Debian Codegraph @

src/cmd/compile/abi-internal.md

raw
1 # Go internal ABI specification
2
3 Self-link: [go.dev/s/regabi](https://go.dev/s/regabi)
4
5 This document describes Go’s internal application binary interface
6 (ABI), known as ABIInternal.
7 Go's ABI defines the layout of data in memory and the conventions for
8 calling between Go functions.
9 This ABI is *unstable* and will change between Go versions.
10 If you’re writing assembly code, please instead refer to Go’s
11 [assembly documentation](/doc/asm.html), which describes Go’s stable
12 ABI, known as ABI0.
13
14 All functions defined in Go source follow ABIInternal.
15 However, ABIInternal and ABI0 functions are able to call each other
16 through transparent *ABI wrappers*, described in the [internal calling
17 convention proposal](https://golang.org/design/27539-internal-abi).
18
19 Go uses a common ABI design across all architectures.
20 We first describe the common ABI, and then cover per-architecture
21 specifics.
22
23 *Rationale*: For the reasoning behind using a common ABI across
24 architectures instead of the platform ABI, see the [register-based Go
25 calling convention proposal](https://golang.org/design/40724-register-calling).
26
27 ## Memory layout
28
29 Go's built-in types have the following sizes and alignments.
30 Many, though not all, of these sizes are guaranteed by the [language
31 specification](/doc/go_spec.html#Size_and_alignment_guarantees).
32 Those that aren't guaranteed may change in future versions of Go (for
33 example, we've considered changing the alignment of int64 on 32-bit).
34
35 | Type | 64-bit | | 32-bit | |
36 |-----------------------------|--------|-------|--------|-------|
37 | | Size | Align | Size | Align |
38 | bool, uint8, int8 | 1 | 1 | 1 | 1 |
39 | uint16, int16 | 2 | 2 | 2 | 2 |
40 | uint32, int32 | 4 | 4 | 4 | 4 |
41 | uint64, int64 | 8 | 8 | 8 | 4 |
42 | int, uint | 8 | 8 | 4 | 4 |
43 | float32 | 4 | 4 | 4 | 4 |
44 | float64 | 8 | 8 | 8 | 4 |
45 | complex64 | 8 | 4 | 8 | 4 |
46 | complex128 | 16 | 8 | 16 | 4 |
47 | uintptr, *T, unsafe.Pointer | 8 | 8 | 4 | 4 |
48
49 The types `byte` and `rune` are aliases for `uint8` and `int32`,
50 respectively, and hence have the same size and alignment as these
51 types.
52
53 The layout of `map`, `chan`, and `func` types is equivalent to *T.
54
55 To describe the layout of the remaining composite types, we first
56 define the layout of a *sequence* S of N fields with types
57 t<sub>1</sub>, t<sub>2</sub>, ..., t<sub>N</sub>.
58 We define the byte offset at which each field begins relative to a
59 base address of 0, as well as the size and alignment of the sequence
60 as follows:
61
62 ```
63 offset(S, i) = 0 if i = 1
64 = align(offset(S, i-1) + sizeof(t_(i-1)), alignof(t_i))
65 alignof(S) = 1 if N = 0
66 = max(alignof(t_i) | 1 <= i <= N)
67 sizeof(S) = 0 if N = 0
68 = align(offset(S, N) + sizeof(t_N), alignof(S))
69 ```
70
71 Where sizeof(T) and alignof(T) are the size and alignment of type T,
72 respectively, and align(x, y) rounds x up to a multiple of y.
73
74 The `interface{}` type is a sequence of 1. a pointer to the runtime type
75 description for the interface's dynamic type and 2. an `unsafe.Pointer`
76 data field.
77 Any other interface type (besides the empty interface) is a sequence
78 of 1. a pointer to the runtime "itab" that gives the method pointers and
79 the type of the data field and 2. an `unsafe.Pointer` data field.
80 An interface can be "direct" or "indirect" depending on the dynamic
81 type: a direct interface stores the value directly in the data field,
82 and an indirect interface stores a pointer to the value in the data
83 field.
84 An interface can only be direct if the value consists of a single
85 pointer word.
86
87 An array type `[N]T` is a sequence of N fields of type T.
88
89 The slice type `[]T` is a sequence of a `*[cap]T` pointer to the slice
90 backing store, an `int` giving the `len` of the slice, and an `int`
91 giving the `cap` of the slice.
92
93 The `string` type is a sequence of a `*[len]byte` pointer to the
94 string backing store, and an `int` giving the `len` of the string.
95
96 A struct type `struct { f1 t1; ...; fM tM }` is laid out as the
97 sequence t1, ..., tM, tP, where tP is either:
98
99 - Type `byte` if sizeof(tM) = 0 and any of sizeof(t*i*) ≠ 0.
100 - Empty (size 0 and align 1) otherwise.
101
102 The padding byte prevents creating a past-the-end pointer by taking
103 the address of the final, empty fN field.
104
105 Note that user-written assembly code should generally not depend on Go
106 type layout and should instead use the constants defined in
107 [`go_asm.h`](/doc/asm.html#data-offsets).
108
109 ## Function call argument and result passing
110
111 Function calls pass arguments and results using a combination of the
112 stack and machine registers.
113 Each argument or result is passed either entirely in registers or
114 entirely on the stack.
115 Because access to registers is generally faster than access to the
116 stack, arguments and results are preferentially passed in registers.
