Debian Codegraph @

doc/asm.html

raw
1 <!--{
2 "Title": "A Quick Guide to Go's Assembler",
3 "Path": "/doc/asm"
4 }-->
5
6 <h2 id="introduction">A Quick Guide to Go's Assembler</h2>
7
8 <p>
9 This document is a quick outline of the unusual form of assembly language used by the <code>gc</code> Go compiler.
10 The document is not comprehensive.
11 </p>
12
13 <p>
14 The assembler is based on the input style of the Plan 9 assemblers, which is documented in detail
15 <a href="https://9p.io/sys/doc/asm.html">elsewhere</a>.
16 If you plan to write assembly language, you should read that document although much of it is Plan 9-specific.
17 The current document provides a summary of the syntax and the differences with
18 what is explained in that document, and
19 describes the peculiarities that apply when writing assembly code to interact with Go.
20 </p>
21
22 <p>
23 The most important thing to know about Go's assembler is that it is not a direct representation of the underlying machine.
24 Some of the details map precisely to the machine, but some do not.
25 This is because the compiler suite (see
26 <a href="https://9p.io/sys/doc/compiler.html">this description</a>)
27 needs no assembler pass in the usual pipeline.
28 Instead, the compiler operates on a kind of semi-abstract instruction set,
29 and instruction selection occurs partly after code generation.
30 The assembler works on the semi-abstract form, so
31 when you see an instruction like <code>MOV</code>
32 what the toolchain actually generates for that operation might
33 not be a move instruction at all, perhaps a clear or load.
34 Or it might correspond exactly to the machine instruction with that name.
35 In general, machine-specific operations tend to appear as themselves, while more general concepts like
36 memory move and subroutine call and return are more abstract.
37 The details vary with architecture, and we apologize for the imprecision; the situation is not well-defined.
38 </p>
39
40 <p>
41 The assembler program is a way to parse a description of that
42 semi-abstract instruction set and turn it into instructions to be
43 input to the linker.
44 If you want to see what the instructions look like in assembly for a given architecture, say amd64, there
45 are many examples in the sources of the standard library, in packages such as
46 <a href="/pkg/runtime/"><code>runtime</code></a> and
47 <a href="/pkg/math/big/"><code>math/big</code></a>.
48 You can also examine what the compiler emits as assembly code
49 (the actual output may differ from what you see here):
50 </p>
51
52 <pre>
53 $ cat x.go
54 package main
55
56 func main() {
57 println(3)
58 }
59 $ GOOS=linux GOARCH=amd64 go tool compile -S x.go # or: go build -gcflags -S x.go
60 "".main STEXT size=74 args=0x0 locals=0x10
61 0x0000 00000 (x.go:3) TEXT "".main(SB), $16-0
62 0x0000 00000 (x.go:3) MOVQ (TLS), CX
63 0x0009 00009 (x.go:3) CMPQ SP, 16(CX)
64 0x000d 00013 (x.go:3) JLS 67
65 0x000f 00015 (x.go:3) SUBQ $16, SP
66 0x0013 00019 (x.go:3) MOVQ BP, 8(SP)
67 0x0018 00024 (x.go:3) LEAQ 8(SP), BP
68 0x001d 00029 (x.go:3) FUNCDATA $0, gclocals·33cdeccccebe80329f1fdbee7f5874cb(SB)
69 0x001d 00029 (x.go:3) FUNCDATA $1, gclocals·33cdeccccebe80329f1fdbee7f5874cb(SB)
70 0x001d 00029 (x.go:3) FUNCDATA $2, gclocals·33cdeccccebe80329f1fdbee7f5874cb(SB)
71 0x001d 00029 (x.go:4) PCDATA $0, $0
72 0x001d 00029 (x.go:4) PCDATA $1, $0
73 0x001d 00029 (x.go:4) CALL runtime.printlock(SB)
74 0x0022 00034 (x.go:4) MOVQ $3, (SP)
75 0x002a 00042 (x.go:4) CALL runtime.printint(SB)
76 0x002f 00047 (x.go:4) CALL runtime.printnl(SB)
77 0x0034 00052 (x.go:4) CALL runtime.printunlock(SB)
78 0x0039 00057 (x.go:5) MOVQ 8(SP), BP
79 0x003e 00062 (x.go:5) ADDQ $16, SP
80 0x0042 00066 (x.go:5) RET
81 0x0043 00067 (x.go:5) NOP
82 0x0043 00067 (x.go:3) PCDATA $1, $-1
83 0x0043 00067 (x.go:3) PCDATA $0, $-1
84 0x0043 00067 (x.go:3) CALL runtime.morestack_noctxt(SB)
85 0x0048 00072 (x.go:3) JMP 0
86 ...
87 </pre>
88
89 <p>
90 The <code>FUNCDATA</code> and <code>PCDATA</code> directives contain information
91 for use by the garbage collector; they are introduced by the compiler.
