| 1 |
<HTML> |
| 2 |
<HEAD> |
| 3 |
<TITLE>Tricks and tips (Appendix 8)</TITLE> |
| 4 |
</HEAD> |
| 5 |
<BODY BACKGROUND="/back_fbb.jpg"> |
| 6 |
<P> |
| 7 |
<IMG SRC="/fbb.gif" WIDTH="32" HEIGHT="32"> |
| 8 |
<H1 ALIGN=Center> |
| 9 |
Tricks and tips<SMALL>.</SMALL> |
| 10 |
</H1> |
| 11 |
<P ALIGN=Center> |
| 12 |
(Appendix 8) |
| 13 |
<P> |
| 14 |
<PRE> |
| 15 |
This rubric is yours, more than mine. I'll try to insert there all tricks |
| 16 |
you will tell me. |
| 17 |
|
| 18 |
|
| 19 |
<FONT COLOR="#ff0000">Only for DosFBB:</FONT> |
| 20 |
<B>Using DesqView (c).</B> |
| 21 |
------------------- |
| 22 |
There is no particular problem when using DesqView. The minimum window size |
| 23 |
is 500 KB. You MUST use communication drivers, like ESS, COMBIOS or MBBIOS, |
| 24 |
as the software does not dispose of the whole process time. |
| 25 |
|
| 26 |
|
| 27 |
<B>Communication errors displaying.</B> |
| 28 |
------------------------------- |
| 29 |
An error counter can be displayed |
| 30 |
<FONT COLOR="#ff0000">in WinFBB:</FONT> after the word "Resync" on the screen |
| 31 |
<FONT COLOR="#ff0000">in DosFBB:</FONT> just right of the date, on the first line of the screen. |
| 32 |
If you are using TNC2 with WA8DED software, these errors can be minor, but |
| 33 |
with PK232, error recovery is more difficult, and the system may reboot. |
| 34 |
|
| 35 |
With a correct operation of your system, this counter will not appear, or |
| 36 |
exceptionally. If errors are displayed, they can result from : |
| 37 |
|
| 38 |
- Using DOS 4.0 or 5.0 : The keyboard driver of these versions is very slow. |
| 39 |
You must use the ESS driver for RS232 (or COMBIOS). |
| 40 |
|
| 41 |
- A too hight baudrate, or RS232 defective cables. The baudrate can be |
| 42 |
selected down to 4800 Bds. It is not a good idea to go down 4800 Bds, as the |
| 43 |
performance of the software should be lower. |
| 44 |
|
| 45 |
- Change the LM324 fitting out some TNC RS232 line drivers by a TL074 or |
| 46 |
TL084. |
| 47 |
|
| 48 |
- HF detection in the TNC. Errors and resynchronizations will appear when |
| 49 |
the transmitter is running. There is no real cure, you must investigate. |
| 50 |
|
| 51 |
You can also use communication drivers like ESS, COMBIOS or MBBIOS if you |
| 52 |
are not still using them. |
| 53 |
|
| 54 |
|
| 55 |
<B>Repeat the last message number.</B> |
| 56 |
-------------------------------- |
| 57 |
The last message number displayed, read, killed, etc... can be utilized |
| 58 |
again with the # (pound) character. This short-cut allows as for an example |
| 59 |
to read a message after a list or to suppress it just after its reading. |
| 60 |
|
| 61 |
Example : |
| 62 |
|
| 63 |
F6FBB BBS > R 12351 |
| 64 |
The message is displayed ... |
| 65 |
F6FBB BBS > K # |
| 66 |
Message #12351 killed. |
| 67 |
F6FBB BBS > |
| 68 |
|
| 69 |
|
| 70 |
<B>Problems with BPQ running as a Node !</B> (OZ1CBQ) |
| 71 |
------------------------------------- |
| 72 |
|
| 73 |
If you are using BPQ running as a node together with FBB you may have problems |
| 74 |
if your node ar linked to other nodesystems as TheNet, TheNetNode, X-net, |
| 75 |
RMNC, FlexNet, etc. |
| 76 |
|
| 77 |
BPQ seems to have a compatibility problem with these nodesystems causing some |
| 78 |
hangups during incoming connects via the nodesystem. |
| 79 |
The problem starts with lowering the available buffers and at last the |
| 80 |
system is hanging until a reboot has been done. |
| 81 |
Only cure for the time being is to run BPQ as a SWITCH only without nodeupdate |
| 82 |
(NODE=0 in BPQCFG.TXT) only allowing level_2 traffic. |
| 83 |
|
| 84 |
This brings another problem: |
| 85 |
When FBB runs together with BPQ running as a level_2 switch, it is only |
| 86 |
possible to have outgoing forward on two channels at the time. |
| 87 |
One channel using the callsign and one channel using the alias as first call |
| 88 |
in the forwardfile. |
| 89 |
|
| 90 |
Example 1.st outgoing forward channel: |
| 91 |
|
| 92 |
C C SWITCH |
| 93 |
C C 1 OZ7BOX-2 ; Callsign of the BPQ-switch |
| 94 |
C C .... ; Other connects |
| 95 |
|
| 96 |
Example 2.nd outgoing forward channel: |
| 97 |
|
| 98 |
C C SWITCH |
| 99 |
C C 1 ESBOX ; Alias_name of the BPQ-switch |
| 100 |
C C .... ; Other connects |
| 101 |
|
| 102 |
|
| 103 |
<B>PMS forwarding:</B> |
| 104 |
<B></B>--------------- |
| 105 |
|
| 106 |
In INIT.SRV there is a flag 128 in the FBB-type-forward section. If this flag |
| 107 |
is set, only PMS-users that have been declared with the F-flag in the EU-command |
| 108 |
(Edit User) will be able to up/download messages to/from the BBS. The same |
| 109 |
users should also have the U flag set (in EU-command) to enable them to send |
| 110 |
unproto resync requests to the BBS. |
| 111 |
|
| 112 |
|
| 113 |
<B>Display looks wrong (Only WinFBB):</B> |
| 114 |
---------------------------------- |
| 115 |
|
| 116 |
If you get a wrong display of the windows of WinFBB, halt the software, |
| 117 |
delete windows\winfbb.ini and rerun the software. |
| 118 |
|
| 119 |
|
| 120 |
|
| 121 |
|
| 122 |
|
| 123 |
<A HREF="doc.htm"><IMG SRC="/contents.gif" WIDTH="108" HEIGHT="28"></A> |
| 124 |
|
| 125 |
<A HREF="/"><IMG SRC="../button_home.gif" WIDTH="90" HEIGHT="29"></A> |
| 126 |
|
| 127 |
<FONT COLOR="#800000">This page was last updated <!--#config timefmt="%d-%b-%y"--><!--#echo var="LAST_MODIFIED"--></FONT> |
| 128 |
|
| 129 |
</PRE> |
| 130 |
</BODY></HTML> |