| 1 |
// Copyright The OpenTelemetry Authors |
| 2 |
// SPDX-License-Identifier: Apache-2.0 |
| 3 |
|
| 4 |
package host // import "go.opentelemetry.io/contrib/instrumentation/host" |
| 5 |
|
| 6 |
import ( |
| 7 |
"context" |
| 8 |
"errors" |
| 9 |
"fmt" |
| 10 |
"math" |
| 11 |
"os" |
| 12 |
"sync" |
| 13 |
|
| 14 |
"github.com/shirou/gopsutil/v4/cpu" |
| 15 |
"github.com/shirou/gopsutil/v4/mem" |
| 16 |
"github.com/shirou/gopsutil/v4/net" |
| 17 |
"github.com/shirou/gopsutil/v4/process" |
| 18 |
"go.opentelemetry.io/otel" |
| 19 |
"go.opentelemetry.io/otel/attribute" |
| 20 |
"go.opentelemetry.io/otel/metric" |
| 21 |
"go.opentelemetry.io/otel/semconv/v1.40.0/processconv" |
| 22 |
"go.opentelemetry.io/otel/semconv/v1.40.0/systemconv" |
| 23 |
) |
| 24 |
|
| 25 |
// ScopeName is the instrumentation scope name. |
| 26 |
const ScopeName = "go.opentelemetry.io/contrib/instrumentation/host" |
| 27 |
|
| 28 |
// Host reports the work-in-progress conventional host metrics specified by OpenTelemetry. |
| 29 |
type host struct { |
| 30 |
config config |
| 31 |
meter metric.Meter |
| 32 |
} |
| 33 |
|
| 34 |
// config contains optional settings for reporting host metrics. |
| 35 |
type config struct { |
| 36 |
// MeterProvider sets the metric.MeterProvider. If nil, the global |
| 37 |
// Provider will be used. |
| 38 |
MeterProvider metric.MeterProvider |
| 39 |
} |
| 40 |
|
| 41 |
// Option supports configuring optional settings for host metrics. |
| 42 |
type Option interface { |
| 43 |
apply(*config) |
| 44 |
} |
| 45 |
|
| 46 |
// WithMeterProvider sets the Metric implementation to use for |
| 47 |
// reporting. If this option is not used, the global metric.MeterProvider |
| 48 |
// will be used. `provider` must be non-nil. |
| 49 |
func WithMeterProvider(provider metric.MeterProvider) Option { |
| 50 |
return metricProviderOption{provider} |
| 51 |
} |
| 52 |
|
| 53 |
type metricProviderOption struct{ metric.MeterProvider } |
| 54 |
|
| 55 |
func (o metricProviderOption) apply(c *config) { |
| 56 |
if o.MeterProvider != nil { |
| 57 |
c.MeterProvider = o.MeterProvider |
| 58 |
} |
| 59 |
} |
| 60 |
|
| 61 |
// Attribute sets. |
| 62 |
var ( |
| 63 |
// Attribute sets for CPU time measurements. |
| 64 |
|
| 65 |
// Deprecated: Use go.opentelemetry.io/otel/semconv instead. |
| 66 |
AttributeCPUTimeUser = attribute.NewSet(attribute.String("state", "user")) |
| 67 |
// Deprecated: Use go.opentelemetry.io/otel/semconv instead. |
| 68 |
AttributeCPUTimeSystem = attribute.NewSet(attribute.String("state", "system")) |
| 69 |
// Deprecated: Use go.opentelemetry.io/otel/semconv instead. |
| 70 |
AttributeCPUTimeOther = attribute.NewSet(attribute.String("state", "other")) |
| 71 |
// Deprecated: Use go.opentelemetry.io/otel/semconv instead. |
| 72 |
AttributeCPUTimeIdle = attribute.NewSet(attribute.String("state", "idle")) |
