Debian Codegraph @

d52manual.html

raw
1 <!doctype html public"-//w3c//dtd xhtml 1.0 Transitional//en">
2 <html>
3 <head>
4 <title>D52 Disassembler User's Manual</title>
5 </head>
6 <body>
7 <a name="topofdoc"></a>
8 <div align="center">
9 <font size="8" color="#ff0000">
10 <strong><i>D52 Disassembler User's Manual</i></strong><br>
11 </font>
12 <hr>
13 <font size="4" color="#000000">
14 8052 Disassembler for Linux and Windows<br>
15 GNU General Public License Version 3<br>
16 Copyright 2007 by Jeffery L. Post<br>
17 &nbsp;&#106;_&#112;&#111;st &lt;&#65;T&gt; p&#97;c&#98;e&#108;l &lt;D&#79;T&gt; n&#101;t<br>
18 Hosted on <a href="http://www.8052.com/users/disasm">www.8052.com</a>
19 <br><br>
20 Version 3.4.1 - September, 2007
21 </font>
22 <hr>
23 </div>
24
25 This program is free software; you can redistribute it and/or modify
26 it under the terms of the GNU General Public License as published by
27 the Free Software Foundation, either version 3 of the License, or
28 (at your option) any later version.
29 This program is distributed in the hope that it will be useful,
30 but WITHOUT ANY WARRANTY; without even the implied warranty of
31 MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
32 GNU General Public License for more details.
33 You should have received a copy of the GNU General Public License
34 along with this program; if not, write to the Free Software
35 Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA
36 <br><br>
37 The file COPYING contains the full text of the GNU General Public License, Version 3.
38 <br><br>
39 <i><b>NOTE: As Novell and Microsoft are in violation of the GPL, this software
40 may not be distributed by either Novell or Microsoft. The same prohibition applies
41 to any company that enters into an agreement with Microsoft regarding Microsoft's
42 phony patent claims against Linux. In addition, no one who cannot or will not
43 honor ALL the requirements of GPL version 3 may distribute this software.</b></i>
44 <hr>
45
46 <h3>TABLE OF CONTENTS</h3>
47 <ul>
48 <li><a href="#introduction">Introduction</a><br>
49 <li><a href="#disclaimer">Disclaimer</a><br>
50 <li><a href="#starting">Getting Started</a><br>
51 <li><a href="#options">Command Line Options</a><br>
52 <a href="#aoption">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;A option - define ascii macro</a><br>
53 <a href="#boption">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;B option - disassemble binary file</a><br>
54 <a href="#doption">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;D option - put data in comment field</a><br>
55 <a href="#hoption">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;H option - disassemble hex file</a><br>
56 <a href="#ioption">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;I option - add include for 'sfr52.inc' file</a><br>
57 <a href="#koption">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;K option - disassemble for older (DOS) Keil A51</a><br>
58 <a href="#noption">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;N option - output operands in C style format (0xcd instead of 0cdh)</a><br>
59 <a href="#poption">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;P option - put dot '.' in front of pseudo ops (eg: .equ instead of equ) </a><br>
60 <a href="#soption">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;S option - change pseudo op for ascii strings</a><br>
61 <a href="#toption">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;T option - trace and analyze code before disassembly</a><br>
62 <a href="#uoption">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;U option - output labels, mnemonics, etc in upper case</a><br>
63 <a href="#xoption">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;X option - add hex offset to addresses</a><br>
64 <a href="#zoption">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Z option - read cycle count file (d52 only)</a><br>
65 <li><a href="#directives">Control File Directives - define interpretation of disassembly data</a><br>
66 <a href="#adirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;A directive - address data</a><br>
67 <a href="#bdirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;B directive - byte (8 bit) data</a><br>
68 <a href="#cdirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;C directive - code (force disassembly)</a><br>
69 <a href="#ddirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;D directive - data type (label or symbol)</a><br>
70 <a href="#fdirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;F directive - define SFR label</a><br>
71 <a href="#idirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;I directive - ignore data (do not disassemble)</a><br>
72 <a href="#kdirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;K directive - define name for SFR bit</a><br>
73 <a href="#ldirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;L directive - define label</a><br>
74 <a href="#mdirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;M directive - define name for bit addressable memory</a><br>
75 <a href="#ndirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;N directive - suppress label generation for an address</a><br>
76 <a href="#odirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;O directive - add hex offset to addresses</a><br>
77 <a href="#pdirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;P directive - patch inline code</a><br>
78 <a href="#rdirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;R directive - define register name</a><br>
79 <a href="#sdirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;S directive - define symbol</a><br>
80 <a href="#tdirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;T directive - ascii text</a><br>
81 <a href="#wdirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;W directive - word (16 bit) data </a><br>
82 <a href="#xdirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;X directive - define name for specific operand</a><br>
83 <a href="#ydirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Y directive - define name for specific operand but suppress EQU generation</a><br>
84 <a href="#zdirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Z directive - specify code for which to generate cycle counts</a><br>
85 <a href="#commentdirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;# directive - header comment</a><br>
86 <a href="#icommentdirective">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;! directive - inline comment</a><br>
87 <li><a href="#symnote">A Note on Symbols, Labels and Names</a><br>
88 <li><a href="#outfile">Format of Output File</a><br>
89 <li><a href="#summary">Summary</a><br>
90 <li><a href="#regmaps">8052 Register Maps</a><br>
91 <li><a href="#bsfr">8052 Bit Addressable SFRs</a><br>
92 <li><a href="#bmem">8052 Bit Addressable Memory</a><br>
93 </li>
94 </ul>
95 <br><br>
96
97 <a href="#topofdoc">Back to top</a><br>
98
99 <a name="introduction"></a>
100 <h4><em>Introduction</em></h4>
101 <hr>
102
103 The D52 disassembler allows the user to specify memory areas as code,
104 binary data (8 or 16 bit), ascii text, address tables, or data that should
105 be ignored (not disassembled). You may specify such areas in an ascii text
106 file with the same name as the file to be disassembled, but with an extension
107 of <em>ctl</em> (for example: program.ctl controls the disassembly of program.hex or
108 program.bin).
109 <br><br>
110 With the use of a control file, you can, by an iterative process, get a
111 progressively more meaningful disassembly by modifying the control file
112 based on examination of the output of previous runs of the disassembler.
113 You can also specify names for labels and symbols in the control file,
114 resulting in a much more readable source file.
115 <br><br>
116 Labels and symbols may have as many characters as will fit in one line of
117 the control file, but some cross assemblers (and especially cross linkers)
118 will truncate any more than some fixed number of characters. Consult your
119 cross development tool documentation. Labels and symbols are not case sensitive.
120 <br><br>
121 The control file may exist in either the current directory or the
122 directory of the file to be disassembled. If it is in both directories,
123 the control file in the current directory will take precedence. The
124 output file will always be placed in the current directory.
125 <br><br>
126 The
127 <a href="#starting">getting started</a>
128 section of this document gives some minimal information
129 for users who are eager to try out the disassembler. For best
130 use of the disassembler, however, you should read the sections on
131 <a href="#options">command line options</a>
132 and
133 <a href="#directives">control file directives</a>
134 before proceeding.
135 <br><br>
136 Much of the information in this manual also applies to the 8048 and Z80
137 disassemblers. Invoking the disassemblers without any command line
138 parameters will display a list of options.
139 <br><br>
140
141 <a name="disclaimer"><em>Disclaimer</em></a><hr>
142 D52 is a tool for educational use and for recovering source code that has been
143 lost or is unavailable.
144 <em>Disassembling a program may be unethical or illegal under some circumstances.</em>
145 It is your sole responsibility to determine whether use of D52 for a particular
146 purpose is both legal and ethical.
147 <br><br>
148
149 <br><br>
150 <a href="#topofdoc">Back to top</a><br>
151
152 <a name="starting"></a>
153 <h4><em>Getting Started</em></h4>
154 <hr>
155
156 D52 is a command line disassembler. To disassemble a file called 'program.bin'
157 or 'program.hex', type in (at the command line prompt):
158
159 <table cellspacing=5 summary="">
160 <tr><td></td><td></td><td></td><td></td><td>d52 -d program</td></tr>
161 </table>
162
163 A control file with the same name as the file to be disassembled, but with
164 an extension of '.ctl' can be created in which you can specify areas of
165 memory to be ascii text, 8-bit binary data, 16-bit binary data, etc.
166 A control file is not necessary for disassembly, but as will be seen,
167 it will provide for a much more complete disassembly. The
168 <a href="#toption">t option</a>
169 will cause D52 to trace and analyze the code before disassembly, and will
170 create a preliminary control file.
171
172 <br><br>
173 If a file extension is not provided and neither the
174 <a href="#boption">b option</a>
175 nor the
176 <a href="#hoption">h option</a>
177 is specified on the command line, the disassembler will first search for a hex
178 file and, if it is not found, will then search for a bin file. The disassembler
179 can be forced to look for only one or the other by specifying either the
180 <a href="#boption">binary</a>
181 or the
182 <a href="#hoption">hex</a>
183 option on the command line:
184
185 <table cellspacing=5 summary="">
186 <tr><td></td><td></td><td></td><td></td><td>d52 -db program</td>
187 <td></td><td></td><td></td><td></td><td>for the file program.bin, or</td></tr>
188 <tr><td></td><td></td><td></td><td></td><td>d52 -dh program</td>
189 <td></td><td></td><td></td><td></td><td>for the file program.hex</td></tr>
190 </table>
191
192 If a file extension of '.hex' or '.bin' is provided in the filename (ie: d52 test.hex),
193 that is equivalent to using the
194 <a href="#hoption">h option</a>
195 or
196 <a href="#boption">b option</a>.
