Debian Codegraph @

gcc/testsuite/ada/acats/tests/ca/ca13a01.a

raw
1 -- CA13A01.A
2 --
3 -- Grant of Unlimited Rights
4 --
5 -- Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,
6 -- F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained
7 -- unlimited rights in the software and documentation contained herein.
8 -- Unlimited rights are defined in DFAR 252.227-7013(a)(19). By making
9 -- this public release, the Government intends to confer upon all
10 -- recipients unlimited rights equal to those held by the Government.
11 -- These rights include rights to use, duplicate, release or disclose the
12 -- released technical data and computer software in whole or in part, in
13 -- any manner and for any purpose whatsoever, and to have or permit others
14 -- to do so.
15 --
16 -- DISCLAIMER
17 --
18 -- ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR
19 -- DISCLOSED ARE AS IS. THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED
20 -- WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE
21 -- SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE
22 -- OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A
23 -- PARTICULAR PURPOSE OF SAID MATERIAL.
24 --*
25 --
26 -- OBJECTIVE:
27 -- Check that subunits declared in non-generic child units of a public
28 -- parent have the same visibility into its parent, its siblings
29 -- (public and private), and packages on which its parent depends
30 -- as is available at the point of their declaration.
31 --
32 -- TEST DESCRIPTION:
33 -- Declare an check system procedure as a subunit in a private child
34 -- package of the basic operation package (FA13A00.A). This procedure
35 -- has visibility into its parent ancestor and its private sibling.
36 --
37 -- Declare an emergency procedure as a subunit in a public child package
38 -- of the basic operation package (FA13A00.A). This procedure has
39 -- visibility into its parent ancestor and its private sibling.
40 --
41 -- Declare an express procedure as a subunit in a public child subprogram
42 -- of the basic operation package (FA13A00.A). This procedure has
43 -- visibility into its parent ancestor and its public sibling.
44 --
45 -- In the main program, "with"s the child package and subprogram. Check
46 -- that subunits perform as expected.
47 --
48 -- TEST FILES:
49 -- The following files comprise this test:
50 --
51 -- FA13A00.A
52 -- CA13A01.A
53 --
54 --
55 -- CHANGE HISTORY:
56 -- 06 Dec 94 SAIC ACVC 2.0
57 --
58 --!
59
60 -- Private child package of an elevator application. This package
61 -- provides maintenance operations.
62
63 private package FA13A00_1.CA13A01_4 is -- Maintenance operation
64
65 One_Floor : Floor_No := 1; -- Type declared in parent.
66
67 procedure Check_System;
68
69 -- other type definitions and procedure declarations in real application.
70
71 end FA13A00_1.CA13A01_4;
72
73 --==================================================================--
74
75 -- Context clauses required for visibility needed by separate subunit.
76
77 with FA13A00_0; -- Building Manager
78
79 with FA13A00_1.FA13A00_2; -- Floor Calculation (private)
80
81 with FA13A00_1.FA13A00_3; -- Move Elevator
82
83 use FA13A00_0;
84
85 package body FA13A00_1.CA13A01_4 is
86
87 procedure Check_System is separate;
88
89 end FA13A00_1.CA13A01_4;
90
91 --==================================================================--
92
93 separate (FA13A00_1.CA13A01_4)
94
95 -- Subunit Check_System declared in Maintenance Operation.
96
97 procedure Check_System is
98 begin
99 -- See if regular power is on.
100
101 if Power /= V120 then -- Reference package with'ed by
102 TC_Operation := false; -- the subunit parent's body.
103 end if;
104
105 -- Test elevator function.
106
107 FA13A00_1.FA13A00_3.Move_Elevator -- Reference public sibling of
108 (Penthouse, Call_Waiting); -- the subunit parent's body.
109
110 if not Call_Waiting (Penthouse) then -- Reference private part of the
111 TC_Operation := false; -- parent of the subunit package's
112 -- body.
113 end if;
114
115 FA13A00_1.FA13A00_2.Down (One_Floor); -- Reference private sibling of
116 -- the subunit parent's body.
117
118 if Current_Floor /= Floor'pred (Penthouse) then
119 TC_Operation := false; -- Reference type declared in the
120 end if; -- parent of the subunit parent's
121 -- body.
122
123 end Check_System;
124
125 --==================================================================--
126
127 -- Public child package of an elevator application. This package provides
128 -- an emergency operation.
129
130 package FA13A00_1.CA13A01_5 is -- Emergency Operation
131
132 -- Other type definitions in real application.
133
134 procedure Emergency;
135
136 private
137 type Bell_Type is (Inactive, Active);
138
139 end FA13A00_1.CA13A01_5;
140
141 --==================================================================--
142
143 -- Context clauses required for visibility needed by separate subunit.