92 </p>
93
94 <p>
95 To see what gets put in the binary after linking, use <code>go tool objdump</code>:
96 </p>
97
98 <pre>
99 $ go build -o x.exe x.go
100 $ go tool objdump -s main.main x.exe
101 TEXT main.main(SB) /tmp/x.go
102 x.go:3 0x10501c0 65488b0c2530000000 MOVQ GS:0x30, CX
103 x.go:3 0x10501c9 483b6110 CMPQ 0x10(CX), SP
104 x.go:3 0x10501cd 7634 JBE 0x1050203
105 x.go:3 0x10501cf 4883ec10 SUBQ $0x10, SP
106 x.go:3 0x10501d3 48896c2408 MOVQ BP, 0x8(SP)
107 x.go:3 0x10501d8 488d6c2408 LEAQ 0x8(SP), BP
108 x.go:4 0x10501dd e86e45fdff CALL runtime.printlock(SB)
109 x.go:4 0x10501e2 48c7042403000000 MOVQ $0x3, 0(SP)
110 x.go:4 0x10501ea e8e14cfdff CALL runtime.printint(SB)
111 x.go:4 0x10501ef e8ec47fdff CALL runtime.printnl(SB)
112 x.go:4 0x10501f4 e8d745fdff CALL runtime.printunlock(SB)
113 x.go:5 0x10501f9 488b6c2408 MOVQ 0x8(SP), BP
114 x.go:5 0x10501fe 4883c410 ADDQ $0x10, SP
115 x.go:5 0x1050202 c3 RET
116 x.go:3 0x1050203 e83882ffff CALL runtime.morestack_noctxt(SB)
117 x.go:3 0x1050208 ebb6 JMP main.main(SB)
118 </pre>
119
120 <h3 id="constants">Constants</h3>
121
122 <p>
123 Although the assembler takes its guidance from the Plan 9 assemblers,
124 it is a distinct program, so there are some differences.
125 One is in constant evaluation.
126 Constant expressions in the assembler are parsed using Go's operator
127 precedence, not the C-like precedence of the original.
128 Thus <code>3&amp;1&lt;&lt;2</code> is 4, not 0—it parses as <code>(3&amp;1)&lt;&lt;2</code>
129 not <code>3&amp;(1&lt;&lt;2)</code>.
130 Also, constants are always evaluated as 64-bit unsigned integers.
131 Thus <code>-2</code> is not the integer value minus two,
132 but the unsigned 64-bit integer with the same bit pattern.
133 The distinction rarely matters but
134 to avoid ambiguity, division or right shift where the right operand's
135 high bit is set is rejected.
136 </p>
137
138 <h3 id="symbols">Symbols</h3>
139
140 <p>
141 Some symbols, such as <code>R1</code> or <code>LR</code>,
142 are predefined and refer to registers.
143 The exact set depends on the architecture.
144 </p>
145
146 <p>
147 There are four predeclared symbols that refer to pseudo-registers.
148 These are not real registers, but rather virtual registers maintained by
149 the toolchain, such as a frame pointer.
150 The set of pseudo-registers is the same for all architectures:
151 </p>
152
153 <ul>
154
155 <li>
156 <code>FP</code>: Frame pointer: arguments and locals.
157 </li>
158
159 <li>
160 <code>PC</code>: Program counter:
161 jumps and branches.
162 </li>
163
164 <li>
165 <code>SB</code>: Static base pointer: global symbols.
166 </li>
167
168 <li>
169 <code>SP</code>: Stack pointer: the highest address within the local stack frame.
170 </li>
171
172 </ul>
173
174 <p>
175 All user-defined symbols are written as offsets to the pseudo-registers
176 <code>FP</code> (arguments and locals) and <code>SB</code> (globals).
177 </p>
178
179 <p>
180 The <code>SB</code> pseudo-register can be thought of as the origin of memory, so the symbol <code>foo(SB)</code>
181 is the name <code>foo</code> as an address in memory.
182 This form is used to name global functions and data.
183 Adding <code>&lt;&gt;</code> to the name, as in <span style="white-space: nowrap"><code>foo&lt;&gt;(SB)</code></span>, makes the name
184 visible only in the current source file, like a top-level <code>static</code> declaration in a C file.
185 Adding an offset to the name refers to that offset from the symbol's address, so
186 <code>foo+4(SB)</code> is four bytes past the start of <code>foo</code>.
187 </p>
188
189 <p>
190 The <code>FP</code> pseudo-register is a virtual frame pointer
191 used to refer to function arguments.
192 The compilers maintain a virtual frame pointer and refer to the arguments on the stack as offsets from that pseudo-register.
193 Thus <code>0(FP)</code> is the first argument to the function,
194 <code>8(FP)</code> is the second (on a 64-bit machine), and so on.
195 However, when referring to a function argument this way, it is necessary to place a name
196 at the beginning, as in <code>first_arg+0(FP)</code> and <code>second_arg+8(FP)</code>.
197 (The meaning of the offset—offset from the frame pointer—distinct
198 from its use with <code>SB</code>, where it is an offset from the symbol.)
199 The assembler enforces this convention, rejecting plain <code>0(FP)</code> and <code>8(FP)</code>.
200 The actual name is semantically irrelevant but should be used to document
201 the argument's name.
202 It is worth stressing that <code>FP</code> is always a
203 pseudo-register, not a hardware
204 register, even on architectures with a hardware frame pointer.
205 </p>
206
207 <p>
208 For assembly functions with Go prototypes, <code>go</code> <code>vet</code> will check that the argument names
209 and offsets match.
210 On 32-bit systems, the low and high 32 bits of a 64-bit value are distinguished by adding
211 a <code>_lo</code> or <code>_hi</code> suffix to the name, as in <code>arg_lo+0(FP)</code> or <code>arg_hi+4(FP)</code>.
212 If a Go prototype does not name its result, the expected assembly name is <code>ret</code>.
213 </p>
214
215 <p>
216 The <code>SP</code> pseudo-register is a virtual stack pointer
217 used to refer to frame-local variables and the arguments being
218 prepared for function calls.
219 It points to the highest address within the local stack frame, so references should use negative offsets
220 in the range [−framesize, 0):
221 <code>x-8(SP)</code>, <code>y-4(SP)</code>, and so on.
