Debian Codegraph @

src/hardware/ups/apc/snmp/mode/batterystatus.pm

raw
1 #
2 # Copyright 2024 Centreon (http://www.centreon.com/)
3 #
4 # Centreon is a full-fledged industry-strength solution that meets
5 # the needs in IT infrastructure and application monitoring for
6 # service performance.
7 #
8 # Licensed under the Apache License, Version 2.0 (the "License");
9 # you may not use this file except in compliance with the License.
10 # You may obtain a copy of the License at
11 #
12 # http://www.apache.org/licenses/LICENSE-2.0
13 #
14 # Unless required by applicable law or agreed to in writing, software
15 # distributed under the License is distributed on an "AS IS" BASIS,
16 # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
17 # See the License for the specific language governing permissions and
18 # limitations under the License.
19 #
20
21 package hardware::ups::apc::snmp::mode::batterystatus;
22
23 use base qw(centreon::plugins::templates::counter);
24
25 use strict;
26 use warnings;
27 use DateTime::Format::Strptime;
28 use DateTime;
29 use centreon::plugins::templates::catalog_functions qw(catalog_status_threshold_ng);
30
31 sub custom_battery_status_output {
32 my ($self, %options) = @_;
33
34 return sprintf(
35 "battery status is '%s' [battery needs replace: %s] [last replace date: %s]",
36 $self->{result_values}->{status},
37 $self->{result_values}->{replace},
38 $self->{result_values}->{last_replace_date}
39 );
40 }
41
42 sub custom_status_calc {
43 my ($self, %options) = @_;
44
45 $self->{result_values}->{status} = $options{new_datas}->{$self->{instance} . '_upsBasicBatteryStatus'};
46 $self->{result_values}->{replace} = $options{new_datas}->{$self->{instance} . '_upsAdvBatteryReplaceIndicator'};
47 $self->{result_values}->{last_replace_date} = $options{new_datas}->{$self->{instance} . '_upsBasicBatteryLastReplaceDate'};
48 return 0;
49 }
50
51 sub custom_status_output {
52 my ($self, %options) = @_;
53
54 return sprintf(
55 "status is '%s'",
56 $self->{result_values}->{status}
57 );
58 }
59
60 sub bpack_long_output {
61 my ($self, %options) = @_;
62
63 return "checking battery pack '" . $options{instance_value}->{display} . "'";
64 }
65
66 sub prefix_bpack_output {
67 my ($self, %options) = @_;
68
69 return "battery pack '" . $options{instance_value}->{display} . "' ";
70 }
71
72 sub prefix_cartridge_output {
73 my ($self, %options) = @_;
74
75 return "cartridge '" . $options{instance_value}->{display} . "' ";
76 }
77
78 sub set_counters {
79 my ($self, %options) = @_;
80
81 $self->{maps_counters_type} = [
82 { name => 'global', type => 0, skipped_code => { -10 => 1 } },
83 { name => 'bpacks', type => 3, cb_prefix_output => 'prefix_bpack_output', cb_long_output => 'bpack_long_output', indent_long_output => ' ', message_multiple => 'All battery packs are ok',
84 group => [
85 { name => 'bpack_global', type => 0, skipped_code => { -10 => 1 } },
86 { name => 'cartridges', display_long => 1, cb_prefix_output => 'prefix_cartridge_output', message_multiple => 'cartridges are ok', type => 1, skipped_code => { -10 => 1 } }
87 ]
88 }
89 ];
90
91 $self->{maps_counters}->{global} = [
92 {
93 label => 'status',
94 type => 2,
95 unknown_default => '%{status} =~ /unknown/i',
96 warning_default => '%{status} =~ /batteryLow/i',
97 critical_default => '%{replace} =~ /yes/i',
98 set => {
99 key_values => [
100 { name => 'upsBasicBatteryStatus' },
101 { name => 'upsAdvBatteryReplaceIndicator' },
102 { name => 'upsBasicBatteryLastReplaceDate' }
103 ],
104 closure_custom_calc => $self->can('custom_status_calc'),
105 closure_custom_output => $self->can('custom_battery_status_output'),
106 closure_custom_perfdata => sub { return 0; },
107 closure_custom_threshold_check => \&catalog_status_threshold_ng
108 }
