| 1 |
Changes in reSID version 0.16 |
| 2 |
----------------------------- |
| 3 |
|
| 4 |
An off-by-one error in the emulation of the ADSR delay bug has been |
| 5 |
fixed in the fast version of the envelope clocking. |
| 6 |
|
| 7 |
An initialization bug in the Filter class which caused floating point |
| 8 |
exceptions on some platforms has been fixed. |
| 9 |
|
| 10 |
Missing fields have been added to SID::State for correct snapshots. |
| 11 |
|
| 12 |
By building shifted FIR tables with samples according to the sampling |
| 13 |
frequency, the resampling code dramatically reduces the computational |
| 14 |
effort in the filter convolutions, without any loss of accuracy. The |
| 15 |
filter convolutions are now also vectorizable on current hardware. The |
| 16 |
implementation builds on ideas by Laurent Ganier. |
| 17 |
|
| 18 |
The resampling code has been split into two functions, one using |
| 19 |
interpolation and a small set of shifted filter tables, and one using |
| 20 |
direct lookup and a large set of shifted filter tables. The accuracy |
| 21 |
is the same, the difference is that the direct lookup runs has the |
| 22 |
potential of running at almost twice the speed (depending on cache |
| 23 |
size and memory bandwidth) using approximately 16MB more memory. It is |
| 24 |
now possible to run high quality resampling in real time on quite |
| 25 |
modest hardware, provided that a vectorizing compiler is used. |
| 26 |
|
| 27 |
|
| 28 |
Changes in reSID version 0.15 |
| 29 |
----------------------------- |
| 30 |
|
| 31 |
An error in the emulation of the ADSR delay bug has been fixed. When |
| 32 |
emulation of the ADSR delay bug was introduced in reSID 0.2, the delay |
| 33 |
was one cycle too long. One cycle was subtracted from the delay in |
| 34 |
reSID 0.4, however unfortunately one rate counter period was added as |
| 35 |
well, thus increasing the error. At the time there was no method to |
| 36 |
fully synchronize the CPU with envelope 3, so the measurements relied |
| 37 |
on averaging. Because of pipelining in the envelope logic the effects |
| 38 |
of a write are delayed, and this caused the test code to miss the |
| 39 |
target by exactly one rate counter period on a real SID. The current |
| 40 |
test code does achieve full synchronization with envelope 3, so this |
| 41 |
time the delay should be 100% correct. There are still side effects |
| 42 |
caused by pipelining which are not implemented in reSID, however these |
| 43 |
effects are not controllable without full synchronization with the |
| 44 |
envelope, something which is hard to achieve with envelope 3, and |
| 45 |
impossible with envelope 1 and 2. |
| 46 |
|
| 47 |
The envelope state (ADSR) has been added to the SID state, and the |
| 48 |
volume setting is now restored from the SID state. |
| 49 |
|
| 50 |
Filter scaling and clipping has been added to avoid sample overflows |
| 51 |
in the resampling filter. |
| 52 |
|
| 53 |
|
| 54 |
Changes in reSID version 0.14 |
| 55 |
----------------------------- |
| 56 |
|
| 57 |
The SID external audio input is now emulated. This can be used e.g. to |
| 58 |
simulate the hack of connecting a resistor from EXT IN to GND to boost |
| 59 |
the sample volume on the MOS8580. Calling sid.input(-32768) makes the |
| 60 |
MOS8580 sound more or less like the MOS6581 with respect to samples. |
| 61 |
The interface could also be used to mix in an external audio signal, |
| 62 |
but note that to do this correctly you should really resample the |
| 63 |
audio signal to 1MHz first. |
| 64 |
|
| 65 |
The filter settings are now updated immediately when the chip model is |
| 66 |
changed. Earlier the filter cutoff frequency would not change until |
| 67 |
the FC registers were updated. |
| 68 |
|
| 69 |
A one cycle error in the fast version of the envelope clocking has |
| 70 |
been fixed. This bug was introduced in reSID 0.13 and could affect the |
| 71 |
ADSR delay emulation. |
| 72 |
|
| 73 |
The exponential counter period is now only loaded at the envelope |
| 74 |
counter values 255, 93, 54, 26, 14, 6, 0. The period can be different |
| 75 |
for the same envelope counter value, depending on whether the envelope |
| 76 |
has been rising (attack -> release) or sinking (decay/release). |
| 77 |
|
| 78 |
A bug in the fast version of the noise register shift routine has been |
