\name{xcusum.crit.L0L1} \alias{xcusum.crit.L0L1} \title{Compute the CUSUM k and h for given in-control ARL L0 and out-of-control L1} \description{Computation of the reference value k and the alarm threshold h for one-sided CUSUM control charts monitoring normal mean, if the in-control ARL L0 and the out-of-control L1 are given.} \usage{xcusum.crit.L0L1(L0, L1, hs=0, sided="one", r=30, L1.eps=1e-6, k.eps=1e-8)} \arguments{ \item{L0}{in-control ARL.} \item{L1}{out-of-control ARL.} \item{hs}{so-called headstart (enables fast initial response).} \item{sided}{distinguishes between one-, two-sided and Crosier's modified two-sided CUSUM schemoosing \code{"one"}, \code{"two"}, and \code{"Crosier"}, respectively.} \item{r}{number of quadrature nodes, dimension of the resulting linear equation system is equal to \code{r+1} (one-, two-sided) or \code{2r+1} (Crosier).} \item{L1.eps}{error bound for the L1 error.} \item{k.eps}{bound for the difference of two successive values of k.} } \details{ \code{xcusum.crit.L0L1} determines the reference value k and the alarm threshold h for given in-control ARL \code{L0} and out-of-control ARL \code{L1} by applying secant rule and using \code{xcusum.arl()} and \code{xcusum.crit()}. These CUSUM design rules were firstly (and quite rarely afterwards) used by Ewan and Kemp. } \value{Returns two values which resemble the reference value \code{k} and the threshold \code{h}.} \references{ W. D. Ewan and K. W. Kemp (1960), Sampling inspection of continuous processes with no autocorrelation between successive results, \emph{Biometrika 47}, 363-380. K. W. Kemp (1962), The Use of Cumulative Sums for Sampling Inspection Schemes, \emph{Journal of the Royal Statistical Sociecty C, Applied Statistics, 10}, 16-31. } \author{Sven Knoth} \seealso{\code{xcusum.arl} for zero-state ARL and \code{xcusum.crit} for threshold h computation.} \examples{ ## Table 2 from Ewan/Kemp (1960) -- one-sided CUSUM # # A.R.L. at A.Q.L. A.R.L. at A.Q.L. k h # 1000 3 1.12 2.40 # 1000 7 0.65 4.06 # 500 3 1.04 2.26 # 500 7 0.60 3.80 # 250 3 0.94 2.11 # 250 7 0.54 3.51 # L0.set <- c(1000, 500, 250) L1.set <- c(3, 7) cat("\nL0\tL1\tk\th\n") for ( L0 in L0.set ) { for ( L1 in L1.set ) { result <- round(xcusum.crit.L0L1(L0, L1), digits=2) cat(paste(L0, L1, result[1], result[2], sep="\t"), "\n") } } # # two confirmation runs xcusum.arl(0.54, 3.51, 0) # Ewan/Kemp xcusum.arl(result[1], result[2], 0) # here xcusum.arl(0.54, 3.51, 2*0.54) # Ewan/Kemp xcusum.arl(result[1], result[2], 2*result[1]) # here # ## Table II from Kemp (1962) -- two-sided CUSUM # # Lr k # La=250 La=500 La=1000 # 2.5 1.05 1.17 1.27 # 3.0 0.94 1.035 1.13 # 4.0 0.78 0.85 0.92 # 5.0 0.68 0.74 0.80 # 6.0 0.60 0.655 0.71 # 7.5 0.52 0.57 0.62 # 10.0 0.43 0.48 0.52 # L0.set <- c(250, 500, 1000) L1.set <- c(2.5, 3:6, 7.5, 10) cat("\nL1\tL0=250\tL0=500\tL0=1000\n") for ( L1 in L1.set ) { cat(L1) for ( L0 in L0.set ) { result <- round(xcusum.crit.L0L1(L0, L1, sided="two"), digits=2) cat("\t", result[1]) } cat("\n") } } \keyword{ts}