| 1 |
+++ |
| 2 |
title = "SphericalDetector" |
| 3 |
weight = 10 |
| 4 |
+++ |
| 5 |
|
| 6 |
## SphericalDetector |
| 7 |
|
| 8 |
For SAS and GISAS simulations, |
| 9 |
the two-dimensional area detector is modelled by |
| 10 |
the {{% ref-class "Device/Detector" "SphericalDetector" %}} class. |
| 11 |
|
| 12 |
### Geometry |
| 13 |
|
| 14 |
A `SphericalDetector` is a 2D detector defined in angular coordinates. |
| 15 |
All pixels have equal size. |
| 16 |
|
| 17 |
{{< figscg src="/img/draw/detector1.svg" width="100%" >}} |
| 18 |
|
| 19 |
In BornAgain, detector images are shown as seen from the back of the detector. |
| 20 |
In this way we ensure that the $\varphi$ or $q_y$ axis has the same |
| 21 |
orientation as the real-space $y$ axis. |
| 22 |
|
| 23 |
For plotting and data import and export, |
| 24 |
BornAgain pretends that the detector bins correspond to |
| 25 |
bins of constant width in $\varphi$ or $q_y$ and $\alpha$ or $q_z$, |
| 26 |
even though this is only true in first approximation. |
| 27 |
|
| 28 |
For the actual scattering computation, BornAgain uses true scattering angles, |
| 29 |
computed as nonlinear functions of the pixel coordinates. |
| 30 |
|
| 31 |
Further distortions arise |
| 32 |
if the detector is not perpendicular to the `x` axis. |
| 33 |
This is not unlikely in GISAS |
| 34 |
where it makes sense to position the detector perpendicular |
| 35 |
to the reflected or transmitted beam. |
| 36 |
Corrections for these and other distortions will be implemented |
| 37 |
when requested by users. |
| 38 |
|
| 39 |
### Constructor |
| 40 |
|
| 41 |
The constructor has the signature |
| 42 |
``` |
| 43 |
detector = ba.SphericalDetector(n_phi, phi_min, phi_max, n_alpha, alpha_min, alpha_max) |
| 44 |
``` |
| 45 |
|
| 46 |
The arguments `phi_min, phi_max, alpha_min, alpha_max` define the range of the detector in |
| 47 |
direction $\varphi_\text{f},\alpha_\text{f}$. |
| 48 |
|
| 49 |
The arguments `n_phi, n_alpha` are the number of bins per direction; |
| 50 |
their product is the number of pixels of the detector. |
| 51 |
|
| 52 |
### Masks |
| 53 |
|
| 54 |
When fitting theoretical models to measured diffraction images, |
| 55 |
it can be helpful to mask part of the detector area. |
| 56 |
See |
| 57 |
|
| 58 |
* [Fit with masks](/ref/fit/ex/fit-with-masks) |
| 59 |
|
| 60 |
### Resolution |
| 61 |
|
| 62 |
For modeling the detector resolution, see [Detector resolution](/ref/instr/det/resolution). |
| 63 |
|
| 64 |
### History |
| 65 |
|
| 66 |
Until BornAgain 21, we had a `RectangularDetector` and a `SphericalDetector`. |