| 1 |
# Version 0.15 # |
| 2 |
|
| 3 |
## DataLab Version 0.15.1 (2024-05-03) ## |
| 4 |
|
| 5 |
🛠️ Bug fixes: |
| 6 |
|
| 7 |
* Fixed [Issue #68](https://github.com/DataLab-Platform/DataLab/issues/68) - Slow loading of even simple plots: |
| 8 |
* On macOS, the user experience was degraded when handling even simple plots |
| 9 |
* This was due to the way macOS handles the pop-up windows, e.g. when refreshing the plot view ("Creating plot items" progress bar), hence causing a very annoying flickering effect and a global slowdown of the application |
| 10 |
* This is now fixed by showing the progress bar only after a short delay (1s), that is when it is really needed (i.e. for long operations) |
| 11 |
* Thanks to [@marcel-goldschen-ohm](https://github.com/marcel-goldschen-ohm) for the very thorough feedback and the help in testing the fix |
| 12 |
* Fixed [Issue #69](https://github.com/DataLab-Platform/DataLab/issues/69) - Annotations should be read-only in Signal/Image View |
| 13 |
* Regarding the annotations, DataLab's current behavior is the following: |
| 14 |
* Annotations are created only when showing the signal/image in a separate window (double-click on the object, or "View" > "View in a new window") |
| 15 |
* When displaying the objects in either the "Signal View" or the "Image View", the annotations should be read-only (i.e. not movable, nor resizable or deletable) |
| 16 |
* However, some annotations were still deletable in the "Signal View" and the "Image View": this is now fixed |
| 17 |
* Note that the fact that annotations can't be created in the "Signal View" or the "Image View" is a limitation of the current implementation, and may be improved in future versions |
| 18 |
|
| 19 |
## DataLab Version 0.15.0 (2024-04-11) ## |
| 20 |
|
| 21 |
🎁 New installer for the stand-alone version on Windows: |
| 22 |
|
| 23 |
* The stand-alone version on Windows is now distributed as an MSI installer (instead of an EXE installer) |
| 24 |
* This avoids the false positive detection of the stand-alone version as a potential threat by some antivirus software |
| 25 |
* The program will install files and shortcuts: |
| 26 |
* For current user, if the user has no administrator privileges |
| 27 |
* For all users, if the user has administrator privileges |
| 28 |
* Installation directory may be customized |
| 29 |
* MSI installer allows to integrate DataLab's installation seemlessly in an organization's deployment system |
| 30 |
|
| 31 |
💥 New features and enhancements: |
| 32 |
|
| 33 |
* Added support for large text/CSV files: |
| 34 |
* Files over 1 GB (and with reasonable number of lines) can now be imported as signals or images without crashing the application or even slowing it down |
| 35 |
* The file is read by chunks and, for signals, the data is downsampled to a reasonable number of points for visualization |
| 36 |
* Large files are supported when opening a file (or dragging and dropping a file in the Signal Panel) and when importing a file in the Text Import Wizard |
| 37 |
* Auto downsampling feature: |
| 38 |
* Added "Auto downsampling" feature to signal visualization settings (see "Settings" dialog box) |
| 39 |
* This feature allows to automatically downsample the signal data for visualization when the number of points is too high and would lead to a slow rendering |
| 40 |
* The downsampling factor is automatically computed based on the configured maximum number of points to display |
| 41 |
* This feature is enabled by default and may be disabled in the signal visualization settings |
| 42 |
* CSV format handling: |
| 43 |
* Improved support for CSV files with a header row (column names) |
| 44 |
* Added support for CSV files with empty columns |
| 45 |
* Open/save file error handling: |
| 46 |
* Error messages are now more explicit when opening or saving a file fails |
| 47 |
* Added a link to the folder containing the file in the error message |
| 48 |
* Added "Plugins and I/O formats" page to the Installation and Configuration Viewer (see "Help" menu) |
| 49 |
* Reset DataLab configuration: |
| 50 |
* In some cases, it may be useful to reset the DataLab configuration file to its default values (e.g. when the configuration file is corrupted) |
| 51 |
* Added new `--reset` command line option to remove the configuration folder |
| 52 |
* Added new "Reset DataLab" Start Menu shortcut to the Windows installer |
| 53 |
|
| 54 |
🛠️ Bug fixes: |
| 55 |
|
| 56 |
* Fixed [Issue #64](https://github.com/DataLab-Platform/DataLab/issues/64) - HDF5 browser does not show datasets with 1x1 size: |
| 57 |
* HDF5 datasets with a size of 1x1 were not shown in the HDF5 browser |
| 58 |
* Even if those datasets should not be considered as signals or images, they are now shown in the HDF5 browser (but not checkable, i.e. not importable as signals or images) |