117 However, any argument or result that contains a non-trivial array or
118 does not fit entirely in the remaining available registers is passed
119 on the stack.
120
121 Each architecture defines a sequence of integer registers and a
122 sequence of floating-point registers.
123 At a high level, arguments and results are recursively broken down
124 into values of base types and these base values are assigned to
125 registers from these sequences.
126
127 Arguments and results can share the same registers, but do not share
128 the same stack space.
129 Beyond the arguments and results passed on the stack, the caller also
130 reserves spill space on the stack for all register-based arguments
131 (but does not populate this space).
132
133 The receiver, arguments, and results of function or method F are
134 assigned to registers or the stack using the following algorithm:
135
136 1. Let NI and NFP be the length of integer and floating-point register
137 sequences defined by the architecture.
138 Let I and FP be 0; these are the indexes of the next integer and
139 floating-point register.
140 Let S, the type sequence defining the stack frame, be empty.
141 1. If F is a method, assign F’s receiver.
142 1. For each argument A of F, assign A.
143 1. Add a pointer-alignment field to S. This has size 0 and the same
144 alignment as `uintptr`.
145 1. Reset I and FP to 0.
146 1. For each result R of F, assign R.
147 1. Add a pointer-alignment field to S.
148 1. For each register-assigned receiver and argument of F, let T be its
149 type and add T to the stack sequence S.
150 This is the argument's (or receiver's) spill space and will be
151 uninitialized at the call.
152 1. Add a pointer-alignment field to S.
153
154 Assigning a receiver, argument, or result V of underlying type T works
155 as follows:
156
157 1. Remember I and FP.
158 1. If T has zero size, add T to the stack sequence S and return.
159 1. Try to register-assign V.
160 1. If step 3 failed, reset I and FP to the values from step 1, add T
161 to the stack sequence S, and assign V to this field in S.
162
163 Register-assignment of a value V of underlying type T works as follows:
164
165 1. If T is a boolean or integral type that fits in an integer
166 register, assign V to register I and increment I.
167 1. If T is an integral type that fits in two integer registers, assign
168 the least significant and most significant halves of V to registers
169 I and I+1, respectively, and increment I by 2
170 1. If T is a floating-point type and can be represented without loss
171 of precision in a floating-point register, assign V to register FP
172 and increment FP.
173 1. If T is a complex type, recursively register-assign its real and
174 imaginary parts.
175 1. If T is a pointer type, map type, channel type, or function type,
176 assign V to register I and increment I.
177 1. If T is a string type, interface type, or slice type, recursively
178 register-assign V’s components (2 for strings and interfaces, 3 for
179 slices).
180 1. If T is a struct type, recursively register-assign each field of V.
181 1. If T is an array type of length 0, do nothing.
182 1. If T is an array type of length 1, recursively register-assign its
183 one element.
184 1. If T is an array type of length > 1, fail.
185 1. If I > NI or FP > NFP, fail.
186 1. If any recursive assignment above fails, fail.
187
188 The above algorithm produces an assignment of each receiver, argument,
189 and result to registers or to a field in the stack sequence.
190 The final stack sequence looks like: stack-assigned receiver,
191 stack-assigned arguments, pointer-alignment, stack-assigned results,
192 pointer-alignment, spill space for each register-assigned argument,
193 pointer-alignment.
194 The following diagram shows what this stack frame looks like on the
195 stack, using the typical convention where address 0 is at the bottom:
196
197 +------------------------------+
198 | . . . |
199 | 2nd reg argument spill space |
200 | 1st reg argument spill space |
201 | <pointer-sized alignment> |
202 | . . . |
203 | 2nd stack-assigned result |
204 | 1st stack-assigned result |
205 | <pointer-sized alignment> |
206 | . . . |
207 | 2nd stack-assigned argument |
208 | 1st stack-assigned argument |
209 | stack-assigned receiver |
210 +------------------------------+ ↓ lower addresses
211
212 To perform a call, the caller reserves space starting at the lowest
213 address in its stack frame for the call stack frame, stores arguments
214 in the registers and argument stack fields determined by the above
215 algorithm, and performs the call.
216 At the time of a call, spill space, result stack fields, and result
217 registers are left uninitialized.
218 Upon return, the callee must have stored results to all result
219 registers and result stack fields determined by the above algorithm.
220
221 There are no callee-save registers, so a call may overwrite any
222 register that doesn’t have a fixed meaning, including argument
223 registers.
224
225 ### Example
226
227 Consider the function `func f(a1 uint8, a2 [2]uintptr, a3 uint8) (r1
228 struct { x uintptr; y [2]uintptr }, r2 string)` on a 64-bit
229 architecture with hypothetical integer registers R0–R9.
230
231 On entry, `a1` is assigned to `R0`, `a3` is assigned to `R1` and the
232 stack frame is laid out in the following sequence:
233
234 a2 [2]uintptr
235 r1.x uintptr
236 r1.y [2]uintptr
237 a1Spill uint8
238 a3Spill uint8
239 _ [6]uint8 // alignment padding
240
241 In the stack frame, only the `a2` field is initialized on entry; the
242 rest of the frame is left uninitialized.
243
244 On exit, `r2.base` is assigned to `R0`, `r2.len` is assigned to `R1`,
245 and `r1.x` and `r1.y` are initialized in the stack frame.
246
247 There are several things to note in this example.
248 First, `a2` and `r1` are stack-assigned because they contain arrays.
249 The other arguments and results are register-assigned.
250 Result `r2` is decomposed into its components, which are individually
251 register-assigned.