197 <br><br>
198
199 D52 will produce a file named 'program.d52' containing the disassembly of
200 the 8051/8052 instructions in the original hex or binary file. It is
201 very useful on the first few disassemblies to use the
202 <a href="#doption">d option</a>
203 , which adds a comment field to every line. The comment field contains the
204 hexadecimal address of each instruction, the hex data for each byte in
205 the instruction, and the ascii code for each byte of the instruction.
206 <br>Example:
207
208 <table cellspacing=5 summary="">
209 <tr><td></td><td></td><td></td><td></td><td></td><td>(opcode/operands)</td><td>(address)</td><td>(data)</td><td>(ascii)</td></tr>
210 <tr><td></td><td></td><td></td><td></td><td></td><td>orl a,#42h</td><td>; 0df6</td><td>44 42</td><td>DB</td></tr>
211 </table>
212
213 This makes it easy to spot areas of ascii text or other nonexecutable
214 code, and you can then modify the control file to tell the disassembler
215 that these areas should be treated as some other kind of data on subsequent
216 disassemblies. Please see the section on
217 <a href="#directives">control file directives</a>
218 for specific information.
219 <br><br>
220
221 By examining the output file and then modifying the control file based
222 on the information obtained, you can get a progressively better disassembly
223 of your program. Generally, about half a dozen iterations of the disassembly
224 are enough to produce a very readable source file that can then be modified
225 and reassembled.
226
227 <br><br>
228 <a href="#topofdoc">Back to top</a><br>
229
230 <a name="options"></a>
231 <h4><em>Command Line Options</em></h4>
232 <hr>
233
234 Command line options modify the operation of the disassembler.
235 They may be specified on the command line using either Unix style
236 options:
237
238 <table cellspacing=5 summary="">
239 <tr><td></td><td></td><td></td><td></td><td></td><td>d52 -db filename</td></tr>
240 </table>
241
242 or DOS style options:
243
244 <table cellspacing=5 summary="">
245 <tr><td></td><td></td><td></td><td></td><td></td><td>d52 /d /b filename</td></tr>
246 </table>
247
248 Options may be entered in a freeform fashion (in any order or format)
249 provided that any options preceeding the filename of the program to be
250 disassembled must begin with either a dash (-) or a slash (/). For example:
251
252 <table cellspacing=5 summary="">
253 <tr><td></td><td></td><td></td><td></td><td></td><td>d52 /db filename -x1000</td></tr>
254 <tr><td></td><td></td><td></td><td></td><td></td><td>d52 filename -d b x1000</td></tr>
255 <tr><td></td><td></td><td></td><td></td><td></td><td>d52 -d filename bx1000</td></tr>
256 </table>
257
258 all mean exactly the same thing and will cause the disassembler to
259 behave in exactly the same way. Exceptions are that the
260 <a href="#xoption">X option</a>
261 , if used, must be the last option given, and if both the
262 <a href="#aoption">A option</a> and the
263 <a href="#soption">S option</a>
264 are used, the S option must preceed the A option.
265 <br><br>
266 Note that the file name specified on the command line does <em>not</em>
267 include the .hex or .bin extention.
268 <br><br>
269 Command line options are:
270 <hr>
271
272 <a name="aoption"></a>
273 <h4><em>A Option (ascii macro)</em></h4>
274
275 The A option tells the disassembler to change the db/defb pseudo op to
276 the ascii macro (pseudo op 'ascii' instead of 'db' or 'defb') for areas
277 defined as ascii text. This will cause the disassembler to include a
278 macro definition in the disassembly output file that should expand to
279 'db' for the cross assembler. To use this option, your cross assembler
280 must be able to handle macros, and in particular, D52's macro format.
281 If used in conjunction with the
282 <a href="#soption">S option</a>
283 , the S option must come first on the command line.
284 <br><br>
285 There are some caveats regarding the ascii macro. The intent of
286 this macro is to make ascii text easier to find in the output file.
287 Once you're satisfied with the readability of the output file, you
288 may want to run the disassembler once more without the A option to
289 produce a file compatible with your cross assembler.
290 <br><br>
291 Some cross assemblers treat certain characters within a macro as
292 special meta-characters. The Huntsville Microsystems HMA8051, for
293 example, regards the characters '#', '.' and '\' as special within a
294 macro. If these characters occur in ascii text using the ascii macro
295 of D52, the assembler will do strange and not so wonderful things with
296 them. If this happens, just do not use the A option (by default, it is off).
297 <br><br>
298 A problem that will be common with all cross assemblers is that
299 the disassembler does not currently treat the single quote (')
300 character differently than it does other characters within
301 ascii text. Since the disassembler delineates ascii text (whether using
302 the A option or not) with the single quote character, its presence
303 in ascii text areas will cause problems. The only solution to this is to
304 manually edit the output file of the disassembler or to define the byte
305 of the single quote as a binary byte in the control file (see the
306 <a href="#bdirective"> B control file directive</a>
307 ).
308
309 <a name="boption"></a>
310 <h4><em>B Option (read binary file)</em></h4>
311
312 The B option forces the disassembler to read a binary file
313 (extention '.bin') instead of an Intel hex file (extention .hex).
314 If neither the B option nor the
315 <a href="#hoption">H option</a>
316 are specified, the disassembler will first search for a file with an
317 extention of .hex, and if not found, will then search for a binary
318 file with an extention of .bin.
319
320 <a name="doption"></a>
321 <h4><em>D Option (put data in comment field)</em></h4>
322
323 The D option tells the disassembler to include a comment field
324 in each disassembled line. The comment field will contain the
325 hexadecimal address of each instruction, the hex data for each
326 byte in the instruction, and the ascii code for each byte of the
327 instruction. Example:
328
329 <table cellspacing=5 summary="">
330 <tr><td></td><td></td><td></td><td></td><td></td><td>(opcode/operands)</td>
331 <td>(address)</td><td>(data)</td><td>(ascii)</td></tr>
332 <tr><td></td><td></td><td></td><td></td><td></td><td>orl a,#42h</td>
333 <td>; 0df6</td><td>44 42</td><td>DB</td></tr>
334 </table>
335
336 This makes it easy to spot areas of ascii text or other nonexecutable
337 code, and then modify the control file to tell the disassembler that
338 these areas should be treated as some other kind of data on subsequent
339 disassemblies. Please see the section on
340
341 <a href="#directives">control file directives</a>
342
343 for specific information.
344
345 <a name="hoption"></a>
346 <h4><em>H Option (read hexadecimal file)</em></h4>
347
348 The H option forces the disassembler to read an Intel hex file
349 (extention '.hex') instead of a binary file (extention '.bin').
350 If neither the
351 <a href="#boption">B option</a>
352 nor the H option are specified, the disassembler will first
353 search for a file with an extention of '.hex', and if not found,
354 will then search for a binary file with an extention of '.bin'.
355
356 <a name="ioption"></a>
357 <h4><em>I option (add include for 'sfr52.inc' file)</em></h4>
358
359 The I option adds this line to the .d52 disassembly file:
360
361 <br><br>
362 <pre>
363 include "sfr52.inc"
364 </pre>
365 <br><br>
366
367 The file 'sfr52.inc' includes equates for 8052 special function registers
368 and SFR bits that may be needed by some cross assemblers. The sfr52.inc
369 file <em>should be modified to suite your 8052 cross assembler</em>
370 since the equates required will vary from assembler to assembler.
371 For example, one cross assembler I test with requires the equate for
372 'acc', and yet another cross assembler not only does not require it,
373 but will generate an error if it is present. You may also need to
374 edit the 'include' pseudo-op in the disassembly file if your cross
375 assembler uses some other pseudo-op to include files (or edit the
376 source file 'd52p2.c' and recompile).
377 <br><br>
378 It is best to start out with all the equates in sfr52.inc commented out,
379 find out what undefined label errors your cross assembler generates,
380 then uncomment the required equates in sfr52.inc.
381 <br><br>
382 This option is incompatible with the
383 <a href="#koption">K option</a>.
384
385 <a name="koption"></a>
386 <h4><em>K Option (disassemble for Keil's A51 assembler)</em></h4>
387
388 Tells D52 to generate source code compatible with the older Keil A51 assembler.
389 <br><br>
390 <i><b>NOTE:</b> Newer versions of Keil's A51 assembler (tested with version 7.10)
391 have come into compliance with the rest of the world. <b>Do not</b> use this option
392 with newer versions of A51.</i>
393
394 <a name="noption"></a>
395 <h4><em>N Option (use C type operands)</em></h4>
396
397 Use this option to have the disassembler output hexadecimal operands using C
398 notation, ie: 0xcd instead of the default 0cdh.
