Debian Codegraph @

stdred/optopus/proc/holesopto.prg

raw
1 ! @(#)holesopto.prg 19.1 (ES0-DMD) 02/25/03 14:27:38
2 !++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
3 !.IDENTIFICATION: OPTOP.PRG
4 !.PURPOSE: Start OPTOP program in MIDAS environment
5 !.USE: @@ optop [inp_tab] [out_tab] [HH,MM,SS.sss] [+/-DD,AM,AS.sss] [AC_Flag]
6 ! [P_Flag] [Old_eq,New_eq]
7 !.AUTHOR: Alessandra Gemmo Padova Department of Astronomy
8 !.VERSION: 910228 AG Creation
9 ! 910525 AG Modified for OPTOPUS context
10 ! 920721 Modified by Roland den Hartog, Sterrewacht Leiden,
11 ! to allow automatic input of the plate-center
12 !------------------------------------------------------------------------------
13 DEFINE/PARAM P1 opto1.tbl T "Enter input table [Default=opto1.tbl]: "
14 DEFINE/PARAM P2 opto2.tbl T "Enter output table [Default=opto2.tbl]: "
15 DEFINE/PARAM P3 {PLATECEN(1)},{PLATECEN(2)},{PLATECEN(3)} N "RA (hrs,min,sec):"
16 DEFINE/PARAM P4 {PLATECEN(4)},{PLATECEN(5)},{PLATECEN(6)} N "DEC (deg,amin,asec):"
17 DEFINE/PARAM P5 {ACFLAG} C "AC_Flag: "
18 DEFINE/PARAM P6 {PFLAG} C "P_Flag: "
19 DEFINE/PARAM P7 {EQUINOX(1)},{EQUINOX(2)} N "Old and new equinox for center coordinates: "
20 DEFINE/LOCAL INPUTF1/C/1/80 "temp.tbl"
21 DEFINE/LOCAL TABEQUI/D/1/1 0.
22 DEFINE/LOCAL INDX/I/1/1 0
23 !
24 COMPUTE/KEYW INDX = M$INDEX(P1,".tbl")
25 IF INDX .EQ. 0 THEN
26 WRITE/KEYW INPUTFI/C/1/50 'P1'.tbl
27 ELSE
28 WRITE/KEYW INPUTFI/C/1/50 'P1'
29 ENDIF
30 !
31 WRITE/KEYW OUTPUTF {P2}
32 WRITE/KEYW INPUTD/D/1/3 {P3}
33 WRITE/KEYW INPUTD/D/4/3 {P4}
34 WRITE/KEYW INPUTC/C/1/80 {P4}
35 COPY/DK 'INPUTFI' TABEQUI/D/1/1 TABEQUI/D/1/1
36 !
37 ! do some checks
38 !
39 IF {INPUTD(1)} .LT. 0. THEN
40 WRITE/OUT "*** FATAL: Wrong RA-hours value !!"
41 RETURN
42 ENDIF
43 IF {INPUTD(1)} .GT. 24. THEN
44 WRITE/OUT "*** FATAL: Wrong RA-hours value !!"
45 RETURN
46 ENDIF
47 !
48 IF {INPUTD(2)} .LT. 0. THEN
49 WRITE/OUT "*** FATAL: Wrong RA-min value !!"
50 RETURN
51 ENDIF
52 IF {INPUTD(2)} .GT. 60. THEN
53 WRITE/OUT "*** FATAL: Wrong RA-min value !!"
54 RETURN
55 ENDIF
56 !
57 IF {INPUTD(3)} .LT. 0. THEN
58 WRITE/OUT "*** FATAL: Wrong RA-sec value !!"
59 RETURN
60 ENDIF
61 IF {INPUTD(3)} .GT. 60. THEN
62 WRITE/OUT "*** FATAL: Wrong RA-sec value !!"
63 RETURN
64 ENDIF
65 !
66 IF "{P5}" .EQ. "Y" THEN
67 WRITE/KEYW ACFLAG/C/1/1 {P5}
68 ELSEIF "{P5}" .EQ. "N" THEN
69 WRITE/KEYW ACFLAG/C/1/1 {P5}
70 ELSEIF "{P5}" .EQ. "A" THEN
71 WRITE/KEYW ACFLAG/C/1/1 {P5}
72 ELSE
73 WRITE/OUT "*** FATAL: AC flag can only be either Y, N or A!!"
74 RETURN
75 ENDIF
76 !
77 IF "{P6}" .EQ. "Y" THEN
78 WRITE/KEYW PFLAG/C/1/1 {P6}
79 ELSEIF "{P6}" .EQ. "N" THEN
80 WRITE/KEYW PFLAG/C/1/1 {P6}
81 ELSE
82 WRITE/OUT "*** FATAL: P flag can only be either Y or N !!"
83 RETURN
84 ENDIF
85 !