252 On the stack, the stack-assigned arguments appear at lower addresses
253 than the stack-assigned results, which appear at lower addresses than
254 the argument spill area.
255 Only arguments, not results, are assigned a spill area on the stack.
256
257 ### Rationale
258
259 Each base value is assigned to its own register to optimize
260 construction and access.
261 An alternative would be to pack multiple sub-word values into
262 registers, or to simply map an argument's in-memory layout to
263 registers (this is common in C ABIs), but this typically adds cost to
264 pack and unpack these values.
265 Modern architectures have more than enough registers to pass all
266 arguments and results this way for nearly all functions (see the
267 appendix), so there’s little downside to spreading base values across
268 registers.
269
270 Arguments that can’t be fully assigned to registers are passed
271 entirely on the stack in case the callee takes the address of that
272 argument.
273 If an argument could be split across the stack and registers and the
274 callee took its address, it would need to be reconstructed in memory,
275 a process that would be proportional to the size of the argument.
276
277 Non-trivial arrays are always passed on the stack because indexing
278 into an array typically requires a computed offset, which generally
279 isn’t possible with registers.
280 Arrays in general are rare in function signatures (only 0.7% of
281 functions in the Go 1.15 standard library and 0.2% in kubelet).
282 We considered allowing array fields to be passed on the stack while
283 the rest of an argument’s fields are passed in registers, but this
284 creates the same problems as other large structs if the callee takes
285 the address of an argument, and would benefit <0.1% of functions in
286 kubelet (and even these very little).
287
288 We make exceptions for 0 and 1-element arrays because these don’t
289 require computed offsets, and 1-element arrays are already decomposed
290 in the compiler’s SSA representation.
291
292 The ABI assignment algorithm above is equivalent to Go’s stack-based
293 ABI0 calling convention if there are zero architecture registers.
294 This is intended to ease the transition to the register-based internal
295 ABI and make it easy for the compiler to generate either calling
296 convention.
297 An architecture may still define register meanings that aren’t
298 compatible with ABI0, but these differences should be easy to account
299 for in the compiler.
300
301 The assignment algorithm assigns zero-sized values to the stack
302 (assignment step 2) in order to support ABI0-equivalence.
303 While these values take no space themselves, they do result in
304 alignment padding on the stack in ABI0.
305 Without this step, the internal ABI would register-assign zero-sized
306 values even on architectures that provide no argument registers
307 because they don't consume any registers, and hence not add alignment
308 padding to the stack.
309
310 The algorithm reserves spill space for arguments in the caller’s frame
311 so that the compiler can generate a stack growth path that spills into
312 this reserved space.
313 If the callee has to grow the stack, it may not be able to reserve
314 enough additional stack space in its own frame to spill these, which
315 is why it’s important that the caller do so.
316 These slots also act as the home location if these arguments need to
317 be spilled for any other reason, which simplifies traceback printing.
318
319 There are several options for how to lay out the argument spill space.
320 We chose to lay out each argument according to its type's usual memory
321 layout but to separate the spill space from the regular argument
322 space.
323 Using the usual memory layout simplifies the compiler because it
324 already understands this layout.
325 Also, if a function takes the address of a register-assigned argument,
326 the compiler must spill that argument to memory in its usual memory
327 layout and it's more convenient to use the argument spill space for
328 this purpose.
329
330 Alternatively, the spill space could be structured around argument
331 registers.
332 In this approach, the stack growth spill path would spill each
333 argument register to a register-sized stack word.
334 However, if the function takes the address of a register-assigned
335 argument, the compiler would have to reconstruct it in memory layout
336 elsewhere on the stack.
337
338 The spill space could also be interleaved with the stack-assigned
339 arguments so the arguments appear in order whether they are register-
340 or stack-assigned.
341 This would be close to ABI0, except that register-assigned arguments
342 would be uninitialized on the stack and there's no need to reserve
343 stack space for register-assigned results.
344 We expect separating the spill space to perform better because of
345 memory locality.
346 Separating the space is also potentially simpler for `reflect` calls
347 because this allows `reflect` to summarize the spill space as a single
348 number.
349 Finally, the long-term intent is to remove reserved spill slots
350 entirely – allowing most functions to be called without any stack
351 setup and easing the introduction of callee-save registers – and
352 separating the spill space makes that transition easier.
353
354 ## Closures
355
356 A func value (e.g., `var x func()`) is a pointer to a closure object.
357 A closure object begins with a pointer-sized program counter
358 representing the entry point of the function, followed by zero or more
359 bytes containing the closed-over environment.
360
361 Closure calls follow the same conventions as static function and
362 method calls, with one addition. Each architecture specifies a
363 *closure context pointer* register and calls to closures store the
364 address of the closure object in the closure context pointer register
365 prior to the call.
366
367 ## Software floating-point mode
368
369 In "softfloat" mode, the ABI simply treats the hardware as having zero
370 floating-point registers.
371 As a result, any arguments containing floating-point values will be
372 passed on the stack.
373
374 *Rationale*: Softfloat mode is about compatibility over performance
375 and is not commonly used.
376 Hence, we keep the ABI as simple as possible in this case, rather than
377 adding additional rules for passing floating-point values in integer
378 registers.
379
380 ## Architecture specifics
381
382 This section describes per-architecture register mappings, as well as
383 other per-architecture special cases.
