Debian Codegraph @

gcc/testsuite/ada/acats/tests/c9/c940010.a

raw
1 -- C940010.A
2 --
3 -- Grant of Unlimited Rights
4 --
5 -- Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,
6 -- F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained
7 -- unlimited rights in the software and documentation contained herein.
8 -- Unlimited rights are defined in DFAR 252.227-7013(a)(19). By making
9 -- this public release, the Government intends to confer upon all
10 -- recipients unlimited rights equal to those held by the Government.
11 -- These rights include rights to use, duplicate, release or disclose the
12 -- released technical data and computer software in whole or in part, in
13 -- any manner and for any purpose whatsoever, and to have or permit others
14 -- to do so.
15 --
16 -- DISCLAIMER
17 --
18 -- ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR
19 -- DISCLOSED ARE AS IS. THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED
20 -- WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE
21 -- SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE
22 -- OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A
23 -- PARTICULAR PURPOSE OF SAID MATERIAL.
24 --*
25 --
26 -- OBJECTIVE:
27 -- Check that if an exception is raised during the execution of an
28 -- entry body it is propagated back to the caller
29 --
30 -- TEST DESCRIPTION:
31 -- Use a small fragment of code from the simulation of a freeway meter
32 -- used in c940007. Create three individual tasks which will be queued on
33 -- the entry as the barrier is set. Release them one at a time. A
34 -- procedure which is called within the entry has been modified for this
35 -- test to raise a different exception for each pass through. Check that
36 -- all expected exceptions are raised and propagated.
37 --
38 --
39 -- CHANGE HISTORY:
40 -- 06 Dec 94 SAIC ACVC 2.0
41 --
42 --!
43
44
45 with Report;
46 with ImpDef;
47
48 procedure C940010 is
49
50 TC_Failed_1 : Boolean := false;
51
52 begin
53
54 Report.Test ("C940010", "Check that an exception raised in an entry " &
55 "body is propagated back to the caller");
56
57 declare -- encapsulate the test
58
59 TC_Defined_Error : Exception; -- User defined exception
60 TC_Expected_Passage_Total : constant integer := 669;
61 TC_Int : constant integer := 5;
62
63 -- Carrier tasks. One is created for each vehicle arriving at each ramp
64 task type Vehicle_31; -- For Ramp_31
65 type acc_Vehicle_31 is access Vehicle_31;
66
67
68 --================================================================
69 protected Ramp_31 is
70
71 function Meter_in_Use_State return Boolean;
72 procedure Add_Meter_Queue;
73 procedure Subtract_Meter_Queue;
74 entry Wait_at_Meter;
75 procedure Pulse;
76 --
77 procedure TC_Passage (Pass_Point : Integer);
78 function TC_Get_Passage_Total return integer;
79 function TC_Get_Current_Exception return integer;
80
81 private
82
83 Release_One_Vehicle : Boolean := false;
84 Meter_in_Use : Boolean := true; -- TC: set true for this test
85 --
86 TC_Multiplier : integer := 1;
87 TC_Passage_Total : integer := 0;
88 -- Use this to cycle through the required exceptions
89 TC_Current_Exception : integer range 0..3 := 0;
90
91 end Ramp_31;
92 --================================================================
93 protected body Ramp_31 is
94
95
96 -- Trace the paths through the various routines by totaling the
97 -- weighted call parameters
98 procedure TC_Passage (Pass_Point : Integer) is
99 begin
100 TC_Passage_Total := TC_Passage_Total+(Pass_Point*TC_Multiplier);
101 end TC_Passage;
102
103 -- For the final check of the whole test
104 function TC_Get_Passage_Total return integer is
105 begin
106 return TC_Passage_Total;
107 end TC_Get_Passage_Total;
108
109 function TC_Get_Current_Exception return integer is
110 begin
111 return TC_Current_Exception;
112 end TC_Get_Current_Exception;
113
114
115 -----------------
116
117 function Meter_in_Use_State return Boolean is
118 begin
119 return Meter_in_Use;
120 end Meter_in_Use_State;
121
122 -- Simulate the effects of the regular signal pulse
123 procedure Pulse is
124 begin
125 Release_one_Vehicle := true;
126 end Pulse;
127
128 -- Keep count of vehicles currently on meter queue - we can't use
129 -- the 'count because we need the outcall trigger
130 procedure Add_Meter_Queue is
131 begin
132 null; --::: stub
133 end Add_Meter_Queue;
134
135 -- TC: This routine has been modified to raise the required
136 -- exceptions
137 procedure Subtract_Meter_Queue is
138 TC_Pass_Point1 : constant integer := 10;
139 TC_Pass_Point2 : constant integer := 20;
140 TC_Pass_Point3 : constant integer := 30;
141 TC_Pass_Point9 : constant integer := 1000; -- error
142 begin
143 -- Cycle through the required exceptions, one per call
144 TC_Current_Exception := TC_Current_Exception + 1;
145 case TC_Current_Exception is
146 when 1 =>
147 TC_Passage (TC_Pass_Point1); -- note passage through here
148 raise Storage_Error; -- PREDEFINED EXCEPTION
149 when 2 =>
150 TC_Passage (TC_Pass_Point2); -- note passage through here
151 raise TC_Defined_Error; -- USER DEFINED EXCEPTION
152 when 3 =>
153 TC_Passage (TC_Pass_Point3); -- note passage through here
154 -- RUN TIME EXCEPTION (Constraint_Error)
155 -- Add the value 3 to 5 then try to assign it to an object
156 -- whose range is 0..3 - this causes the exception.