399
400 <a name="poption"></a>
401 <h4><em>P Option (add dot in front of pseudo ops)</em></h4>
402
403 Some assemblers require pseudo operations to begin with a dot. Use this option
404 to have the disassembler output ".equ" instead of "equ" and similar for org and
405 other pseudo operations.
406
407 <a name="soption"></a>
408 <h4><em>S Option (set string pseudo op)</em></h4>
409
410 This option tells the disassembler to generate the pseudo ops
411 'defb' and 'defw' instead of 'db' and 'dw' for those cross
412 assemblers that may require this. Most cross assemblers understand
413 'db' and 'dw', so these are the defaults for the disassembler. Use
414 this option for cross assemblers that do not recognize 'db' and
415 'dw'. If used in conjunction with the
416 <a href="#aoption">A option</a>
417 , the S option must preceed the A option on the command line.
418
419 <a name="toption"></a>
420 <h4><em>T Option (trace and analyze code)</em></h4>
421
422 This option tells D52 to trace and analyze the 8052 code before disassembling it.
423 D52 will attempt to determine which parts of the code are actually code, and
424 which parts are ascii text, binary data, pointers, etc. While it does a reasonably
425 good job of analyzing the code on most files, no program can do as good a job as
426 a human programmer. A control file with the same name as the hex or bin file, but
427 with an extension of '.ctl', will be created before the actual disassembly is
428 performed. You can then edit the control file to correct any erroneous directives,
429 or to add new directives.
430
431 <br><br>
432 <em>Warning:</em> Using this option will <em>overwrite</em> any control file
433 that may already exist for the code file being disassembled. It is intended to
434 be used on the <em>first</em> disassembly only.
435
436 <a name="uoption"></a>
437 <h4><em>U Option (upper case output)</em></h4>
438
439 Causes labels, symbols, mnemonics, etc to be output in upper case, for cross
440 assemblers that may require upper case code. Comments, literal data values,
441 strings, and other output are not affected by this option.
442
443 <a name="xoption"></a>
444 <h4><em>X Option (add hexadecimal offset to addresses)</em></h4>
445
446 This option causes the disassembler to add a hexadecimal offset
447 to the address of every location in the code file. This may be
448 useful for disassembling code that was read from the second (or
449 subsequent) rom of a set of roms. For example, suppose that
450 binary data was obtained from a set of 4K byte eproms (call them
451 rom1 and rom2). Then the first file should be disassembled with
452 the command line:
453
454 <table cellspacing=5 summary="">
455 <tr><td></td><td></td><td></td><td></td><td></td><td>d52 -d rom1</td>
456 </table>
457
458 and the second should be disassembled with the X option:
459
460 <table cellspacing=5 summary="">
461 <tr><td></td><td></td><td></td><td></td><td></td><td>d52 -d rom2 x1000</td>
462 </table>
463
464 The two files then can be combined into one and all references
465 within the disassembled code will be to the correct addresses.
466 <br><br>
467 If given on the command line, the X option overrides any <a href="#odirective">
468 O directive</a> in the control file.
469
470 <a name="zoption"></a>
471 <h4><em>Z Option (read cycle count file - d52 only)</em></h4>
472
473 Jan Waclawek has added code to generate cycle counts for all three disassemblers.
474 In addition, d52 can read customized cycle count files for 8052 derivatives.
475 See the <a href="#zdirective">Z directive</a> for more information.
476
477 Please read Jan's documentation in the 'cyclefiles' directory.
478
479 <table cellspacing=5 summary="">
480 <tr><td></td><td></td><td></td><td></td><td></td><td>d52 -zfilename</td>
481 </table>
482
483 Many thanks to Jan for a great job!
484
485 <br><br>
486 <a href="#topofdoc">Back to top</a><br>
487
488 <a name="directives"></a>
489 <h4><em>Control File Directives</em></h4>
490 <hr>
491
492 Control directives tell the disassembler to treat specified areas
493 of the code to be disassembled as something other than executable
494 code. The user specifies control directives by editing (with any
495 text editor) a control file with the same name as the file to be
496 disassembled, but with a file extention of .ctl (eg: program.ctl
497 to control the disassembly of the file program.hex or program.bin).
498 A generic control file called 'generic.ctl' is provided to get the
499 user started. Copy 'generic.ctl' to 'file.ctl' where 'file' is the
500 name of the binary or Intel hex file to be disassembled, and modify
501 as required based on the output of the disassembler. Then run the
502 disassembler again to get a more readable disassembly of the code.
503 <br><br>
504 All directives consist of a character that specifies the type of data,
505 followed by a hexadecimal number specifying the value or range of
506 values of the data. In the case of a
507 <a href="#ldirective">label</a>
508 or
509 <a href="#sdirective">symbol</a>
510 directive, the hexadecimal number is followed by ascii text defining
511 the label or symbol. See individual directives for examples. All
512 directives must be in the first column of the line. Directives may be
513 complete words, but only the first character is significant, ie:
514
515 <table cellspacing=5 summary="">
516 <tr><td></td><td></td><td></td><td></td><td></td><td>Label</td>
517 <td></td><td></td><td></td><td>0</td>
518 <td></td><td></td><td></td><td>reset</td>
519 <td></td><td></td><td></td><td></td><td></td>
520 <td></td><td></td><td></td><td></td><td>and</td></tr>
521 <tr><td></td><td></td><td></td><td></td><td></td><td>looney</td>
522 <td></td><td></td><td></td><td>0</td>
523 <td></td><td></td><td></td><td>reset</td></tr>
524 </table>
525
526 will both generate the label "reset" for address 0. Note that they
527 are not case sensitive.
528 <br><br>
529 Numerical values must be in hexadecimal and may optionally be preceeded by
530 "0x". For example, a hexadecimal number may be entered as "1234" or
531 "0x1234". Either will be interpreted as the number 1234H.
532 <br><br>
533 Everything following a semi-colon (;) is a comment and will be
534 ignored by the disassembler.
535 <br><br>
536 Label and symbol directives differ in that a label refers to an
537 address and a symbol refers to any 8 or 16 bit immediate data.
538 Therefore an opcode such as
539
540 <table cellspacing=5 summary="">
541 <tr><td></td><td></td><td></td><td></td><td></td><td>mov</td>
542 <td></td><td></td><td></td><td></td><td></td><td>r2,#data</td></tr>
543 </table>
544
545 will cause the disassembler to search only the symbol table for a
546 matching value whereas an opcode such as
547
548 <table cellspacing=5 summary="">
549 <tr><td></td><td></td><td></td><td></td><td></td><td>mov</td>
550 <td></td><td></td><td></td><td></td><td></td><td>dptr,#data</td>
551 </tr>
552 </table>
553
554 will cause the disassembler to search the label table first, and
555 if no matching value is found, to then search the symbol table.
556
557 <br><br>
558 Symbols apply only to immediate data. To specify a symbol for an 8052
559 data memory location, use the
560 <a href="#rdirective">R directive</a>
561 , or to force name substitution for an operand at a given address, use the
562 <a href="#xdirective">X directive</a>.
563 <br><br>
564
565 Single values are specified by entering just the value; ranges of
566 values are specified by a start and stop address separated by a dash
567 (-), or by a start address and count separated by a plus (+), ie:
568
569 <table cellspacing=5 summary="">
570 <tr><td></td><td></td><td></td><td></td><td></td><td>t 1000</td>
571 <td></td><td></td><td></td><td></td><td></td><td></td>
572 <td>the data at address 1000H is ascii text.</td></tr>
573 <tr><td></td><td></td><td></td><td></td><td></td><td>t 1000-1010</td>
574 <td></td><td></td><td></td><td></td><td></td><td></td>
575 <td>the data from address 1000H to (and including)
576 address 1010H is ascii text.</td></tr>
577 <tr><td></td><td></td><td></td><td></td><td></td><td>t 1000+6</td>
578 <td></td><td></td><td></td><td></td><td></td><td></td>
579 <td>ascii text starting at 1000H for 6 bytes.</td></tr>
580 </table>
581
582 Directives are processed in the order in which they are read from
583 the control file. Specifying an area as ascii data and then later
584 specifying it as data to be ignored (uninitialized data) will cause
585 that area to not be disassembled at all. Care must be taken in
586 specifying areas in the control file.
587
588
589 <a name="adirective"></a>
590 <h4><em>A Directive (address data)</em></h4>
591
592 Specifies that the address contains a word value corresponding
593 to an address for which a label should be generated. For example,
594 a vector table may be located at address 0x1000 containing four
595 entries. The user can modify the control file by adding the
596 following entry:
597
598 <table cellspacing=5 summary="">
599 <tr><td></td><td></td><td></td><td></td><td></td><td>a 1000-1007</td></tr>
600 </table>
601
602 This will cause the disassembler to generate the following
603 output lines:
604
605 <table cellspacing=5 summary="">
606 <tr><td></td><td></td><td></td><td></td><td></td><td>dw</td>
607 <td></td><td></td><td></td><td></td><td>vec1</td></tr>
608 <tr><td></td><td></td><td></td><td></td><td></td><td>dw</td>
609 <td></td><td></td><td></td><td></td><td>vec2</td></tr>
610 <tr><td></td><td></td><td></td><td></td><td></td><td>dw</td>
611 <td></td><td></td><td></td><td></td><td>vec3</td></tr>
612 <tr><td></td><td></td><td></td><td></td><td></td><td>dw</td>
613 <td></td><td></td><td></td><td></td><td>vec4</td></tr>
614 </table>
615
616 assuming that the control file also contains entries for the
617 values found at those addresses to generate the labels vec1
618 through vec4. The addresses referenced will be flagged so
619 that labels will be generated in the output file at those
620 addresses.