109 },
110 { label => 'load', nlabel => 'battery.charge.remaining.percent', set => {
111 key_values => [ { name => 'upsAdvBatteryCapacity' } ],
112 output_template => 'remaining capacity: %s %%',
113 perfdatas => [
114 { label => 'load', template => '%s', min => 0, max => 100, unit => '%' }
115 ]
116 }
117 },
118 { label => 'time', nlabel => 'battery.charge.remaining.minutes', set => {
119 key_values => [ { name => 'upsAdvBatteryRunTimeRemaining' } ],
120 output_template => 'remaining time: %.2f minutes',
121 perfdatas => [
122 { label => 'load_time', template => '%.2f', min => 0, unit => 'm' }
123 ]
124 }
125 },
126 { label => 'timeon', nlabel => 'battery.timeon.minutes', set => {
127 key_values => [ { name => 'upsBasicBatteryTimeOnBattery' } ],
128 output_template => 'time on battery: %.2f minutes',
129 perfdatas => [
130 { label => 'timeon', template => '%.2f', min => 0, unit => 'm' }
131 ]
132 }
133 },
134 { label => 'current', nlabel => 'battery.current.ampere', set => {
135 key_values => [ { name => 'upsAdvBatteryCurrent' } ],
136 output_template => 'current: %s A',
137 perfdatas => [
138 { label => 'current', template => '%s', min => 0, unit => 'A' }
139 ]
140 }
141 },
142 { label => 'voltage', nlabel => 'battery.voltage.volt', set => {
143 key_values => [ { name => 'upsAdvBatteryActualVoltage' } ],
144 output_template => 'voltage: %s V',
145 perfdatas => [
146 { label => 'voltage', template => '%s', unit => 'V' }
147 ]
148 }
149 },
150 { label => 'temperature', nlabel => 'battery.temperature.celsius', set => {
151 key_values => [ { name => 'upsAdvBatteryTemperature' } ],
152 output_template => 'temperature: %s C',
153 perfdatas => [
154 { label => 'temperature', template => '%s', unit => 'C'}
155 ]
156 }
157 },
158 { label => 'replace-lasttime', nlabel => 'battery.replace.lasttime.seconds', display_ok => 0, set => {
159 key_values => [ { name => 'last_replace_time' } ],
160 output_template => 'replace last time: %s s',
161 perfdatas => [
162 { label => 'replace_last_time', template => '%s', unit => 's'}
163 ]
164 }
165 }
166 ];
167
168 $self->{maps_counters}->{bpack_global} = [
169 { label => 'battery-pack-status', type => 2, critical_default => '%{status} ne "OK"', set => {
170 key_values => [ { name => 'status' }, { name => 'display' } ],
171 closure_custom_output => $self->can('custom_status_output'),
172 closure_custom_perfdata => sub { return 0; },
173 closure_custom_threshold_check => \&catalog_status_threshold_ng
174 }
175 }
176 ];
177
178 $self->{maps_counters}->{cartridges} = [
179 { label => 'cartridge-status', type => 2, critical_default => '%{status} ne "OK"', set => {
180 key_values => [ { name => 'status' }, { name => 'display' } ],
181 closure_custom_output => $self->can('custom_status_output'),
182 closure_custom_perfdata => sub { return 0; },
183 closure_custom_threshold_check => \&catalog_status_threshold_ng
184 }
185 }
186 ];
187 }
188
189 sub new {
190 my ($class, %options) = @_;
191 my $self = $class->SUPER::new(package => __PACKAGE__, %options, force_new_perfdata => 1);
192 bless $self, $class;
193
194 $options{options}->add_options(arguments => {
195 'replace-lasttime-format:s' => { name => 'replace_lasttime_format' }
196 });
197
198 return $self;
199 }
200
201 sub check_options {
202 my ($self, %options) = @_;
203 $self->SUPER::check_options(%options);
204
205 my $pattern = '%m/%d/%Y';
206 if (defined($self->{option_results}->{replace_lasttime_format}) && $self->{option_results}->{replace_lasttime_format} ne '') {
207 $pattern = $self->{option_results}->{replace_lasttime_format};
208 }
209
210 $self->{strp} = DateTime::Format::Strptime->new(
211 pattern => $pattern,
212 on_error => 'undef'
213 );
214 }
215
216 my $map_battery_status = {
217 1 => 'unknown', 2 => 'batteryNormal', 3 => 'batteryLow'
