| 1 |
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN" "http://www.w3.org/TR/html4/loose.dtd"> |
| 2 |
<html> |
| 3 |
<head> |
| 4 |
<title>Galvani manual</title> |
| 5 |
<meta name="generator" content="Bluefish 2.2.17" > |
| 6 |
<meta name="author" content="burkard" > |
| 7 |
<meta name="ROBOTS" content="NOINDEX, NOFOLLOW"> |
| 8 |
<meta http-equiv="content-type" content="text/html; charset=UTF-8"> |
| 9 |
<link href="../galvani.css" rel="stylesheet" type="text/css"> |
| 10 |
</head> |
| 11 |
<body> |
| 12 |
<div id="kopf"> |
| 13 |
<h1>Galvani manual</h1> |
| 14 |
<img src="../image/galvani.svg" width="200" height="120" alt="galvani-icon" style="margin-right: 20px;" align="right"> |
| 15 |
</div> |
| 16 |
|
| 17 |
<div id="navi"> |
| 18 |
<ul> |
| 19 |
<li><a href="index.html">Start</a></li> |
| 20 |
<li class="cur"><span>Menu</span></li> |
| 21 |
<li><a href="toolbar.html">Toolbar</a></li> |
| 22 |
<li><a href="options.html">Settings</a></li> |
| 23 |
<li><a href="mess.html">Performing measurements</a></li> |
| 24 |
<li><a href="eval.html">Data evaluation</a></li> |
| 25 |
<li><a href="files.html">Files and folders</a></li> |
| 26 |
</ul> |
| 27 |
</div> |
| 28 |
|
| 29 |
|
| 30 |
<div class="titel"> |
| 31 |
<h2>Menu</h2> |
| 32 |
</div> |
| 33 |
|
| 34 |
<p class="item_1">Menu File</p> |
| 35 |
<p class="item_2"> New</p> |
| 36 |
<p class="anleitung"style="margin-bottom: 0"> |
| 37 |
Generates a new project. |
| 38 |
<br> After creating the new project, an entry mask "<a href="./options.html#projekt">Project settings</a>" is opened, where all the items should be filled in. |
| 39 |
<br><br> |
| 40 |
</p> |
| 41 |
<p class="item_2">Open</p> |
| 42 |
<p class="anleitung"style="margin-bottom: 0"> |
| 43 |
Load a Galvani data file. |
| 44 |
<br> The default path for Galvani data files is ~/galvani/data/ in the user's home directory. |
| 45 |
<br> If the file contains unknown function names (perhaps in other languages) they can be mapped on known names. |
| 46 |
After loading the measurement data, project settings are shown. Title and comment can be edited, all other settings are read-only. |
| 47 |
Data can then be plotted in a diagram and can be evaluated. |
| 48 |
<br><br> |
| 49 |
</p> |
| 50 |
<p class="item_2">Save</p> |
| 51 |
<p class="anleitung"style="margin-bottom: 0"> |
| 52 |
Save actual measurement data as text file. |
| 53 |
<br> The default path for Galvani data files is ~/galvani/data/ in the user's home directory. The default extension is ".dat". |
| 54 |
<br><br> |
| 55 |
</p> |
| 56 |
<p class="item_2">Export</p> |
| 57 |
<p class="anleitung"style="margin-bottom: 0"> |
| 58 |
Save the actual diagram as image file. |
| 59 |
<br> The default path for diagram files is ~/galvani/data/ in the user's home directory. |
| 60 |
<br> The filename extension determines the image type (PNG, SVG, EPS or PDF). |
| 61 |
<br><br> |
| 62 |
</p> |
| 63 |
<p class="item_2">Print</p> |
| 64 |
<p class="anleitung"style="margin-bottom: 0"> |
| 65 |
In the printing dialog some items can be selected or deselected: |
| 66 |
<ul class="anleitung"> |
| 67 |
<li>Title of the project</li> |
| 68 |
<li>Diagram</li> |
| 69 |
<li>Comment</li> |
| 70 |
<li>Results of evaluation (peak areas of chromatograms, parameters of linear regression)</li> |
| 71 |
</ul> |
| 72 |
</p> |
| 73 |
<p class="anleitung"style="margin-bottom: 0"> |
| 74 |
The user can choose page orientation and margins.<br> |
| 75 |
Pressing the button <i>Print</i> shows the standard print dialog, where the common printing system settings can be edited. |
| 76 |
</p> |
| 77 |
<p class="anleitung"style="margin-bottom: 0"> |
| 78 |
The document viewer <i>evince</i> must be installed for print preview. |
| 79 |
<br><br> |
| 80 |
</p> |
| 81 |
<p class="item_2">Quit</p> |
| 82 |
<p class="anleitung"style="margin-bottom: 0"> |
| 83 |
Quits the program. |
| 84 |
</p><br><br clear="all"> |
| 85 |
|
| 86 |
<p class="item_1">Menu View</p> |
| 87 |
<p class="item_2"> Display</p> |
| 88 |
<p class="anleitung"style="margin-bottom: 0"> |
| 89 |
The switch <i>display</i> determines, whether measured data are shown numerically during data acquisition in the right upper part of the window. |
| 90 |
<br>During evaluation the display shows x- and y-coordinate of the cursor position and is always active. |
| 91 |
<br><br> |
| 92 |
</p><br><br clear="all"> |
| 93 |
|
| 94 |