| 79 |
corrected. This bug caused too low noise frequency in some cases. |
| 80 |
|
| 81 |
The filter cutoff frequency is limited to 16kHz to keep the filter stable. |
| 82 |
|
| 83 |
|
| 84 |
Changes in reSID version 0.13 |
| 85 |
----------------------------- |
| 86 |
|
| 87 |
The internal DC levels of the MOS6581 have been double checked and |
| 88 |
corrected. The reason for the asymmetric scaling of the voice output |
| 89 |
has been found; there is a DC offset from the waveform D/A converter |
| 90 |
in addition to the DC offset from the envelope multiplying D/A |
| 91 |
converter. No selected waveform (N=P=S=T=0) yields minimum wave output |
| 92 |
level again. |
| 93 |
|
| 94 |
A bug in the fast version of the envelope clocking has been corrected. |
| 95 |
This bug could incorrectly invoke the ADSR delay emulation. |
| 96 |
|
| 97 |
|
| 98 |
Changes in reSID version 0.12 |
| 99 |
----------------------------- |
| 100 |
|
| 101 |
A bug causing incorrect sample spacing in the new SAMPLE_FAST sample |
| 102 |
calculation has been corrected. |
| 103 |
|
| 104 |
Audio clipping has been added to guard against sample overflows. |
| 105 |
|
| 106 |
To support multi-channel sampling, sample interleaving has been added |
| 107 |
to the clock() interface. |
| 108 |
|
| 109 |
To support synchronization with an external timer, an interface for |
| 110 |
sample rate adjustment has been added. |
| 111 |
|
| 112 |
The internal DC levels have been corrected. No selected waveform |
| 113 |
(N=P=S=T=0) yields maximum wave output level. Furthermore, each voice |
| 114 |
in the MOS6581 independently contributes to the DC level in the mixer, |
| 115 |
and the mixer itself has a small DC offset as well. The MOS8580 has no |
| 116 |
DC offsets. |
| 117 |
|
| 118 |
The spline interpolation routine has been generalized to accept |
| 119 |
repeated points to introduce points of non-differentiability and |
| 120 |
discontinuity. |
| 121 |
|
| 122 |
A separate mapping from the FC registers to filter cutoff frequency |
| 123 |
has been included for the MOS8580, and the mapping for the MOS6581 has |
| 124 |
been refined. |
| 125 |
|
| 126 |
|
| 127 |
Changes in reSID version 0.11 |
| 128 |
----------------------------- |
| 129 |
|
| 130 |
A new clock() interface has been added. This function generates audio |
| 131 |
samples into a buffer, greatly simplifying the task of writing driver |
| 132 |
code for reSID. It also facilitates more advanced audio sample |
| 133 |
generation, as described below. |
| 134 |
|
| 135 |
Three clocking methods are available: clocking at output sample |
| 136 |
frequency, clocking at cycle frequency with linear sample |
| 137 |
interpolation, and clocking at cycle frequency with audio resampling. |
| 138 |
|
| 139 |
Clocking at output sample frequency is fast, and yields acceptable |
| 140 |
sound quality, except for the SID combined waveforms, which have a |
| 141 |
very high frequency content. |
| 142 |
|
| 143 |
Clocking at cycle frequency with linear sample interpolation is |
| 144 |
approximately five to ten times slower at 44.1kHz sampling frequency, |
| 145 |
but the sound quality is improved because of the linear sample |
| 146 |
interpolation, and because some sampling noise is removed by the SID |
| 147 |
external filter, which attenuates signals above 16kHz. |
| 148 |
|
| 149 |
Finally, clocking at cycle frequency with audio resampling has a work |
| 150 |
rate which is independent of the sampling frequency; it is rather |
| 151 |
inversely proportional to the percentage of the bandwidth allocated |
| 152 |
to the filter transition band. This implies that e.g. with the |
| 153 |
transition band starting at ~ 20kHz, it is faster to generate 48kHz |
| 154 |
than 44.1kHz samples. |
| 155 |
|
| 156 |
Audio resampling is the theoretically correct method for sample |
| 157 |
generation, and delivers SID sound quality previously unheard of. This |
| 158 |
should make connoisseurs nod in appreciation, and for some time to |
| 159 |
come it could possibly also make people tear their hair over having to |
| 160 |
buy state of the art hardware to handle the obscene workload in real |
| 161 |
time. By trading off passband bandwidth for speed, real time |
| 162 |
processing is possible on current hardware. A 60% passband bandwidth |