222 </p>
223
224 <p>
225 On architectures with a hardware register named <code>SP</code>,
226 the name prefix distinguishes
227 references to the virtual stack pointer from references to the architectural
228 <code>SP</code> register.
229 That is, <code>x-8(SP)</code> and <code>-8(SP)</code>
230 are different memory locations:
231 the first refers to the virtual stack pointer pseudo-register,
232 while the second refers to the
233 hardware's <code>SP</code> register.
234 </p>
235
236 <p>
237 On machines where <code>SP</code> and <code>PC</code> are
238 traditionally aliases for a physical, numbered register,
239 in the Go assembler the names <code>SP</code> and <code>PC</code>
240 are still treated specially;
241 for instance, references to <code>SP</code> require a symbol,
242 much like <code>FP</code>.
243 To access the actual hardware register use the true <code>R</code> name.
244 For example, on the ARM architecture the hardware
245 <code>SP</code> and <code>PC</code> are accessible as
246 <code>R13</code> and <code>R15</code>.
247 </p>
248
249 <p>
250 Branches and direct jumps are always written as offsets to the PC, or as
251 jumps to labels:
252 </p>
253
254 <pre>
255 label:
256 MOVW $0, R1
257 JMP label
258 </pre>
259
260 <p>
261 Each label is visible only within the function in which it is defined.
262 It is therefore permitted for multiple functions in a file to define
263 and use the same label names.
264 Direct jumps and call instructions can target text symbols,
265 such as <code>name(SB)</code>, but not offsets from symbols,
266 such as <code>name+4(SB)</code>.
267 </p>
268
269 <p>
270 Instructions, registers, and assembler directives are always in UPPER CASE to remind you
271 that assembly programming is a fraught endeavor.
272 (Exception: the <code>g</code> register renaming on ARM.)
273 </p>
274
275 <p>
276 In Go object files and binaries, the full name of a symbol is the
277 package path followed by a period and the symbol name:
278 <code>fmt.Printf</code> or <code>math/rand.Int</code>.
279 Because the assembler's parser treats period and slash as punctuation,
280 those strings cannot be used directly as identifier names.
281 Instead, the assembler allows the middle dot character U+00B7
282 and the division slash U+2215 in identifiers and rewrites them to
283 plain period and slash.
284 Within an assembler source file, the symbols above are written as
285 <code>fmt·Printf</code> and <code>math∕rand·Int</code>.
286 The assembly listings generated by the compilers when using the <code>-S</code> flag
287 show the period and slash directly instead of the Unicode replacements
288 required by the assemblers.
289 </p>
290
291 <p>
292 Most hand-written assembly files do not include the full package path
293 in symbol names, because the linker inserts the package path of the current
294 object file at the beginning of any name starting with a period:
295 in an assembly source file within the math/rand package implementation,
296 the package's Int function can be referred to as <code>·Int</code>.
297 This convention avoids the need to hard-code a package's import path in its
298 own source code, making it easier to move the code from one location to another.
299 </p>
300
301 <h3 id="directives">Directives</h3>
302
303 <p>
304 The assembler uses various directives to bind text and data to symbol names.
305 For example, here is a simple complete function definition. The <code>TEXT</code>
306 directive declares the symbol <code>runtime·profileloop</code> and the instructions
307 that follow form the body of the function.
308 The last instruction in a <code>TEXT</code> block must be some sort of jump, usually a <code>RET</code> (pseudo-)instruction.
309 (If it's not, the linker will append a jump-to-itself instruction; there is no fallthrough in <code>TEXTs</code>.)
310 After the symbol, the arguments are flags (see below)
311 and the frame size, a constant (but see below):
312 </p>
313
314 <pre>
315 TEXT runtime·profileloop(SB),NOSPLIT,$8
316 MOVQ $runtime·profileloop1(SB), CX
317 MOVQ CX, 0(SP)
318 CALL runtime·externalthreadhandler(SB)
319 RET
320 </pre>
321
322 <p>
323 In the general case, the frame size is followed by an argument size, separated by a minus sign.
324 (It's not a subtraction, just idiosyncratic syntax.)
325 The frame size <code>$24-8</code> states that the function has a 24-byte frame
326 and is called with 8 bytes of argument, which live on the caller's frame.
327 If <code>NOSPLIT</code> is not specified for the <code>TEXT</code>,
328 the argument size must be provided.
329 For assembly functions with Go prototypes, <code>go</code> <code>vet</code> will check that the
330 argument size is correct.
331 </p>
332
333 <p>
334 Note that the symbol name uses a middle dot to separate the components and is specified as an offset from the
335 static base pseudo-register <code>SB</code>.
336 This function would be called from Go source for package <code>runtime</code> using the
337 simple name <code>profileloop</code>.
338 </p>
339
340 <p>
341 Global data symbols are defined by a sequence of initializing
342 <code>DATA</code> directives followed by a <code>GLOBL</code> directive.
343 Each <code>DATA</code> directive initializes a section of the
344 corresponding memory.
345 The memory not explicitly initialized is zeroed.
346 The general form of the <code>DATA</code> directive is
347
348 <pre>
349 DATA symbol+offset(SB)/width, value
350 </pre>
351
352 <p>
353 which initializes the symbol memory at the given offset and width with the given value.
354 The <code>DATA</code> directives for a given symbol must be written with increasing offsets.
355 </p>
356
357 <p>
358 The <code>GLOBL</code> directive declares a symbol to be global.
359 The arguments are optional flags and the size of the data being declared as a global,
360 which will have initial value all zeros unless a <code>DATA</code> directive
361 has initialized it.