621
622 <a name="bdirective"></a>
623 <h4><em>B Directive (byte binary data)</em></h4>
624
625 Specifies that the data is to be interpreted as 8 bit binary
626 data. For example:
627
628 <table cellspacing=5 summary="">
629 <tr><td></td><td></td><td></td><td></td><td></td><td>b 1000-1007</td></tr>
630 </table>
631
632 tells the disassembler that the data from address 1000H to 1007H
633 should generate the line:
634
635 <table cellspacing=5 summary="">
636 <tr><td></td><td></td><td></td><td></td><td></td><td>db</td>
637 <td></td><td></td><td></td><td></td><td>0,1,2,3,4,5,6,7</td></tr>
638 </table>
639
640 assuming that the data at address 1000H and up is 00H, 01H, etc.
641
642 <a name="cdirective"></a>
643 <h4><em>C Directive (code data)</em></h4>
644
645 Forces the disassembler to interpret the data as executable code.
646 This may be necessary because the disassembler skips over strings
647 of 00H or ffH bytes that occur since they are unlikely to be real
648 code. However, sometimes programmers insert several NOPs for timing
649 purposes.
650
651 <a name="ddirective"></a>
652 <h4><em>D Directive (define data type (label or symbol))</em></h4>
653
654 <table cellspacing=5 summary="">
655 <tr><td></td><td></td><td></td><td></td><td></td><td>d address [0 or label]</td>
656 <td></td><td></td><td></td><td></td><td>search label table only</td></tr>
657 <tr><td></td><td></td><td></td><td></td><td></td><td>d address [1 or symbol]</td>
658 <td></td><td></td><td></td><td></td><td>search symbol table only</td></tr>
659 <tr><td></td><td></td><td></td><td></td><td></td><td>d address [2 or none]</td>
660 <td></td><td></td><td></td><td></td><td>don't search either table</td></tr>
661 </table>
662
663 Forces the disassembler to search only the label or symbol table. This
664 allows you to specify a label and a symbol for the same value. For example:
665
666 <table cellspacing=5 summary="">
667 <tr><td></td><td></td><td></td><td></td><td></td><td>mov dptr,#1234</td>
668 </tr>
669 </table>
670
671 would normally search only the label table assuming that the data refers
672 to a code address. If the data is really a constant with the same value as
673 a label, then
674
675 <table summary="">
676 <tr><td></td><td></td><td></td><td></td><td></td><td></td><td></td><td></td><td></td><td>d 1 address</td></tr>
677 </table>
678
679 will force the disassmbler to look only in the symbol table for the string
680 that represents the value of the data. The address is the address of the
681 opcode, not the code location of the data operand.
682 <br><br>
683 Note that the last parameter can be either a number (0, 1, or 2) or a word
684 (label, symbol, none). If the last parameter is a word, only the first
685 character is checked for L, S, or N, and is not case sensitive.
686
687 <a name="fdirective"></a>
688 <h4><em>F Directive (SFR label definition)</em></h4>
689
690 Causes reference to an SFR (special function register) to
691 generate a label for the specified SFR address. This is useful
692 for naming SFR's for non-standard members of the 8052 family.
693 For example, suppose that some manufacturer designs a new 8052
694 variant and decides to use address efH as a new special function
695 register called 'NEWREG'. Then by adding:
696
697 <table cellspacing=5 summary="">
698 <tr><td></td><td></td><td></td><td></td><td></td><td>f ef newreg</td></tr>
699 </table>
700
701 to the control file, D52 will disassemble the opcodes f5 ef as:
702
703 <table cellspacing=5 summary="">
704 <tr><td></td><td></td><td></td><td></td><td></td><td>mov</td>
705 <td></td><td></td><td></td><td></td><td>newreg,a</td></tr>
706 </table>
707
708 instead of:
709
710 <table cellspacing=5 summary="">
711 <tr><td></td><td></td><td></td><td></td><td></td><td>mov</td>
712 <td></td><td></td><td></td><td></td><td>0efh,a</td></tr>
713 </table>
714
715 SFR label names are limited to fifteen characters.
716
717 <a name="idirective"></a>
718 <h4><em>I Directive (ignore data)</em></h4>
719
720 Tells the disassembler to ignore a range of addresses that may be
721 initialized by the input file. This is useful when the input file
722 is a binary file generated by an eprom programmer that dumps the
723 entire eprom space. The valid data from a 4K eprom might only be,
724 say, 3K in length. By adding
725
726 <table cellspacing=5 summary="">
727 <tr><td></td><td></td><td></td><td></td><td></td><td>i c00-fff</td></tr>
728 </table>
729
730 to the control file, you tell the disassembler to not disassemble
731 the data from address 0c00H to 0fffH.
732
733 <a name="kdirective"></a>
734 <h4><em>K Directive (SFR bit definition)</em></h4>
735
736 As with the
737 <a href="#fdirective">F directive</a>
738 , you can give a name to a new SFR bit. If a new variant of the 8052
739 family adds a new interrupt, for instance, its enable bit in the IE
740 register might be bit 6. By adding:
741
742 <table cellspacing=5 summary="">
743 <tr><td></td><td></td><td></td><td></td><td></td><td>k ae newint</td>
744 <td></td><td></td><td></td><td></td><td></td><td></td><td></td><td>(ae is the address of IE.6)</td></tr>
745 </table>
746
747 you define bit 6 of the interrupt enable register to be 'ie.newint'.
748 Like SFR label names, SFR bit names are limited to fifteen characters.
749
750 <a name="ldirective"></a>
751 <h4><em>L Directive (label definition)</em></h4>
752
753 Defines a label to the disassembler. Labels are generated in the
754 output disassembly file whenever a reference to the address is
755 found and the label exists in the label table. Suppose that
756 address 0000H contains the code 01 43 (ajmp 0043H). Then the entry
757
758 <table cellspacing=5 summary="">
759 <tr><td></td><td></td><td></td><td></td><td></td><td>l 43 start</td></tr>
760 </table>
761
762 in the control file will cause D52 to disassemble this code as:
763
764 <table cellspacing=5 summary="">
765 <tr><td></td><td></td><td></td><td></td><td></td><td>ajmp</td>
766 <td></td><td></td><td></td><td></td><td>start</td></tr>
767 </table>
768
769 rather than:
770
771 <table cellspacing=5 summary="">
772 <tr><td></td><td></td><td></td><td></td><td></td><td>ajmp</td>
773 <td></td><td></td><td></td><td></td><td>X0043</td></tr>
774 </table>
775
776 The code beginning at address 43H will then have the label
777 'start' in the label field rather than the label 'X0043'. See
778 the entry for the
779 <a href="#sdirective">S directive</a>
780 for an explanation of the difference between labels and symbols.
781
782 <a name="mdirective"></a>
783 <h4><em>M Directive (bit addressable memory label)</em></h4>
784
785 Similar to the
786 <a href="#kdirective">K directive</a>
787 , the M directive gives a name to a bit addressable memory location. Example:
788
789 <table cellspacing=5 summary="">
790 <tr><td></td><td></td><td></td><td></td><td></td><td>m 12 bitflag</td>
791 <td></td><td></td><td></td><td></td><td>(12h is the bit address of 22h.2)</td></tr>
792 </table>
793
794 would cause the bytes d2 12 to be disassembled as
795
796 <table cellspacing=5 summary="">
797 <tr><td></td><td></td><td></td><td></td><td></td><td>setb</td>
798 <td></td><td></td><td></td><td></td><td></td><td>bitflag</td></tr>
799 </table>
800
801 instead of
802
803 <table cellspacing=5 summary="">
804 <tr><td></td><td></td><td></td><td></td><td></td><td>setb</td>
805 <td></td><td></td><td></td><td></td><td></td><td>22h.2</td></tr>
806 </table>
807
808 As with the K directive, names are limited to fifteen characters.
809
810 <a name="ndirective"></a>
811 <h4><em>N Directive (suppress address label generation)</em></h4>
812
813 The disassembler will generate labels for addresses that are referenced by code
814 such as
815
816 <table cellspacing=5 summary="">
817 <tr><td></td><td></td><td></td><td></td><td></td><td>mov</td>
818 <td></td><td></td><td></td><td></td><td></td><td>dptr,#6</td></tr>
819 </table>
820
821 If the operand represents a constant rather than an address, you can suppress
822 the automatic generation of a label (X0006) for address 6h by entering
823
824 <table cellspacing=5 summary="">
825 <tr><td></td><td></td><td></td><td></td><td></td><td>n 6</td>
826 </table>
827
828 in the control file. You'd want to make sure that address 6h isn't legitimately
829 addressed by some other code before using this directive.