| 73 |
|
| 74 |
// Attribute sets used for Memory measurements. |
| 75 |
|
| 76 |
// Deprecated: Use go.opentelemetry.io/otel/semconv instead. |
| 77 |
AttributeMemoryAvailable = attribute.NewSet(attribute.String("state", "available")) |
| 78 |
// Deprecated: Use go.opentelemetry.io/otel/semconv instead. |
| 79 |
AttributeMemoryUsed = attribute.NewSet(attribute.String("state", "used")) |
| 80 |
|
| 81 |
// Attribute sets used for Network measurements. |
| 82 |
|
| 83 |
// Deprecated: Use go.opentelemetry.io/otel/semconv instead. |
| 84 |
AttributeNetworkTransmit = attribute.NewSet(attribute.String("direction", "transmit")) |
| 85 |
// Deprecated: Use go.opentelemetry.io/otel/semconv instead. |
| 86 |
AttributeNetworkReceive = attribute.NewSet(attribute.String("direction", "receive")) |
| 87 |
) |
| 88 |
|
| 89 |
// newConfig computes a config from a list of Options. |
| 90 |
func newConfig(opts ...Option) config { |
| 91 |
c := config{ |
| 92 |
MeterProvider: otel.GetMeterProvider(), |
| 93 |
} |
| 94 |
for _, opt := range opts { |
| 95 |
opt.apply(&c) |
| 96 |
} |
| 97 |
return c |
| 98 |
} |
| 99 |
|
| 100 |
// Start initializes reporting of host metrics using the supplied config. |
| 101 |
func Start(opts ...Option) error { |
| 102 |
c := newConfig(opts...) |
| 103 |
if c.MeterProvider == nil { |
| 104 |
c.MeterProvider = otel.GetMeterProvider() |
| 105 |
} |
| 106 |
h := &host{ |
| 107 |
meter: c.MeterProvider.Meter( |
| 108 |
ScopeName, |
| 109 |
metric.WithInstrumentationVersion(Version), |
| 110 |
), |
| 111 |
config: c, |
| 112 |
} |
| 113 |
return h.register() |
| 114 |
} |
| 115 |
|
| 116 |
func (h *host) register() error { |
| 117 |
var ( |
| 118 |
err error |
| 119 |
|
| 120 |
procCPUTime processconv.CPUTime |
| 121 |
procCPUTimeModeUser = metric.WithAttributes( |
| 122 |
procCPUTime.AttrCPUMode(processconv.CPUModeUser), |
| 123 |
) |
| 124 |
procCPUTimeModeSystem = metric.WithAttributes( |
| 125 |
procCPUTime.AttrCPUMode(processconv.CPUModeSystem), |
| 126 |
) |
| 127 |
|
| 128 |
cpuTime systemconv.CPUTime |
| 129 |
cpuTimeModeUser = metric.WithAttributes( |
| 130 |
cpuTime.AttrCPUMode(systemconv.CPUModeUser), |
| 131 |
) |
| 132 |
cpuTimeModeSystem = metric.WithAttributes( |
| 133 |
cpuTime.AttrCPUMode(systemconv.CPUModeSystem), |
| 134 |
) |
| 135 |
cpuTimeModeIdle = metric.WithAttributes( |
| 136 |
cpuTime.AttrCPUMode(systemconv.CPUModeIdle), |
| 137 |
) |
| 138 |
cpuTimeModeOther = metric.WithAttributes( |
| 139 |
cpuTime.AttrCPUMode(systemconv.CPUModeAttr("other")), |
| 140 |
) |
| 141 |
|
| 142 |
memUse systemconv.MemoryUsage |
| 143 |
memUseStateFree = metric.WithAttributes( |
| 144 |
memUse.AttrMemoryState(systemconv.MemoryStateFree), |
| 145 |
) |
| 146 |
memUseStateUsed = metric.WithAttributes( |
| 147 |
memUse.AttrMemoryState(systemconv.MemoryStateUsed), |