| 163 |
is within the reach of reasonably fast machines, while maximum sound |
| 164 |
quality at 90% passband bandwidth, requiring four times the processing |
| 165 |
power, is not. Yet. |
| 166 |
|
| 167 |
|
| 168 |
Changes in reSID version 0.10 |
| 169 |
----------------------------- |
| 170 |
|
| 171 |
Libtool is now used to build the library. |
| 172 |
|
| 173 |
To keep the filters stable it is necessary to clock them at above |
| 174 |
sample rate. The chip clocking code has been modified to only |
| 175 |
"overclock" the filters, not the whole chip. This yields a |
| 176 |
considerable speedup without noticeably lowering sound quality. Note |
| 177 |
that this is aimed at slow hardware, if possible the 1 cycle clock |
| 178 |
interface should be used to eliminate sampling noise. |
| 179 |
|
| 180 |
|
| 181 |
Changes in reSID version 0.9 |
| 182 |
---------------------------- |
| 183 |
|
| 184 |
The sum of the filter outputs is no longer weighted. |
| 185 |
|
| 186 |
|
| 187 |
Changes in reSID version 0.8 |
| 188 |
---------------------------- |
| 189 |
|
| 190 |
voice3off has no effect if voice 3 is routed through the filter. |
| 191 |
|
| 192 |
|
| 193 |
Changes in reSID version 0.7 |
| 194 |
---------------------------- |
| 195 |
|
| 196 |
The audio output filter in the C64, external to the SID chip, has been |
| 197 |
modeled. |
| 198 |
|
| 199 |
The mapping function between the FC register and filter cutoff frequency can |
| 200 |
now be specified with spline interpolation points. This facilitates |
| 201 |
interactive modification of the mapping function by graphical presentation of |
| 202 |
the interpolation curve. The implementation of this novel spline design is |
| 203 |
fast and general purpose, and should be well suited for use in other projects |
| 204 |
as well. |
| 205 |
|
| 206 |
Filtered output has been inverted compared to unfiltered output. |
| 207 |
|
| 208 |
Aging of the bus value obtained when reading write only registers has been |
| 209 |
partly implemented. |
| 210 |
|
| 211 |
To facilitate offline storage the complete state of SID can be read and |
| 212 |
written. |
| 213 |
|
| 214 |
|
| 215 |
Changes in reSID version 0.6 |
| 216 |
---------------------------- |
| 217 |
|
| 218 |
A special case in synchronization has been implemented. |
| 219 |
|
| 220 |
The Autoconf script is cleaned up to allow compilation in a separate directory. |
| 221 |
|
| 222 |
|
| 223 |
Changes in reSID version 0.5 |
| 224 |
---------------------------- |
| 225 |
|
| 226 |
Emulation of MOS8580 combined waveforms. |
| 227 |
|
| 228 |
Version string resid_version_string provided for e.g. Autoconf tests. |
| 229 |
The string has C linkage. |
| 230 |
|
| 231 |
|
| 232 |
Changes in reSID version 0.4 |
| 233 |
---------------------------- |
| 234 |
|
| 235 |
The implementation of the ADSR delay bug has been refined and should now be |
| 236 |
cycle exact. |
| 237 |
|
| 238 |
The patch for VICE has been removed since VICE 0.15 will include reSID support. |
| 239 |
|
| 240 |
|
| 241 |
Changes in reSID version 0.3 |
| 242 |
---------------------------- |
| 243 |
|
| 244 |
The reSID library has changed name from libmos6581.a to libresid.a |
| 245 |
|
| 246 |
The pulse+sawtooth combined waveform has been corrected. |
| 247 |
|
| 248 |
Pulse+test bit samples are implemented. |
| 249 |
|
| 250 |
The envelope rate periods have finally been exactly determined. |
| 251 |
|
| 252 |
A new SID bug, the ADSR boundary bug, has been discovered and implemented. |
| 253 |
This bug makes it possible to step from envelope level 0x00 to 0xff or from |
| 254 |
0xff to 0x00 in one step. |
| 255 |
|
| 256 |
One-cycle optimized overloads of the clock() functions have been implemented |
| 257 |
to facilitate sampling at 1MHz. |
| 258 |
|
| 259 |
The code has been further optimized for speed. |
| 260 |
|
| 261 |
|
| 262 |
Changes in reSID version 0.2 |
| 263 |
---------------------------- |
| 264 |
|
| 265 |
The implementation of the Envelope Generator has been rewritten to handle |
| 266 |
the infamous ADSR delay bug. All known envelope related bugs have been |
| 267 |
corrected. |
| 268 |
|
| 269 |
The maximum filter resonance is lowered to keep the filter stable. |
| 270 |
|
| 271 |
The reSID API has been simplified. Reading write only registers is allowed. |