362 The <code>GLOBL</code> directive must follow any corresponding <code>DATA</code> directives.
363 </p>
364
365 <p>
366 For example,
367 </p>
368
369 <pre>
370 DATA divtab&lt;&gt;+0x00(SB)/4, $0xf4f8fcff
371 DATA divtab&lt;&gt;+0x04(SB)/4, $0xe6eaedf0
372 ...
373 DATA divtab&lt;&gt;+0x3c(SB)/4, $0x81828384
374 GLOBL divtab&lt;&gt;(SB), RODATA, $64
375
376 GLOBL runtime·tlsoffset(SB), NOPTR, $4
377 </pre>
378
379 <p>
380 declares and initializes <code>divtab&lt;&gt;</code>, a read-only 64-byte table of 4-byte integer values,
381 and declares <code>runtime·tlsoffset</code>, a 4-byte, implicitly zeroed variable that
382 contains no pointers.
383 </p>
384
385 <p>
386 There may be one or two arguments to the directives.
387 If there are two, the first is a bit mask of flags,
388 which can be written as numeric expressions, added or or-ed together,
389 or can be set symbolically for easier absorption by a human.
390 Their values, defined in the standard <code>#include</code> file <code>textflag.h</code>, are:
391 </p>
392
393 <ul>
394 <li>
395 <code>NOPROF</code> = 1
396 <br>
397 (For <code>TEXT</code> items.)
398 Don't profile the marked function. This flag is deprecated.
399 </li>
400 <li>
401 <code>DUPOK</code> = 2
402 <br>
403 It is legal to have multiple instances of this symbol in a single binary.
404 The linker will choose one of the duplicates to use.
405 </li>
406 <li>
407 <code>NOSPLIT</code> = 4
408 <br>
409 (For <code>TEXT</code> items.)
410 Don't insert the preamble to check if the stack must be split.
411 The frame for the routine, plus anything it calls, must fit in the
412 spare space remaining in the current stack segment.
413 Used to protect routines such as the stack splitting code itself.
414 </li>
415 <li>
416 <code>RODATA</code> = 8
417 <br>
418 (For <code>DATA</code> and <code>GLOBL</code> items.)
419 Put this data in a read-only section.
420 </li>
421 <li>
422 <code>NOPTR</code> = 16
423 <br>
424 (For <code>DATA</code> and <code>GLOBL</code> items.)
425 This data contains no pointers and therefore does not need to be
426 scanned by the garbage collector.
427 </li>
428 <li>
429 <code>WRAPPER</code> = 32
430 <br>
431 (For <code>TEXT</code> items.)
432 This is a wrapper function and should not count as disabling <code>recover</code>.
433 </li>
434 <li>
435 <code>NEEDCTXT</code> = 64
436 <br>
437 (For <code>TEXT</code> items.)
438 This function is a closure so it uses its incoming context register.
439 </li>
440 <li>
441 <code>LOCAL</code> = 128
442 <br>
443 This symbol is local to the dynamic shared object.
444 </li>
445 <li>
446 <code>TLSBSS</code> = 256
447 <br>
448 (For <code>DATA</code> and <code>GLOBL</code> items.)
449 Put this data in thread local storage.
450 </li>
451 <li>
452 <code>NOFRAME</code> = 512
453 <br>
454 (For <code>TEXT</code> items.)
455 Do not insert instructions to allocate a stack frame and save/restore the return
456 address, even if this is not a leaf function.
457 Only valid on functions that declare a frame size of 0.
458 </li>
459 <li>
460 <code>TOPFRAME</code> = 2048
461 <br>
462 (For <code>TEXT</code> items.)
463 Function is the outermost frame of the call stack. Traceback should stop at this function.
464 </li>
465 </ul>
466
467 <h3 id="special-instructions">Special instructions</h3>
468
469 <p>
470 The <code>PCALIGN</code> pseudo-instruction is used to indicate that the next instruction should be aligned
471 to a specified boundary by padding with no-op instructions.
472 </p>
473
474 <p>
475 It is currently supported on arm64, amd64, ppc64, loong64 and riscv64.
476
477 For example, the start of the <code>MOVD</code> instruction below is aligned to 32 bytes:
478 <pre>
479 PCALIGN $32
480 MOVD $2, R0
481 </pre>
482 </p>
483
484 <h3 id="data-offsets">Interacting with Go types and constants</h3>
485
486 <p>
487 If a package has any .s files, then <code>go build</code> will direct
488 the compiler to emit a special header called <code>go_asm.h</code>,
489 which the .s files can then <code>#include</code>.
490 The file contains symbolic <code>#define</code> constants for the
491 offsets of Go struct fields, the sizes of Go struct types, and most
492 Go <code>const</code> declarations defined in the current package.
493 Go assembly should avoid making assumptions about the layout of Go
494 types and instead use these constants.
495 This improves the readability of assembly code, and keeps it robust to
496 changes in data layout either in the Go type definitions or in the
497 layout rules used by the Go compiler.
498 </p>
499
500 <p>
501 Constants are of the form <code>const_<i>name</i></code>.
502 For example, given the Go declaration <code>const bufSize =
503 1024</code>, assembly code can refer to the value of this constant
504 as <code>const_bufSize</code>.