384
385 ### amd64 architecture
386
387 The amd64 architecture uses the following sequence of 9 registers for
388 integer arguments and results:
389
390 RAX, RBX, RCX, RDI, RSI, R8, R9, R10, R11
391
392 It uses X0 – X14 for floating-point arguments and results.
393
394 *Rationale*: These sequences are chosen from the available registers
395 to be relatively easy to remember.
396
397 Registers R12 and R13 are permanent scratch registers.
398 R15 is a scratch register except in dynamically linked binaries.
399
400 *Rationale*: Some operations such as stack growth and reflection calls
401 need dedicated scratch registers in order to manipulate call frames
402 without corrupting arguments or results.
403
404 Special-purpose registers are as follows:
405
406 | Register | Call meaning | Return meaning | Body meaning |
407 | --- | --- | --- | --- |
408 | RSP | Stack pointer | Same | Same |
409 | RBP | Frame pointer | Same | Same |
410 | RDX | Closure context pointer | Scratch | Scratch |
411 | R12 | Scratch | Scratch | Scratch |
412 | R13 | Scratch | Scratch | Scratch |
413 | R14 | Current goroutine | Same | Same |
414 | R15 | GOT reference temporary if dynlink | Same | Same |
415 | X15 | Zero value (*) | Same | Scratch |
416
417 (*) Except on Plan 9, where X15 is a scratch register because SSE
418 registers cannot be used in note handlers (so the compiler avoids
419 using them except when absolutely necessary).
420
421 *Rationale*: These register meanings are compatible with Go’s
422 stack-based calling convention except for R14 and X15, which will have
423 to be restored on transitions from ABI0 code to ABIInternal code.
424 In ABI0, these are undefined, so transitions from ABIInternal to ABI0
425 can ignore these registers.
426
427 *Rationale*: For the current goroutine pointer, we chose a register
428 that requires an additional REX byte.
429 While this adds one byte to every function prologue, it is hardly ever
430 accessed outside the function prologue and we expect making more
431 single-byte registers available to be a net win.
432
433 *Rationale*: We could allow R14 (the current goroutine pointer) to be
434 a scratch register in function bodies because it can always be
435 restored from TLS on amd64.
436 However, we designate it as a fixed register for simplicity and for
437 consistency with other architectures that may not have a copy of the
438 current goroutine pointer in TLS.
439
440 *Rationale*: We designate X15 as a fixed zero register because
441 functions often have to bulk zero their stack frames, and this is more
442 efficient with a designated zero register.
443
444 *Implementation note*: Registers with fixed meaning at calls but not
445 in function bodies must be initialized by "injected" calls such as
446 signal-based panics.
447
448 #### Stack layout
449
450 The stack pointer, RSP, grows down and is always aligned to 8 bytes.
451
452 The amd64 architecture does not use a link register.
453
454 A function's stack frame is laid out as follows:
455
456 +------------------------------+
457 | return PC |
458 | RBP on entry |
459 | ... locals ... |
460 | ... outgoing arguments ... |
461 +------------------------------+ ↓ lower addresses
462
463 The "return PC" is pushed as part of the standard amd64 `CALL`
464 operation.
465 On entry, a function subtracts from RSP to open its stack frame and
466 saves the value of RBP directly below the return PC.
467 A leaf function that does not require any stack space may omit the
468 saved RBP.
469
470 The Go ABI's use of RBP as a frame pointer register is compatible with
471 amd64 platform conventions so that Go can inter-operate with platform
472 debuggers and profilers.
473
474 #### Flags
475
476 The direction flag (D) is always cleared (set to the “forward”
477 direction) at a call.
478 The arithmetic status flags are treated like scratch registers and not
479 preserved across calls.
480 All other bits in RFLAGS are system flags.
481
482 At function calls and returns, the CPU is in x87 mode (not MMX
483 technology mode).
484
485 *Rationale*: Go on amd64 does not use either the x87 registers or MMX
486 registers. Hence, we follow the SysV platform conventions in order to
487 simplify transitions to and from the C ABI.
488
489 At calls, the MXCSR control bits are always set as follows:
490
491 | Flag | Bit | Value | Meaning |
492 | --- | --- | --- | --- |
493 | FZ | 15 | 0 | Do not flush to zero |
494 | RC | 14/13 | 0 (RN) | Round to nearest |
495 | PM | 12 | 1 | Precision masked |
496 | UM | 11 | 1 | Underflow masked |
497 | OM | 10 | 1 | Overflow masked |
498 | ZM | 9 | 1 | Divide-by-zero masked |
499 | DM | 8 | 1 | Denormal operations masked |
500 | IM | 7 | 1 | Invalid operations masked |
501 | DAZ | 6 | 0 | Do not zero de-normals |
502
503 The MXCSR status bits are callee-save.
504
505 *Rationale*: Having a fixed MXCSR control configuration allows Go
506 functions to use SSE operations without modifying or saving the MXCSR.
507 Functions are allowed to modify it between calls (as long as they
508 restore it), but as of this writing Go code never does.
509 The above fixed configuration matches the process initialization
510 control bits specified by the ELF AMD64 ABI.
511
512 The x87 floating-point control word is not used by Go on amd64.
513
514 ### arm64 architecture
515
516 The arm64 architecture uses R0 – R15 for integer arguments and results.
517
518 It uses F0 – F15 for floating-point arguments and results.
519
520 *Rationale*: 16 integer registers and 16 floating-point registers are
521 more than enough for passing arguments and results for practically all
522 functions (see Appendix). While there are more registers available,
523 using more registers provides little benefit. Additionally, it will add
524 overhead on code paths where the number of arguments are not statically
525 known (e.g. reflect call), and will consume more stack space when there
526 is only limited stack space available to fit in the nosplit limit.
