| 1 |
# |
| 2 |
# Copyright 2024 Centreon (http://www.centreon.com/) |
| 3 |
# |
| 4 |
# Centreon is a full-fledged industry-strength solution that meets |
| 5 |
# the needs in IT infrastructure and application monitoring for |
| 6 |
# service performance. |
| 7 |
# |
| 8 |
# Licensed under the Apache License, Version 2.0 (the "License"); |
| 9 |
# you may not use this file except in compliance with the License. |
| 10 |
# You may obtain a copy of the License at |
| 11 |
# |
| 12 |
# http://www.apache.org/licenses/LICENSE-2.0 |
| 13 |
# |
| 14 |
# Unless required by applicable law or agreed to in writing, software |
| 15 |
# distributed under the License is distributed on an "AS IS" BASIS, |
| 16 |
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| 17 |
# See the License for the specific language governing permissions and |
| 18 |
# limitations under the License. |
| 19 |
# |
| 20 |
|
| 21 |
package storage::hp::3par::ssh::mode::components::sensor; |
| 22 |
|
| 23 |
use strict; |
| 24 |
use warnings; |
| 25 |
use centreon::plugins::misc; |
| 26 |
|
| 27 |
sub load { |
| 28 |
my ($self) = @_; |
| 29 |
|
| 30 |
#Node 0 |
| 31 |
#--------- |
| 32 |
# |
| 33 |
#------Measurement------ -Reading- -Lo_Limit- -Hi_Limit- -----Status----- |
| 34 |
# Ambient 21 C 5 C 40 C Within Tolerance |
| 35 |
# Midplane 23 C 10 C 50 C Within Tolerance |
| 36 |
# PCM 0 inlet 27 C 10 C 50 C Within Tolerance |
| 37 |
# SBB Canister 1 memory 42 C 5 C 82 C Within Tolerance |
| 38 |
# PCM 0 (5V) 5.19 V --- --- Within Tolerance |
| 39 |
# PCM 0 (40A Max) 2.77 A --- --- Within Tolerance |
| 40 |
# PS0 Fan0 4380 RPM 1540 RPM 7140 RPM Within Tolerance |
| 41 |
# PS0 Fan1 4080 RPM 1540 RPM 7140 RPM Within Tolerance |
| 42 |
|
| 43 |
# |
| 44 |
#Node 1 |
| 45 |
#--------- |
| 46 |
# |
| 47 |
#------Measurement------ -Reading- -Lo_Limit- -Hi_Limit- -----Status----- |
| 48 |
# Ambient 21 C 5 C 40 C Within Tolerance |
| 49 |
# Midplane 23 C 10 C 50 C Within Tolerance |
| 50 |
# PCM 0 inlet 27 C 10 C 50 C Within Tolerance |
| 51 |
# PCM 0 hotspot 21 C 10 C 65 C Within Tolerance |
| 52 |
# Node Input PWR 87.6 W 0.0 W 264.0 W Within Tolerance |
| 53 |
# DDR40 VDDQ A 1.20 V 1.14 V 1.26 V Within Tolerance |
| 54 |
# DDR40 VPP A 2.48 V 2.37 V 2.75 V Within Tolerance |
| 55 |
# DDR40 VDDQ B 1.20 V 1.14 V 1.26 V Within Tolerance |
| 56 |
# DDR40 VPP B 2.48 V 2.37 V 2.75 V Within Tolerance |
| 57 |
|
| 58 |
push @{$self->{commands}}, 'echo "===shownodeenv==="', 'shownodeenv'; |
| 59 |
} |
| 60 |
|
| 61 |
sub check { |
| 62 |
my ($self) = @_; |
| 63 |
|
| 64 |
$self->{output}->output_add(long_msg => "Checking sensors"); |
| 65 |
$self->{components}->{sensor} = { name => 'sensors', total => 0, skip => 0 }; |
| 66 |
return if ($self->check_filter(section => 'sensor')); |
| 67 |
|
| 68 |
return if ($self->{results} !~ /===shownodeenv===.*?\n(.*?)(===|\Z)/msi); |
| 69 |
my $content = $1; |
| 70 |