505 </p>
506
507 <p>
508 Field offsets are of the form <code><i>type</i>_<i>field</i></code>.
509 Struct sizes are of the form <code><i>type</i>__size</code>.
510 For example, consider the following Go definition:
511 </p>
512
513 <pre>
514 type reader struct {
515 buf [bufSize]byte
516 r int
517 }
518 </pre>
519
520 <p>
521 Assembly can refer to the size of this struct
522 as <code>reader__size</code> and the offsets of the two fields
523 as <code>reader_buf</code> and <code>reader_r</code>.
524 Hence, if register <code>R1</code> contains a pointer to
525 a <code>reader</code>, assembly can reference the <code>r</code> field
526 as <code>reader_r(R1)</code>.
527 </p>
528
529 <p>
530 If any of these <code>#define</code> names are ambiguous (for example,
531 a struct with a <code>_size</code> field), <code>#include
532 "go_asm.h"</code> will fail with a "redefinition of macro" error.
533 </p>
534
535 <h3 id="runtime">Runtime Coordination</h3>
536
537 <p>
538 For garbage collection to run correctly, the runtime must know the
539 location of pointers in all global data and in most stack frames.
540 The Go compiler emits this information when compiling Go source files,
541 but assembly programs must define it explicitly.
542 </p>
543
544 <p>
545 A data symbol marked with the <code>NOPTR</code> flag (see above)
546 is treated as containing no pointers to runtime-allocated data.
547 A data symbol with the <code>RODATA</code> flag
548 is allocated in read-only memory and is therefore treated
549 as implicitly marked <code>NOPTR</code>.
550 A data symbol with a total size smaller than a pointer
551 is also treated as implicitly marked <code>NOPTR</code>.
552 It is not possible to define a symbol containing pointers in an assembly source file;
553 such a symbol must be defined in a Go source file instead.
554 Assembly source can still refer to the symbol by name
555 even without <code>DATA</code> and <code>GLOBL</code> directives.
556 A good general rule of thumb is to define all non-<code>RODATA</code>
557 symbols in Go instead of in assembly.
558 </p>
559
560 <p>
561 Each function also needs annotations giving the location of
562 live pointers in its arguments, results, and local stack frame.
563 For an assembly function with no pointer results and
564 either no local stack frame or no function calls,
565 the only requirement is to define a Go prototype for the function
566 in a Go source file in the same package. The name of the assembly
567 function must not contain the package name component (for example,
568 function <code>Syscall</code> in package <code>syscall</code> should
569 use the name <code>·Syscall</code> instead of the equivalent name
570 <code>syscall·Syscall</code> in its <code>TEXT</code> directive).
571 For more complex situations, explicit annotation is needed.
572 These annotations use pseudo-instructions defined in the standard
573 <code>#include</code> file <code>funcdata.h</code>.
574 </p>
575
576 <p>
577 If a function has no arguments and no results,
578 the pointer information can be omitted.
579 This is indicated by an argument size annotation of <code>$<i>n</i>-0</code>
580 on the <code>TEXT</code> instruction.
581 Otherwise, pointer information must be provided by
582 a Go prototype for the function in a Go source file,
583 even for assembly functions not called directly from Go.
584 (The prototype will also let <code>go</code> <code>vet</code> check the argument references.)
585 At the start of the function, the arguments are assumed
586 to be initialized but the results are assumed uninitialized.
587 If the results will hold live pointers during a call instruction,
588 the function should start by zeroing the results and then
589 executing the pseudo-instruction <code>GO_RESULTS_INITIALIZED</code>.
590 This instruction records that the results are now initialized
591 and should be scanned during stack movement and garbage collection.
592 It is typically easier to arrange that assembly functions do not
593 return pointers or do not contain call instructions;
594 no assembly functions in the standard library use
595 <code>GO_RESULTS_INITIALIZED</code>.
596 </p>
597
598 <p>
599 If a function has no local stack frame,
600 the pointer information can be omitted.
601 This is indicated by a local frame size annotation of <code>$0-<i>n</i></code>
602 on the <code>TEXT</code> instruction.
603 The pointer information can also be omitted if the
604 function contains no call instructions.
605 Otherwise, the local stack frame must not contain pointers,
606 and the assembly must confirm this fact by executing the
607 pseudo-instruction <code>NO_LOCAL_POINTERS</code>.
608 Because stack resizing is implemented by moving the stack,
609 the stack pointer may change during any function call:
610 even pointers to stack data must not be kept in local variables.
611 </p>
612
613 <p>
614 Assembly functions should always be given Go prototypes,
615 both to provide pointer information for the arguments and results
616 and to let <code>go</code> <code>vet</code> check that
617 the offsets being used to access them are correct.
618 </p>
619
620 <h2 id="architectures">Architecture-specific details</h2>
621
622 <p>
623 It is impractical to list all the instructions and other details for each machine.
624 To see what instructions are defined for a given machine, say ARM,
625 look in the source for the <code>obj</code> support library for
626 that architecture, located in the directory <code>src/cmd/internal/obj/arm</code>.
627 In that directory is a file <code>a.out.go</code>; it contains
628 a long list of constants starting with <code>A</code>, like this:
629 </p>
630
631 <pre>
632 const (
633 AAND = obj.ABaseARM + obj.A_ARCHSPECIFIC + iota
634 AEOR
635 ASUB
636 ARSB
637 AADD
638 ...
639 </pre>
640
641 <p>
642 This is the list of instructions and their spellings as known to the assembler and linker for that architecture.
643 Each instruction begins with an initial capital <code>A</code> in this list, so <code>AAND</code>
644 represents the bitwise and instruction,
645 <code>AND</code> (without the leading <code>A</code>),
646 and is written in assembly source as <code>AND</code>.
