden/>
249 </cd:Field>
250 <cd:Field name="voltage_monitor_ADC_1">
251 <cd:Integer>
252 <cd:Description>Voltage monitor for the ADC reference 1</cd:Description>
253 <cd:BitSize>16</cd:BitSize>
254 <cd:NativeType>uint16</cd:NativeType>
255 </cd:Integer>
256 </cd:Field>
257 <cd:Field name="voltage_monitor_ADC_2">
258 <cd:Integer>
259 <cd:Description>Voltage monitor for the ADC reference 2</cd:Description>
260 <cd:BitSize>16</cd:BitSize>
261 <cd:NativeType>uint16</cd:NativeType>
262 </cd:Integer>
263 </cd:Field>
264 <cd:Field name="current_monitor_CTM_motor">
265 <cd:Integer>
266 <cd:Description>Current monitor for the CTM motor</cd:Description>
267 <cd:BitSize>16</cd:BitSize>
268 <cd:NativeType>uint16</cd:NativeType>
269 </cd:Integer>
270 </cd:Field>
271 <cd:Field name="current_monitor_CDM_motor">
272 <cd:Integer>
273 <cd:Description>Current monitor for the CDM motor</cd:Description>
274 <cd:BitSize>16</cd:BitSize>
275 <cd:NativeType>uint16</cd:NativeType>
276 </cd:Integer>
277 </cd:Field>
278 <cd:Field name="current_monitor_heaters">
279 <cd:Integer>
280 <cd:Description>Current monitor for the heaters</cd:Description>
281 <cd:BitSize>16</cd:BitSize>
282 <cd:NativeType>uint16</cd:NativeType>
283 </cd:Integer>
284 </cd:Field>
285 <cd:Field name="voltage_monitor_CDM_encoder">
286 <cd:Integer>
287 <cd:Description>Voltage monitor for the CDM encoder</cd:Description>
288 <cd:BitSize>16</cd:BitSize>
289 <cd:NativeType>uint16</cd:NativeType>
290 </cd:Integer>
291 </cd:Field>
292 <cd:Field name="voltage_monitor_CTM_encoder">
293 <cd:Integer>
294 <cd:Description>Voltage monitor for the CTM encoder</cd:Description>
295 <cd:BitSize>16</cd:BitSize>
296 <cd:NativeType>uint16</cd:NativeType>
297 </cd:Integer>
298 </cd:Field>
299 <cd:Field name="voltage_monitor_motor_supply">
300 <cd:Integer>
301 <cd:Description>Voltage monitor for the 24V motor supply rail</cd:Description>
302 <cd:BitSize>16</cd:BitSize>
303 <cd:NativeType>uint16</cd:NativeType>
304 </cd:Integer>
305 </cd:Field>
306 <cd:Field name="voltage_monitor_heater_supply">
307 <cd:Integer>
308 <cd:Description>Voltage monitor for the 20V heater supply rail</cd:Description>
309 <cd:BitSize>16</cd:BitSize>
310 <cd:NativeType>uint16</cd:NativeType>
311 </cd:Integer>
312 </cd:Field>
313 <cd:Field name="spare5">
314 <cd:Raw>
315 <cd:BitSize>288</cd:BitSize>
316 </cd:Raw>