| 1 |
-- C761001.A |
| 2 |
-- |
| 3 |
-- Grant of Unlimited Rights |
| 4 |
-- |
| 5 |
-- Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687, |
| 6 |
-- F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained |
| 7 |
-- unlimited rights in the software and documentation contained herein. |
| 8 |
-- Unlimited rights are defined in DFAR 252.227-7013(a)(19). By making |
| 9 |
-- this public release, the Government intends to confer upon all |
| 10 |
-- recipients unlimited rights equal to those held by the Government. |
| 11 |
-- These rights include rights to use, duplicate, release or disclose the |
| 12 |
-- released technical data and computer software in whole or in part, in |
| 13 |
-- any manner and for any purpose whatsoever, and to have or permit others |
| 14 |
-- to do so. |
| 15 |
-- |
| 16 |
-- DISCLAIMER |
| 17 |
-- |
| 18 |
-- ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR |
| 19 |
-- DISCLOSED ARE AS IS. THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED |
| 20 |
-- WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE |
| 21 |
-- SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE |
| 22 |
-- OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A |
| 23 |
-- PARTICULAR PURPOSE OF SAID MATERIAL. |
| 24 |
--* |
| 25 |
-- |
| 26 |
-- OBJECTIVE: |
| 27 |
-- Check that controlled objects declared immediately within a library |
| 28 |
-- package are finalized following the completion of the environment |
| 29 |
-- task (and prior to termination of the program). |
| 30 |
-- |
| 31 |
-- TEST DESCRIPTION: |
| 32 |
-- This test derives a type from Ada.Finalization.Controlled, and |
| 33 |
-- declares an object of that type in the body of a library package. |
| 34 |
-- The dispatching procedure Finalize is redefined for the derived |
| 35 |
-- type to perform a check that it has been called only once, and in |
| 36 |
-- turn calls Report.Result. This test may fail by not calling |
| 37 |
-- Report.Result. This test may also fail by calling Report.Result |
| 38 |
-- twice, the first call will report a false pass. |
| 39 |
-- |
| 40 |
-- |
| 41 |
-- CHANGE HISTORY: |
| 42 |
-- 06 Dec 94 SAIC ACVC 2.0 |
| 43 |
-- 13 Nov 95 SAIC Updated for ACVC 2.0.1 |
| 44 |
-- |
| 45 |
--! |
| 46 |
|
| 47 |
with Ada.Finalization; |
| 48 |
package C761001_0 is |
| 49 |
|
| 50 |
type Global is new Ada.Finalization.Controlled with null record; |
| 51 |
procedure Finalize( It: in out Global ); |
| 52 |
|
| 53 |
end C761001_0; |
| 54 |
|
| 55 |
package C761001_1 is |
| 56 |
|
| 57 |
task Library_Task is |
| 58 |
entry Never_Called; |
| 59 |
end Library_Task; |
| 60 |
|
| 61 |
end C761001_1; |
| 62 |
|
| 63 |
with Report; |
| 64 |
with C761001_1; |
| 65 |
package body C761001_0 is |
| 66 |
|
| 67 |
My_Object : Global; |
| 68 |
|
| 69 |
Done : Boolean := False; |
| 70 |
|
| 71 |
procedure Finalize( It: in out Global ) is |
| 72 |
begin |
| 73 |
if not C761001_1.Library_Task'Terminated then |
| 74 |
Report.Failed("Library task not terminated before finalize"); |
| 75 |
end if; |
| 76 |
if Done then -- checking included "just in case" |
| 77 |
Report.Comment("Test FAILED, even if previously reporting passed"); |
| 78 |
Report.Failed("Unwarranted multiple call to finalize"); |
| 79 |
end if; |
| 80 |
Report.Result; |
| 81 |
Done := True; |
| 82 |
end Finalize; |
| 83 |
|
| 84 |
end C761001_0; |
| 85 |
|
| 86 |
with Report; |
| 87 |
package body C761001_1 is |
| 88 |
|
| 89 |
task body Library_Task is |
| 90 |
begin |
| 91 |
if Report.Ident_Int( 1 ) /= 1 then |
| 92 |
Report.Failed( "Baseline failure in Library_Task"); |
| 93 |
end if; |
| 94 |
end Library_Task; |
| 95 |
|
| 96 |
end C761001_1; |
| 97 |
|
| 98 |
with Report; |
| 99 |
with C761001_0; |
| 100 |
|
| 101 |
procedure C761001 is |
| 102 |
|
| 103 |
begin -- Main test procedure. |
| 104 |
|
| 105 |
Report.Test ("C761001", "Check that controlled objects declared " |
| 106 |
& "immediately within a library package are " |
| 107 |
& "finalized following the completion of the " |
| 108 |
& "environment task (and prior to termination " |
| 109 |
& "of the program)"); |
| 110 |
|
| 111 |
-- note that if the test DOES call report twice, the first will report a |
| 112 |
-- false pass, the second call will correctly fail the test. |
| 113 |
|
| 114 |
-- not calling Report.Result; |
| 115 |
-- Result is called as part of the finalization of C761001_0.My_Object. |
| 116 |
|
| 117 |
end C761001; |