| 148 |
) |
| 149 |
|
| 150 |
memUtil systemconv.MemoryUtilization |
| 151 |
memUtilStateFree = metric.WithAttributes( |
| 152 |
memUtil.AttrMemoryState(systemconv.MemoryStateFree), |
| 153 |
) |
| 154 |
memUtilStateUsed = metric.WithAttributes( |
| 155 |
memUtil.AttrMemoryState(systemconv.MemoryStateUsed), |
| 156 |
) |
| 157 |
|
| 158 |
netIO systemconv.NetworkIO |
| 159 |
netIOStateTransmit = metric.WithAttributes( |
| 160 |
netIO.AttrNetworkIODirection(systemconv.NetworkIODirectionTransmit), |
| 161 |
) |
| 162 |
netIOStateReceive = metric.WithAttributes( |
| 163 |
netIO.AttrNetworkIODirection(systemconv.NetworkIODirectionReceive), |
| 164 |
) |
| 165 |
|
| 166 |
// lock prevents a race between batch observer and instrument registration. |
| 167 |
lock sync.Mutex |
| 168 |
) |
| 169 |
|
| 170 |
pid := os.Getpid() |
| 171 |
if pid > math.MaxInt32 || pid < math.MinInt32 { |
| 172 |
return fmt.Errorf("invalid process ID: %d", pid) |
| 173 |
} |
| 174 |
proc, err := process.NewProcess(int32(pid)) |
| 175 |
if err != nil { |
| 176 |
return fmt.Errorf("could not find this process: %w", err) |
| 177 |
} |
| 178 |
|
| 179 |
lock.Lock() |
| 180 |
defer lock.Unlock() |
| 181 |
|
| 182 |
if procCPUTime, err = processconv.NewCPUTime(h.meter); err != nil { |
| 183 |
return err |
| 184 |
} |
| 185 |
if cpuTime, err = systemconv.NewCPUTime(h.meter); err != nil { |
| 186 |
return err |
| 187 |
} |
| 188 |
if memUse, err = systemconv.NewMemoryUsage(h.meter); err != nil { |
| 189 |
return err |
| 190 |
} |
| 191 |
if memUtil, err = systemconv.NewMemoryUtilization(h.meter); err != nil { |
| 192 |
return err |
| 193 |
} |
| 194 |
if netIO, err = systemconv.NewNetworkIO(h.meter); err != nil { |
| 195 |
return err |
| 196 |
} |
| 197 |
|
| 198 |
_, err = h.meter.RegisterCallback( |
| 199 |
func(ctx context.Context, o metric.Observer) error { |
| 200 |
lock.Lock() |
| 201 |
defer lock.Unlock() |
| 202 |
|
| 203 |
// This follows the OpenTelemetry Collector's "hostmetrics" |
| 204 |
// receiver/hostmetricsreceiver/internal/scraper/processscraper |
| 205 |
// measures User and System IOwait time. |
| 206 |
// TODO: the Collector has per-OS compilation modules to support |
| 207 |
// specific metrics that are not universal. |
| 208 |
processTimes, err := proc.TimesWithContext(ctx) |
| 209 |
if err != nil { |
| 210 |
return err |
| 211 |
} |
| 212 |
|
| 213 |
hostTimeSlice, err := cpu.TimesWithContext(ctx, false) |
| 214 |
if err != nil { |
| 215 |
return err |
| 216 |
} |
| 217 |
if len(hostTimeSlice) != 1 { |
| 218 |
return errors.New("host CPU usage: incorrect summary count") |
| 219 |
} |
| 220 |
|
| 221 |
vmStats, err := mem.VirtualMemoryWithContext(ctx) |
| 222 |
if err != nil { |
| 223 |
return err |
| 224 |
} |
| 225 |
|
| 226 |
ioStats, err := net.IOCountersWithContext(ctx, false) |
| 227 |
if err != nil { |