86 WRITE/KEYW INPUTD/D/7/2 {P7}
87 IF {INPUTD(7)} .LT. 1800. THEN
88 WRITE/OUT "*** FATAL: Wrong value of OLD_EQUINOX !!"
89 RETURN
90 ENDIF
91 IF {INPUTD(7)} .GT. 2100. THEN
92 WRITE/OUT "*** FATAL: Wrong value of OLD_EQUINOX !!"
93 RETURN
94 ENDIF
95 IF {INPUTD(8)} .LT. 1800. THEN
96 WRITE/OUT "*** FATAL: Wrong value of NEW_EQUINOX !!"
97 RETURN
98 ENDIF
99 IF {INPUTD(8)} .GT. 2100. THEN
100 WRITE/OUT "*** FATAL: Wrong value of NEW_EQUINOX !!"
101 RETURN
102 ENDIF
103 WRITE/KEYW EQUINOX/D/1/2 {INPUTD(7)},{INPUTD(8)}
104 !
105 ! get plate center, if any, from input table
106 !
107 IF "{ACFLAG(1:1)}" .EQ. "A" THEN
108 SET/OPT CDEC=
109 SET/FORMAT F12.9
110 SELECT/TABLE {P1} :TYPE.EQ."C".OR.:TYPE.EQ."c"
111 STATISTICS/TABLE 'P1' :RA
112 WRITE/KEYW PLATECEN/D/1/3 'OUTPUTR(3)',0.,0.
113 STATISTICS/TABLE {P1} :DEC
114 WRITE/KEYW PLATECEN/D/4/3 'OUTPUTR(3)',0.,0.
115 WRITE/KEYW PFLAG/C/1/1 N
116 ENDIF
117 !
118 ! select rows that are not deleted and do not contain the plate-center
119 !
120 SELECT/TABLE {P1} ALL
121 SELECT/TABLE {P1} :CHECK.NE."d".AND.:CHECK.NE."D"
122 SELECT/TABLE {P1} SELECT.AND.:TYPE.NE."c".AND.:TYPE.NE."C"
123 !
124 ! determination of the center if not the automatic mode was chosen
125 !
126 SET/FORMAT F12.9
127 !
128 IF "{ACFLAG(1:1)}" .EQ. "Y" THEN
129 IF {INPUTD(1)} .EQ. {PLATECEN(1)} THEN
130 STATISTICS/TABLE {P1} :RA
131 WRITE/KEYW PLATECEN/D/1/3 {OUTPUTR(3)},0.,0.
132 IF {TABEQUI(1)} .NE. {EQUINOX(2)} THEN
133 WRITE/KEYW PFLAG/C/1/1 N
134 ENDIF
135 ELSE
136 WRITE/KEYW PLATECEN/D/1/3 {INPUTD(1)},{INPUTD(2)},{INPUTD(3)}
137 ENDIF
138
139 IF {INPUTD(4)} .EQ. {PLATECEN(4)} THEN
140 STATISTICS/TABLE {P1} :DEC
141 WRITE/KEYW PLATECEN/D/4/3 {OUTPUTR(3)},0.,0.
142 IF {TABEQUI(1)} .NE. {EQUINOX(2)} THEN
143 WRITE/KEYW PFLAG/C/1/1 N
144 ENDIF
145 ELSE
146 WRITE/KEYW PLATECHA/C/1/80 {INPUTC(1:80)}
147 ENDIF
148
149 ELSEIF "{ACFLAG(1:1)}" .EQ. "N" THEN
150 IF {INPUTD(1)} .EQ. {PLATECEN(1)} THEN
151 WRITE/OUT "I'm using default or previously calculated center RA..."
152 ELSE
153 WRITE/KEYW PLATECEN/D/1/3 {INPUTD(1)},{INPUTD(2)},{INPUTD(3)}
154 ENDIF
155
156 IF {INPUTD(4)} .EQ. {PLATECEN(4)} THEN
157 WRITE/OUT "I'm using default or previously calculated center DEC..."
158 ELSE
159 WRITE/KEYW PLATECHA/C/1/80 {INPUTC(1:80)}
160 ENDIF
161
162 ELSE
163 WRITE/KEYW ACFLAG/C/1/1 Y
164 ENDIF
165 !
166 RUN STD_EXE:OPTOP
167 !
168 ! disable automatic determination of the center
169 !
170 WRITE/KEYW ACFLAG/C/1/1 N
171 COPY/TT 'P2' :CHECK 'P1' :CHECK
172 COPY/TABLE 'P1' 'INPUTF1'
173 DELETE/TABLE 'P1' NO