830
831 <a name="odirective"></a>
832 <h4><em>O Directive (add hexadecimal offset to addresses)</em></h4>
833
834 This directive causes the disassembler to add a hexadecimal offset to the address
835 of every location in the code file. See the <a href="#xoption">X option</a>
836 for details. It will be overridden by any <a href="#xoption">X option</a>
837 specified on the command line. If the <a href="#toption">T option</a> (trace and
838 analyze code) is given on the command line, the O directive has no effect since
839 any existing control file will be rewritten. In this case you must use the command
840 line X option to specify an offset.
841
842 <a name="pdirective"></a>
843 <h4><em>P Directive (patch inline code)</em></h4>
844
845 This directive is of dubious value, but has been added for anyone who might find
846 it useful. The P directive is similar to the
847 <a href="#commentdirective">comment directive</a>
848 except that the user supplied string is patched into the output stream as
849 <i>code</i>, not as a comment. You could, for instance, patch in a macro
850 definition or an include statement. Patching in executable code is not a real
851 good idea.
852
853 <a name="rdirective"></a>
854 <h4><em>R Directive (register definition)</em></h4>
855
856 This directive specifies a name for an 8052 register. Direct
857 accesses to registers will normally be disassembled as:
858
859 <table cellspacing=5 summary="">
860 <tr><td></td><td></td><td></td><td></td><td></td><td>mov</td>
861 <td></td><td></td><td></td><td></td><td></td><td>rb2r5,a</td></tr>
862 </table>
863
864 in the case of register 5 of register bank 2. If the user
865 determines that register 5 of bank 2 is being used as a loop
866 counter, for example, he can give it the name loop by adding:
867
868 <table cellspacing=5 summary="">
869 <tr><td></td><td></td><td></td><td></td><td></td><td>r 15 loop</td></tr>
870 </table>
871
872 to the control file, and the above code will be disassembled as:
873
874 <table cellspacing=5 summary="">
875 <tr><td></td><td></td><td></td><td></td><td></td><td>mov
876 <td></td><td></td><td></td><td></td><td></td><td>loop,a</td></tr>
877 </table>
878
879 The R directive can assign a name to any internal memory location
880 below the SFR address space.
881
882 <a name="sdirective"></a>
883 <h4><em>S Directive (symbol definition)</em></h4>
884
885 Defines a symbol to the disassembler. Symbols are output to the
886 disassembly file whenever the value is encountered in the input
887 file and the symbol exists in the symbol table. The user can
888 specify a symbol for a value by a line such as:
889
890 <table cellspacing=5 summary="">
891 <tr><td></td><td></td><td></td><td></td><td></td><td>s 20 space</td></tr>
892 </table>
893
894 Code which uses this value, such as:
895
896 <table cellspacing=5 summary="">
897 <tr><td></td><td></td><td></td><td></td><td></td><td>mov</td>
898 <td></td><td></td><td></td><td></td><td>a,#20h</td>
899 </tr>
900 </table>
901
902 will then be disassembled as:
903
904 <table cellspacing=5 summary="">
905 <tr><td></td><td></td><td></td><td></td><td></td><td>mov</td>
906 <td></td><td></td><td></td><td></td><td>a,#space</td>
907 </tr>
908 </table>
909
910 Labels and symbols differ in that a label applies to an address,
911 whereas a symbol applies to any 8 or 16 bit immediate data. For
912 code which can only refer to values, such as
913
914 <table cellspacing=5 summary="">
915 <tr><td></td><td></td><td></td><td></td><td></td><td>mov</td>
916 <td></td><td></td><td></td><td></td><td>a,#20h</td>
917 </tr>
918 </table>
919
920 only the symbol table will be searched for a matching value. For
921 code which could refer to either an address or a value, such as:
922
923 <table cellspacing=5 summary="">
924 <tr><td></td><td></td><td></td><td></td><td></td><td>mov</td>
925 <td></td><td></td><td></td><td></td><td>dptr,#1234h</td>
926 </tr>
927 </table>
928
929 the label table will be searched first, and only if no matching
930 value is found will the symbol table then be searched. This search
931 behavior can be modified by use of the
932 <a href="#ddirective">d directive</a> or the
933 <a href="#xdirective">x directive</a>.
934
935 <a name="tdirective"></a>
936 <h4><em>T Directive (text [ascii] data)</em></h4>
937
938 Forces the data in the range specified to be disassembled as
939 text (ascii data). Thus the code: 48 69 20 74 68 65 72 65 at
940 address 1000H will be disassembled as:
941
942 <table cellspacing=5 summary="">
943 <tr><td></td><td></td><td></td><td></td><td></td><td>db</td>
944 <td></td><td></td><td></td><td></td><td></td><td>'Hi there'</td>
945 <td></td><td></td><td></td><td></td><td></td><td>or</td></tr>
946 <tr><td></td><td></td><td></td><td></td><td></td><td>ascii</td>
947 <td></td><td></td><td></td><td></td><td></td><td>'Hi there'</td>
948 <td></td><td></td><td></td><td></td><td></td><td>(command line option A used)</td></tr>
949 </table>
950
951 by putting the line:
952
953 <table cellspacing=5 summary="">
954 <tr><td></td><td></td><td></td><td></td><td></td><td>t 1000-1007</td></tr>
955 </table>
956
957 in the control file. Otherwise it would be interpreted as:
958
959 <table cellspacing=5 summary="">
960 <tr><td></td><td></td><td></td><td></td><td></td><td>orl</td>
961 <td></td><td></td><td></td><td></td><td></td><td>a,r0</td>
962 <td></td><td></td><td></td><td></td><td></td><td>; 1000</td>
963 <td></td><td></td><td>48</td>
964 <td></td><td></td><td>H</td></tr>
965 <tr><td></td><td></td><td></td><td></td><td></td><td>xrl</td>
966 <td></td><td></td><td></td><td></td><td></td><td>a,r1</td>
967 <td></td><td></td><td></td><td></td><td></td><td>; 1001</td>
968 <td></td><td></td><td>69</td>
969 <td></td><td></td><td>i</td></tr>
970 <tr><td></td><td></td><td></td><td></td><td></td><td>jb</td>
971 <td></td><td></td><td></td><td></td><td></td><td>2eh.4,X106d</td>
972 <td></td><td></td><td></td><td></td><td></td><td>; 1002</td>
973 <td></td><td></td><td>20 74 68</td>
974 <td></td><td></td><td>th</td></tr>
975 <tr><td></td><td></td><td></td><td></td><td></td><td>xrl</td>
976 <td></td><td></td><td></td><td></td><td></td><td>a,72h</td>
977 <td></td><td></td><td></td><td></td><td></td><td>; 1005</td>
978 <td></td><td></td><td>65 72</td>
979 <td></td><td></td><td>er</td></tr>
980 <tr><td></td><td></td><td></td><td></td><td></td><td>xrl</td>
981 <td></td><td></td><td></td><td></td><td></td><td>a,t3</td>
982 <td></td><td></td><td></td><td></td><td></td><td>; 1007</td>
983 <td></td><td></td><td>65 ff</td>
984 <td></td><td></td><td>e.</td></tr>
985 </table>
986
987 which is unlikely to be what was intended by the original
988 programmer. Data specified by this directive is not checked
989 to verify that it really is ascii data--be careful.
990
991 <a name="wdirective"></a>
992 <h4><em>W Directive (word binary data)</em></h4>
993
994 Specifies that the data is to be interpreted as 16 bit binary
995 data. For example:
996
997 <table cellspacing=5 summary="">
998 <tr><td></td><td></td><td></td><td></td><td></td><td>w 1000-1007</td></tr>
999 </table>
1000
1001 tells the disassembler that the data from address 1000H to 1007H
1002 should generate the lines:
1003
1004 <table cellspacing=5 summary="">
1005 <tr><td></td><td></td><td></td><td></td><td></td><td>dw</td>
1006 <td></td><td></td><td></td><td></td><td>0</td></tr>
1007 <tr><td></td><td></td><td></td><td></td><td></td><td>dw
1008 <td></td><td></td><td></td><td></td><td>1</td></tr>
1009 <tr><td></td><td></td><td></td><td></td><td></td><td>dw
1010 <td></td><td></td><td></td><td></td><td>2</td></tr>
1011 <tr><td></td><td></td><td></td><td></td><td></td><td>dw
1012 <td></td><td></td><td></td><td></td><td>3</td></tr>
1013 </table>
1014
1015 assuming that the data at address 1000H and up is 00H, 00H,
1016 00H, 01H, 00H, 02H, etc. This differs from the A (address)
1017 directive in that the
1018 <a href="#adirective">A directive</a>
1019 also causes a reference to be made to the indirect address.
1020 In other words, if the data at address 1000H is 1234H, the A
1021 directive will cause a label (X1234) to be put in the output
1022 file at address 1234H, whereas the W directive will not.
1023
1024 <a name="xdirective"></a>
1025 <h4><em>X Directive (specify name for operand data)</em></h4>
1026
1027 Specify a name for an operand at a particular address. This is similar
1028 to the
1029 <a href="#sdirective">S directive</a>
1030 except that it applies only to the given address. For example, if the
1031 <em>symbol</em> 'CR' is defined as 0dh, every instance of 0dh as an operand will
1032 have the symbol 'CR' substituted. It may be, however, that the value
1033 0dh has a different meaning when used as an operand for a particular
1034 instruction. The X directive allows you to modify the interpretation
1035 of an operand at specific operand locations. Why not then use the X
1036 directive exclusively? Because that would force you to place an X
1037 directive in the control file for <em>every</em> instance in which
1038 that value appeared as an operand. The S directive, defined only once
1039 for an operand value, will substitute the symbol text for <em>every</em>
1040 occurrance of that operand value unless overridden by the X directive.