144
145 with FA13A00_0; -- Building Manager
146
147 with FA13A00_1.FA13A00_3; -- Move Elevator
148
149 with FA13A00_1.CA13A01_4; -- Maintenance Operation (private)
150
151 use FA13A00_0;
152
153 package body FA13A00_1.CA13A01_5 is
154
155 procedure Emergency is separate;
156
157 end FA13A00_1.CA13A01_5;
158
159 --==================================================================--
160
161 separate (FA13A00_1.CA13A01_5)
162
163 -- Subunit Emergency declared in Maintenance Operation.
164
165 procedure Emergency is
166 Bell : Bell_Type; -- Reference type declared in the
167 -- subunit parent's body.
168
169 begin
170 -- Calls maintenance operation.
171
172 FA13A00_1.CA13A01_4.Check_System; -- Reference private sibling of the
173 -- subunit parent 's body.
174
175 -- Clear all calls to the elevator.
176
177 Clear_Calls (Call_Waiting); -- Reference subprogram declared
178 -- in the parent of the subunit
179 -- parent's body.
180 for I in Floor loop
181 if Call_Waiting (I) then -- Reference private part of the
182 TC_Operation := false; -- parent of the subunit parent's
183 end if; -- body.
184 end loop;
185
186 -- Move elevator to the basement.
187
188 FA13A00_1.FA13A00_3.Move_Elevator -- Reference public sibling of the
189 (Basement, Call_Waiting); -- subunit parent's body.
190
191 if Current_Floor /= Basement then -- Reference type declared in the
192 TC_Operation := false; -- parent of the subunit parent's
193 end if; -- body.
194
195 -- Shut off power.
196
197 Power := Off; -- Reference package with'ed by
198 -- the subunit parent's body.
199
200 -- Activate bell.
201
202 Bell := Active; -- Reference type declared in the
203 -- subunit parent's body.
204
205 end Emergency;
206
207 --==================================================================--
208
209 -- Public child subprogram of an elevator application. This subprogram
210 -- provides an express operation.
211
212 procedure FA13A00_1.CA13A01_6;
213
214 --==================================================================--
215
216 -- Context clauses required for visibility needed by separate subunit.
217
218 with FA13A00_0; -- Building Manager
219
220 with FA13A00_1.FA13A00_2; -- Floor Calculation (private)
221
222 with FA13A00_1.FA13A00_3; -- Move Elevator
223
224 use FA13A00_0;
225
226 procedure FA13A00_1.CA13A01_6 is -- Express Operation
227
228 -- Other type definitions in real application.
229
230 procedure GoTo_Penthouse is separate;
231
232 begin
233 GoTo_Penthouse;
234
235 end FA13A00_1.CA13A01_6;
236
237 --==================================================================--
238
239 separate (FA13A00_1.CA13A01_6)
240
241 -- Subunit GoTo_Penthouse declared in Express Operation.
242
243 procedure GoTo_Penthouse is
244 begin
245 -- Go faster.
246
247 Power := V240; -- Reference package with'ed by
248 -- the subunit parent's body.
249
250 -- Call elevator.
251
252 Call (Penthouse, Call_Waiting); -- Reference subprogram declared in
253 -- the parent of the subunit
254 -- parent's body.
255
256 if not Call_Waiting (Penthouse) then -- Reference private part of the
257 TC_Operation := false; -- parent of the subunit parent's
258 end if; -- body.
259
260 -- Move elevator to Penthouse.
261
262 FA13A00_1.FA13A00_3.Move_Elevator -- Reference public sibling of the
263 (Penthouse, Call_Waiting); -- subunit parent's body.
264
265 if Current_Floor /= Penthouse then -- Reference type declared in the
266 TC_Operation := false; -- parent of the subunit parent's
267 end if; -- body.
268
269 -- Return slowly
270
271 while Current_Floor /= Floor1 loop -- Reference type, subprogram
272 FA13A00_1.FA13A00_2.Down (1); -- declared in the parent of the
273 -- subunit parent's body.
274 end loop;
275
276 if Current_Floor /= Floor1 then -- Reference type declared in
277 TC_Operation := false; -- the parent of the subunit
278 end if; -- parent's body.
279
280 -- Back to normal.
281
282 Power := V120; -- Reference package with'ed by
283 -- the subunit parent's body.
284
285 end GoTo_Penthouse;
286
287 --==================================================================--
288
289 with FA13A00_1.CA13A01_5; -- Emergency Operation
290 -- implicitly with Basic Elevator
291 -- Operations
292
293 with FA13A00_1.CA13A01_6; -- Express Operation
294
295 with Report;
296
297 procedure CA13A01 is
298
299 begin
300
301 Report.Test ("CA13A01", "Check that subunits declared in non-generic " &
302 "child units of a public parent have the same visibility " &
303 "into its parent, its parent's siblings, and packages on " &
304 "which its parent depends");
305
306 -- Go to Penthouse.
307
308 FA13A00_1.CA13A01_6;
309
310 -- Call emergency operation.
311
312 FA13A00_1.CA13A01_5.Emergency;
313
314 if not FA13A00_1.TC_Operation then
315 Report.Failed ("Incorrect elevator operation");
316 end if;
317
318 Report.Result;
319
320 end CA13A01;