Debian Codegraph @

doc/en/menu.html

raw
1 <!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN" "http://www.w3.org/TR/html4/loose.dtd">
2 <html>
3 <head>
4 <title>Galvani manual</title>
5 <meta name="generator" content="Bluefish 2.2.17" >
6 <meta name="author" content="burkard" >
7 <meta name="ROBOTS" content="NOINDEX, NOFOLLOW">
8 <meta http-equiv="content-type" content="text/html; charset=UTF-8">
9 <link href="../galvani.css" rel="stylesheet" type="text/css">
10 </head>
11 <body>
12 <div id="kopf">
13 <h1>Galvani manual</h1>
14 <img src="../image/galvani.svg" width="200" height="120" alt="galvani-icon" style="margin-right: 20px;" align="right">
15 </div>
16
17 <div id="navi">
18 <ul>
19 <li><a href="index.html">Start</a></li>
20 <li class="cur"><span>Menu</span></li>
21 <li><a href="toolbar.html">Toolbar</a></li>
22 <li><a href="options.html">Settings</a></li>
23 <li><a href="mess.html">Performing measurements</a></li>
24 <li><a href="eval.html">Data evaluation</a></li>
25 <li><a href="files.html">Files and folders</a></li>
26 </ul>
27 </div>
28
29
30 <div class="titel">
31 <h2>Menu</h2>
32 </div>
33
34 <p class="item_1">Menu File</p>
35 <p class="item_2"> New</p>
36 <p class="anleitung"style="margin-bottom: 0">
37 Generates a new project.
38 <br> After creating the new project, an entry mask "<a href="./options.html#projekt">Project settings</a>" is opened, where all the items should be filled in.
39 <br><br>
40 </p>
41 <p class="item_2">Open</p>
42 <p class="anleitung"style="margin-bottom: 0">
43 Load a Galvani data file.
44 <br> The default path for Galvani data files is ~/galvani/data/ in the user's home directory.
45 <br> If the file contains unknown function names (perhaps in other languages) they can be mapped on known names.
46 After loading the measurement data, project settings are shown. Title and comment can be edited, all other settings are read-only.
47 Data can then be plotted in a diagram and can be evaluated.
48 <br><br>
49 </p>
50 <p class="item_2">Save</p>
51 <p class="anleitung"style="margin-bottom: 0">
52 Save actual measurement data as text file.
53 <br> The default path for Galvani data files is ~/galvani/data/ in the user's home directory. The default extension is ".dat".
54 <br><br>
55 </p>
56 <p class="item_2">Export</p>
57 <p class="anleitung"style="margin-bottom: 0">
58 Save the actual diagram as image file.
59 <br> The default path for diagram files is ~/galvani/data/ in the user's home directory.
60 <br> The filename extension determines the image type (PNG, SVG, EPS or PDF).
61 <br><br>
62 </p>
63 <p class="item_2">Print</p>
64 <p class="anleitung"style="margin-bottom: 0">
65 In the printing dialog some items can be selected or deselected:
66 <ul class="anleitung">
67 <li>Title of the project</li>
68 <li>Diagram</li>
69 <li>Comment</li>
70 <li>Results of evaluation (peak areas of chromatograms, parameters of linear regression)</li>
71 </ul>
72 </p>
73 <p class="anleitung"style="margin-bottom: 0">
74 The user can choose page orientation and margins.<br>
75 Pressing the button <i>Print</i> shows the standard print dialog, where the common printing system settings can be edited.
76 </p>
77 <p class="anleitung"style="margin-bottom: 0">
78 The document viewer <i>evince</i> must be installed for print preview.
79 <br><br>
80 </p>
81 <p class="item_2">Quit</p>
82 <p class="anleitung"style="margin-bottom: 0">
83 Quits the program.
84 </p><br><br clear="all">
85
86 <p class="item_1">Menu View</p>
87 <p class="item_2"> Display</p>
88 <p class="anleitung"style="margin-bottom: 0">
89 The switch <i>display</i> determines, whether measured data are shown numerically during data acquisition in the right upper part of the window.