1041 Note that the address defined in the X directive is the address of the
1042 operand, not the address of the instruction. For example:
1043
1044 <table cellspacing=5 summary="">
1045 <tr><td></td><td></td><td></td><td></td><td></td><td>X 102 loopinit</td></tr>
1046 </table>
1047
1048 forces substitution of the text 'loopinit' for the operand located at
1049 address 102h. Therefore an instruction that should be interpreted as
1050
1051 <table cellspacing=5 summary="">
1052 <tr><td></td><td></td><td></td><td></td><td></td><td>mov</td>
1053 <td></td><td></td><td>r0,#loopinit</td></tr>
1054 </table>
1055
1056 will not be disassembled as
1057
1058 <table cellspacing=5 summary="">
1059 <tr><td></td><td></td><td></td><td></td><td></td><td>mov</td>
1060 <td></td><td></td><td>r0,#CR</td></tr>
1061 </table>
1062
1063 if the control file contains the above x directive, and also contains an
1064 <a href="#sdirective">S directive</a>
1065 defining 0dh as 'CR', and the value of the operand for the mov
1066 instruction happens to also be 0dh.
1067
1068 <a name="ydirective"></a>
1069 <h4><em>Y Directive (specify name for operand data but suppress EQU generation)</em></h4>
1070
1071 This is similar to the X directive except that the disassembler will not
1072 generate an EQU statement for the operand value in the output file. This should
1073 be used when you want to specify a name for an operand that is an assembler
1074 pseudo-op such as LOW() or HIGH().
1075
1076 <a name="zdirective"></a>
1077 <h4><em>Z Directive (specify code for which to generate cycle count information)</em></h4>
1078
1079 Specify addresses for which cycle count information will be added in the
1080 disassembly file. Also see the <a href="#zoption">Z option</a>.
1081 <br>
1082 Please read Jan's documentation in the 'cyclefiles' directory.
1083
1084 <a name="commentdirective"></a>
1085 <h4><em># Directive (header comment string)</em></h4>
1086
1087 Defines a comment string to be output prior to disassembly at
1088 the specified address. For example:<br><br>
1089
1090 <!-- This is one time we DO want to use <pre> -->
1091
1092 <pre>
1093 # 95
1094 # 95 Start of initialization
1095 # 95
1096 </pre>
1097 <br><br>
1098 in the ctl file would cause the output<br><br>
1099 <pre>
1100 ;
1101 ; Start of initialization
1102 ;
1103 clr ea ;0095 c2 af B/
1104 </pre>
1105 <br><br>
1106 assuming that the code 'c2 af' was located at address 0x95.
1107 Since ASCII strings consume prodigious amounts of memory, it is
1108 wise to use this directive sparingly. It is, however, useful for
1109 marking blocks of code that have been identified in previous
1110 runs of D52.
1111
1112 <a name="icommentdirective"></a>
1113 <h4><em>! Directive (inline comment string)</em></h4>
1114
1115 Defines a comment string to be output after disassembly at
1116 the specified address. For example:<br><br>
1117
1118 <!-- This is one time we DO want to use <pre> -->
1119
1120 <pre>
1121 ! 95 Start of initialization
1122 </pre>
1123 <br><br>
1124 in the ctl file would cause the output<br><br>
1125 <pre>
1126 clr ea ;0095 c2 af B/ ; Start of initialization
1127 </pre>
1128 <br><br>
1129 for the above example. Note that inline comments are only available for code
1130 and word data, and will do nothing if the data at the specified address is defined
1131 as data other than code or word data (ascii text, for example).
1132
1133 <br><br>
1134 <a href="#topofdoc">Back to top</a><br>
1135
1136 <a name="symnote"></a>
1137 <h4><em>A Note on Symbols, Labels and Names</em></h4>
1138 <hr>
1139 An example will best explain the difference between labels, symbols, operand
1140 names and register names. Labels refer to program code locations, symbols
1141 refer to immediate operands, register names and operand names refer to data
1142 memory locations.
1143 <br><br>
1144
1145 <em>Given the hex or binary file produced from the follow source code:</em>
1146 <br><br>
1147
1148 <table cellspacing=5 summary="">
1149 <tr><td></td><td></td><td></td><td></td><td></td><td>org</td>
1150 <td></td><td></td><td>30h</td></tr>
1151 <tr><td>main</td><td></td><td></td><td></td><td></td><td>mov</td>
1152 <td></td><td></td><td>a,30h</td></tr>
1153 <tr><td></td><td></td><td></td><td></td><td></td><td>mov</td>
1154 <td></td><td></td><td>30h,r0</td></tr>
1155 <tr><td></td><td></td><td></td><td></td><td></td><td>mov</td>
1156 <td></td><td></td><td>r1,#30h</td></tr>
1157 <tr><td></td><td></td><td></td><td></td><td></td><td>sjmp</td>
1158 <td></td><td></td><td>main</td></tr>
1159 <tr><td></td><td></td><td></td><td></td><td></td><td>end</td></tr>
1160 </table>
1161
1162 <br>
1163 <em>and this control file:</em>
1164 <br><br>
1165
1166 <table cellspacing=5 summary="">
1167 <tr><td>l 30</td><td>main</td><td></td><td>; label for code address</td></tr>
1168 <tr><td>x 33</td><td>thirty</td><td></td><td>; name for operand at address 33h</td></tr>
1169 <tr><td>s 30</td><td>alsothirty</td><td></td><td>; symbol for immediate operand</td></tr>
1170 <tr><td>r 30</td><td>counter</td><td></td><td>; name for data memory address (register) at 30h</td></tr>
1171 </table>
1172 <br><br>
1173
1174 <em>D52 will produce the following output:</em>
1175 <br><br>
1176
1177 <table cellspacing=5 summary="">
1178 <tr><td>;</td></tr>
1179 <tr><td></td><td></td><td>org</td><td></td><td></td><td></td><td>30h</td></tr>
1180 <tr><td>;</td></tr>
1181 <tr><td>main:</td><td></td><td>mov</td><td></td><td>a,counter</td><td></td><td>; 0030 e5 30</td><td></td><td>e0</td></tr>
1182 <tr><td></td><td></td><td>mov</td><td></td><td>thirty,r0</td><td></td><td>; 0032 88 30</td><td></td><td>.0</td></tr>
1183 <tr><td></td><td></td><td>mov</td><td></td><td>r1,#alsothirty</td><td></td><td>; 0034 79 30</td><td></td><td>y0</td></tr>
1184 <tr><td></td><td></td><td>sjmp</td><td></td><td>main</td><td></td><td>; 0036 80 f8</td><td></td><td>.x</td></tr>
1185 <tr><td>;</td></tr>
1186 <tr><td>counter</td><td></td><td>equ</td><td></td><td>30h</td></tr>
1187 <tr><td>alsothirty</td><td></td><td>equ</td><td></td><td>30h</td></tr>
1188 <tr><td>thirty</td><td></td><td>equ</td><td></td><td>30h</td></tr>
1189 <tr><td>;</td></tr>
1190 <tr><td></td><td></td><td>end</td></tr>
1191 <tr><td>;</td></tr>
1192 </table>
1193 <br><br>
1194
1195 Note that the label, symbol, register name, and operand name all have
1196 the same value: 30h. But the operand name directive (
1197 <a href="#xdirective">x directive</a>) in
1198 the control file specifies the <em>address</em> of the operand (in
1199 this case 33h), and the other three control file directives refer to
1200 the <em>value</em> of the operand. The x directive allows you to use
1201 a different name for the same value (unlike a symbol), so that, for
1202 example, an operand value of 0dh in one place can be disassembled with
1203 the name 'CR' and in another place as, say, 'loop_init_count'.
1204
1205 <br><br>
1206
1207 <a name="outfile"></a>
1208 <h4><em>Format of Output File</em></h4>
1209 <hr>
1210
1211 The output file for D52 (extention '.d52') contains 8052 instructions
1212 and pseudo ops in a format that should be acceptable to any 8052
1213 cross assembler. When assembled, the source file should produce an Intel
1214 hex file or binary file that is identical to the original. Identical, in
1215 this case, means that the code is the same, not that it necessarily has
1216 the same format. The number of bytes in each line of the hex file may
1217 differ from the original depending on whether the original was produced
1218 by an assembler or was read from an eprom.
1219
1220 Each output line is in the following format:
1221
1222 <table cellspacing=5 summary="">
1223 <tr><td></td><td></td><td></td><td></td><td></td><td>LABEL:</td>
1224 <td></td><td></td><td>OPCODE</td>
1225 <td></td><td></td><td>OPERANDS</td>
1226 <td></td><td></td><td>; COMMENT</td></tr>
1227 </table>
1228
1229 The label field will be generated only if the address of the code
1230 is referenced by some other code (a call, for instance), or if the
1231 user has specified a label for that address in the control file.
