| 1 |
|
| 2 |
|
| 3 |
This directory contains utilities for running the ACE+TAO test suite on |
| 4 |
a LabVIEW RT 8 / Phar Lap ETS target. Although it's running Phar Lap ETS, |
| 5 |
and thus would normally be able to run programs, this environment is |
| 6 |
different than plain Phar Lap ETS in that the LabVIEW RT layer takes up |
| 7 |
the only process able to run on Phar Lap. Thus, everything executed needs |
| 8 |
to be done via LabVIEW RT facilities. Thus, we have the following |
| 9 |
restrictions: |
| 10 |
|
| 11 |
1. There's no NFS, no SMB; there's a target filesystem but no direct access. |
| 12 |
2. No executables can be directly executed. |
| 13 |
|
| 14 |
This yields the following: |
| 15 |
|
| 16 |
- All test "programs" are built as DLLs instead of executables. The DLL has |
| 17 |
a known "main" entrypoint. To run the test, the DLL must be copied down |
| 18 |
to the target, explicitly loaded, and its entrypoint called. MPC will |
| 19 |
automatically build these DLLs when an executable is specified in the MPC |
| 20 |
file by basing the MPC project on the labviewrt_dll.mpb base. This is done |
| 21 |
by supplying "-base labviewrt_dll" on the MPC command line. |
| 22 |
|
| 23 |
- There is a test-controlling DLL that lives on the LabVIEW RT target, and is |
| 24 |
loaded when the target boots. This DLL spawns a thread that listens on a |
| 25 |
TCP port for connections; it runs a text-based protocol by which it can |
| 26 |
be directed to load and run test DLLs and report results. This DLL is in |
| 27 |
the labview_test_controller subdirectory; see its ReadMe.txt file for |
| 28 |
more details. |
| 29 |
|
| 30 |
- The Perl test framework in PerlACE has a ProcessLVRT.pm and |
| 31 |
TestTarget_LVRT.pm that know how to run the test protocol, get the log file |
| 32 |
back from the target, etc. in order to integrate the LabVIEW RT scheme into |
| 33 |
the ACE+TAO testing framework. |
| 34 |
|
| 35 |
- If a test encounters any significant errors that would produce something akin |
| 36 |
to a crash or significant leak on a multi-process OS, it will probably |
| 37 |
render the LabVIEW RT target unuseable and unresponsive. There are two |
| 38 |
utilities in this directory that will help in this sort of situation: |
| 39 |
|
| 40 |
1. Reboot_Target.exe: A Windows executable that runs a LabVIEW VI to |
| 41 |
reboot a local target box. If the box is alive enough to be contacted |
| 42 |
and run the LabVIEW VI that triggers the reboot, this works fine. |
| 43 |
However, if the box is unresponsive, as it usually is, this doesn't |
| 44 |
work. The advantage of this utility is that it doesn't require any |
| 45 |
additional hardware or software. |
| 46 |
|
| 47 |
2. PXI_Reset.exe: A Windows executable that runs a LabVIEW VI to |
| 48 |
trigger a hardware reset on the target box. This utility works all |
| 49 |
the time since it does a hardware reset. However, it requires an |
| 50 |
additional piece of hardware that connects to the host PC via USB |
| 51 |
and connects to the DB9 on the back of the PXI target. This little |
| 52 |
hardware box was custom-made by Lockheed Martin, so you can't just |
| 53 |
go buy one at Radio Shack. |
| 54 |
|
| 55 |
If neither of these utilities is workable for you, you can probably use a |
| 56 |
programmable power strip that can cycle the power on the target, and write |
| 57 |
a utility that drives it. |