90 <br>During evaluation the display shows x- and y-coordinate of the cursor position and is always active.
91 <br><br>
92 </p><br><br clear="all">
93
94 <p class="item_1">Menu Measurement</p>
95 <p class="item_2"> New measurement</p>
96 <p class="anleitung"style="margin-bottom: 0">
97 Begin a new measurement with the actual settings.
98 <br> If the project is not yet configured, the entry mask "<a href="./options.html#projekt">Project settings</a>" is shown. Then a diagram is shown.
99 <br><br>
100 </p>
101 <p class="item_2"> Start measurement</p>
102 <p class="anleitung"style="margin-bottom: 0">
103 Start the measurement procedure. Press return key alternatively.
104 </p><br><br>
105 <p class="item_2"> Start with timer</p>
106 <p class="anleitung"style="margin-bottom: 0">
107 Start a timer (default: 10 seconds) for beginning a new measurement procedure.
108 </p><br><br>
109 <p class="item_2"> Cancel measurement</p>
110 <p class="anleitung"style="margin-bottom: 0">
111 Cancel the measurement procedure and return.
112 </p><br><br>
113 <p class="item_2"> Stop measurement</p>
114 <p class="anleitung"style="margin-bottom: 0">
115 Stop the measurement procedure. Press space key alternatively.
116 <br>Then data evaluation can be processed.
117 </p><br><br>
118 <p class="item_2"> End measurement</p>
119 <p class="anleitung"style="margin-bottom: 0">
120 End the measurement. After deleting the diagram a new measurement can be established. The actual settings are conserved.
121 </p><br><br clear="all">
122
123 <p class="item_1">Menu Data</p>
124 <p class="anleitung"style="margin-bottom: 0">
125 Data transformation and evaluation functions can be used for data evaluation. You can activate data transformation before starting a new measurement.
126 </p>
127 <p class="item_2"> Data Transformation</p>
128 <p class="anleitung"style="margin-bottom: 0">
129 Starts the <a href="./eval.html#transformation">Transformation of data</a> for evaluation.</p>
130 <p class="item_2"> Evaluation Functions</p>
131 <p class="anleitung"style="margin-bottom: 0">
132 Starts the selection of <a href="./eval.html#function">Evaluation functions</a>. <br>
133 You can only use this option when a measurement is completed.
134 </p><br><br clear="all">
135
136 <p class="item_1">Menu Settings</p>
137 <p class="item_2"> Data channel X</p>
138 <p class="anleitung"style="margin-bottom: 0">
139 Select or fill in the parameters for <a href="./options.html#kanal_opt">Channel 1 (X)</a>: Select a device or a type of simulation and the settings for serial communication.
140 </p><br><br>
141 <p class="item_2"> Data channel Y</p>
142 <p class="anleitung"style="margin-bottom: 0">
143 Select or fill in the parameters for <a href="./options.html#kanal_opt">Channel 2 (Y)</a>: Select a device or a type of simulation and the settings for serial communication.
144 </p><br><br>
145 <p class="item_2"> Diagram</p>
146 <p class="anleitung"style="margin-bottom: 0">
147 Select the settings for the <a href="./options.html#grafik_opt">Diagram</a> of measurement data: Colours, point symbols, line style, coordinate system.
148 </p><br><br>
149 <p class="item_2"> Save options</p>
150 <p class="anleitung"style="margin-bottom: 0">
151 Save the actual settings in the Galvani configuration file.
152 </p><br><br>
153 <p class="item_2"> Load options</p>
154 <p class="anleitung"style="margin-bottom: 0">
155 Load all program settings from the Galvani configuration file.
156 </p><br><br>
157 <p class="item_2"> Autoload options</p>
158 <p class="anleitung"style="margin-bottom: 0">
159 This switch determines whether the settings of the program are loaded automatically at program start.
160 </p><br><br>
161 <p class="item_2"> Autosave options</p>
162 <p class="anleitung"style="margin-bottom: 0">
163 This switch determines whether the settings of the program are saved automatically at program end.
164 </p><br><br>
165
166 <p class="item_1">Menu Help</p>