218 };
219 my $map_replace_status = {
220 1 => 'no', 2 => 'yes'
221 };
222
223 my $mapping = {
224 upsBasicBatteryStatus => { oid => '.1.3.6.1.4.1.318.1.1.1.2.1.1', map => $map_battery_status },
225 upsBasicBatteryTimeOnBattery => { oid => '.1.3.6.1.4.1.318.1.1.1.2.1.2' },
226 upsBasicBatteryLastReplaceDate => { oid => '.1.3.6.1.4.1.318.1.1.1.2.1.3' }
227 };
228 my $mapping2 = {
229 upsAdvBatteryCapacity => { oid => '.1.3.6.1.4.1.318.1.1.1.2.2.1' },
230 upsAdvBatteryTemperature => { oid => '.1.3.6.1.4.1.318.1.1.1.2.2.2' },
231 upsAdvBatteryRunTimeRemaining => { oid => '.1.3.6.1.4.1.318.1.1.1.2.2.3' },
232 upsAdvBatteryReplaceIndicator => { oid => '.1.3.6.1.4.1.318.1.1.1.2.2.4', map => $map_replace_status },
233 upsAdvBatteryActualVoltage => { oid => '.1.3.6.1.4.1.318.1.1.1.2.2.8' },
234 upsAdvBatteryCurrent => { oid => '.1.3.6.1.4.1.318.1.1.1.2.2.9' }
235 };
236 my $oid_upsBasicBattery = '.1.3.6.1.4.1.318.1.1.1.2.1';
237 my $oid_upsAdvBattery = '.1.3.6.1.4.1.318.1.1.1.2.2';
238 my $oid_upsHighPrecBatteryPackOnlyStatus = '.1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.5';
239 my $oid_upsHighPrecBatteryPackCartridgeStatus = '.1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.10';
240
241 my $map_battery_pack_status = {
242 0 => 'disconnected', 1 => 'overvoltage',
243 2 => 'needsReplacement', 3 => 'overtemperatureCritical',
244 4 => 'charger', 5 => 'temperatureSensor',
245 6 => 'busSoftStart', 7 => 'overtemperatureWarning',
246 8 => 'generalError', 9 => 'communication',
247 10 => 'disconnectedFrame', 11 => 'firmwareMismatch'
248 };
249
250 sub add_battery_pack {
251 my ($self, %options) = @_;
252
253 $self->{bpacks} = {};
254 foreach my $oid (keys %{$options{snmp_result}->{$oid_upsHighPrecBatteryPackOnlyStatus}}) {
255 next if ($options{snmp_result}->{$oid_upsHighPrecBatteryPackOnlyStatus}->{$oid} eq '');
256
257 $oid =~ /^$oid_upsHighPrecBatteryPackOnlyStatus\.(\d+)/;
258 my $pack_index = $1;
259 $self->{bpacks}->{$pack_index} = {
260 display => $pack_index,
261 bpack_global => {
262 display => $pack_index,
263 status => 'OK'
264 },
265 cartridges => {}
266 };
267
268 my $status = '';
269 my ($i, $append) = (0, '');
270 foreach my $bit (split //, $options{snmp_result}->{$oid_upsHighPrecBatteryPackOnlyStatus}->{$oid}) {
271 if ($bit) {
272 $status .= $append . $map_battery_pack_status->{$i};
273 $append = ',';
274 }
275 $i++;
276 }
277
278 $self->{bpacks}->{$pack_index}->{bpack_global}->{status} = $status if ($status ne '');
279 }
280
281 foreach my $oid (keys %{$options{snmp_result}->{$oid_upsHighPrecBatteryPackCartridgeStatus}}) {
282 next if ($options{snmp_result}->{$oid_upsHighPrecBatteryPackCartridgeStatus}->{$oid} eq '');
283
284 $oid =~ /^$oid_upsHighPrecBatteryPackCartridgeStatus\.(\d+)\.\d+\.(\d+)/;
285 my ($pack_index, $cartridge_index) = ($1, $2);
286 if (!defined($self->{bpacks}->{$pack_index})) {
287 $self->{bpacks}->{$pack_index} = {
288 display => $pack_index,
289 cartridges => {}
290 };
291 }
292
293 $self->{bpacks}->{$pack_index}->{cartridges}->{$cartridge_index} = {
294 display => $cartridge_index,
295 status => 'OK'
296 };
297
298 my $status = '';
299 my ($i, $append) = (0, '');
300 foreach my $bit (split //, $options{snmp_result}->{$oid_upsHighPrecBatteryPackCartridgeStatus}->{$oid}) {
301 if ($bit) {
302 $status .= $append . $map_battery_pack_status->{$i};
303 $append = ',';
304 }
305 $i++;
306 }
307
308 $self->{bpacks}->{$pack_index}->{cartridges}->{$cartridge_index}->{status} = $status if ($status ne '');
309 }
310 }
311
312 sub manage_selection {
313 my ($self, %options) = @_;
314
315 my $snmp_result = $options{snmp}->get_multiple_table(
316 oids => [
317 { oid => $oid_upsBasicBattery },
318 { oid => $oid_upsAdvBattery, end => $mapping2->{upsAdvBatteryCurrent}->{oid} },