527
528 Registers R16 and R17 are permanent scratch registers. They are also
529 used as scratch registers by the linker (Go linker and external
530 linker) in trampolines.
531
532 Register R18 is reserved and never used. It is reserved for the OS
533 on some platforms (e.g. macOS).
534
535 Registers R19 – R25 are permanent scratch registers. In addition,
536 R27 is a permanent scratch register used by the assembler when
537 expanding instructions.
538
539 Floating-point registers F16 – F31 are also permanent scratch
540 registers.
541
542 Special-purpose registers are as follows:
543
544 | Register | Call meaning | Return meaning | Body meaning |
545 | --- | --- | --- | --- |
546 | RSP | Stack pointer | Same | Same |
547 | R30 | Link register | Same | Scratch (non-leaf functions) |
548 | R29 | Frame pointer | Same | Same |
549 | R28 | Current goroutine | Same | Same |
550 | R27 | Scratch | Scratch | Scratch |
551 | R26 | Closure context pointer | Scratch | Scratch |
552 | R18 | Reserved (not used) | Same | Same |
553 | ZR | Zero value | Same | Same |
554
555 *Rationale*: These register meanings are compatible with Go’s
556 stack-based calling convention.
557
558 *Rationale*: The link register, R30, holds the function return
559 address at the function entry. For functions that have frames
560 (including most non-leaf functions), R30 is saved to stack in the
561 function prologue and restored in the epilogue. Within the function
562 body, R30 can be used as a scratch register.
563
564 *Implementation note*: Registers with fixed meaning at calls but not
565 in function bodies must be initialized by "injected" calls such as
566 signal-based panics.
567
568 #### Stack layout
569
570 The stack pointer, RSP, grows down and is always aligned to 16 bytes.
571
572 *Rationale*: The arm64 architecture requires the stack pointer to be
573 16-byte aligned.
574
575 A function's stack frame, after the frame is created, is laid out as
576 follows:
577
578 +------------------------------+
579 | ... locals ... |
580 | ... outgoing arguments ... |
581 | return PC | ← RSP points to
582 | frame pointer on entry |
583 +------------------------------+ ↓ lower addresses
584
585 The "return PC" is loaded to the link register, R30, as part of the
586 arm64 `CALL` operation.
587
588 On entry, a function subtracts from RSP to open its stack frame, and
589 saves the values of R30 and R29 at the bottom of the frame.
590 Specifically, R30 is saved at 0(RSP) and R29 is saved at -8(RSP),
591 after RSP is updated.
592
593 A leaf function that does not require any stack space may omit the
594 saved R30 and R29.
595
596 The Go ABI's use of R29 as a frame pointer register is compatible with
597 arm64 architecture requirement so that Go can inter-operate with platform
598 debuggers and profilers.
599
600 This stack layout is used by both register-based (ABIInternal) and
601 stack-based (ABI0) calling conventions.
602
603 #### Flags
604
605 The arithmetic status flags (NZCV) are treated like scratch registers
606 and not preserved across calls.
607 All other bits in PSTATE are system flags and are not modified by Go.
608
609 The floating-point status register (FPSR) is treated like scratch
610 registers and not preserved across calls.
611
612 At calls, the floating-point control register (FPCR) bits are always
613 set as follows:
614
615 | Flag | Bit | Value | Meaning |
616 | --- | --- | --- | --- |
617 | DN | 25 | 0 | Propagate NaN operands |
618 | FZ | 24 | 0 | Do not flush to zero |
619 | RC | 23/22 | 0 (RN) | Round to nearest, choose even if tied |
620 | IDE | 15 | 0 | Denormal operations trap disabled |
621 | IXE | 12 | 0 | Inexact trap disabled |
622 | UFE | 11 | 0 | Underflow trap disabled |
623 | OFE | 10 | 0 | Overflow trap disabled |
624 | DZE | 9 | 0 | Divide-by-zero trap disabled |
625 | IOE | 8 | 0 | Invalid operations trap disabled |
626 | NEP | 2 | 0 | Scalar operations do not affect higher elements in vector registers |
627 | AH | 1 | 0 | No alternate handling of de-normal inputs |
628 | FIZ | 0 | 0 | Do not zero de-normals |
629
630 *Rationale*: Having a fixed FPCR control configuration allows Go
631 functions to use floating-point and vector (SIMD) operations without
632 modifying or saving the FPCR.
633 Functions are allowed to modify it between calls (as long as they
634 restore it), but as of this writing Go code never does.
635
636 ### loong64 architecture
637
638 The loong64 architecture uses R4 – R19 for integer arguments and integer results.
639
640 It uses F0 – F15 for floating-point arguments and results.
641
642 Registers R20 - R21, R23 – R28, R30 - R31, F16 – F31 are permanent scratch registers.
643
644 Register R2 is reserved and never used.
645
646 Register R20, R21 is Used by runtime.duffcopy, runtime.duffzero.
647
648 Special-purpose registers used within Go generated code and Go assembly code
649 are as follows:
650
651 | Register | Call meaning | Return meaning | Body meaning |
652 | --- | --- | --- | --- |
653 | R0 | Zero value | Same | Same |
654 | R1 | Link register | Link register | Scratch |
655 | R3 | Stack pointer | Same | Same |
656 | R20,R21 | Scratch | Scratch | Used by duffcopy, duffzero |
657 | R22 | Current goroutine | Same | Same |
658 | R29 | Closure context pointer | Same | Same |
659 | R30, R31 | used by the assembler | Same | Same |
660
661 *Rationale*: These register meanings are compatible with Go’s stack-based
662 calling convention.