647 The enumeration is mostly in alphabetical order.
648 (The architecture-independent <code>AXXX</code>, defined in the
649 <code>cmd/internal/obj</code> package,
650 represents an invalid instruction).
651 The sequence of the <code>A</code> names has nothing to do with the actual
652 encoding of the machine instructions.
653 The <code>cmd/internal/obj</code> package takes care of that detail.
654 </p>
655
656 <p>
657 The instructions for both the 386 and AMD64 architectures are listed in
658 <code>cmd/internal/obj/x86/a.out.go</code>.
659 </p>
660
661 <p>
662 The architectures share syntax for common addressing modes such as
663 <code>(R1)</code> (register indirect),
664 <code>4(R1)</code> (register indirect with offset), and
665 <code>$foo(SB)</code> (absolute address).
666 The assembler also supports some (not necessarily all) addressing modes
667 specific to each architecture.
668 The sections below list these.
669 </p>
670
671 <p>
672 One detail evident in the examples from the previous sections is that data in the instructions flows from left to right:
673 <code>MOVQ</code> <code>$0,</code> <code>CX</code> clears <code>CX</code>.
674 This rule applies even on architectures where the conventional notation uses the opposite direction.
675 </p>
676
677 <p>
678 Here follow some descriptions of key Go-specific details for the supported architectures.
679 </p>
680
681 <h3 id="x86">32-bit Intel 386</h3>
682
683 <p>
684 The runtime pointer to the <code>g</code> structure is maintained
685 through the value of an otherwise unused (as far as Go is concerned) register in the MMU.
686 In the runtime package, assembly code can include <code>go_tls.h</code>, which defines
687 an OS- and architecture-dependent macro <code>get_tls</code> for accessing this register.
688 The <code>get_tls</code> macro takes one argument, which is the register to load the
689 <code>g</code> pointer into.
690 </p>
691
692 <p>
693 For example, the sequence to load <code>g</code> and <code>m</code>
694 using <code>CX</code> looks like this:
695 </p>
696
697 <pre>
698 #include "go_tls.h"
699 #include "go_asm.h"
700 ...
701 get_tls(CX)
702 MOVL g(CX), AX // Move g into AX.
703 MOVL g_m(AX), BX // Move g.m into BX.
704 </pre>
705
706 <p>
707 The <code>get_tls</code> macro is also defined on <a href="#amd64">amd64</a>.
708 </p>
709
710 <p>
711 Addressing modes:
712 </p>
713
714 <ul>
715
716 <li>
717 <code>(DI)(BX*2)</code>: The location at address <code>DI</code> plus <code>BX*2</code>.
718 </li>
719
720 <li>
721 <code>64(DI)(BX*2)</code>: The location at address <code>DI</code> plus <code>BX*2</code> plus 64.
722 These modes accept only 1, 2, 4, and 8 as scale factors.
723 </li>
724
725 </ul>
726
727 <p>
728 When using the compiler and assembler's
729 <code>-dynlink</code> or <code>-shared</code> modes,
730 any load or store of a fixed memory location such as a global variable
731 must be assumed to overwrite <code>CX</code>.
732 Therefore, to be safe for use with these modes,
733 assembly sources should typically avoid CX except between memory references.
734 </p>
735
736 <h3 id="amd64">64-bit Intel 386 (a.k.a. amd64)</h3>
737
738 <p>
739 The two architectures behave largely the same at the assembler level.
740 Assembly code to access the <code>m</code> and <code>g</code>
741 pointers on the 64-bit version is the same as on the 32-bit 386,
742 except it uses <code>MOVQ</code> rather than <code>MOVL</code>:
743 </p>
744
745 <pre>
746 get_tls(CX)
747 MOVQ g(CX), AX // Move g into AX.
748 MOVQ g_m(AX), BX // Move g.m into BX.
749 </pre>
750
751 <p>
752 Register <code>BP</code> is callee-save.
753 The assembler automatically inserts <code>BP</code> save/restore when frame size is larger than zero.
754 Using <code>BP</code> as a general purpose register is allowed,
755 however it can interfere with sampling-based profiling.
756 </p>
757
758 <h3 id="arm">ARM</h3>
759
760 <p>
761 The registers <code>R10</code> and <code>R11</code>
762 are reserved by the compiler and linker.
763 </p>
764
765 <p>
766 <code>R10</code> points to the <code>g</code> (goroutine) structure.
767 Within assembler source code, this pointer must be referred to as <code>g</code>;
768 the name <code>R10</code> is not recognized.
769 </p>
770
771 <p>
772 To make it easier for people and compilers to write assembly, the ARM linker
773 allows general addressing forms and pseudo-operations like <code>DIV</code> or <code>MOD</code>
774 that may not be expressible using a single hardware instruction.
775 It implements these forms as multiple instructions, often using the <code>R11</code> register
776 to hold temporary values.
777 Hand-written assembly can use <code>R11</code>, but doing so requires
778 being sure that the linker is not also using it to implement any of the other
779 instructions in the function.
780 </p>
781
782 <p>
783 When defining a <code>TEXT</code>, specifying frame size <code>$-4</code>
784 tells the linker that this is a leaf function that does not need to save <code>LR</code> on entry.
785 </p>
786
787 <p>
788 The name <code>SP</code> always refers to the virtual stack pointer described earlier.
789 For the hardware register, use <code>R13</code>.
790 </p>
791
792 <p>
793 Condition code syntax is to append a period and the one- or two-letter code to the instruction,
794 as in <code>MOVW.EQ</code>.