<p class="item_1">Menu Measurement</p> |
| 95 |
<p class="item_2"> New measurement</p> |
| 96 |
<p class="anleitung"style="margin-bottom: 0"> |
| 97 |
Begin a new measurement with the actual settings. |
| 98 |
<br> If the project is not yet configured, the entry mask "<a href="./options.html#projekt">Project settings</a>" is shown. Then a diagram is shown. |
| 99 |
<br><br> |
| 100 |
</p> |
| 101 |
<p class="item_2"> Start measurement</p> |
| 102 |
<p class="anleitung"style="margin-bottom: 0"> |
| 103 |
Start the measurement procedure. Press return key alternatively. |
| 104 |
</p><br><br> |
| 105 |
<p class="item_2"> Start with timer</p> |
| 106 |
<p class="anleitung"style="margin-bottom: 0"> |
| 107 |
Start a timer (default: 10 seconds) for beginning a new measurement procedure. |
| 108 |
</p><br><br> |
| 109 |
<p class="item_2"> Cancel measurement</p> |
| 110 |
<p class="anleitung"style="margin-bottom: 0"> |
| 111 |
Cancel the measurement procedure and return. |
| 112 |
</p><br><br> |
| 113 |
<p class="item_2"> Stop measurement</p> |
| 114 |
<p class="anleitung"style="margin-bottom: 0"> |
| 115 |
Stop the measurement procedure. Press space key alternatively. |
| 116 |
<br>Then data evaluation can be processed. |
| 117 |
</p><br><br> |
| 118 |
<p class="item_2"> End measurement</p> |
| 119 |
<p class="anleitung"style="margin-bottom: 0"> |
| 120 |
End the measurement. After deleting the diagram a new measurement can be established. The actual settings are conserved. |
| 121 |
</p><br><br clear="all"> |
| 122 |
|
| 123 |
<p class="item_1">Menu Data</p> |
| 124 |
<p class="anleitung"style="margin-bottom: 0"> |
| 125 |
Data transformation and evaluation functions can be used for data evaluation. You can activate data transformation before starting a new measurement. |
| 126 |
</p> |
| 127 |
<p class="item_2"> Data Transformation</p> |
| 128 |
<p class="anleitung"style="margin-bottom: 0"> |
| 129 |
Starts the <a href="./eval.html#transformation">Transformation of data</a> for evaluation.</p> |
| 130 |
<p class="item_2"> Evaluation Functions</p> |
| 131 |
<p class="anleitung"style="margin-bottom: 0"> |
| 132 |
Starts the selection of <a href="./eval.html#function">Evaluation functions</a>. <br> |
| 133 |
You can only use this option when a measurement is completed. |
| 134 |
</p><br><br clear="all"> |
| 135 |
|
| 136 |
<p class="item_1">Menu Settings</p> |
| 137 |
<p class="item_2"> Data channel X</p> |
| 138 |
<p class="anleitung"style="margin-bottom: 0"> |
| 139 |
Select or fill in the parameters for <a href="./options.html#kanal_opt">Channel 1 (X)</a>: Select a device or a type of simulation and the settings for serial communication. |
| 140 |
</p><br><br> |
| 141 |
<p class="item_2"> Data channel Y</p> |
| 142 |
<p class="anleitung"style="margin-bottom: 0"> |
| 143 |
Select or fill in the parameters for <a href="./options.html#kanal_opt">Channel 2 (Y)</a>: Select a device or a type of simulation and the settings for serial communication. |
| 144 |
</p><br><br> |
| 145 |
<p class="item_2"> Diagram</p> |
| 146 |
<p class="anleitung"style="margin-bottom: 0"> |
| 147 |
Select the settings for the <a href="./options.html#grafik_opt">Diagram</a> of measurement data: Colours, point symbols, line style, coordinate system. |
| 148 |
</p><br><br> |
| 149 |
<p class="item_2"> Save options</p> |
| 150 |
<p class="anleitung"style="margin-bottom: 0"> |
| 151 |
Save the actual settings in the Galvani configuration file. |
| 152 |
</p><br><br> |
| 153 |
<p class="item_2"> Load options</p> |
| 154 |
<p class="anleitung"style="margin-bottom: 0"> |
| 155 |
Load all program settings from the Galvani configuration file. |
| 156 |
</p><br><br> |
| 157 |
<p class="item_2"> Autoload options</p> |
| 158 |
<p class="anleitung"style="margin-bottom: 0"> |
| 159 |
This switch determines whether the settings of the program are loaded automatically at program start. |
| 160 |
</p><br><br> |
| 161 |
<p class="item_2"> Autosave options</p> |
| 162 |
<p class="anleitung"style="margin-bottom: 0"> |
| 163 |
This switch determines whether the settings of the program are saved automatically at program end. |
| 164 |
</p><br><br> |
| 165 |
|
| 166 |
<p class="item_1">Menu Help</p> |
| 167 |
<p class="anleitung"style="margin-bottom: 0"> |
| 168 |
Access to this manual and general informations for Galvani. |
| 169 |
</p><br><br clear="all"> |
| 170 |
|
| 171 |
</body> |
| 172 |
</html> |