663
664 #### Stack layout
665
666 The stack pointer, R3, grows down and is aligned to 8 bytes.
667
668 A function's stack frame, after the frame is created, is laid out as
669 follows:
670
671 +------------------------------+
672 | ... locals ... |
673 | ... outgoing arguments ... |
674 | return PC | ← R3 points to
675 +------------------------------+ ↓ lower addresses
676
677 This stack layout is used by both register-based (ABIInternal) and
678 stack-based (ABI0) calling conventions.
679
680 The "return PC" is loaded to the link register, R1, as part of the
681 loong64 `JAL` operation.
682
683 #### Flags
684 All bits in CSR are system flags and are not modified by Go.
685
686 ### ppc64 architecture
687
688 The ppc64 architecture uses R3 – R10 and R14 – R17 for integer arguments
689 and results.
690
691 It uses F1 – F12 for floating-point arguments and results.
692
693 Register R31 is a permanent scratch register in Go.
694
695 Special-purpose registers used within Go generated code and Go
696 assembly code are as follows:
697
698 | Register | Call meaning | Return meaning | Body meaning |
699 | --- | --- | --- | --- |
700 | R0 | Zero value | Same | Same |
701 | R1 | Stack pointer | Same | Same |
702 | R2 | TOC register | Same | Same |
703 | R11 | Closure context pointer | Scratch | Scratch |
704 | R12 | Function address on indirect calls | Scratch | Scratch |
705 | R13 | TLS pointer | Same | Same |
706 | R20,R21 | Scratch | Scratch | Used by duffcopy, duffzero |
707 | R30 | Current goroutine | Same | Same |
708 | R31 | Scratch | Scratch | Scratch |
709 | LR | Link register | Link register | Scratch |
710 *Rationale*: These register meanings are compatible with Go’s
711 stack-based calling convention.
712
713 The link register, LR, holds the function return
714 address at the function entry and is set to the correct return
715 address before exiting the function. It is also used
716 in some cases as the function address when doing an indirect call.
717
718 The register R2 contains the address of the TOC (table of contents) which
719 contains data or code addresses used when generating position independent
720 code. Non-Go code generated when using cgo contains TOC-relative addresses
721 which depend on R2 holding a valid TOC. Go code compiled with -shared or
722 -dynlink initializes and maintains R2 and uses it in some cases for
723 function calls; Go code compiled without these options does not modify R2.
724
725 When making a function call R12 contains the function address for use by the
726 code to generate R2 at the beginning of the function. R12 can be used for
727 other purposes within the body of the function, such as trampoline generation.
728
729 R20 and R21 are used in duffcopy and duffzero which could be generated
730 before arguments are saved so should not be used for register arguments.
731
732 The Count register CTR can be used as the call target for some branch instructions.
733 It holds the return address when preemption has occurred.
734
735 On PPC64 when a float32 is loaded it becomes a float64 in the register, which is
736 different from other platforms and that needs to be recognized by the internal
737 implementation of reflection so that float32 arguments are passed correctly.
738
739 Registers R18 - R29 and F13 - F31 are considered scratch registers.
740
741 #### Stack layout
742
743 The stack pointer, R1, grows down and is aligned to 8 bytes in Go, but changed
744 to 16 bytes when calling cgo.
745
746 A function's stack frame, after the frame is created, is laid out as
747 follows:
748
749 +------------------------------+
750 | ... locals ... |
751 | ... outgoing arguments ... |
752 | 24 TOC register R2 save | When compiled with -shared/-dynlink
753 | 16 Unused in Go | Not used in Go
754 | 8 CR save | nonvolatile CR fields
755 | 0 return PC | ← R1 points to
756 +------------------------------+ ↓ lower addresses
757
758 The "return PC" is loaded to the link register, LR, as part of the
759 ppc64 `BL` operations.
760
761 On entry to a non-leaf function, the stack frame size is subtracted from R1 to
762 create its stack frame, and saves the value of LR at the bottom of the frame.
763
764 A leaf function that does not require any stack space does not modify R1 and
765 does not save LR.
766
767 *NOTE*: We might need to save the frame pointer on the stack as
768 in the PPC64 ELF v2 ABI so Go can inter-operate with platform debuggers
769 and profilers.
770
771 This stack layout is used by both register-based (ABIInternal) and
772 stack-based (ABI0) calling conventions.
773
774 #### Flags
775
776 The condition register consists of 8 condition code register fields
777 CR0-CR7. Go generated code only sets and uses CR0, commonly set by
778 compare functions and use to determine the target of a conditional
779 branch. The generated code does not set or use CR1-CR7.
780
781 The floating point status and control register (FPSCR) is initialized
782 to 0 by the kernel at startup of the Go program and not changed by
783 the Go generated code.
784
785 ### riscv64 architecture
786
787 The riscv64 architecture uses X10 – X17, X8, X9, X18 – X23 for integer arguments
788 and results.