319 { oid => $oid_upsHighPrecBatteryPackCartridgeStatus },
320 { oid => $oid_upsHighPrecBatteryPackOnlyStatus }
321 ],
322 nothing_quit => 1
323 );
324
325 $self->{global} = {};
326 my $result = $options{snmp}->map_instance(mapping => $mapping, results => $snmp_result->{$oid_upsBasicBattery}, instance => '0');
327 my $result2 = $options{snmp}->map_instance(mapping => $mapping2, results => $snmp_result->{$oid_upsAdvBattery}, instance => '0');
328
329 $result->{upsBasicBatteryTimeOnBattery} = sprintf('%.0f', $result->{upsBasicBatteryTimeOnBattery} / 100 / 60)
330 if (defined($result->{upsBasicBatteryTimeOnBattery}));
331 $result2->{upsAdvBatteryRunTimeRemaining} = sprintf("%.0f", $result2->{upsAdvBatteryRunTimeRemaining} / 100 / 60)
332 if (defined($result2->{upsAdvBatteryRunTimeRemaining}));
333 $result2->{upsAdvBatteryReplaceIndicator} = 'n/a'
334 if (!defined($result2->{upsAdvBatteryReplaceIndicator}));
335 $self->{global} = { %$result, %$result2 };
336
337 if (defined($result->{upsBasicBatteryLastReplaceDate}) && $result->{upsBasicBatteryLastReplaceDate} ne '') {
338 my $dt = $self->{strp}->parse_datetime($result->{upsBasicBatteryLastReplaceDate});
339 if (defined($dt)) {
340 $self->{global}->{last_replace_time} = time() - $dt->epoch();
341 } else {
342 $self->{output}->output_add(long_msg => "cannot parse date: " . $result->{upsBasicBatteryLastReplaceDate} . ' (please use option --replace-lasttime-format)');
343 }
344 }
345
346 $self->add_battery_pack(snmp_result => $snmp_result);
347
348 }
349
350 1;
351
352 __END__
353
354 =head1 MODE
355
356 Check battery status and battery charge remaining.
357
358 =over 8
359
360 =item B<--filter-counters>
361
362 Only display some counters (regexp can be used).
363 Example: --filter-counters='^status|load$'
364
365 =item B<--replace-lasttime-format>
366
367 Define the date format (default: '%m/%d/%Y').
368
369 =item B<--unknown-status>
370
371 Define the conditions to match for the status to be UNKNOWN (default: '%{status} =~ /unknown/i').
372 You can use the following variables: %{status}, %{replace}
373
374 =item B<--warning-status>
375
376 Define the conditions to match for the status to be WARNING (default: '%{status} =~ /batteryLow/i').
377 You can use the following variables: %{status}, %{replace}
378
379 =item B<--critical-status>
380
381 Define the conditions to match for the status to be CRITICAL (default: '%{replace} =~ /yes/i').
382 You can use the following variables: %{status}, %{replace}
383
384 =item B<--unknown-battery-pack-status>
385
386 Define the conditions to match for the status to be UNKNOWN.
387 You can use the following variables: %{status}
388
389 =item B<--warning-battery-pack-status>
390
391 Define the conditions to match for the status to be WARNING.
392 You can use the following variables: %{status}
393
394 =item B<--critical-battery-pack-status>
395
396 Define the conditions to match for the status to be CRITICAL (default: '%{status} ne "OK"').
397 You can use the following variables: %{status}
398
399 =item B<--unknown-cartridge-status>
400
401 Define the conditions to match for the status to be UNKNOWN.
402 You can use the following variables: %{status}
403
404 =item B<--warning-cartridge-status>
405
406 Define the conditions to match for the status to be WARNING.
407 You can use the following variables: %{status}
408
409 =item B<--critical-cartridge-status>
410
411 Define the conditions to match for the status to be CRITICAL (default: '%{status} ne "OK"').
412 You can use the following variables: %{status}
413
414 =item B<--warning-*> B<--critical-*>
415
416 Thresholds.
417 Can be: 'load', 'voltage', 'current',
418 'temperature', 'time', 'replace-lasttime', 'timeon'.
419
420 =back
421
422 =cut