1232 The comment field is only generated if the user specifies the D
1233 option on the command line. Comments begin with a semicolon and are
1234 followed by the hexadecimal address of the instruction, the hex
1235 value of the byte(s) for the instruction, and finally by the ascii
1236 representation of the instruction byte(s). For example:
1237
1238 <table cellspacing=5 summary="">
1239 <tr><td></td><td></td><td></td><td></td><td></td><td>X004f:</td>
1240 <td></td><td></td><td></td><td>orl</td>
1241 <td></td><td></td><td></td><td>p3,#0ffh</td>
1242 <td></td><td></td><td></td><td>; 004f</td>
1243 <td></td><td></td><td></td><td>43 b0 ff</td>
1244 <td></td><td></td><td></td><td>C0.</td></tr>
1245 <tr><td></td><td></td><td></td><td></td><td></td><td>label</td>
1246 <td></td><td></td><td></td><td>opcode</td>
1247 <td></td><td></td><td></td><td>operands</td>
1248 <td></td><td></td><td></td><td>comment</td></tr>
1249 </table>
1250
1251 Several things should be noted in this example. The label is 'X'
1252 followed by the address of the instruction in four hex digits.
1253 This type of label is created by the disassembler when some other
1254 code references the address. If the user specifies a label name for
1255 the address in the control file ('what' for example), the generated
1256 code becomes:
1257
1258 <table cellspacing=5 summary="">
1259 <tr><td></td><td></td><td></td><td></td><td></td><td>what:</td>
1260 <td></td><td></td><td></td><td>orl</td>
1261 <td></td><td></td><td></td><td>p3,#0ffh</td>
1262 <td></td><td></td><td></td><td>; 004f</td>
1263 <td></td><td></td><td></td><td>43 b0 ff</td>
1264 <td></td><td></td><td></td><td>C0.</td></tr>
1265 </table>
1266
1267 If the user were to specify the symbol 'ones' for the value 0ffH,
1268 the output would then become:
1269
1270 <table cellspacing=5 summary="">
1271 <tr><td></td><td></td><td></td><td></td><td></td><td>what:</td>
1272 <td></td><td></td><td></td><td>orl</td>
1273 <td></td><td></td><td></td><td>p3,#ones</td>
1274 <td></td><td></td><td></td><td>; 004f</td>
1275 <td></td><td></td><td></td><td>43 b0 ff</td>
1276 <td></td><td></td><td></td><td>C0.</td></tr>
1277 </table>
1278
1279 Also note the ascii representation of the instruction bytes. Bit
1280 7 is forced to zero so that ascii with the high bit set can be
1281 viewed (b0H in the example becomes 30H, which is ascii '0'). Any
1282 code which is not printable ascii (a control code, for example)
1283 is output as a period. This is the case for the byte 0ffH above.
1284 <br><br>
1285 The comment field starts at a different position in the output
1286 line depending on the type of data in the input file. For normal
1287 executable code, the comment field starts in column 32; for hex
1288 data it starts at column 49, and for ascii data it starts in
1289 column 56. For many programs, this makes for a more readable
1290 source file, but if there is a mix of data types in a short range
1291 of addresses, this can lead to some strange looking formatting.
1292 The user may want to correct this with a text editor in the final
1293 disassembly before modification and reassembly.
1294
1295 <br><br>
1296 <a href="#topofdoc">Back to top</a><br>
1297 <br><br>
1298
1299 <a name="summary"></a>
1300 <h4><em>Summary</em></h4>
1301 <hr>
1302
1303 D52 is distributed under the GNU General Public License. See the file COPYING
1304 for details. D52 versions 3.1 and higher are a continuation of the earlier
1305 disassembler named D51.
1306 <br><br>
1307 D52 allows the user to specify how code should be disassembled via a control
1308 file that defines given areas of the code as ascii text, binary data or other
1309 types of non-executable code. By an iterative process of disassembly, control
1310 file modification, and further disassembly, the user can obtain a very readable
1311 source file that can then be modified and re-assembled by a cross assembler.
1312 Several public domain cross assemblers are available.
1313 <br><br>
1314 I've encountered several problems when reassembling the output of D52.
1315 Almost all are due to the cross assembler not recognizing SFRs of some
1316 of the newer or more exotic 8052 variants. The D52 tables include
1317 names for all SFRs that I'm aware of as of May 1995 (there are likely
1318 some that I'm not aware of). Such errors might be corrected just by
1319 defining a symbol for the SFR in the control file (see the
1320 <a href="#fdirective">F directive</a>
1321 ), but this depends on whether your cross assembler will accept it as a
1322 valid operand. If all else fails, replace the offending instruction
1323 with a 'db' pseudo op and put the mnemonic and operand in a comment.
1324 A similar problem is the assembler not being able to handle a bit
1325 addressable SFR address; the only solution I see to this is to use a
1326 'db' pseudo op. All other problems I've seen (not many) have been due
1327 to disassembling data as code; this is easily corrected by modifying
1328 the control file to specify the correct data type.
1329 <br><br>
1330
1331 Many thanks to numerous beta testers who have made invaluable
1332 suggestions for improvement and found more bugs than I care to think about.
1333 Also thanks to all the users who have, over the years, also made significant
1334 contributions to the betterment of D52. Any remaining deficiencies are solely
1335 my fault.
1336
1337 <br><br>
1338
1339 <h4><em>Summary of command line options and control file directives</em></h4>
1340 Command line options:
1341 <br>
1342 <ul>
1343 <li>A - Change db/defb pseudo op to 'ascii' macro for text
1344 <li>B - Force read of binary file (.bin extention)
1345 <li>D - Add address and data info in comment field
1346 <li>H - Force read of Intel hex file (.hex extention)
1347 <li>I - Add statement to include file 'sfr52.inc' in output file
1348 <li>K - Disassemble for older Keil A51 assembler
1349 <li>N - Output C style hexadecimal operands
1350 <li>P - Add a dot '.' to beginning of pseudo operation codes
1351 <li>S - Change db and dw pseudo ops to defb and defw
1352 <li>T - Trace and analyze code before disassembly
1353 <li>U - Output labels, mnemonics, etc in upper case
1354 <li>X - Add hexadecimal offset to all program locations
1355 <li>Z - Read cycle count file (d52 only)
1356 </ul>
1357 Control file directives:
1358 <br>
1359 <ul>
1360 <li>A - Specifies that words in program space are addresses
1361 <li>B - Data is 8 bit binary
1362 <li>C - Program space is executable code
1363 <li>D - Force search of only label table or only symbol table for operand name
1364 <li>F - Specify SFR label
1365 <li>I - Ignore data (uninitialize program space)
1366 <li>K - Specify label for SFR bit
1367 <li>L - Define label
1368 <li>M - Specify label for bit addressable memory
1369 <li>N - Suppress generation of address label
1370 <li>O - Add hexadecimal offset to all program locations
1371 <li>P - Patch inline code
1372 <li>R - Define register name
1373 <li>S - Define symbol
1374 <li>T - Specify ascii text
1375 <li>W - Data is 16 bit binary
1376 <li>X - Specify name for a specific operand
1377 <li>Y - Specify name for a specific operand but do not generate an EQU statement
1378 <li>Z - Specify addresses for which to generate cycle count information
1379 <li># - Define a header comment string
1380 <li>! - Define an inline comment string
1381 </ul>
1382 <br><br>