789
790 It uses F10 – F17, F8, F9, F18 – F23 for floating-point arguments and results.
791
792 Special-purpose registers used within Go generated code and Go
793 assembly code are as follows:
794
795 | Register | Call meaning | Return meaning | Body meaning |
796 | --- | --- | --- | --- |
797 | X0 | Zero value | Same | Same |
798 | X1 | Link register | Link register | Scratch |
799 | X2 | Stack pointer | Same | Same |
800 | X3 | Global pointer | Same | Used by dynamic linker |
801 | X4 | TLS (thread pointer) | TLS | Scratch |
802 | X26 | Closure context pointer | Scratch | Scratch |
803 | X27 | Current goroutine | Same | Same |
804 | X31 | Scratch | Scratch | Scratch |
805
806 *Rationale*: These register meanings are compatible with Go’s
807 stack-based calling convention.
808 X10 – X17, X8, X9, X18 – X23, is the same order as A0 – A7, S0 – S7 in platform ABI.
809 F10 – F17, F8, F9, F18 – F23, is the same order as FA0 – FA7, FS0 – FS7 in platform ABI.
810 X8 – X23, F8 – F15 are used for compressed instruction (RVC) which benefits code size.
811
812 #### Stack layout
813
814 The stack pointer, X2, grows down and is aligned to 8 bytes.
815
816 A function's stack frame, after the frame is created, is laid out as
817 follows:
818
819 +------------------------------+
820 | ... locals ... |
821 | ... outgoing arguments ... |
822 | return PC | ← X2 points to
823 +------------------------------+ ↓ lower addresses
824
825 The "return PC" is loaded to the link register, X1, as part of the
826 riscv64 `CALL` operation.
827
828 #### Flags
829
830 The riscv64 has Zicsr extension for control and status register (CSR) and
831 treated as scratch register.
832 All bits in CSR are system flags and are not modified by Go.
833
834 ### s390x architecture
835
836 The s390x architecture uses R2 – R9 for integer arguments and integer results.
837
838 It uses F0 – F15 for floating-point arguments and results.
839
840 Special-purpose registers used within Go generated code and Go assembly code
841 are as follows:
842
843 | Register | Call meaning | Return meaning | Body meaning |
844 | --- | --- | --- | --- |
845 | R0 | Zero value | Same | Same |
846 | R1 | Scratch | Scratch | Scratch |
847 | R10, R11 | used by the assembler | Same | Same |
848 | R12 | Closure context pointer | Same | Same |
849 | R13 | Current goroutine | Same | Same |
850 | R14 | Link register | Link register | Scratch |
851 | R15 | Stack pointer | Same | Same |
852
853 *Rationale*: These register meanings are compatible with Go’s stack-based
854 calling convention.
855
856 #### Stack layout
857
858 The stack pointer, R15, grows down and is aligned to 8 bytes.
859
860 A function's stack frame, after the frame is created, is laid out as
861 follows:
862
863 +------------------------------+
864 | ... locals ... |
865 | ... outgoing arguments ... |
866 | return PC | ← R15 points to
867 +------------------------------+ ↓ lower addresses
868
869 This stack layout is used by both register-based (ABIInternal) and
870 stack-based (ABI0) calling conventions.
871
872 The "return PC" is loaded to the link register R14, as part of the
873 s390x `BL` operation.
874
875 #### Flags
876 The s390x architecture maintains a single condition code (CC) field in the Program Status Word (PSW).
877 Go-generated code sets and tests this condition code to control conditional branches.
878
879 ## Future directions
880
881 ### Spill path improvements
882
883 The ABI currently reserves spill space for argument registers so the
884 compiler can statically generate an argument spill path before calling
885 into `runtime.morestack` to grow the stack.
886 This ensures there will be sufficient spill space even when the stack
887 is nearly exhausted and keeps stack growth and stack scanning
888 essentially unchanged from ABI0.
889
890 However, this wastes stack space (the median wastage is 16 bytes per
891 call), resulting in larger stacks and increased cache footprint.
892 A better approach would be to reserve stack space only when spilling.
893 One way to ensure enough space is available to spill would be for
894 every function to ensure there is enough space for the function's own
895 frame *as well as* the spill space of all functions it calls.
896 For most functions, this would change the threshold for the prologue
897 stack growth check.
898 For `nosplit` functions, this would change the threshold used in the
899 linker's static stack size check.
900
901 Allocating spill space in the callee rather than the caller may also
902 allow for faster reflection calls in the common case where a function
903 takes only register arguments, since it would allow reflection to make
904 these calls directly without allocating any frame.
905
906 The statically-generated spill path also increases code size.
907 It is possible to instead have a generic spill path in the runtime, as
908 part of `morestack`.
909 However, this complicates reserving the spill space, since spilling
910 all possible register arguments would, in most cases, take
911 significantly more space than spilling only those used by a particular
912 function.
913 Some options are to spill to a temporary space and copy back only the
914 registers used by the function, or to grow the stack if necessary
915 before spilling to it (using a temporary space if necessary), or to
916 use a heap-allocated space if insufficient stack space is available.
917 These options all add enough complexity that we will have to make this
918 decision based on the actual code size growth caused by the static
919 spill paths.
920
921 ### Clobber sets
922
923 As defined, the ABI does not use callee-save registers.
924 This significantly simplifies the garbage collector and the compiler's
925 register allocator, but at some performance cost.
926 A potentially better balance for Go code would be to use *clobber
927 sets*: for each function, the compiler records the set of registers it
928 clobbers (including those clobbered by functions it calls) and any
929 register not clobbered by function F can remain live across calls to
930 F.
931
932 This is generally a good fit for Go because Go's package DAG allows
933 function metadata like the clobber set to flow up the call graph, even
934 across package boundaries.