795 Multiple codes may be appended: <code>MOVM.IA.W</code>.
796 The order of the code modifiers is irrelevant.
797 </p>
798
799 <p>
800 Addressing modes:
801 </p>
802
803 <ul>
804
805 <li>
806 <code>R0-&gt;16</code>
807 <br>
808 <code>R0&gt;&gt;16</code>
809 <br>
810 <code>R0&lt;&lt;16</code>
811 <br>
812 <code>R0@&gt;16</code>:
813 For <code>&lt;&lt;</code>, left shift <code>R0</code> by 16 bits.
814 The other codes are <code>-&gt;</code> (arithmetic right shift),
815 <code>&gt;&gt;</code> (logical right shift), and
816 <code>@&gt;</code> (rotate right).
817 </li>
818
819 <li>
820 <code>R0-&gt;R1</code>
821 <br>
822 <code>R0&gt;&gt;R1</code>
823 <br>
824 <code>R0&lt;&lt;R1</code>
825 <br>
826 <code>R0@&gt;R1</code>:
827 For <code>&lt;&lt;</code>, left shift <code>R0</code> by the count in <code>R1</code>.
828 The other codes are <code>-&gt;</code> (arithmetic right shift),
829 <code>&gt;&gt;</code> (logical right shift), and
830 <code>@&gt;</code> (rotate right).
831
832 </li>
833
834 <li>
835 <code>[R0,g,R12-R15]</code>: For multi-register instructions, the set comprising
836 <code>R0</code>, <code>g</code>, and <code>R12</code> through <code>R15</code> inclusive.
837 </li>
838
839 <li>
840 <code>(R5, R6)</code>: Destination register pair.
841 </li>
842
843 </ul>
844
845 <h3 id="arm64">ARM64</h3>
846
847 <p>
848 <code>R18</code> is the "platform register", reserved on the Apple platform.
849 To prevent accidental misuse, the register is named <code>R18_PLATFORM</code>.
850 <code>R27</code> and <code>R28</code> are reserved by the compiler and linker.
851 <code>R29</code> is the frame pointer.
852 <code>R30</code> is the link register.
853 </p>
854
855 <p>
856 Instruction modifiers are appended to the instruction following a period.
857 The only modifiers are <code>P</code> (postincrement) and <code>W</code>
858 (preincrement):
859 <code>MOVW.P</code>, <code>MOVW.W</code>
860 </p>
861
862 <p>
863 Addressing modes:
864 </p>
865
866 <ul>
867
868 <li>
869 <code>R0-&gt;16</code>
870 <br>
871 <code>R0&gt;&gt;16</code>
872 <br>
873 <code>R0&lt;&lt;16</code>
874 <br>
875 <code>R0@&gt;16</code>:
876 These are the same as on the 32-bit ARM.
877 </li>
878
879 <li>
880 <code>$(8&lt;&lt;12)</code>:
881 Left shift the immediate value <code>8</code> by <code>12</code> bits.
882 </li>
883
884 <li>
885 <code>8(R0)</code>:
886 Add the value of <code>R0</code> and <code>8</code>.
887 </li>
888
889 <li>
890 <code>(R2)(R0)</code>:
891 The location at <code>R0</code> plus <code>R2</code>.
892 </li>
893
894 <li>
895 <code>R0.UXTB</code>
896 <br>
897 <code>R0.UXTB&lt;&lt;imm</code>:
898 <code>UXTB</code>: extract an 8-bit value from the low-order bits of <code>R0</code> and zero-extend it to the size of <code>R0</code>.
899 <code>R0.UXTB&lt;&lt;imm</code>: left shift the result of <code>R0.UXTB</code> by <code>imm</code> bits.
900 The <code>imm</code> value can be 0, 1, 2, 3, or 4.
901 The other extensions include <code>UXTH</code> (16-bit), <code>UXTW</code> (32-bit), and <code>UXTX</code> (64-bit).
902 </li>
903
904 <li>
905 <code>R0.SXTB</code>
906 <br>
907 <code>R0.SXTB&lt;&lt;imm</code>:
908 <code>SXTB</code>: extract an 8-bit value from the low-order bits of <code>R0</code> and sign-extend it to the size of <code>R0</code>.
909 <code>R0.SXTB&lt;&lt;imm</code>: left shift the result of <code>R0.SXTB</code> by <code>imm</code> bits.
910 The <code>imm</code> value can be 0, 1, 2, 3, or 4.
911 The other extensions include <code>SXTH</code> (16-bit), <code>SXTW</code> (32-bit), and <code>SXTX</code> (64-bit).
912 </li>
913
914 <li>
915 <code>(R5, R6)</code>: Register pair for <code>LDAXP</code>/<code>LDP</code>/<code>LDXP</code>/<code>STLXP</code>/<code>STP</code>/<code>STP</code>.
916 </li>
917
918 </ul>
919
920 <p>
921 Reference: <a href="/pkg/cmd/internal/obj/arm64">Go ARM64 Assembly Instructions Reference Manual</a>
922 </p>
923
924 <h3 id="ppc64">PPC64</h3>
925
926 <p>
927 This assembler is used by GOARCH values ppc64 and ppc64le.
928 </p>
929
930 <p>
931 Reference: <a href="/pkg/cmd/internal/obj/ppc64">Go PPC64 Assembly Instructions Reference Manual</a>
932 </p>
933
934 <h3 id="s390x">IBM z/Architecture, a.k.a. s390x</h3>
935
936 <p>
937 The registers <code>R10</code> and <code>R11</code> are reserved.
938 The assembler uses them to hold temporary values when assembling some instructions.
939 </p>
940
941 <p>
942 <code>R13</code> points to the <code>g</code> (goroutine) structure.
