# # This file is part of the PyMeasure package. # # Copyright (c) 2013-2024 PyMeasure Developers # # Permission is hereby granted, free of charge, to any person obtaining a copy # of this software and associated documentation files (the "Software"), to deal # in the Software without restriction, including without limitation the rights # to use, copy, modify, merge, publish, distribute, sublicense, and/or sell # copies of the Software, and to permit persons to whom the Software is # furnished to do so, subject to the following conditions: # # The above copyright notice and this permission notice shall be included in # all copies or substantial portions of the Software. # # THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR # IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, # FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE # AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER # LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, # OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN # THE SOFTWARE. # # ============================================================================= # Libraries / modules # ============================================================================= from .tdk_base import TDK_Lambda_Base # ============================================================================= # Instrument file # ============================================================================= class TDK_Gen80_65(TDK_Lambda_Base): """ Represents the TDK Lambda Genesys 80-65 DC power supply. Class inherits commands from the TDK_Lambda_Base parent class and utilizes dynamic properties adjust valid values on various properties. .. code-block:: python psu = TDK_Gen80_65("COM3", 6) # COM port and daisy-chain address psu.remote = "REM" # PSU in remote mode psu.output_enabled = True # Turn on output psu.ramp_to_current(2.0) # Ramp to 2.0 A of current print(psu.current) # Measure actual PSU current print(psu.voltage) # Measure actual PSU voltage psu.shutdown() # Run shutdown command The initialization of a TDK instrument requires the current address of the TDK power supply. The default address for the TDK Lambda is 6. :param adapter: VISAAdapter instance :param name: Instrument name. Default is "TDK Lambda Gen80-65" :param address: Serial port daisy chain number. Default is 6. """ # ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ # Dynamic values - Overrides base class validator values # ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ voltage_values = [0, 80] current_values = [0, 65] over_voltage_values = [5, 88] under_voltage_values = [0, 76] # ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ # Initializer # ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ def __init__(self, adapter, name="TDK Lambda Gen80-65", address=6, **kwargs): super().__init__( adapter, name, address, **kwargs )