157 -- Disguise the values which cause the Constraint_Error
158 -- so that the optimizer will not eliminate this code
159 -- Note: the variable is checked at the end to ensure
160 -- that the actual assignment is attempted. Also note
161 -- the value remains at 3 as the assignment does not
162 -- take place. This is the value that is checked at
163 -- the end of the test.
164 -- Otherwise the optimizer could decide that the result
165 -- of the assignment was not used so why bother to do it?
166 TC_Current_Exception :=
167 Report.Ident_Int (TC_Current_Exception) +
168 Report.Ident_Int (TC_Int);
169 when others =>
170 -- Set flag for Report.Failed which cannot be called from
171 -- within a Protected Object
172 TC_Failed_1 := True;
173 end case;
174
175 TC_Passage ( TC_Pass_Point9 ); -- note passage through here
176 end Subtract_Meter_Queue;
177
178 -- Here each Vehicle task queues itself awaiting release
179 entry Wait_at_Meter when Release_One_Vehicle is
180 -- Example of entry with barriers and persistent signal
181 TC_Pass_Point : constant integer := 2;
182 begin
183 TC_Passage ( TC_Pass_Point ); -- note passage through here
184 Release_One_Vehicle := false; -- Consume the signal
185 -- Decrement number of vehicles on ramp
186 Subtract_Meter_Queue; -- Call procedure from within entry body
187 end Wait_at_Meter;
188
189 end Ramp_31;
190 --================================================================
191
192 -- Carrier task. One is created for each vehicle arriving at Ramp_31
193 task body Vehicle_31 is
194 TC_Pass_Point_1 : constant integer := 100;
195 TC_Pass_Point_2 : constant integer := 200;
196 TC_Pass_Point_3 : constant integer := 300;
197 begin
198 if Ramp_31.Meter_in_Use_State then
199 -- Increment count of number of vehicles on ramp
200 Ramp_31.Add_Meter_Queue; -- Call a protected procedure
201 -- which is also called from within
202 -- enter the meter queue
203 Ramp_31.Wait_at_Meter; -- Call a protected entry
204 Report.Failed ("Exception not propagated back");
205 end if;
206 null; --:::: call to the first in the series of the Ramp_Sensors
207 -- this "passes" the vehicle from one sensor to the next
208 exception
209 when Storage_Error =>
210 Ramp_31.TC_Passage ( TC_Pass_Point_1 ); -- note passage
211 when TC_Defined_Error =>
212 Ramp_31.TC_Passage ( TC_Pass_Point_2 ); -- note passage
213 when Constraint_Error =>
214 Ramp_31.TC_Passage ( TC_Pass_Point_3 ); -- note passage
215 when others =>
216 Report.Failed ("Unexpected exception in Vehicle Task");
217 end Vehicle_31;
218
219 -- Simulate the arrival of a vehicle at the Ramp_Receiver of Ramp_31
220 -- and the generation of an accompanying carrier task
221 procedure New_Arrival_31 is
222 Next_Vehicle_Task_31: acc_Vehicle_31 := new Vehicle_31;
223 TC_Pass_Point : constant integer := 1;
224 begin
225 Ramp_31.TC_Passage ( TC_Pass_Point ); -- Note passage through here
226 null; --::: stub
227 end New_arrival_31;
228
229
230
231 begin -- declare
232
233 -- Test driver. This is ALL test control code
234
235 -- Create three independent tasks which will queue themselves on the
236 -- entry. Each task will get a different exception
237 New_Arrival_31;
238 New_Arrival_31;
239 New_Arrival_31;
240
241 delay ImpDef.Clear_Ready_Queue;
242
243 -- Set the barrier condition of the entry true, releasing one task
244 Ramp_31.Pulse;
245 delay ImpDef.Clear_Ready_Queue;
246
247 Ramp_31.Pulse;
248 delay ImpDef.Clear_Ready_Queue;
249
250 Ramp_31.Pulse;
251 delay ImpDef.Clear_Ready_Queue;
252
253 if (TC_Expected_Passage_Total /= Ramp_31.TC_Get_Passage_Total) or
254 -- Note: We are not really interested in this next check. It is
255 -- here to ensure the earlier statements which raised the
256 -- Constraint_Error are not optimized out
257 (Ramp_31.TC_Get_Current_Exception /= 3) then
258 Report.Failed ("Unexpected paths taken");
259 end if;
260
261 end; -- declare
262
263 if TC_Failed_1 then
264 Report.Failed ("Bad path through Subtract_Meter_Queue");
265 end if;
266
267 Report.Result;
268
269 end C940010;