| 1 |
#!/usr/bin/python |
| 2 |
# -*- coding: utf-8 -*- |
| 3 |
|
| 4 |
# (c) 2022, John McCall (@lowlydba) |
| 5 |
# GNU General Public License v3.0+ (see COPYING or https://www.gnu.org/licenses/gpl-3.0.txt) |
| 6 |
|
| 7 |
DOCUMENTATION = r''' |
| 8 |
--- |
| 9 |
module: maintenance_solution |
| 10 |
short_description: Install/update Maintenance Solution by Ola Hallengren |
| 11 |
description: |
| 12 |
- A wrapper for C(Install-DbaMaintenanceSolution) to fetch the latest version of the Ola Hallengren's Maintenance Solution, |
| 13 |
or install from a local cached version. |
| 14 |
version_added: 0.1.0 |
| 15 |
options: |
| 16 |
backup_location: |
| 17 |
description: |
| 18 |
- Location of the backup root directory. If this is not supplied, the default backup directory will be used. |
| 19 |
type: str |
| 20 |
required: false |
| 21 |
cleanup_time: |
| 22 |
description: |
| 23 |
- Time in hours, after which backup files are deleted. |
| 24 |
type: int |
| 25 |
required: false |
| 26 |
default: 0 |
| 27 |
output_file_dir: |
| 28 |
description: |
| 29 |
- Specify the output file directory where the Maintenance Solution will write to. |
| 30 |
type: str |
| 31 |
required: false |
| 32 |
replace_existing: |
| 33 |
description: |
| 34 |
- If this switch is enabled, objects already present in the target database will be dropped and recreated. |
| 35 |
type: bool |
| 36 |
required: false |
| 37 |
log_to_table: |
| 38 |
description: |
| 39 |
- If this switch is enabled, the Maintenance Solution will be configured to log commands to a table. |
| 40 |
type: bool |
| 41 |
required: false |
| 42 |
default: false |
| 43 |
solution: |
| 44 |
description: |
| 45 |
- Specifies which portion of the Maintenance Solution to install. |
| 46 |
type: str |
| 47 |
required: false |
| 48 |
default: 'All' |
| 49 |
choices: ['All', 'Backup', 'IntegrityCheck', 'IndexOptimize'] |
| 50 |
install_jobs: |
| 51 |
description: |
| 52 |
- If this switch is enabled, the corresponding SQL Agent Jobs will be created. |
| 53 |
type: bool |
| 54 |
required: false |
| 55 |
default: false |
| 56 |
install_parallel: |
| 57 |
description: |
| 58 |
- If this switch is enabled, the C(Queue) and C(QueueDatabase) tables are created, for use when C(@DatabasesInParallel = 'Y') are set in the jobs. |
| 59 |
type: bool |
| 60 |
required: false |
| 61 |
default: false |
| 62 |
local_file: |
| 63 |
description: |
| 64 |
- Specifies the path to a local file to install Ola's solution from. This should be the zip file as distributed by the maintainers. |
| 65 |
- If this option is not specified, the latest version will be downloaded and installed |
| 66 |
from the L(Maintenance Solution Github,https://github.com/olahallengren/sql-server-maintenance-solution). |
| 67 |
type: str |
| 68 |
required: false |
| 69 |
database: |
| 70 |
description: |
| 71 |
- Name of the target database. |
| 72 |
type: str |
| 73 |
required: true |
| 74 |
force: |
| 75 |
description: |
| 76 |
- If this switch is enabled, the Maintenance Solution will be downloaded from the internet even if previously cached. |
| 77 |
type: bool |
| 78 |
default: false |
| 79 |
author: "John McCall (@lowlydba)" |
| 80 |
requirements: |
| 81 |
- L(dbatools,https://www.powershellgallery.com/packages/dbatools/) PowerShell module |
| 82 |
extends_documentation_fragment: |
| 83 |
- lowlydba.sqlserver.sql_credentials |
| 84 |
- lowlydba.sqlserver.attributes.check_mode |
| 85 |
- lowlydba.sqlserver.attributes.platform_all |
| 86 |
''' |
| 87 |
|
| 88 |
EXAMPLES = r''' |
| 89 |
- name: Install/Update Maintenance Solution |
| 90 |
lowlydba.sqlserver.multitool: |
| 91 |
sql_instance: sql-01.myco.io |
| 92 |
database: main |
| 93 |
replace_existing: true |
| 94 |
''' |
| 95 |
|
| 96 |
RETURN = r''' |
| 97 |
data: |
| 98 |
description: Output from the C(Install-MaintenanceSolution) function. |
| 99 |
returned: success, but not in check_mode. |
| 100 |
type: dict |
| 101 |
''' |