my $unit_new_perf = { A => 'current.ampere', V => 'voltage.volt', W => 'power.watt', C => 'temperature.celsius', R => 'current.speed' }; |
| 71 |
|
| 72 |
while ($content =~ /^Node\s+(\d+)(.*?)(?=\nNode|\Z$)/msg) { |
| 73 |
my ($node_id, $measures) = ($1, $2); |
| 74 |
|
| 75 |
my @lines = split /\n/, $measures; |
| 76 |
foreach (@lines) { |
| 77 |
next if (!/^(.*?)\s+([\d.]+)\s+([CWAVR])P?M?\s+([\d.]+\s+[CWAVR]|---)P?M?\s+([\d.]+\s+[CWAVR]|---)P?M?\s+/); |
| 78 |
my ($name, $reading, $unit, $lo_limit, $hi_limit) = (centreon::plugins::misc::trim($1), $2, $3, $4, $5); |
| 79 |
my $instance = 'node' . $node_id . '.' . $name; |
| 80 |
|
| 81 |
next if ($self->check_filter(section => 'sensor', instance => $instance, name => $name)); |
| 82 |
$self->{components}->{sensor}->{total}++; |
| 83 |
|
| 84 |
$self->{output}->output_add( |
| 85 |
long_msg => sprintf( |
| 86 |
"sensor '%s' on node '%s' is %s %s [instance: %s]", |
| 87 |
$name, $node_id, $reading, $unit, $instance |
| 88 |
) |
| 89 |
); |
| 90 |
|
| 91 |
my ($exit, $warn, $crit, $checked) = $self->get_severity_numeric(section => 'sensor', instance => $instance, name => $name, value => $reading); |
| 92 |
$lo_limit = ($lo_limit =~ s/.*?(\d+(\.\d+)?).*/$1/) ? $lo_limit : undef; |
| 93 |
$hi_limit = ($hi_limit =~ s/.*?(\d+(\.\d+)?).*/$1/) ? $hi_limit : undef; |
| 94 |
if ($checked == 0 && (defined($lo_limit) || defined($hi_limit))) { |
| 95 |
my $warn_th = ''; |
| 96 |
my $crit_th = (defined($lo_limit) ? $lo_limit : '~') . ':' . (defined($hi_limit) ? $hi_limit : '~'); |
| 97 |
$self->{perfdata}->threshold_validate(label => 'warning-sensor-instance-' . $instance, value => $warn_th); |
| 98 |
$self->{perfdata}->threshold_validate(label => 'critical-sensor-instance-' . $instance, value => $crit_th); |
| 99 |
|
| 100 |
$exit = $self->{perfdata}->threshold_check( |
| 101 |
value => $reading, |
| 102 |
threshold => [ |
| 103 |
{ label => 'critical-sensor-instance-' . $instance, exit_litteral => 'critical' }, |
| 104 |
{ label => 'warning-sensor-instance-' . $instance, exit_litteral => 'warning' } |
| 105 |
] |
| 106 |
); |
| 107 |
$warn = $self->{perfdata}->get_perfdata_for_output(label => 'warning-sensor-instance-' . $instance); |
| 108 |
$crit = $self->{perfdata}->get_perfdata_for_output(label => 'critical-sensor-instance-' . $instance); |
| 109 |
} |
| 110 |
|
| 111 |
if (!$self->{output}->is_status(value => $exit, compare => 'ok', litteral => 1)) { |
| 112 |
$self->{output}->output_add( |
| 113 |
severity => $exit, |
| 114 |
short_msg => sprintf("Sensor '%s' on node '%s' is %s %s ", $name, $node_id, $reading, $unit) |
| 115 |
); |
| 116 |
} |
| 117 |
|
| 118 |
$self->{output}->perfdata_add( |
| 119 |
nlabel => 'hardware.sensor.' . $unit_new_perf->{$unit}, |
| 120 |
unit => $unit, |
| 121 |
instances => ['node' . $node_id, $name], |
| 122 |
value => $reading, |
| 123 |
warning => $warn, |
| 124 |
critical => $crit, |
| 125 |
); |
| 126 |
} |
| 127 |
} |
| 128 |
} |
| 129 |
|
| 130 |
1; |