| 228 |
return err |
| 229 |
} |
| 230 |
if len(ioStats) != 1 { |
| 231 |
return errors.New("host network usage: incorrect summary count") |
| 232 |
} |
| 233 |
|
| 234 |
hostTime := hostTimeSlice[0] |
| 235 |
o.ObserveFloat64(procCPUTime.Inst(), processTimes.User, procCPUTimeModeUser) |
| 236 |
o.ObserveFloat64(procCPUTime.Inst(), processTimes.System, procCPUTimeModeSystem) |
| 237 |
|
| 238 |
o.ObserveFloat64(cpuTime.Inst(), hostTime.User, cpuTimeModeUser) |
| 239 |
o.ObserveFloat64(cpuTime.Inst(), hostTime.System, cpuTimeModeSystem) |
| 240 |
|
| 241 |
// TODO(#244): "other" is a placeholder for actually dealing |
| 242 |
// with these states. Do users actually want this |
| 243 |
// (unconditionally)? How should we handle "iowait" |
| 244 |
// if not all systems expose it? Should we break |
| 245 |
// these down by CPU? If so, are users going to want |
| 246 |
// to aggregate in-process? See: |
| 247 |
// https://github.com/open-telemetry/opentelemetry-go-contrib/issues/244 |
| 248 |
other := hostTime.Nice + |
| 249 |
hostTime.Iowait + |
| 250 |
hostTime.Irq + |
| 251 |
hostTime.Softirq + |
| 252 |
hostTime.Steal + |
| 253 |
hostTime.Guest + |
| 254 |
hostTime.GuestNice |
| 255 |
|
| 256 |
o.ObserveFloat64(cpuTime.Inst(), other, cpuTimeModeOther) |
| 257 |
o.ObserveFloat64(cpuTime.Inst(), hostTime.Idle, cpuTimeModeIdle) |
| 258 |
|
| 259 |
// Host memory usage |
| 260 |
o.ObserveInt64(memUse.Inst(), clampInt64(vmStats.Used), memUseStateUsed) |
| 261 |
o.ObserveInt64(memUse.Inst(), clampInt64(vmStats.Available), memUseStateFree) |
| 262 |
|
| 263 |
// Host memory utilization |
| 264 |
o.ObserveFloat64( |
| 265 |
memUtil.Inst(), |
| 266 |
float64(vmStats.Used)/float64(vmStats.Total), memUtilStateUsed, |
| 267 |
) |
| 268 |
o.ObserveFloat64( |
| 269 |
memUtil.Inst(), |
| 270 |
float64(vmStats.Available)/float64(vmStats.Total), |
| 271 |
memUtilStateFree, |
| 272 |
) |
| 273 |
|
| 274 |
// Host network usage |
| 275 |
// |
| 276 |
// TODO: These can be broken down by network |
| 277 |
// interface, with similar questions to those posed |
| 278 |
// about per-CPU measurements above. |
| 279 |
o.ObserveInt64( |
| 280 |
netIO.Inst(), |
| 281 |
clampInt64(ioStats[0].BytesSent), |
| 282 |
netIOStateTransmit, |
| 283 |
) |
| 284 |
o.ObserveInt64( |
| 285 |
netIO.Inst(), |
| 286 |
clampInt64(ioStats[0].BytesRecv), |
| 287 |
netIOStateReceive, |
| 288 |
) |
| 289 |
|
| 290 |
return nil |
| 291 |
}, |
| 292 |
procCPUTime.Inst(), |
| 293 |
cpuTime.Inst(), |
| 294 |
memUse.Inst(), |
| 295 |
memUtil.Inst(), |
| 296 |
netIO.Inst(), |
| 297 |
) |
| 298 |
if err != nil { |
| 299 |
return err |
| 300 |
} |
| 301 |
|
| 302 |
return nil |
| 303 |
} |
| 304 |
|
| 305 |
func clampInt64(v uint64) int64 { |
| 306 |
if v > math.MaxInt64 { |
| 307 |
return math.MaxInt64 |
| 308 |
} |
| 309 |
return int64(v) |
| 310 |
} |