943 This register must be referred to as <code>g</code>; the name <code>R13</code> is not recognized.
944 </p>
945
946 <p>
947 <code>R15</code> points to the stack frame and should typically only be accessed using the
948 virtual registers <code>SP</code> and <code>FP</code>.
949 </p>
950
951 <p>
952 Load- and store-multiple instructions operate on a range of registers.
953 The range of registers is specified by a start register and an end register.
954 For example, <code>LMG</code> <code>(R9),</code> <code>R5,</code> <code>R7</code> would load
955 <code>R5</code>, <code>R6</code> and <code>R7</code> with the 64-bit values at
956 <code>0(R9)</code>, <code>8(R9)</code> and <code>16(R9)</code> respectively.
957 </p>
958
959 <p>
960 Storage-and-storage instructions such as <code>MVC</code> and <code>XC</code> are written
961 with the length as the first argument.
962 For example, <code>XC</code> <code>$8,</code> <code>(R9),</code> <code>(R9)</code> would clear
963 eight bytes at the address specified in <code>R9</code>.
964 </p>
965
966 <p>
967 If a vector instruction takes a length or an index as an argument then it will be the
968 first argument.
969 For example, <code>VLEIF</code> <code>$1,</code> <code>$16,</code> <code>V2</code> will load
970 the value sixteen into index one of <code>V2</code>.
971 Care should be taken when using vector instructions to ensure that they are available at
972 runtime.
973 To use vector instructions a machine must have both the vector facility (bit 129 in the
974 facility list) and kernel support.
975 Without kernel support a vector instruction will have no effect (it will be equivalent
976 to a <code>NOP</code> instruction).
977 </p>
978
979 <p>
980 Addressing modes:
981 </p>
982
983 <ul>
984
985 <li>
986 <code>(R5)(R6*1)</code>: The location at <code>R5</code> plus <code>R6</code>.
987 It is a scaled mode as on the x86, but the only scale allowed is <code>1</code>.
988 </li>
989
990 </ul>
991
992 <h3 id="mips">MIPS, MIPS64</h3>
993
994 <p>
995 General purpose registers are named <code>R0</code> through <code>R31</code>,
996 floating point registers are <code>F0</code> through <code>F31</code>.
997 </p>
998
999 <p>
1000 <code>R30</code> is reserved to point to <code>g</code>.
1001 <code>R23</code> is used as a temporary register.
1002 </p>
1003
1004 <p>
1005 In a <code>TEXT</code> directive, the frame size <code>$-4</code> for MIPS or
1006 <code>$-8</code> for MIPS64 instructs the linker not to save <code>LR</code>.
1007 </p>
1008
1009 <p>
1010 <code>SP</code> refers to the virtual stack pointer.
1011 For the hardware register, use <code>R29</code>.
1012 </p>
1013
1014 <p>
1015 Addressing modes:
1016 </p>
1017
1018 <ul>
1019
1020 <li>
1021 <code>16(R1)</code>: The location at <code>R1</code> plus 16.
1022 </li>
1023
1024 <li>
1025 <code>(R1)</code>: Alias for <code>0(R1)</code>.
1026 </li>
1027
1028 </ul>
1029
1030 <p>
1031 The value of <code>GOMIPS</code> environment variable (<code>hardfloat</code> or
1032 <code>softfloat</code>) is made available to assembly code by predefining either
1033 <code>GOMIPS_hardfloat</code> or <code>GOMIPS_softfloat</code>.
1034 </p>
1035
1036 <p>
1037 The value of <code>GOMIPS64</code> environment variable (<code>hardfloat</code> or
1038 <code>softfloat</code>) is made available to assembly code by predefining either
1039 <code>GOMIPS64_hardfloat</code> or <code>GOMIPS64_softfloat</code>.
1040 </p>
1041
1042 <h3 id="unsupported_opcodes">Unsupported opcodes</h3>
1043
1044 <p>
1045 The assemblers are designed to support the compiler so not all hardware instructions
1046 are defined for all architectures: if the compiler doesn't generate it, it might not be there.
1047 If you need to use a missing instruction, there are two ways to proceed.
1048 One is to update the assembler to support that instruction, which is straightforward
1049 but only worthwhile if it's likely the instruction will be used again.
1050 Instead, for simple one-off cases, it's possible to use the <code>BYTE</code>
1051 and <code>WORD</code> directives
1052 to lay down explicit data into the instruction stream within a <code>TEXT</code>.
1053 Here's how the 386 runtime defines the 64-bit atomic load function.
1054 </p>
1055
1056 <pre>
1057 // uint64 atomicload64(uint64 volatile* addr);
1058 // so actually
1059 // void atomicload64(uint64 *res, uint64 volatile *addr);
1060 TEXT runtime·atomicload64(SB), NOSPLIT, $0-12
1061 MOVL ptr+0(FP), AX
1062 TESTL $7, AX
1063 JZ 2(PC)
1064 MOVL 0, AX // crash with nil ptr deref
1065 LEAL ret_lo+4(FP), BX
1066 // MOVQ (%EAX), %MM0
1067 BYTE $0x0f; BYTE $0x6f; BYTE $0x00
1068 // MOVQ %MM0, 0(%EBX)
1069 BYTE $0x0f; BYTE $0x7f; BYTE $0x03
1070 // EMMS
1071 BYTE $0x0F; BYTE $0x77
1072 RET
1073 </pre>