1383 <a href="#topofdoc">Back to top</a><br>
1384
1385 <a name="regmaps"></a>
1386 <h4><em>8052 Register Maps</em></h4>
1387 <hr>
1388
1389 Addresses of 8052 registers:
1390 <table border summary="">
1391 <tr><th>Bank</th><th>R0</th><th>R1</th><th>R2</th><th>R3</th><th>R4</th><th>R5</th><th>R6</th><th>R7</th></tr>
1392 <tr><td>0</td><td>00</td><td>01</td><td>02</td><td>03</td><td>04</td><td>05</td><td>06</td><td>07</td></tr>
1393 <tr><td>1</td><td>08</td><td>09</td><td>0A</td><td>0B</td><td>0C</td><td>0D</td><td>0E</td><td>0F</td></tr>
1394 <tr><td>2</td><td>10</td><td>11</td><td>12</td><td>13</td><td>14</td><td>15</td><td>16</td><td>17</td></tr>
1395 <tr><td>3</td><td>18</td><td>19</td><td>1A</td><td>1B</td><td>1C</td><td>1D</td><td>1E</td><td>1F</td></tr>
1396 </table>
1397
1398 <br><br>
1399 Addresses of 8052 Special Function Registers:
1400 <table border summary="">
1401 <tr><th>Address</th><th>Symbol</th><th>Name</th></tr>
1402 <tr><td> 80 </td><td> P0 </td><td> Port 0</td></tr>
1403 <tr><td> 81 </td><td> SP </td><td> Stack Pointer</td></tr>
1404 <tr><td> 82 </td><td> DPL </td><td> Data Pointer (low byte)</td></tr>
1405 <tr><td> 83 </td><td> DPH </td><td> Data Pointer (high byte)</td></tr>
1406 <tr><td> 87 </td><td> PCON </td><td> Power Control</td></tr>
1407 <tr><td> 88 </td><td> TCON </td><td> Timer/Counter Control</td></tr>
1408 <tr><td> 89 </td><td> TMOD </td><td> Timer/Counter Mode</td></tr>
1409 <tr><td> 8A </td><td> TL0 </td><td> Timer/Counter 0 (low byte)</td></tr>
1410 <tr><td> 8B </td><td> TL1 </td><td> Timer/Counter 1 (low byte)</td></tr>
1411 <tr><td> 8C </td><td> TH0 </td><td> Timer/Counter 0 (high byte)</td></tr>
1412 <tr><td> 8D </td><td> TH1 </td><td> Timer/Counter 1 (high byte)</td></tr>
1413 <tr><td> 90 </td><td> P1 </td><td> Port 1</td></tr>
1414 <tr><td> 98 </td><td> SCON </td><td> Serial Port Control</td></tr>
1415 <tr><td> 99 </td><td> SBUF </td><td> Serial Data Buffer</td></tr>
1416 <tr><td> A0 </td><td> P2 </td><td> Port 2</td></tr>
1417 <tr><td> A8 </td><td> IE </td><td> Interrupt Enable</td></tr>
1418 <tr><td> B0 </td><td> P3 </td><td> Port 3</td></tr>
1419 <tr><td> B8 </td><td> IP </td><td> Interrupt Priority</td></tr>
1420 <tr><td> D0 </td><td> PSW </td><td> Program Status Word</td></tr>
1421 <tr><td> E0 </td><td> ACC </td><td> Accumulator</td></tr>
1422 <tr><td> F0 </td><td> B </td><td> B Register</td></tr>
1423 </table>
1424 <br><br>
1425 <a href="#topofdoc">Back to top</a><br>
1426
1427 <a name="bsfr"></a>
1428 <h4><em>Bit Addressable Special Function Registers</em></h4>
1429
1430 <table border summary="">
1431 <tr><th>Address</th><th>Symbol</th><th>Bit name</th><th>Function</th></tr>
1432 <tr><td> 80-87 </td><td> P0.0-7 </td><td> </td><td>Port 0</td></tr>
1433 <tr><td> 88 </td><td> IT0 </td><td> TCON.0 </td><td>External Interrupt 0 Type Control</td></tr>
1434 <tr><td> 89 </td><td> IE0 </td><td> TCON.1 </td><td>External Interrupt 0 Edge Control</td></tr>
1435 <tr><td> 8A </td><td> IT1 </td><td> TCON.2 </td><td>External Interrupt 1 Type Control</td></tr>
1436 <tr><td> 8B </td><td> IE1 </td><td> TCON.3 </td><td>External Interrupt 1 Edge Control</td></tr>
1437 <tr><td> 8C </td><td> TR0 </td><td> TCON.4 </td><td>Timer 0 Run Control</td></tr>
1438 <tr><td> 8D </td><td> TF0 </td><td> TCON.5 </td><td>Timer 0 Overflow Flag</td></tr>
1439 <tr><td> 8E </td><td> TR1 </td><td> TCON.6 </td><td>Timer 1 Run Control</td></tr>
1440 <tr><td> 8F </td><td> TF1 </td><td> TCON.7 </td><td>Timer 1 Overflow Flag</td></tr>
1441 <tr><td> 90-97 </td><td> P1.0-7 </td><td> </td><td>Port 1</td></tr>
1442 <tr><td> 98 </td><td> RI </td><td> SCON.0 </td><td>Serial Receive Interrupt Flag</td></tr>
1443 <tr><td> 99 </td><td> TI </td><td> SCON.1 </td><td>Serial Transmit Interrupt Flag</td></tr>
1444 <tr><td> 9A </td><td> RB8 </td><td> SCON.2 </td><td>Serial Receive Bit 8</td></tr>
1445 <tr><td> 9B </td><td> TB8 </td><td> SCON.3 </td><td>Serial Transmit Bit 8</td></tr>
1446 <tr><td> 9C </td><td> REN </td><td> SCON.4 </td><td>Serial Receive Enable</td></tr>
1447 <tr><td> 9D </td><td> SM2 </td><td> SCON.5 </td><td>Serial Port Mode Specifier</td></tr>
1448 <tr><td> 9E </td><td> SM1 </td><td> SCON.6 </td><td>Serial Port Mode Specifier</td></tr>
1449 <tr><td> 9F </td><td> SM0 </td><td> SCON.7 </td><td>Serial Port Mode Specifier</td></tr>
1450 <tr><td> A0-A7 </td><td> P2.0-7 </td><td> </td><td>Port 2</td></tr>
1451 <tr><td> A8 </td><td> EX0 </td><td> IE.0 </td><td>Enable External Interrupt 0</td></tr>
1452 <tr><td> A9 </td><td> ET0 </td><td> IE.1 </td><td>Enable Timer 0 Interrupt</td></tr>
1453 <tr><td> AA </td><td> EX1 </td><td> IE.2 </td><td>Enable External Interrupt 1</td></tr>
1454 <tr><td> AB </td><td> ET1 </td><td> IE.3 </td><td>Enable Timer 1 Interrupt</td></tr>
1455 <tr><td> AC </td><td> ES </td><td> IE.4 </td><td>Enable Serial Port Interrupt</td></tr>
1456 <tr><td> AF </td><td> EA </td><td> IE.7 </td><td>Enable Interrupts</td></tr>
1457 <tr><td> B0-B7 </td><td> P3.0-7 </td><td> </td><td>Port 3</td></tr>
1458 <tr><td> B8 </td><td> PX0 </td><td> IP.0 </td><td>External Interrupt 0 Priority</td></tr>
1459 <tr><td> B9 </td><td> PT0 </td><td> IP.1 </td><td>Timer 0 Interrupt Priority</td></tr>
1460 <tr><td> BA </td><td> PX1 </td><td> IP.2 </td><td>External Interrupt 1 Priority</td></tr>
1461 <tr><td> BB </td><td> PT1 </td><td> IP.3 </td><td>Timer 1 Interrupt Priority</td></tr>
1462 <tr><td> BC </td><td> PS </td><td> IP.4 </td><td>Serial Port Interrupt Priority</td></tr>
1463 <tr><td> D0 </td><td> P </td><td> PSW.0 </td><td>Parity</td></tr>
1464 <tr><td> D2 </td><td> OV </td><td> PSW.2 </td><td>Overflow Flag</td></tr>
1465 <tr><td> D3 </td><td> RS0 </td><td> PSW.3 </td><td>Register Bank Select Bit 0</td></tr>
1466 <tr><td> D4 </td><td> RS1 </td><td> PSW.4 </td><td>Register Bank Select Bit 1</td></tr>
1467 <tr><td> D5 </td><td> F0 </td><td> PSW.5 </td><td>Flag 0 (general purpose flag)</td></tr>
1468 <tr><td> D6 </td><td> AC </td><td> PSW.6 </td><td>Auxiliary Carry Flag</td></tr>
1469 <tr><td> D7 </td><td> CY </td><td> PSW.7 </td><td>Carry Flag</td></tr>
1470 <tr><td> E0-E7 </td><td> ACC.0-7 </td><td> </td><td>Accumulator Bits</td></tr>
1471 <tr><td> F0-F7 </td><td> B.0-7 </td><td> </td><td>B Register Bits</td></tr>
1472 </table>
1473 <br><br>
1474 <a href="#topofdoc">Back to top</a><br>
1475
1476 <a name="bmem"></a>
1477 <h4><em>Addresses of Bit Addressable Memory Locations</em></h4>
1478
1479 <table border summary="">
1480 <tr><th>Address</th><th>Memory location</th></tr>
1481 <tr><td>00-07</td><td>20.0 - 20.7</td></tr>
1482 <tr><td>08-0F</td><td>21.0 - 21.7</td></tr>
1483 <tr><td>10-17</td><td>22.0 - 22.7</td></tr>
1484 <tr><td>18-1F</td><td>23.0 - 23.7</td></tr>
1485 <tr><td>20-27</td><td>24.0 - 24.7</td></tr>
1486 <tr><td>28-2F</td><td>25.0 - 25.7</td></tr>
1487 <tr><td>30-37</td><td>26.0 - 26.7</td></tr>
1488 <tr><td>38-3F</td><td>27.0 - 27.7</td></tr>
1489 <tr><td>40-47</td><td>28.0 - 28.7</td></tr>
1490 <tr><td>48-4F</td><td>29.0 - 29.7</td></tr>
1491 <tr><td>50-57</td><td>2A.0 - 2A.7</td></tr>
1492 <tr><td>58-5F</td><td>2B.0 - 2B.7</td></tr>
1493 <tr><td>60-67</td><td>2C.0 - 2C.7</td></tr>
1494 <tr><td>68-6F</td><td>2D.0 - 2D.7</td></tr>
1495 <tr><td>70-77</td><td>2E.0 - 2E.7</td></tr>
1496 <tr><td>78-7F</td><td>2F.0 - 2F.7</td></tr>
1497 </table>
1498 <br><br>
1499
1500 <a href="#topofdoc">Back to top</a><br>
1501 <br><br><br><br>
1502 </body>
1503 </html>