935 Clobber sets would require relatively little change to the garbage
936 collector, unlike general callee-save registers.
937 One disadvantage of clobber sets over callee-save registers is that
938 they don't help with indirect function calls or interface method
939 calls, since static information isn't available in these cases.
940
941 ### Large aggregates
942
943 Go encourages passing composite values by value, and this simplifies
944 reasoning about mutation and races.
945 However, this comes at a performance cost for large composite values.
946 It may be possible to instead transparently pass large composite
947 values by reference and delay copying until it is actually necessary.
948
949 ## Appendix: Register usage analysis
950
951 In order to understand the impacts of the above design on register
952 usage, we
953 [analyzed](https://github.com/aclements/go-misc/tree/master/abi) the
954 impact of the above ABI on a large code base: cmd/kubelet from
955 [Kubernetes](https://github.com/kubernetes/kubernetes) at tag v1.18.8.
956
957 The following table shows the impact of different numbers of available
958 integer and floating-point registers on argument assignment:
959
960 ```
961 | | | | stack args | spills | stack total |
962 | ints | floats | % fit | p50 | p95 | p99 | p50 | p95 | p99 | p50 | p95 | p99 |
963 | 0 | 0 | 6.3% | 32 | 152 | 256 | 0 | 0 | 0 | 32 | 152 | 256 |
964 | 0 | 8 | 6.4% | 32 | 152 | 256 | 0 | 0 | 0 | 32 | 152 | 256 |
965 | 1 | 8 | 21.3% | 24 | 144 | 248 | 8 | 8 | 8 | 32 | 152 | 256 |
966 | 2 | 8 | 38.9% | 16 | 128 | 224 | 8 | 16 | 16 | 24 | 136 | 240 |
967 | 3 | 8 | 57.0% | 0 | 120 | 224 | 16 | 24 | 24 | 24 | 136 | 240 |
968 | 4 | 8 | 73.0% | 0 | 120 | 216 | 16 | 32 | 32 | 24 | 136 | 232 |
969 | 5 | 8 | 83.3% | 0 | 112 | 216 | 16 | 40 | 40 | 24 | 136 | 232 |
970 | 6 | 8 | 87.5% | 0 | 112 | 208 | 16 | 48 | 48 | 24 | 136 | 232 |
971 | 7 | 8 | 89.8% | 0 | 112 | 208 | 16 | 48 | 56 | 24 | 136 | 232 |
972 | 8 | 8 | 91.3% | 0 | 112 | 200 | 16 | 56 | 64 | 24 | 136 | 232 |
973 | 9 | 8 | 92.1% | 0 | 112 | 192 | 16 | 56 | 72 | 24 | 136 | 232 |
974 | 10 | 8 | 92.6% | 0 | 104 | 192 | 16 | 56 | 72 | 24 | 136 | 232 |
975 | 11 | 8 | 93.1% | 0 | 104 | 184 | 16 | 56 | 80 | 24 | 128 | 232 |
976 | 12 | 8 | 93.4% | 0 | 104 | 176 | 16 | 56 | 88 | 24 | 128 | 232 |
977 | 13 | 8 | 94.0% | 0 | 88 | 176 | 16 | 56 | 96 | 24 | 128 | 232 |
978 | 14 | 8 | 94.4% | 0 | 80 | 152 | 16 | 64 | 104 | 24 | 128 | 232 |
979 | 15 | 8 | 94.6% | 0 | 80 | 152 | 16 | 64 | 112 | 24 | 128 | 232 |
980 | 16 | 8 | 94.9% | 0 | 16 | 152 | 16 | 64 | 112 | 24 | 128 | 232 |
981 | ∞ | 8 | 99.8% | 0 | 0 | 0 | 24 | 112 | 216 | 24 | 120 | 216 |
982 ```
983
984 The first two columns show the number of available integer and
985 floating-point registers.
986 The first row shows the results for 0 integer and 0 floating-point
987 registers, which is equivalent to ABI0.
988 We found that any reasonable number of floating-point registers has
989 the same effect, so we fixed it at 8 for all other rows.
990
991 The “% fit” column gives the fraction of functions where all arguments
992 and results are register-assigned and no arguments are passed on the
993 stack.
994 The three “stack args” columns give the median, 95th and 99th
995 percentile number of bytes of stack arguments.
996 The “spills” columns likewise summarize the number of bytes in
997 on-stack spill space.
998 And “stack total” summarizes the sum of stack arguments and on-stack
999 spill slots.
1000 Note that these are three different distributions; for example,
1001 there’s no single function that takes 0 stack argument bytes, 16 spill
1002 bytes, and 24 total stack bytes.
1003
1004 From this, we can see that the fraction of functions that fit entirely
1005 in registers grows very slowly once it reaches about 90%, though
1006 curiously there is a small minority of functions that could benefit
1007 from a huge number of registers.
1008 Making 9 integer registers available on amd64 puts it in this realm.
1009 We also see that the stack space required for most functions is fairly
1010 small.
1011 While the increasing space required for spills largely balances out
1012 the decreasing space required for stack arguments as the number of
1013 available registers increases, there is a general reduction in the
1014 total stack space required with more available registers.
1015 This does, however, suggest that eliminating spill slots in the future
1016 would noticeably reduce stack requirements.